11-1026-014u I SK
F /P, 120,000 BTU
2 PSI SECOND, STAGE
RE.ULATOR & VENT;UMRER
3/4„
I W
I Oo
to
1/2" GSP
N
I �
C
I ..� I] Jd
FROM HOUSE TO HOUSE FROM HOUSE
0
5
PL. PLAN (GAZEBO)
m
1/49) _ 11_0 D
ONW
SEE A-1 FOR LOCATION C 1M
C3
M W
O �
� Z
CnWN
J
Y � _
4
H
O �
Z CID
0
rn!-
� Z
O N
Q® VAS
T
O N
2 PSI REGULATOR &
NEW NATURAL GAS
METER <Zl� CAI
s
OPEN VALVE
1 1/4" SERV.
SHUT —OFF VALVE
FROM W/M
IA
PLUMBING FIXTURE SCHEDULE
SYMBOL
FIXTURE
WASTE
TRAP
VENT
C.W.
H.W.
REMARKS
WC
WATER CLOSET
3"
INTEGRAL
—
1/2"
—
190.000 BTUH
HWC
WATER CLOSET
3"
INTEGRAL
3/4"
1/2"
DIRECT VENT
HANDICAPPED
LAV
LAVATORY
1 -1/2"
1 -1/2"
—
1/2"
1/2"
COUNTER TOP
HLAV
WALL LAVATORY
1 -1/2"
1 -1/2"
1/2"
—
HANDICAPPED
BD
BIDET
2"
2"
—
1/2"
—
BT
BATH TUB
2"
2"
—
1/2"
1/2"
SK
STAINLESS SINK
1 -1/2"
1 -1/2"
1/2"
1/2"
DOUBLE COMPARTMENT
DW
DISH WASHER
1 -1/2"
1 -1/2"
1/2"
1/2"
WM
WASHING MACHINE
2"
2"
—
1/2"
1/2"
—
HANDICAPPED
TO GAZEBO
16''�
26' ,�
e INST. W/H 190 MBTU
4
2 SAO
71 24 1 611
6v
5 60I 6')
F/P, 120,000 BTU
2 PSI SECOND STAGE
DRYER, 28,000 BTU REGULATOR & VENT LIMITER
2 PSI 2ND STAGE REG ATOR & OVEN, 95,OOjl
VENT LIMITER 2 PSI AGE REGULATOR & COOKTOP, 95,000 BTU
60 VENT ITER 2 PSI 2ND STAGE REGULATOR &
'l MBTU
/ GAS ISOMETRIC 3 3 VENT LIMITER
INST.` W H 190 1'
2 PSI REGULATOR &
1
NATURAL GAS METER NEW N. T. S.
01
AIR ADMITTANCE VALVE
'II
X @1 /4 "SLP(2FU)
KITCHEN VENT DETAIL
GAS NOTES
LONGEST RUN= 109 FT
GAS TYPE: NATURAL GAS
1— USE THE FLORIDA BUILDING CODE —FUEL
GAS TABLE 402(26),(33) TO DETERMINATE PIPE
SIZES FOR LOW PRESURE SIDE. AND
TABLE(34) TO DETERMINATE PIPE
SIZES FOR HIGH PRESURE SIDE
2— USE GALVANIZED STEEL PIPE FOR
INSTALA11ON INSIDE THE HOUSE.
_17OTAL C 7 X11
. OUTLETS
1►► b
�ij�it�;���j�)��1►T � i ��.ti
1 INDOOR TANKLESS W/H
= 190,000 BTU
1 INDOOR TANKLESS W/H
= 190,000 BTU
1 COOKTOP
= 95,000 BTU
1 F/P
= 120,000 BTU
1 DRYER
= 28,000 BTU
1 OVEN
= 95,000 BTU
PLUMBING
PLAN
WATER HEATER NOTES
MODEL
CAPACITY BTUH
GAS
REMOTE C
MANUFACTURER
C.W.
H.W.
