11-1026-011GFM CLOSUR 2 1/2" SQUARE WASHERS 12" MAX. O.0 2 PER SIDE #10X1 1/4- SHEET METAL SCREWS y\ a FIROUS GLASS DUCT d' FLANGE 22 GA SHEET METAL 1" X3" SCREW POP RIVET 1 " OR SPOT WELD TO EQUIPMENT FLANGE A/C DISC. 4" 4" 1 TYPICAL A/c PLAN no REF. LINES TO CONE HUNG FROM 26 MSG, 1 1/2" STF ON ISOMODE PIPE SI MIN. 48" C/C BATTINSUL FULL LOUVERED Do 3/4 "0 PVC CONDENS DRAIN W /3" TRAP & WOOD AHU SUPPO (SELF - STANDING) AHU CONNECTION TO S/A PLENUM MECHANICALLY ATTACHED ALSO 4" AROUND CLOSET TO OUTSIDE AHU ELEVATION SCHEME NTS 30 1" 24 GA. STEEL HANGER STRAPS MAX. 10' SPACING ROOF STRUCTURE 40 CEILING SEE ARCHITECTURAL MINIMUM RADIUS rWUAL TO DUCT DIAMETER OR PROVIDE AN AIR STRAIGHTENING GRID METAL COLLAR WITH BAND CLAMP TYPICAL BOTH ENDS OF FLEX DUCT Og INSULATED FLEXIBLE DUCT 2" WRAP INSULATION OVER DIFFUSER SEAL ENDS OF INSULATION 4 -16d NA �o PROVIDE 2 DUCT DIAMETERS VERTICAL RUN ABOVE DIFFUSER THRU PLY OR PROVIDE AN AIR STRAIGHTENING GRID DETAIL: TYPICAL FLEXIBLE DUCT CONNECTION TO RIGID DUCTWORK INSTALLATION N.T.S. DUCT FR 4" DIAM. USE 1/4" CABLES CROSSED GAGE Na OVER THE UNIT FASTENED TO THE PAD SUPPORT CONDENSING UN 3 # 6 THWN (CU) IN 1 " 60 A.DISC.BRKR 1#10 GROUNDING 6' -0" APART CWP (METAL) PROVIDE W /P. CAP LOW PROFILE B.D.D. AT TOP FOR DRYER NO SCREEN. FOR BATHROOM PROVIDE INSECT SCREEN i i • • 1,01 WA v /-POWER AND CONTROL CONNECTIONS TYPICAL ROOF CAP DETAIL 6" MIN. C EAF, O° R OR WALL 6" MIN. A DRYER AND/OR TOILET EXH. FASTEN CU TO CON. PAD AS 6" MIN._ PER M.F.R SPEC'S LIQUID LINE TO WITHSTAND 146 W/O INSULATION M.P.H WINDS (1/2" BOLTS 3" LG EMBED IN THE CONC. EA. SIDE) 6" SCHAEDULE CONCRETE BASE WL 40 P.V.0 PIPE 6X6 — 10/10 WW INCREASE SIZE AS REQUIRED BY LENGHT AND ROUTING SEAL ENTRANCE OF REFRIGE NT 15 0 MPH LINES INTO P.V.C. PIPE W/ WITHSTAND 15 UNIT MUST INSTALED . TO IMPERMEABLE, RESILENT MATERIAL HURRICANE FORCE WINDS SUCTION LINE W/ 1 -1/ CONDENSING UNIT MOUNTING DETAIL ARMAFLEX INSULATION INSTALLATION OF ALL EXTERIOR C/U AT GROUND LEVEL IN SINGLE FAMILY, DUPLEX AND FEE SIMPLE TOWNHOUSES IN UNINCORPORATED MIAMI— DADE COUNTY SHALL BE ANCHORED TO THE CONCRETE SLAB ON THE INSIDE OF THE UNIT, WITH AN ANCHOR BOLT OF 500 LBS MINIMUM PULL CAPACITY NTS PNL B 3" TO F.I ELECTRICAL RISER DIAGRAM 3 # 1/0 THWN (CU) 1ki 4 4 /n" f1^K1M1 IIT t Iva GROUND ELECTRODE TO FOUNDATION REBAR CONCRETE — ENCASED ELECTRODE. An electrode encased by at least 2" of concrete, located within and near the bottom of a concrete foundation or footing that is in direct contact w /the earth, consisting of at least 20' of one or more steel reinforcing bars or rods of not less than 1/2" diameter or