11-1026-011GFM CLOSUR
2 1/2" SQUARE WASHERS
12" MAX. O.0 2 PER SIDE
#10X1 1/4- SHEET
METAL SCREWS
y\
a
FIROUS GLASS DUCT
d'
FLANGE
22 GA SHEET METAL
1" X3" SCREW POP RIVET
1 " OR SPOT WELD TO
EQUIPMENT FLANGE
A/C DISC.
4" 4"
1
TYPICAL A/c PLAN
no
REF. LINES TO CONE
HUNG FROM
26 MSG, 1 1/2" STF
ON ISOMODE PIPE SI
MIN. 48" C/C
BATTINSUL
FULL LOUVERED Do
3/4 "0 PVC CONDENS
DRAIN W /3" TRAP &
WOOD AHU SUPPO
(SELF - STANDING)
AHU CONNECTION TO S/A PLENUM MECHANICALLY ATTACHED
ALSO 4" AROUND CLOSET
TO OUTSIDE
AHU ELEVATION SCHEME
NTS
30 1" 24 GA. STEEL HANGER STRAPS MAX. 10' SPACING
ROOF STRUCTURE
40 CEILING SEE ARCHITECTURAL
MINIMUM RADIUS rWUAL TO DUCT DIAMETER OR PROVIDE
AN AIR STRAIGHTENING GRID
METAL COLLAR WITH BAND CLAMP
TYPICAL BOTH ENDS OF FLEX DUCT
Og INSULATED FLEXIBLE DUCT
2" WRAP INSULATION OVER DIFFUSER SEAL ENDS OF INSULATION 4 -16d NA
�o PROVIDE 2 DUCT DIAMETERS VERTICAL RUN ABOVE DIFFUSER THRU PLY
OR PROVIDE AN AIR STRAIGHTENING GRID
DETAIL: TYPICAL FLEXIBLE DUCT CONNECTION
TO RIGID DUCTWORK INSTALLATION
N.T.S.
DUCT FR
4" DIAM.
USE 1/4" CABLES CROSSED GAGE Na
OVER THE UNIT FASTENED
TO THE PAD SUPPORT
CONDENSING UN
3 # 6 THWN (CU)
IN 1 "
60 A.DISC.BRKR
1#10 GROUNDING
6' -0" APART
CWP (METAL)
PROVIDE W /P. CAP LOW PROFILE
B.D.D. AT TOP FOR DRYER
NO SCREEN. FOR BATHROOM
PROVIDE INSECT SCREEN
i
i • •
1,01 WA
v
/-POWER AND CONTROL
CONNECTIONS TYPICAL ROOF CAP DETAIL
6" MIN.
C EAF, O° R OR WALL 6" MIN. A DRYER AND/OR TOILET EXH.
FASTEN CU TO
CON. PAD AS 6" MIN._
PER M.F.R SPEC'S LIQUID LINE
TO WITHSTAND 146 W/O INSULATION
M.P.H WINDS
(1/2" BOLTS 3" LG EMBED
IN THE CONC. EA. SIDE) 6" SCHAEDULE
CONCRETE BASE WL 40 P.V.0 PIPE
6X6 — 10/10 WW INCREASE SIZE
AS REQUIRED BY
LENGHT AND ROUTING
SEAL ENTRANCE OF REFRIGE NT
15 0 MPH LINES INTO P.V.C. PIPE W/
WITHSTAND 15
UNIT MUST INSTALED . TO IMPERMEABLE, RESILENT MATERIAL
HURRICANE FORCE WINDS SUCTION LINE W/ 1 -1/
CONDENSING UNIT MOUNTING DETAIL ARMAFLEX INSULATION
INSTALLATION OF ALL EXTERIOR C/U AT GROUND LEVEL IN SINGLE
FAMILY, DUPLEX AND FEE SIMPLE TOWNHOUSES IN UNINCORPORATED
MIAMI— DADE COUNTY SHALL BE ANCHORED TO THE CONCRETE SLAB
ON THE INSIDE OF THE UNIT, WITH AN ANCHOR BOLT OF 500 LBS
MINIMUM PULL CAPACITY
NTS
PNL
B
3" TO F.I
ELECTRICAL RISER DIAGRAM
3 # 1/0 THWN (CU)
1ki 4 4 /n" f1^K1M1 IIT
t
Iva
GROUND ELECTRODE
TO FOUNDATION REBAR
CONCRETE — ENCASED ELECTRODE. An electrode encased by
at least 2" of concrete, located within and near the bottom of a
concrete foundation or footing that is in direct contact w /the
earth, consisting of at least 20' of one or more steel reinforcing
bars or rods of not less than 1/2" diameter or consisting of at least
20' of bare copper conductor not smaller than #4 AWG.
