11-365-003NOTE: ALL EGRESS WINDOWS TO COMPLY W/ FBC: AN OUTSIDE WINDOW OR DOOR OPERABLE FROM THE INSIDE WITHOUT THE USE OF TOOLS AND PROVIDING A CLEAR OPENING OF NOT LESS THAN 20' WIDE x24' HIGH AND 5.1 SQ. FT.IN AREA. THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44' OFF THE FLOOR THE MODE OF OPERATION MUST NOT REQUIRE THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE OR EFFORT TO MAKE AVAILABLE THE REQUIRED CLEAR OPENING, AND NO PART OF THE OPERATION MECHANISM SHALL BE PLACED HIGHER THAN 54' ABOVE THE FINISHED FLOOR =/" = Td ICC 1/2' DRYWALL EXISTING 3 5/5' METAL TOP RUNNER CONTINUOS INTERIOR MET. PARTITION 3 5/8' STUDS AT 24' o% 25 GAGE I/2' DRYWALL FINISHEDTO MATCH EXISTING 3 5/5' METAL BOT. RUNNER CONTINUOS SEALANT 010 NAIL A 12' OC. TYPICAL INTERIOR NON BEARING PARTTION scale 3/4' = 1' -0' TOP OF EGREES WINDOW �L NOTES I- ALL BATHROOMS AND CLOSET DOORS LATCHES SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR / FROM THE INSIDE AND SHALL BE DESIGNED TO PERMIT THE OPENING OF THE LOCKED DOOR FROM THE OUTSIDE IN AN EMERGENCY. BOT. OF EGREES WINDOW / Q Z 1= � � N t t FIN. FLOOR -� TYPICAL EGRESS WINDOW DETAIL SCAM 1W ■ r-o' CONTRACTOR NOTES ALL AFFECTED WALL FINISHES DURING CONSTRUCTION TO BE RESTORED TO ITS ORIGINAL CONDITION AREAS OUTSIDE OF CONSTRUCTION SPACE TO BE PROTECTED FROM DUST AND DEBRIS AT ALL TIMES NEW WALLS AND CEILING ARE TO BE FINISHED TO MATCH EXISTING EXISTING 2nd FLOOR PLAN 1/4" SCALE REMODELING AREA = 115 SR NEW WINDOWS NOTE EXISTING FIX. GLASS OPENINS ARE SIZED TO ACCOMODATE NEW SPECIED WINDOWS EXISTING FIX. GLASS 4 HR WINDOW (EGRESS) REPLACE EXISTING FIX. GLASS W/ DBL. 34 HR WINDOW LEGEND LOT EXIST. 4' PARTITION EXIST. 6' BLOCK WALL op SOIJ S7-R LDS G DyjA�11A,v,, rUR /'ROVED .9Y• 1� � � ;'1wRdn tip. NT t20012 5CHF-PUL� • SIZE TYPE MATERIAL JAMB FINISH FRAME THRESHOLD REMARKS I V -0' x 8' X 1 3/8 SWINGING WOOD WOOD PAINTED WOOD NO 2 W -0' X V -0' BI -FOLD WOOD FULL LOUVER WOOD PAINTED NONE NO Q Q 0 U T !L O 1u U NOTES I- ALL BATHROOMS AND CLOSET DOORS LATCHES SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR / FROM THE INSIDE AND SHALL BE DESIGNED TO PERMIT THE OPENING OF THE LOCKED DOOR FROM THE OUTSIDE IN AN EMERGENCY. BOT. OF EGREES WINDOW / Q Z 1= � � N t t FIN. FLOOR -� TYPICAL EGRESS WINDOW DETAIL SCAM 1W ■ r-o' CONTRACTOR NOTES ALL AFFECTED WALL FINISHES DURING CONSTRUCTION TO BE RESTORED TO ITS ORIGINAL CONDITION AREAS OUTSIDE OF CONSTRUCTION SPACE TO BE PROTECTED FROM DUST AND DEBRIS AT ALL TIMES NEW WALLS AND CEILING ARE TO BE FINISHED TO MATCH EXISTING EXISTING 2nd FLOOR PLAN 1/4" SCALE REMODELING AREA = 115 SR NEW WINDOWS NOTE EXISTING FIX. GLASS OPENINS ARE SIZED TO ACCOMODATE NEW SPECIED WINDOWS EXISTING FIX. GLASS 4 HR WINDOW (EGRESS) REPLACE EXISTING FIX. GLASS W/ DBL. 34 HR WINDOW LEGEND LOT EXIST. 4' PARTITION EXIST. 6' BLOCK WALL op SOIJ S7-R LDS G DyjA�11A,v,, rUR /'ROVED .9Y• 1� � � ;'1wRdn tip. NT (0 i ti N i N O m I Lo Lo or In W � IL ° Q° a I o O UIr- N i�1 LL W iW- � N Q Q 0 U T !L O 1u U z w w _ w O w !1 1' 1 Q Z � lu O Q O LL w W 0 Z a DATE 3 -11 -2011 REVISIONS COMMISSION NUMBER C11 -003 DRAWING NUMBER 100 OF �O