I i I• 1 E � t E. r t.. r. j- i E. " GENERAL NOTE„ 1. NO CONDUIT OR CABLE PENETRATIONS WILL BE ALLOWED .THROUGH AUDITORIUM DEMISING WALLS. GENERAL NOTESs I. SEAL ALL CONDUITS ENTERING OUTLET BOXES (IN AUDITORIUM COMMON WALLS) WITH RTV SIUCON SEALANT TO PREVENT SOUND TRANSMISSION. 2. MOUNT OUTLETS SHOWN IN TICKET BOOTH UNDER COUNTERS. 3. SEE ELECTRICAL DRAWINGS FOR CONTROL TIRING DIAGRAMS. 4. SEE CONCESSION DRAWINGS FOR LOCATIONS AND DIMENSIONS FOR CONCESSION EQUIPMENT AND TICKET BOOTHS. NOTE: ALL WALL BOXES SHALL BE LOCATED TO- PREVENT SOUND TRANSMISSION. OUTLET BOXES SHALL NOT BE INSTALLED BACK TO BACK. PROVIDE SOUND ISOLATION ON ALL BOXES IN, DEMISING WALLS WITH ACOUSTICAL SEALANT. ENTRY LEVEL ELECTRICAL SCALE: 1/8" _. 1'-0" IOM 5. ELECTRICAL CONTRACTOR SHAL PROVIDE AND INSTALL �1) 30A /3P, 600V., NEMA 1, FUSIBLE DISCONNECT WITCH FOR EACH FPB (FAN POWERED BOX). FUSE ACCORDING TO MANUFACTURERS NAMEPLATE RECOMMENDATION. POWE,I PLAN NOTESi F1 DOOR ALARM DEVICE FURNISHED AND INSTALLED BY ELECTRICALL CONTRACTOR. SENTROL #3003. INSTALL 1/2- CONDUIT FROM RECESSED J -BOX, SHOWN ON DRAWINGS, TO DOOR JAMB 4" BELOW TOP . OF DOOR ON HINGED SIDE. PROVIDE" 16GA. 2 CONDUCTOR PLENUM CABLE. Q DEDICATED CIRCUIT FOR CASH REGISTER SYSTEM CRT. �3 LOCATE' SPACE TEMPERATURE AND HUMIDITY SENSOR APPROXIMATELY 6'- VA.F.F. AT LOCATION INDICATED. COORDINATE LOCATION WITH WALL FINISHES. SEE ARCHITECTURAL SHEETS FOR WALL ELEVATIONS. PROVIDE 1/2" EMPTY CONDUIT TO ABOVE MEZZANINE CEIUNG- SPACE. ® LOCATE SPACE TEMPERATURE AND HUMIDITY SENSOR APPROXIMATELY 6'- 00A.F.F. AT LOCATION INDICATED. COORDINATE LOCATION WITH WALL FINISHES. SEE ARCHITECTURAL SHEETS FOR WALL ELEVATIONS. PROVIDE 1/2* EMPTY CONDUIT TO ABOVE CEIUNG SPACE WHERE BOX IS LOCATED. LABEL CONDUIT TO NUMBER OF VAV OR FPB SERVED. 5� J -BOX FOR CONNECTION TO AISLE LIGHTS. 1/2- CONDUIT WITH #12 WIRES (NUMBER INDICATED ON PLANS) TO AISLE LIGHTS TRANSFORMERS IN PROJECTION BOOTH. STUB CONDUIT FROM BOX -OUT AT FLOOR UNE - SEE DETAIL. AISLE UGHTS ARE OWNER FURNISHED AND INSTALLED. © J -BOXES FOR CONNECTION TO STEP UGHTING. 1/2w CONDUIT WITH #12 WIRES (NUMBER INDICATED ON PLANS) TO AISLE UGHTS TRANSFORMERS IN PROJECTION BOOTH. PROVIDE BOX IN WALL WITH CONDUIT TO BOX ON STEP - SEE DETAILS. STAIR LIGHTING IS OWNER FURNISHED AND INSTALLED. ❑7 DEDICATED CIRCUIT FOR SECURITY EQUIPMENT. ® DEDICATED CIRCUIT FOR ENERGY MANAGEMENT SYSTEM -CRT. a9 12 "00 "x4" RECESSED JUNCTION BOX FOR COMPUTERIZED CASH REGISTERS. AND TICKETING SYSTEM, +12"A.F.F. 10 DOOR ALARM PANEL FLUSH IN' WALL, SEE ARCHITECTURAL ELEVATIONS. MOUNT ABOVE BOOTH STATUS PANEL MAKE CONNECTIONS AT ANNUNCIATORS AND CONTROLLER, SEE SHOP DRAWINGS. 