CONTROLER
2532 FFU
190.000 BTUH
NAT. GAS
BC -45 -4 US
RINNAI CONTINUUM
3/4"
3/4"
DIRECT VENT
3/4" MNPT
(960 — 120°
FORCED COMBUSTION
F RANGE )
" VENT
�I
r
r
SHUT—OFF VALVE
HEAT TRAP
I3 /4 "CW
e
3/4 "H W
3 4 "GSP
INSTANT GAS WATER HEATER DETAIL
1 /2 "CW /HWTO `GAZEBO
I
0
0.
iR M�
CD
CD
o�
�j
Y �
Z O
H
W
O cr_
U
O? FQ-
Z �
O
O N
C0 —
N
O CL
O N
pt7(000
0) LO
Z U
J 0 r-,
Q' OZ 0)
LLJ
I
w
U) o ,ly
Li rry
"E I
a
PLUMBING GENERAL NOTES
1. ALL WORK AND MATERIAL SHALL BE IN ACCORDANCE WITH THE 2007
FLORIDA BUILDING CODE, LOCAL AND ANY OTHER PERTAINING CODES
THAT APPLY.
2. THE CONTRACTOR SHALL PROVIDE ALL MINOR ITEMS WHICH ARE
OBVIO STLALtATND REASONABLY NECESSARY TO COMPLETE THE
3. THE CONTRACTOR SHALL TAKE OUT PERMITS, PROCURE CERTIFICATES
AND PAY ALL FEES CONNECTED THEREWITH,
4. BIDDERS SHALL VISIT THE SITE AND FAMIUARIZE THEMSELVES WITH
ALL CONDITIONS SURROUNDING THE WORK.
5. THE CONTRACTOR SHOULD REFER TO THE DRAWING AND SPECIFICATIONS
OF OTHER TRADES, AS SUCH ARE TO BE CONSIDERED PART OF THE
PLUMBING CONTRACT DOCUMENTS.
6. DRAWINGS ARE DIA GRAMMATIC AND INTENDED TO SHOW THE
APPROXIMATE LOCATION AND ARRANGEMENTS ONLY. PROVIDE ALL
OFFSET FITTING OR ACCESSORIES REQUIRED FOR A COMPLETE
INSTALLATION.
7. ALL MATERIALS SHALL BE NEW AND OF THE BEST QUALITY NORMALLY
USED FOR THE PURPOSE, OF TYPE AND MAKE CALLED;FOR., OR
APPROVED EQUAL.
8. THE CONTRACTOR SHALL BE A LICENSED MASTER PLUMER.
9. THE ENTIRE INSTALLATION SHALL BE PERFORMED IN A FIRST —CLASS
10. PLUMINGR WORK SEHALLLNNOT INTERFERE WITH CLEARANCE REQUIRED FOR
GENERAL AND HVAC CONSTRUCTIONS. INSTALLED PLUMBING WORK WHICH
INERFERES WITH THE WORK OF OTHER CONTRACTOR SHALL BE CHANGED
AT THE PLUMBING CONTRACTOR'S EXPENSE:
11 AS PER F.B.C. 604.9 Water hammer. The flow velocity of the water distribution system
shall be controlled to reduce the possibility o_f. water hammer:.. A water
hammer arrestor shall be installed where quick— closing valves are utilized,
unless otherwise approved. The arrestor shall be located within an
effective range of the quick — closing valve. Water— hammer arrestors shall
conform to ASSE 1010. Access shall be provided to water — hammer arrestors.
SANITARY RISER
NOTES: 1 2" PIPE OR LESS TO DRAIN @ 1/4" SLOPE
3" PIPE OR MORE TO DRAIN @ 1/8" SLOPE
2 PROVIDE ANTI —SCALD VALVES FOR TUBS
AND SHOWER HEADS
COLD & HOT WATER ISOM. UNIT -A
NOTE : NO FITTING JOINTS UNDER SLAB. ALL PRIMARY LINES TO
BATHROOMS, KITCHEN & LAUNDRY TO FINISH ABOVE SLAB.
COLD WATER
HOT WATER
a
i
i
•
i
•
v