14-644-002I K FCI - Fire Alarm Panel Qty Standby Alarm FCI--E3 FCI ILI -S -E3 FCI LCD -E3 FCI LCD -7100 FCI DACT -E3 FCI ASM -16 AMM -21RIF AOM -2RF Main Network Control Panel Interface Expansion Board - Two Additional SLC'S LCD Display/Switch Control Remote Annunicator Digital Communicator Auxilliary Switch Addressable Input /Output Module Control Relay 68:1 -1 is � 1 1 1 1 1 1 21 6 0.0810 0.0810 0.0240 0.0120 0.0180 0.0110 0.0013 0,0004 0.1500 0.1500 0.0290 0.0230 0.0180 0.0110 1 0.0240 0.0065 0.0810 0.0810 0.0240 0.0120 0.0180 0.0110 0.0273 0.0023 0.1500 0.1500 0.0280 0.0230 0.0180 0.0110 0.5040 0.0390 ASD -PI-2F D4120 Smoke Detector Duct Smoke Detector Amps 13 4 0.0003 0.0210 0.0065 0.0001 0.0039 0.0840 0.0845 0.0003 ATD -L2F MS -7 Heat Detector Manual Pull Station 2 Y 3 15 0.0003 0.0003 0.0065 0.0070 0.0009 0.0045 0.0195 0.1050 ------- - - - - -- ----------- - - - - -- --------- --------------------- 5 0 0 0 0 0 0 ------------------------- - - - - -- ------------------------- - - - - -- • � V• 0 0 0 0 0 Standby 24 Hours Totals 0.34985 1.13226 0 0 0 Alarm 5 Minutes Wire Guage 14 NACs 14 - Aux Pwr 4uW•• This booster his 4 circuits Oh n/K 1 3.07 3.07 Totals 0.350 1.132 •fr•r AH Calculations 8.3964 0.094 • Total AH 8.491 Derate Factor 1.20 JAdjusted Minimum 1U.lay * Battery Provided 12AH Voltage Drop and Battery Power Supply Model FCPS -24FS6 Calculations rF•Y r Uri Booster BI AH Standby 24 Hours Alarm 5 Minutes 68:1 -1 is � W BI: 1 -4 • • • 1 0.145 Device Type Amp:; /Dev Amps NACs - 1.101 Total • • C 1e 2 Y 1 0 0 0 2 P2R /P2VV 75cd Mid 157 5 0 0 0 • t • U fl • v • � V• U Y 1 • r u, u 1.101 0 0 0 0 0 1.101 Wire Guage 14 14 14 14 rr•• 4uW•• This booster his 4 circuits Oh n/K 1 3.07 3.07 3.07 3.07 3.07 •fr•r 210 • 0 • 0 0 Voltag -p Drop 1.42 0.00 0.00 0.00 N/A 0.00 Voltage Drop and Battery Power Supply Model FCPS -24FS6 Calculations rF•Y r Uri Booster BI AH Standby 24 Hours Alarm 5 Minutes 68:1 -1 68:1 -2 B8:1 -3 BI: 1 -4 CPS-24FS6 0.065 0.145 Device Type Amp:; /Dev Amps NACs - 1.101 Total SR /SVV 75cd 1 E 8 2 0 0 0 0 0 2 P2R /P2VV 75cd Mid 157 5 0 0 0 0 0 5 * Battery provided may be larger than the size listed depending on availability at the time of installation. Large batteries may need external battery cabinet. Total Crevices 7 0 0 0 0 0 7 Total (;urrent 1.101 0 0 0 0 0 1.101 Wire Guage 14 14 14 14 14 14 This booster his 4 circuits Oh n/K 3.07 3.07 3.07 3.07 3.07 3.07 Estimated Length 210 0 0 0 0 0 