consisting of at least 20' of bare copper conductor not smaller than #4 AWG. (,—ROOF TRUSSES ELECTRICAL WIRES 01111111HO \TREMPSTOP IA BOTHS SIDES 1 -HR. FIRE UL SYSTEM NN WL 3044 RATED CEILING F- RATING: 1 OR 2 HR. T RATING: 1, 1 \" SEALENT DEPTH \" WITH \" CROWN, SEALANT TO BE MANUFACTURED BY TREMSTOP IA LIGHT CARBON MONO IDE+ SMOKE DETECT PR COMBO D LINE SIDE 120 V OF SWITCH SWITCH LEG 120/240V SUB- 1 PH,3W PANEL "A" • 60 AMPS. MCB SURFACE MTD. CIRCUIT FUNCTION LOAD VOLTS C/B TRIP WIRE # OF CIR. WATTS ALLOWED A -1,3 SMALL APL. A/C # 2 CONDENSING UNIT 120 1P -20 #12 1 1500 A -2 LIGHT & RECEPT. 1P -20 120 1P-15 #14 1 1500 A -4 BAR REF. 1500 120 1P -20 #12 1 1500 A -5 -7 SPACES SMALL APPLIANCES 120 1P -20 #12 4500 : OUTLETS BATH 120 1P-20 TOTAL LOAD = 4500 120/240V i AMPS. MCB 1 PH, 3W SURFACE MTD. • - • • �ii�iYii��iii'�i71i1 �.� ROMEX LOAD • r STRIP HEATER /BLOWER #2 (10.0 KW) LANDSCAPE LIGTHING 2P -60 #6 10000 C— 2,4 A/C # 2 CONDENSING UNIT - - ��IE;� (4000) C— 5 MICROWAVE • of 1P -20 GARAGE DOOR 1500 C— 6 REFRIGERATOR 120 1P-20 #12 1500 C— 7 DISHWASHER 120 1P -20 #12 1200 C -8 -10 SMALL APPLIANCES 120 1P -20 #12 4500 : OUTLETS BATH 120 1P-20 #12 1200 C -12 COOKTOP 'STRIP HEATER/BLOWER #1 (10.0 1P -20 #12 1500 C -13 HOOD 120 1P -20 #12 1500 C -14— LIGHT & RECEPT. 120 1P -15 #14 ! ! SPACES !! BAR SMAL APPLIANCES FLOOR AREA = 3898 S.F.® 3 WATTS = 11694 TOTAL LOAD = 34594 !i -GARAGE DOOR TOTAL LOAD 28200 DEMAND LOAD NOTE: ALL ELECTRICAL EQUIPMENT WIRING RATED CAA 75" C ELECTRICAL LOAD CALCULATIONS CONNECT LOAD LESS A/C = 28.2 -1OKW = 18.2 KW 10 KW @ 100% = 10.0 KW 8. REST @ 40% = 3.28 KW A/C OHTNG 100% = 10.0 KW DEMAND LOAD = 23.28/240 = 97 AMPS. 120/240V ELECTRIC PANEL C 150 AMPS. MCB 1 PH,3W SURFACE MTD. CIRCUIT FUNCTION VOLTS C/B TRIP ROMEX LOAD C— 1,3 STRIP HEATER /BLOWER #2 (10.0 KW) 240 2P -60 #6 10000 C— 2,4 A/C # 2 CONDENSING UNIT 240 2P -40 #8 (4000) C— 5 MICROWAVE 120 1P -20 #12 1500 C— 6 REFRIGERATOR 120 1P-20 #12 1500 C— 7 DISHWASHER 120 1P -20 #12 1200 C -8 -10 SMALL APPLIANCES 120 1P -20 #12 4500 C -11 DISPOSAL 120 1P-20 #12 1200 C -12 COOKTOP 120 1P -20 #12 1500 C -13 HOOD 120 1P -20 #12 1500 C -14— LIGHT & RECEPT. 120 1P -15 #14 11694 C -15 SPACES FLOOR AREA = 3898 S.F.® 3 WATTS = 11694 TOTAL LOAD = 34594 ELECTRICAL LOAD CALCULATIONS LOAD TABULATION CONNECT LOAD LESS A/C = (34.6 -10) 24.6 KW 10 KW @ 100% = 10.0 KW PANEL "C" = 108 A 14.6 REST @ 40% = 5.84 KW PANEL "B" = 97 A A/C OHTNG 100% = 10.0 KW TOTAL = 205 A DEMAND LOAD = 25.84/240 = 108 AMPS. SMOKE DETECTOR CONNECTION DETAIL NTS CARBON MONOXIDE+ SMOKE DETECTOR SHALL BE HARDWIRED (110 V TYPR) SMOKE DETECTOR COMBO