(,—ROOF TRUSSES
ELECTRICAL
WIRES
01111111HO
\TREMPSTOP IA
BOTHS SIDES
1 -HR. FIRE
UL SYSTEM NN WL 3044 RATED CEILING
F- RATING: 1 OR 2 HR. T RATING: 1, 1 \"
SEALENT DEPTH \" WITH \" CROWN,
SEALANT TO BE MANUFACTURED BY
TREMSTOP IA
LIGHT CARBON MONO IDE+
SMOKE DETECT PR COMBO
D LINE SIDE 120 V
OF SWITCH
SWITCH LEG
120/240V SUB-
1 PH,3W
PANEL "A"
•
60 AMPS. MCB
SURFACE MTD.
CIRCUIT
FUNCTION
LOAD
VOLTS
C/B TRIP
WIRE
# OF CIR.
WATTS ALLOWED
A -1,3
SMALL APL.
A/C # 2 CONDENSING UNIT
120
1P -20
#12
1
1500
A -2
LIGHT & RECEPT.
1P -20
120
1P-15
#14
1
1500
A -4
BAR REF.
1500
120
1P -20
#12
1
1500
A -5 -7
SPACES
SMALL APPLIANCES
120
1P -20
#12
4500
:
OUTLETS BATH
120
1P-20
TOTAL LOAD = 4500
120/240V i AMPS. MCB
1 PH, 3W SURFACE MTD.
• - •
•
�ii�iYii��iii'�i71i1
�.�
ROMEX
LOAD
• r
STRIP HEATER /BLOWER #2 (10.0 KW)
LANDSCAPE LIGTHING
2P -60
#6
10000
C— 2,4
A/C # 2 CONDENSING UNIT
-
-
��IE;�
(4000)
C— 5
MICROWAVE
• of
1P -20
GARAGE DOOR
1500
C— 6
REFRIGERATOR
120
1P-20
#12
1500
C— 7
DISHWASHER
120
1P -20
#12
1200
C -8 -10
SMALL APPLIANCES
120
1P -20
#12
4500
:
OUTLETS BATH
120
1P-20
#12
1200
C -12
COOKTOP
'STRIP HEATER/BLOWER #1 (10.0
1P -20
#12
1500
C -13
HOOD
120
1P -20
#12
1500
C -14—
LIGHT & RECEPT.
120
1P -15
#14
!
!
SPACES
!!
BAR SMAL APPLIANCES
FLOOR AREA = 3898 S.F.® 3 WATTS = 11694 TOTAL LOAD = 34594
!i
-GARAGE DOOR
TOTAL LOAD 28200
DEMAND LOAD NOTE: ALL ELECTRICAL EQUIPMENT
WIRING RATED CAA 75" C
ELECTRICAL LOAD CALCULATIONS
CONNECT LOAD LESS A/C = 28.2 -1OKW = 18.2 KW
10 KW @ 100% = 10.0 KW
8. REST @ 40% = 3.28 KW
A/C OHTNG 100% = 10.0 KW
DEMAND LOAD = 23.28/240 = 97 AMPS.
120/240V ELECTRIC PANEL C 150 AMPS. MCB
1 PH,3W SURFACE MTD.
CIRCUIT
FUNCTION
VOLTS
C/B TRIP
ROMEX
LOAD
C— 1,3
STRIP HEATER /BLOWER #2 (10.0 KW)
240
2P -60
#6
10000
C— 2,4
A/C # 2 CONDENSING UNIT
240
2P -40
#8
(4000)
C— 5
MICROWAVE
120
1P -20
#12
1500
C— 6
REFRIGERATOR
120
1P-20
#12
1500
C— 7
DISHWASHER
120
1P -20
#12
1200
C -8 -10
SMALL APPLIANCES
120
1P -20
#12
4500
C -11
DISPOSAL
120
1P-20
#12
1200
C -12
COOKTOP
120
1P -20
#12
1500
C -13
HOOD
120
1P -20
#12
1500
C -14—
LIGHT & RECEPT.
120
1P -15
#14
11694
C -15
SPACES
FLOOR AREA = 3898 S.F.® 3 WATTS = 11694 TOTAL LOAD = 34594
ELECTRICAL LOAD CALCULATIONS
LOAD TABULATION CONNECT LOAD LESS A/C = (34.6 -10) 24.6 KW
10 KW @ 100% = 10.0 KW
PANEL "C" = 108 A 14.6 REST @ 40% = 5.84 KW
PANEL "B" = 97 A A/C OHTNG 100% = 10.0 KW
TOTAL = 205 A DEMAND LOAD = 25.84/240 = 108 AMPS.
