97-498-107tt
I _ I I
11--0-(TyP) N*
W
A-5 N A-5 I A-5 N A-5 E
b V
r
JA-5 JA-5 §EM A-5
8
Li
flw
0 A-5 1.
ELP-1
§EM
ELP-12
E
0
BB
1! ; ! I - 0
Q - II
A-5 B1 -1 4
Q EM AUD.
ELP-13 �7
BB
0
B1'_1 B1 -27 J
QBI -2 04
Ail 94-
ELP, 3
�qq B
J
B1 "-2
04
1-21 B1- i
B
w B t---Ji Q
ELP-13
B
w 1-17
:1-21 A-
1-19
1-211
EM
TRANSFORMERS FOR ALL TYPE Y' A-5 EM
I I loft
FIXTURES ON THIS DRAWING TO 1 31-17 3
5
ELF-1 3 J.
BE CONNECTED TO CIRCUIT 8I-5.
7, TYPE 'Y FIXTURE, RE-_ER TO
E
ARCHITECTURAL' DRAV IINGS OEM
T LOCATIP�� (TYP.) -13 (9 51
_ . ____ - ! ,
FOR EXACT A-8 EM A-
ELP
I I AX- p
La I I
i A-2 P A B1-
1k 4
I'm _k-', I T
t I I �T V*1 1 i
;; ! i I i Lj
T
AA I i FLP-41N
&I
A-
B6
ot
1E
I
_ f EM i r EN! I EM L
D _k0 - 0
_h
R-ZZ-
I w"
A,
� �,� I Liv� LA L
' TY FOR A u--
#K16 K2
L
I
I C.
I I
ENTRY LEVEL PLAN =LIGHTING,
SCALE: 1/8" 1' -0"
,-,LIGHTING 'GENERAL NOTES LIGHTING PLAN NOTES
i.
1. REFER TO ARCHITECTURAL, DRAWINGS FOR -DIMENSIONED LOCATIONS OF I DOW TO SWITCH FOR CLEANING LIGHTS.
ROUGH-INS FOR WALL SCONCES, WALL MOUNTED. SIGNS, POSTER CASES,
2 TO CLEANING LIGHTS UNDER'STADIUM SEATING OR IN VOMITORIUM.
AND -LIGHT FIXTURES.
> 2. CIRCUIT ALL BACKGROUND MUSIC SPEAKERS 15TO BOOTH. #14 AUDIO 3 TO DIMMERS IN DIMMING CABINET SERVING LIGHTS IN THIS
AUDITORIUM.', 'REFER TO DIMMER SCHEDULE, THESE DWGS.
TERMINAL BOARD. CABLE TO- BE BIEL1)EN'#8770AN 1/1-2- CONDUIT.
4 TO CMUNG FAN CONTROLLER IN PROJECTION, BOOTH.
3. MOUNT ALL TYPE Y FIXTURES 6'-6", ABOVE FINISHED FLOW TO
CENTERLINE OF OUTLET BOX
5 TOGGLE- SWITCH FOR CLEANING LIGHTS. INSTALL HUBBELL
I # 96061DCH LOCKING COVER. INSTALL WITH HINGE AT TOP.
.4. MOUNT ALL TYPE 'U' FIXTURES 2'-0* ABOVE.- FINISHED FLOOR TO 6 J-BOX ABOVE CEILING FOR CONNECTION TOIDIRECTORY-MARQUEE.
CENTERLINE OF FIXTURE.
J-BOX - IN CEILING FOR 'CONNECTION TO AUDITORIUM FLAG, AND
5. ALL EXPOSED CONDUIT SHALL BE RUN PARALLEL AND PERPENDICULAR NEON COVE LIGHTING. ROUTE FLEXIBLE CONDUIT FROM. J-BOX
WITH WALLS. CONDUIT SHALL BE INSTALLED AS TIGHT TO STRUCTURE TO EQUIPMENT'SERVED.