Voltag -p Drop 1.42 0.00 0.00 0.00 N/A 0.00 Max Charging Capacity 18.00 AH Standby 24 Hours Alarm 5 Minutes O Standby Alarm Max Current for NAC 3.00 Amps CPS-24FS6 0.065 0.145 Max Current for AUX Ckt 1.70 Amps NACs - 1.101 Max Panel Current Output 6.00 Amps Aux Pwr - - i--i Totals 0.065 1.246 Start Voltage 20.40 Volts AH Calculations 1 1.560 0.104 Min Voltage Allowed 1600 Volts Total AH 1.664 Max Voltage Drop Allowed 4.40 Volts Derate Factor 1.20 lAdjusted Minimum 1.997 1 * Battery Provided 7AH Batteries Mount Inside Booster Cabinet SCOPE OF WORK: THIS PROJECT INVOLVES THE INSTALLATION OF NEW FIRE ALARM DEVICES IN THE RETAIL TENANT SPACE OF AN EXISTING 4 STORY MIXED USE FACILITY WITH AN EXISTING FCI E3 SERIES FIRE ALARM CONTROL PANEL. A NEW REMOTE POWER SUPPLY IS INCLUDED IN THIS PROJECT SPECIFICALLY TO DRIVE THE NEW STROBES AND HORN STROBES. THE NEW SMOKE DETECTORS, DUCT DETECTORS, PULL STATIONS AND REMOTE RELAYS ARE TO BE CONNECTED TO THE EXISTING SLC IF THERE IS SPACE AVAILADLE ON THE CIRCUITS. THE REMOTE RELAY AND THE MONITOR MODULES ARE TO BE PROGRAMMED TO ACTIVATE AND MONITOR THE NEW POWER SUPPLY. t SHALL RC A CcNTRA1 FICATE NOTE: BATTERY CALCULATION FOR FACP SHOWS EXISTING LOAD ALONG WITH NEW DEVICES LOAD TO SHOW THAT FACP WILL NOT BE OVERLOAD AS A RESULT OF THE NEW DEVICES BEING ADDED. i i+l10E• A CI✓RTI AT STATION SIER OR PLACARD SlA1. A5 P R NFpA 72 FIW& IgVt ECIV4, FIRE ALARM SYSTEM TO BE INSTALLED IN ACCORDANCE W1 NFPA 72; 70 ;101 Do 1AMI -13h0E CoUtiTY FIRE R EPA�r+ T , roa. pErm'"'r- ,�;, VYATL*R MAIN t T• „-.., '.�1>v� : ✓ SAS Or' OCC'JPANn PROVIOr,D AT TTi..., J hH�St -3 BE r 1 -7 F F S 1 -2 R R S f 1 -6 1 -5 1 -4 1 -1 A S S 1 -I 1 -3 e 75CD 75CD 75CD 75CD 75CC 75CD 75CD 18:1 -1 89:1 -2 18:1 -3 18 :1 -4 111118:11-5 18:1 -6 19:1 -7 TO EXISTING FCI -E3 SERIES FIRE ALARM CONTROL PANEL LOCATED IN MAIN OFFICE. FCPS 24FS6 D POWER SUPPLY (#8 NEW) 3 #12 THHN TO 120VAC CKT. WREAKER# (20AMP MAX.) FIRE ALARM RISER DIAGRAM_ SCALE: 1/8" = 11.0.' 0 0i V U • O-Q. JLR5Y!S10NS • W L f: W U lr •Y• to • •UWi • r • r rr • • f • U) O co Co O W c) C) F W x r- Lo OC) 0 i--i PQ U) w O O to CD U p E- O 1 Project No: 40094 4 t i I chi J LL ❑ o �- g � !`oN' 0� � N V 0 w U') U) ° LL- =� w °' �0 ❑ � c zN t7 LLJ r) W <Z WM O LLM Z QUALIFIER Name: Jorge Alvarez License #: EC13005215 U Z 4 0 W Cn W Z� CO (0 wF- 2 ENGINEER ,1 R 4 5 ..w. } Seal Drawn By: R.D. Date: 04/17/14 Scale: Sheet Title: FIRST FLOOR EShe et No' FA -01