SMOKE DETECTOR
CONNECTION DETAIL NTS
CARBON MONOXIDE+ SMOKE DETECTOR SHALL BE HARDWIRED (110 V TYPR)
SMOKE DETECTOR COMBO TO A NON- SWITCHABLE LIGHTING
SHALL NOT BE PLACED CIRCUIT WITH BATTERY BACK -UP AND SHALL NOT BE
WITHIN 3 FT. OF ANY CONNECTED ONTO THE LOAD SIDE OF GROUND FAULT
A/C GRILL. CIRCUIT INTERRUPTER ALL C.M /SMOKE COMBO DETECTORS WITHIN EACH
UNIT SHALL BE INTERCONNECTED
SO ALL DETECTORS SOUND WHEN ANY DETECTOR IS ACTIVATED
AND COMPLY W/ N.E.0 210 -12
0 111MAMMU-1 E C T R I C A L
— ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW BASE
FLOOD ELEVATION SHALL BE INSTALLED AT THE HIGHEST PERMITTED
ELEVATION AND SHALL BE INSTALLED ON (SEPARATE) INDEPENDENT
CIRCUITS FROM THOSE IN THE HABITABLE AREAS.
— NO APPLIANCES OR APPLIANCE OUTLETS SHALL BE INSTALLED BELOW
BASE FLOOD ELEVATION.
— A/C COMPRESSOR SHALL BE INSTALLED ABOVE BASE FLOOD
ELEVATION.
— MAIN CIRCUIT BREAKER PANELS SHALLBE LOCATED ABOVE BASE
FLOOD ELEVATION.
— WE WILL CONFER WITH FLORIDA POWER & LIGHT TO LOCATE THE
ELECTRIC METER TO COMPLY WITH FEDERAL EMERGENCY MANAGEMENT
AGENCY REQUIREMENTS.
— ALL ELECTRICAL WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY
WITH LOCAL CODES AND ORDINANCE & ALL STANDARDS OF CONSTRUCTION
ESTABLISHED BY THE LANDLORD.
— ALL CONDUCTORS SHALL BE TWH OR THWN COPPER. ALL EXPOSED
CONDUITS SHALL BE RUN AS NEAT AS POSSIBLE AND PAINTED TO MATCH
COLOR OF SURROUNDINGS. P.V.C. CONDUIT SHALL ONLY BE USED IN
SLAB OR UNDERGROUND AT A MINIMUM DEPTH OF 24 ".
— FLEXIABLE CONDUIT SHALL BE USED FOR CONNECTION TO ALL
VIBRATING EQUIPMENT SUCH AS MOTORS, ETC.
— ALL WIRING DEVICES SHALL BE LEVITON "DECORA" SERIES OR EQUAL
AS APPROVED BY ARCHITECT OR ENGINEER. COLOR SELECTED BY
ARCHITECT.
— ALL RECEPTACLES SHALL BE INSTALLED AT 12 "A.F.F. UNLESS
OTHERWISE NOTED.
- ELECTRICAL POWER AND CONTROL WIRING FOR HVAC AND MECHANICAL
EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL
CONTRACTOR.
— ELECTRICAL CONTRACTOR SHALL VERIFY THE CEILING FINISHES AND
SUSPENSION SYSTEM FOR SELECTION OF THE PROPER TRIM AND SUPPORT
ARRANGEMENT OF THE FIXTURE.
— ELECTRICAL CONTRACTORS SHALL COORDINATE HIS WORK WITH THE
ARCHITECT BEFORE ROUGH INSTALLATION OF LIGHTS, RECEPTACLES,
SWITCHES AND EQUIPMENT FOR EXACT LOCATIONS.
— ALL ELECTRICAL EQUIPMENT MUST BE U.L. APPROVED.
— ALL CIRCUITS WHO FEENDING ALL MONOFASICS OUTLET
OF 125V & 15A & 20A , INSTALL IN ALL BEDROOMS
INCLUDING RECEPTICALS, LIGHTS & C.M SD COMBO IN THAT ROOM)
HOULD BE PROTECTED W/ INTERRUPTOR CIRCUIT OF ARC. FAULT
REQ. AS PER N.E.0 210 -12
— ALL 125 VOLT, 15 & 20 AMP. RECEPTACLES INSTALLED IN AREAS
SPECIFIED BY 210.12 SHALL BE LISTED TAMPER RESISTANT
NOTE: ALL ELECTRICAL EQUIPMENT
WIRING RATED @ 75" C
t
•
•
•
•
•
•
• Z •
i CL •
i
7
O
LL
;9W
t
1 10
LI
V) uo
co
v)
nC"
0
O
05-11,
n
SHEET
E/M