AS POSSIBLE AND SHALL BE COORDINATED WITH WORK OF OTHER .<S� FLUSH J-BOX AT W-0-A.F.F. FOR CONNECTION TO POSTER
TRADES. FLEXIBLE CONDUIT WILL NOT BE ALLOWED FOR CONNECTION CASES. SEE ARCHITECTURAL, FOR EXACT LOCATIONS.
TO LIGHTS, SPEAKERS, ETC. IN PUBLIC AREAS WHERE THERE IS OPEN Og -BOX ABOVE CEILING FOR CONNECTION TO NEON POWER
CEILING. PAINT CONDUIT TO MATCH SURROUNDING' AREA:. ROUTE J
SUPPLY.
AS MANY CONDUITS AS POSSIBLE IN AREAS WITH CEILINGS. REFER %
J-BOX ABOVE CEILING FOR CONNECTION 'TO NEON IN REVEALS
TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 0'OF 'BEAM'. SEE ARCHITECTURAL PLANS FOR DETAILS.
6. ELECTRICAL CONTRACTOR SHALL USE EXTREME CARE WHEN INSTALLING
EXPOSED CONDUIT DROPS TO SIGNS, LIGHT FIXTURES AND OTHER ITEMS OF 40 J-BOX IN FACE OF SOFFIT WITH DUPLEX RECEPTACLE FOR MINI-
- EQUIPMENT. NUMBER OF DROPS SHALL BE KEPT TO MINIMUM POSSIBLE MARQUEE. VERIFY EXACT LOCATION WITH SIGNAGE DRAWINGS. PROVIDE EMPTY CONDUIT FROM ADJACENT TO J-BOX TO ABOVE
AND SHALL BE LOCATED SO AS TO BE AS INOBTRUSIVE AS POSSIBLE.
ACCESSIBLE CEILING FOR DATA LINE TO MINI -MARQUEE.
7. EXIT LIGHTS AND NIGHT LIGHTS SHALL BE CONNECTED TO 'HOT` FLUSH RECEPTACLE IN WALL AT 5'-0m X.F.F. FOR POSTER
UNSWITCHED LEG OF CIRCUIT INDICATED. 0 CASE. POSTER CASE PROVIDED BY OWNER. SEE
ARCHITECTURAL FOR EXACT LOCATIONS.
8. IN SPACES WITH LIGHT FIXTURES FED FROM BOTH EMERGENCY LIGHTING 'i J-BOX ABOVE CEILING FOR SIGN CIRCUITS.
PANEL (ELP) AND NORMAL POWER PANEL (A). THE SWITCH CONTROLLING
THE EMERGENCY LIGHT FIXTURES SHALL BE INSTALLED NEAREST TO DOOR. 104 UP TO CLEANING LIGHTS IN AUDITORIUM CEILING.
9. TYPE 'D' FIXTURES OVER CONCESSION COUNTERS SHALL BE CENTERED I J-BOX ABOVE CEILING WITH CONDUIT DOWN TO BACKBOX OF
'FRONT-TO-BACK' OVER RESPECTIVE COUNTER. REFER TO ARCHITECTURAL ILLUMINATED RESTROOM OR TELEPHONE SIGN.
DRAWINGS FOR EXACT COUNTER LOCATIONS. 16 SWITCHES FOR BUILDING LIGHTING CONTROL - SEE DETAIL ON
DRAWING E10.
10. ALL LIGHT FIXTURES INSTALLED IN SUSPENDED CEILINGS MUST BE FASTENED Q THIS FIXTURE CONTROL FROM 'VESTIBULE U I GHTS' SWITCH LOCATED
TO CEILING FRAMING MEMBERS PER N.E.C. 410-16C.' IN MANAGERS OFFICE.
i ? f 1® #10 WIRE THROUGHOUT CIRCUIT(S).
1 J-BOX FLUSH WITH WALL. ADD EXTENSION RINGS AS REQUIRED TO
0MOUNT FIXTURE FLUSH ON WALL PANEL SEE ARCHITECTURAL PLANS
FOR DIMENSIONED ' LOCATIONS OF ROUGH-IN.