TO A NON- SWITCHABLE LIGHTING SHALL NOT BE PLACED CIRCUIT WITH BATTERY BACK -UP AND SHALL NOT BE WITHIN 3 FT. OF ANY CONNECTED ONTO THE LOAD SIDE OF GROUND FAULT A/C GRILL. CIRCUIT INTERRUPTER ALL C.M /SMOKE COMBO DETECTORS WITHIN EACH UNIT SHALL BE INTERCONNECTED SO ALL DETECTORS SOUND WHEN ANY DETECTOR IS ACTIVATED AND COMPLY W/ N.E.0 210 -12 0 111MAMMU-1 E C T R I C A L — ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW BASE FLOOD ELEVATION SHALL BE INSTALLED AT THE HIGHEST PERMITTED ELEVATION AND SHALL BE INSTALLED ON (SEPARATE) INDEPENDENT CIRCUITS FROM THOSE IN THE HABITABLE AREAS. — NO APPLIANCES OR APPLIANCE OUTLETS SHALL BE INSTALLED BELOW BASE FLOOD ELEVATION. — A/C COMPRESSOR SHALL BE INSTALLED ABOVE BASE FLOOD ELEVATION. — MAIN CIRCUIT BREAKER PANELS SHALLBE LOCATED ABOVE BASE FLOOD ELEVATION. — WE WILL CONFER WITH FLORIDA POWER & LIGHT TO LOCATE THE ELECTRIC METER TO COMPLY WITH FEDERAL EMERGENCY MANAGEMENT AGENCY REQUIREMENTS. — ALL ELECTRICAL WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH LOCAL CODES AND ORDINANCE & ALL STANDARDS OF CONSTRUCTION ESTABLISHED BY THE LANDLORD. — ALL CONDUCTORS SHALL BE TWH OR THWN COPPER. ALL EXPOSED CONDUITS SHALL BE RUN AS NEAT AS POSSIBLE AND PAINTED TO MATCH COLOR OF SURROUNDINGS. P.V.C. CONDUIT SHALL ONLY BE USED IN SLAB OR UNDERGROUND AT A MINIMUM DEPTH OF 24 ". — FLEXIABLE CONDUIT SHALL BE USED FOR CONNECTION TO ALL VIBRATING EQUIPMENT SUCH AS MOTORS, ETC. — ALL WIRING DEVICES SHALL BE LEVITON "DECORA" SERIES OR EQUAL AS APPROVED BY ARCHITECT OR ENGINEER. COLOR SELECTED BY ARCHITECT. — ALL RECEPTACLES SHALL BE INSTALLED AT 12 "A.F.F. UNLESS OTHERWISE NOTED. - ELECTRICAL POWER AND CONTROL WIRING FOR HVAC AND MECHANICAL EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. — ELECTRICAL CONTRACTOR SHALL VERIFY THE CEILING FINISHES AND SUSPENSION SYSTEM FOR SELECTION OF THE PROPER TRIM AND SUPPORT ARRANGEMENT OF THE FIXTURE. — ELECTRICAL CONTRACTORS SHALL COORDINATE HIS WORK WITH THE ARCHITECT BEFORE ROUGH INSTALLATION OF LIGHTS, RECEPTACLES, SWITCHES AND EQUIPMENT FOR EXACT LOCATIONS. — ALL ELECTRICAL EQUIPMENT MUST BE U.L. APPROVED. — ALL CIRCUITS WHO FEENDING ALL MONOFASICS OUTLET OF 125V & 15A & 20A , INSTALL IN ALL BEDROOMS INCLUDING RECEPTICALS, LIGHTS & C.M SD COMBO IN THAT ROOM) HOULD BE PROTECTED W/ INTERRUPTOR CIRCUIT OF ARC. FAULT REQ. AS PER N.E.0 210 -12 — ALL 125 VOLT, 15 & 20 AMP. RECEPTACLES INSTALLED IN AREAS SPECIFIED BY 210.12 SHALL BE LISTED TAMPER RESISTANT NOTE: ALL ELECTRICAL EQUIPMENT WIRING RATED @ 75" C t • • • • • • • Z • i CL • i 7 O LL ;9W t 1 10 LI V) uo co v) nC" 0 O 05-11, n SHEET E/M