11 4'x4'x3/4" PLYWOOD FOR TELEPHONE TERMINAL BOARD. 12 3/4" EMPTY CONDUIT TO TELEPHONE TERMINAL BOARD. 13 WIRE TO MANUAL STARTER WITH PILOT LIGHT ADJACENT TO BOOTH PANEL LABEL 'PROJECTOR EXHAUST'. 14 CHIME, +76- 0 "A.F.F.. 120VOLT. 15 PUSHBUTTON, 46 "A.F.F., FOR CHIME. 16 J -BOX ABOVE CEILING FOR CONNECTION TO FLUSH VALVE TRANSFORMERS. PROVIDE LOW VOLTAGE CONNECTION TO EACH FLUSH VALVE. 17 J -BOX FOR PNEUMATIC TUBE STATION - PROVIDE RECEPTACLE TO MATCH PLUG CONFIGURATION ON MACHINE. (IF SO EQUIPPED) 18 RECIRC.' PUMP .120V -14. PROVIDE RELAY AT PUMP TO INTERFACE WITH EMS SYSTEM. 19 WEATHERPROOF, DUPLEX RECEPTACLE, GFI TYPE, ON ROOF, MOUNT_ ON UNIT. 2� PROVIDE EMPTY 1 1/Y CONDUIT FROM ADJACENT AUDIO TERMINAL BOARD DOWN TO 2' -0 A.F.F. 21 ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL (8) CONDUCTOR /22 GAUGE SHIELDED CABEL ALONG PNEUMATIC TUBE TO STATION IN TAB ROOM. USE PLENUM RATED CABEL ® 60A /3P, 25OV.,NEMA 3R FUSIBLE DISC. SWITCH. FUSE ACCORDING TO MFG. NAMEPLATEREQUIREMENTS. VERIFY EXACT LOCATION AND PROVID FINAL TERINATION TO COMPACTOR. © 4" TELEPHONE SERVICE CONDUIT UNDERFLOOR. EXTEND 5' -0" FROM BLDG. AND FLAG LOCATION. ® PORCEUN LAMPHOLDER, SWITCH AND GFI OUTLET IN ELEVATOR PIT. © 6OA /3P, 60OV. N.F., DISC. SWITCH FOR WATER HEATER. VERIFY EXACT LOCATION. 2� 3/4" CONDUIT TO ENERGY MANAGEMENT SYSTEM BOARDS IN ELECTRICAL ROOM. © GENERATOR ANNUNCIATOR PANEL MOUNT BELOW BOOTH STATUS PANELS. ® PROVIDE AND INSTALL BERKO HUH - 220- SA.WT -12, 2.5KW. 208V -10, WALL MOUNTED HEATER WITH THERMOSTAT. 29 PROVIDE RELAY TO INTERFACE WITH EMS.MOUNT RELAY IN ELECTRICAL ROOM. ® 400A /3P, 600V., NEMA 3R FUSIBLE DISC. SWITCH W/FRS -250A FUSES. 31 30A /3P, 250V., NEMA 3R FUSIBLE DISC. SWITCH. FUSE ACCORDING TO MFG. NAMEPLATE DATA. © 4" HIGH CONCRETE PAD © PROVIDE AND INSTALL BERKO VFK -204. 1.5KW. 208V -10, CABINET UNIT HEATER WITH INTEGRAL THERMOSTAT. ® CONNECT TO ELEVATOR CAB © J -BOX FOR CONNECTION TO ELEVATOR CAB UGHTS. 36 60A /3P, 600V.. FUSIBLE DISC. SWITCH W/FRS45 FUSES FOR ELEVATOR EQUIPMENT. © SWITCHES FOR BUILDING LIGHTING CONTROL - SEE DETAIL J -BOX FLUSH IN WALL 12 "A.F.F. WHERE INDICATED ON PLANS. PROVIDE BLANK COVER PLATE 1/2" CONDUIT STUB OUT AT FLOOR UNE, TYPICAL FOR CONNECTION TO AISLE UGHTS N TYPICAL DETAIL -FOR NOTE "E. LOCATIONS SCALE. NONE t - •� y.r .7J� r y F- �.,r r: rrl tr r�lrll ..i Gould &CUS 1%miatm,LC , 706 Messac�useus Lawt+e m KS 660" -2256 913/9423800 913/842 3830 faa - inteniot www.ge;af.00nt llllti�l pRaz(% South Ubmit Florida r rr c ryrrtr F Z` w z H o� H ' a z H w A GFA ARAIdo Lawwc.. Ks Kmm W NO T,,W'q PA PAoranix, AZ No. Rehm Dofe DMn MPP Checked MAP Project M. AMC 9 - -- Date 21 OCTOBER 1996 i -