NOT USED
120/12 VOLT 60VA TRANSFORMER WITH INTEGRAL OVERCURRENT
PROTECTION BY ALEXANDRA LIGHTING. LOCATE TRANSFORMER
ABOVE ACCESSIBLE CEILING.
PROVIDE RECESSED CLOCK RECEPTACLE AT 6'-6" A.F.F. FOR TYPE
PK## #K1v# *K2* & vK3# FIXTURES. REFER TO ARCHITECTURAL DRAWINGS
-,it - --} - - - , -- FOR EXACT LOCATION OF FIXTURES. CLOCK RECEPTACLE TO BE
GE# GE4234.
~� i- f
AA 1 1
A-2(g)
8 9,
24
3
B1r__ IB 1
B1-9
2-
2� 1
p
;7
BIL-11 B1_11 777
42CH
-121: t.5 •
►T RE
4TEF
BA K WALL
I' .I � f
L
E
Z,
EI&
i �!
1
%LIEU-
7 A-6
-7
6
-H 41
7
(,h
0FR R 1 D 0 R,
TYPE 'HH' FIXTURE (TYP OF -3). PROVIDE TWO STRAIGHT
&NNECTORS Tp JOIN 3 SECTIONS TOGETHER. MOUN
ACK ON- WALL AT 7*-0* AFF
TRj-
I OF
A
ALI 'EM L. Ll IEM
FT, i7
cb,oiac 1,00611 Go r W! as a 100) JY\1
T131 -22.24 -26.20 T61 -26,28 TB1 -30,32
TBI
%RECESSkD J-BOX FOR CONNECTION TO
LED MARQUEE . VERIFY EXACT LOCATION
WITH SIGN CONTRACTOR (I-fP 8)
TICKET BOOTH PLAN m LIGHTING
SCALE: 1/8* 1' -0"
NORTH
NOTE: ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL 2 DATA, CABLE LOOPS FOR ALL
LED MARQUEES. DATA CABLE. LOOP SHALL CONSIST OF BELDEN #88723 TWO—PAIR TWISTED
22 GAUGE SHIELDED PLENUM RATED. CABLE DAJSEY CHAINED BETWEEN COMPUTER -AT TICKET
BOOTH AND MARQUEES AS NOTED HEREAFTER. LOOP NUMBER 1 SHALL. BE BETWEEN ALL- MINI—
MARQUEES AND COMPUTER IN TICKET BOOTH. LOOP NUMBER 2 SHALL BE BETWEEN WiE EIGHT
(8) TICKET BOOTH MARQUEES AND THE TICKET BOOTH COMPUTER. LEAVE A 480 CABLE LOOP
AT EACH MARQUEE LOCATION FOR CONNECTION BY SIGNAGE CONTRACTOR. INSTALL CABLE FOR
LOOP NUMBER 1 IN CONDUIT BETWEEN TICKET BOOTH AND THEATER SPACE. -ROUTE CONDUIT
ALONG PNEUMATIC TUBE SYSTEM IF POSSIBLE.
GENERAL
AUD VEST
LIGHTING
LIGHTING
MUST BE
ON DURING
OCCUPANCY
C1
E. ACCENT
W. ACCENT
LIGHTING
LIGHTING
C4
C3
MOMENTARY
(3) MOMENTARY
SWITCHES
FOR CONTACTORS
(1) SPST SWITCH
FOR VESTIBULE LIGHTS
LABEL ALL SWITCHES.
AS INDICATED
LIGHTING CONTROL- SWITCHES
LOCATED IN MANAGER'S OFFICE
0
V
still,
4,1 1
Gould,
Evans � � ... � =� -
Amciatm, W
706 Mmadmwft
Laval me KS .66044-2M
913/842 3800
913/842 3830 fax
fi*met WWW.86&f.com
AM
Florida
z
z
ill
z
I-
A GEA Afffte
Lawwom Ks
Kama ai�r, mo
1*0 11 PA
No. Rew6m Date'
Drown cm QwW GJW
Project no. 'AMC
We NOVEMBER 1996