Loading...
97-498-092INLINE CIRCULATOR PUMP- SYMBOLS SUPPORT INDEPENDENTLY FROM HANGER OR WALL . TRAP PRIMER: BRACKET COMPOUND GAUGE INSULATION AS WALL -AW --- ACID RESISTANT WASTE W/ SNUBBER SPECIFIED PASSING PRECISION PLUMBING DOMESTIC -WATER LINE IN PLUMBING CHASE - - DOMESTIC COLD WATER (CW) - • PRODUCTS "OREGON" OR ABOVE CEILING THRU PIPE SLEEVE - -' MODEL NO. 1 OR SLEEVE SIZED TO DOMESTIC HOT WATER (HW) ACCEPTABLE EQUIVALENT. PIPING SUIT INSULATION —T---- DOMESTIC TEMPERED WATER (TW) PROVIDE DISTRIBUTION 8 "x8" ACCESS DOOR: J.R. SMITH NO 4760 Golmid UNITS WHERE MORE OR ACCEPTABLE EQUIVALENT LOCKABLE, HINGED, FLEX BALANCE - -- DOMESTIC TEMPERED WATER RECIRCULATION (TWR) THAN ONE FLOOR I AND PRIME COATED. LOCATE IN ACCESSIBLE BUT VALE DRAIN IS SERVED BY INCONSPICOUS PLACE, OR ABOVE LAY -IN CLG. LCHECK — — V PLUMBING VENT ABOVE FLOOR (V) ONE PRIMER - -V PLUMBING VENT BELOW FLOOR (V) 1/2" "K" SOFT COPPER TUBE BELOW FLOOR VALVE SEAL WITH WATER 1/21* WITH NO JOINTS, OR HARD COPPER TUBE PACK W/ FIRE TIGHT CAULKING & FW FILTERED WATER Evans I AND SILVER SOLDER JOINTS. SLOPE TO FLOOR FLOOR DRAIN SAFING ESCUTCHEON BOTH FLEX SIDES SAN SANITARY WASTE ABOVE FLOOR (W) - - -SAN -- SANITARY WASTE BELOW FLOOR (W) &mdaies, _ FLANGE FLO OR DRAIN WITH TRAP ST STORM ABOVE FLOOR (ST) W PRIMER CONNECTION PER \-SHUTOFF BELL & GOSSETT 1" PR ALL BRONZE BOOSTER. - -ST -- STORM BELOW FLOOR (ST) SPECIFICATIONS. SEE PLANS 1® 8 GPM AT 16' HEAD, 1/6. HP 120/1/60 , FOR LOCATION(S) VALVE ® BELL & GOSSETT 1" PR ALL BRONZE BOOSTER. F FIRE PROTECTION WATER (F) 2 8 GPM AT 16' HEAD, 1/6 HP 120/l/60 706 Ma9usga�usetts _ J ELBOW DOWN 1AMCnCe KS 66044 -2M - ----+o ELBOW UP 913/8423800 t TRAP PRIMER DETAIL 2 INLINE CIRCULATION PUMP DETAIL 3 WALL PIPE PENETRATION DETAIL TEE DOWN 913/8423830fslnc NO SCALE °, NO SCALE knJNO SCALE 1ntem t+ www.gegcom iOi TEE UP --:ter— SHUT -OFF VALVE ALL BRONZE BALL CHECK VACUUM RELIEF VALVE. INSTALL ABOVE TOP OF HEATER O FLOOR SINK (FS) AMTROL XTROL ST -42 -V Iil FD % FLOOR DRAIN (FD) THERMOMETER ASME EXPANSION TANK Q FCO FLOOR CLEANOUT (FCO) -- 3/4" — 1 WCO WALL CLEANOUT (WCO) FROM RECIRCULATION PUMP (1 PER HEATER) • SPRINKLER HEAD - PENDANT HW OUTLET -�� I PRESSURE AND TEMPERATURE RELIEF VALVE O SPRINKLER HEAD - UPRIGHT DISCHARGE SIZED ON HEATER VTR VENT THRU ROOF (VTR) u ELECTRIC WATER HEATER INPUT. ROUTE DISCHARGE SEE SPECIFICATIONS i FULL SIZE. TO OPEN DRAIN Q PLAN NOTE -DESIGNATION SIZE AS SHOWN ON PLANS Q PLAN REVISION DESIGNATION • SHUT -OFF VALVE O FIXTURE NUMBER DESIGNATION " " PLUMBING EQUIPMENT DESIGNATION - TOP PORTION SUnISt� PETES PLUG e IS EQUIPMENT (HW, RTU, ETC.), BOTTOM PORTION CW INLET IS NO. OR LETTER (SEE APPROPRIATE SCHEDULE) ' NOTE: SET ON 4" � CONNECT TO EXISTING �c� TANK DRAIN�� UNION (TYP) HOUSEKEEPING —GW— GREASE WASTE PIPE BELOW FLOOR �9 PAD. South IFlod& A.O. SMITH DSE -120, 120 GALLON TANK, 24 KW ELEMENT, 109 GPH RECOVERY AT Na7 90-F RISE. SET DISCHARGE AT 140-F 480/3/60 A0. SMITH DSE -120, 120 GALLON TANK, 30 KW ELEMENT, 205 GPH RECOVERY AT 2 60-F RISE. SET DISCHARGE AT 110'F 480/3/60 <<<<< 4 ELECTRI WATER HEATER DETAIL NO SCALE zll z M�1 H z 3 , A GFA Af0do LGWWX*. KS Kano City, MO PNbOdphio. PA Tampa, fL Phowix. AZ No. Rey6w Date hn DMB Checked Rss Project no. AMC Date -- NOVEMBER 1996 P6'