11-365-003NOTE:
ALL EGRESS WINDOWS TO COMPLY W/ FBC:
AN OUTSIDE WINDOW OR DOOR OPERABLE FROM THE INSIDE
WITHOUT THE USE OF TOOLS AND PROVIDING A CLEAR
OPENING OF NOT LESS THAN 20' WIDE x24' HIGH AND 5.1 SQ.
FT.IN AREA. THE BOTTOM OF THE OPENING SHALL NOT BE
MORE THAN 44' OFF THE FLOOR THE MODE OF OPERATION
MUST NOT REQUIRE THE USE OF A KEY, TOOL, SPECIAL
KNOWLEDGE OR EFFORT TO MAKE AVAILABLE THE
REQUIRED CLEAR OPENING, AND NO PART OF THE
OPERATION MECHANISM SHALL BE PLACED HIGHER THAN 54'
ABOVE THE FINISHED FLOOR
=/" = Td ICC
1/2' DRYWALL EXISTING
3 5/5' METAL TOP RUNNER
CONTINUOS
INTERIOR MET. PARTITION
3 5/8' STUDS AT 24' o%
25 GAGE
I/2' DRYWALL
FINISHEDTO MATCH EXISTING
3 5/5' METAL BOT. RUNNER
CONTINUOS
SEALANT
010 NAIL A 12' OC.
TYPICAL INTERIOR NON BEARING PARTTION
scale 3/4' = 1' -0'
TOP OF EGREES WINDOW
�L
NOTES
I- ALL BATHROOMS AND CLOSET DOORS LATCHES SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR
/ FROM THE INSIDE AND SHALL BE DESIGNED TO PERMIT THE OPENING OF THE LOCKED DOOR FROM THE
OUTSIDE IN AN EMERGENCY.
BOT. OF EGREES WINDOW / Q Z
1= �
� N
t t
FIN. FLOOR -�
TYPICAL EGRESS WINDOW DETAIL
SCAM 1W ■ r-o'
CONTRACTOR NOTES
ALL AFFECTED WALL FINISHES
DURING CONSTRUCTION TO BE
RESTORED TO ITS ORIGINAL CONDITION
AREAS OUTSIDE OF CONSTRUCTION SPACE
TO BE PROTECTED FROM DUST AND DEBRIS
AT ALL TIMES
NEW WALLS AND CEILING ARE TO BE FINISHED
TO MATCH EXISTING
EXISTING 2nd FLOOR PLAN 1/4" SCALE
REMODELING AREA = 115 SR
NEW WINDOWS NOTE
EXISTING FIX. GLASS OPENINS ARE
SIZED TO ACCOMODATE NEW
SPECIED WINDOWS
EXISTING FIX. GLASS
4 HR WINDOW (EGRESS)
REPLACE EXISTING FIX. GLASS
W/ DBL. 34 HR WINDOW
LEGEND
LOT
EXIST. 4' PARTITION
EXIST. 6' BLOCK WALL
op SOIJ
S7-R LDS G DyjA�11A,v,,
rUR
/'ROVED .9Y•
1�
� � ;'1wRdn tip.
NT
t20012 5CHF-PUL�
•
SIZE
TYPE
MATERIAL
JAMB
FINISH
FRAME
THRESHOLD
REMARKS
I
V -0' x 8' X 1 3/8
SWINGING
WOOD
WOOD
PAINTED
WOOD
NO
2
W -0' X V -0'
BI -FOLD
WOOD FULL LOUVER
WOOD
PAINTED
NONE
NO
Q
Q
0
U
T
!L
O
1u
U
NOTES
I- ALL BATHROOMS AND CLOSET DOORS LATCHES SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR
/ FROM THE INSIDE AND SHALL BE DESIGNED TO PERMIT THE OPENING OF THE LOCKED DOOR FROM THE
OUTSIDE IN AN EMERGENCY.
BOT. OF EGREES WINDOW / Q Z
1= �
� N
t t
FIN. FLOOR -�
TYPICAL EGRESS WINDOW DETAIL
SCAM 1W ■ r-o'
CONTRACTOR NOTES
ALL AFFECTED WALL FINISHES
DURING CONSTRUCTION TO BE
RESTORED TO ITS ORIGINAL CONDITION
AREAS OUTSIDE OF CONSTRUCTION SPACE
TO BE PROTECTED FROM DUST AND DEBRIS
AT ALL TIMES
NEW WALLS AND CEILING ARE TO BE FINISHED
TO MATCH EXISTING
EXISTING 2nd FLOOR PLAN 1/4" SCALE
REMODELING AREA = 115 SR
NEW WINDOWS NOTE
EXISTING FIX. GLASS OPENINS ARE
SIZED TO ACCOMODATE NEW
SPECIED WINDOWS
EXISTING FIX. GLASS
4 HR WINDOW (EGRESS)
REPLACE EXISTING FIX. GLASS
W/ DBL. 34 HR WINDOW
LEGEND
LOT
EXIST. 4' PARTITION
EXIST. 6' BLOCK WALL
op SOIJ
S7-R LDS G DyjA�11A,v,,
rUR
/'ROVED .9Y•
1�
� � ;'1wRdn tip.
NT
(0
i
ti
N
i
N
O
m
I
Lo
Lo
or
In
W
�
IL
°
Q°
a
I
o
O
UIr-
N
i�1 LL
W
iW-
�
N
Q
Q
0
U
T
!L
O
1u
U
z
w
w
_ w
O w
!1 1' 1 Q
Z �
lu O
Q
O
LL
w W
0 Z
a
DATE
3 -11 -2011
REVISIONS
COMMISSION NUMBER
C11 -003
DRAWING NUMBER
100
OF �O