14-196-001FIRE SPRINKLER SYSTEM PLAN. 0 z SCALE: 1/4!'= F - 0" 3 1 2 I NOTE: • ARMOVERS GREATER THAN COUPONS TO BE ATTACHED 12" IN LENGTH SHALL BE SUPPORTED BY A HANGER. TO ALL NEW MECH TEES. SCHEDULE 1. NEW MECH —TYPE TEE or SCREWED TEE 2. BRANCHLINE/ MAIN 3. ARMOVER.* NEW CONNECTION DETAIL N.T.S. SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) 7— m 1" NPT, Ij NOMINAL FACE OF MAKE -IN: ORDER LENGTHS: SPRINKLER 9116" O" to 45 -1/4" FITTING 3 -5/8" DIA (14,3 mm) (0,0 to 1149,4 mm) (92,1 mm) IN 1/4" (6,4 mm) I I INCREMENTS FACE OF 2-3/4" DIX CEILING ( I mm) I FOR ORDER LENGTHS 3/4 < 3 -1/4" (82,6 mm): *ESCUTCHEON 41/16±1/8" (103,2±3,2 mm) * WILL PERMIT -or- ±5/8"(15,9 mm) FOR ORDER LENGTHS ADJUSTMENT 2:3-1/4" (82,6 mm): 4- 13/16±1/8" (122,2±3,2 mm) ** ** ESCUTCHEON FREEZER /COOLER WILL PERMIT CEILING ! ±1 -3/8" (34,9 mm) STEEL PIPE EXCEPT ADJUSTMENT DRY PENDENT SPRINKLER DETAIL N.T.S. OPEN -CELL POLYETHYLENE FOAM BACKER ROD SUPPLY FROM WET 3/4 PIPE SPRINKLER SYSTEM 1 1/4 TEE WITH PLUG 2 1" DRY N SPRINKLER DROP i DOW CORNING 739 PLASTIC ADHESIVE Z r w FREEZER /COOLER 12 CEILING ! Z STEEL PIPE EXCEPT U'. L - THREADED LIGHTWALL N/A SPRINKLER CUP J GLOBE MODEL GL5681 / TYCO MODEL TY3555/ COVER PLATE VICTAULIC V3301 21" CONCEALED 200-F DRY zg �rvu �uo� n iu nuiv�� PENDENT SPRINKLER OPTION A (NO SUBSTITUTIONS) OPTION B NOTE: CONTRACTOR TO SEAL DRY PENDENT SPRINKLERS AT FREEZER /COOLER USING ONE OF THE OPTIONS ABOVE. NO OTHER SEALANTS ARE PERMITTED. CL D SCHEDULE 1. BRANCHLINE OR MAIN 2. TEE 3. ARMOVER.* 4. 1" 90' ELL OR TEE 5. 1" DROP 6. PENDENT FIRE SPRINKLER * ARMOVERS GREATER THAN 12" IN LENGTH SHALL BE SUPPORTED BY A HANGER. ARM — OVER & DROP DETAIL N.T.S. ROOF DECK STEEL I BEAM OR BAR JOIST PIPE RING TOP BEAM CLAMP (w /lock nut) ALL THREADED HANGER ROD HANGER ROD SIZES UP TO 4" PIPE: 3/8" DIA. r: .•� . A .� SLAB 3/8" ROD 3/8" POWDER COUPLING DRIVEN STUD ALL THREADED HANGER ROD NUT PIPE RING 4 MAXIMUM HANGER SPACING (FT.) PIPE SIZE (IN.) 3/4 1 1 1/4 1 1/2 2 THREADED LIGHTWALL STEEL PIPE N/A 12 12 12 12 STEEL PIPE EXCEPT L - THREADED LIGHTWALL N/A 12 12 15 15 ALL HANGERS AT CEILING PENDENT END OF LINE SPRINKLERS SHALL PREVENT BAR JOIST 12" MAX. UPWARD MOVEMENT OF PIPE. HANGERS AT ARMOVERS TO CEILING PENDENT SPRINKLERS SHALL PREVENT UPWARD MOVEMENT OF PIPE. UPRIGHT F.S. HEAD PIPE SUPPORT DETAIL N.T.S. IINP PIPIWr. BEAM BEYOND MAIN PIPING UPRIGHT HEAD/ STEEL STRUCTURE S) z z 0 W y - - -- - as - -- - � Vl z w a J N Q NFPA 13 - 2007 EDITION 24.2 ACCEPTANCE REQUIREMENTS. 24.2.1 - HYDROSTATIC TESTS. 24.2.1.1 - UNLESS PERMITTED BY 24.2.1.2 THROUGH 24.2.1.6, ALL PIPING AND ATTACHED APPURTENANCES SUBJECTED TO SYSTEM WORKING PRESSURE SHALL BE HYDROSTATICALLY TESTED AT 200 PSI (13.8 BAR) AND SHALL MAINTAIN THAT PRESSURE WITHOUT LOSS FOR 2 HOURS. 24.2.1.2 PORTIONS OF SYSTEMS NORMALLY SUBJECTED TO SYSTEM WORKING PRESSURES IN EXCESS OF 150 PSI (10.4 BAR) SHALL BE TESTED AS DESCRIBED IN 24.2.2.1 AT A PRESSURE OF 50 PSI (3.5 BAR) IN EXCESS OF SYSTEM WORKING PRESSURE. 24.2.1.3 WHERE COLD WEATHER WILL NOT PERMIT TESTING WITH WATER, AN INTERIM AIR TEST SHALL BE PERMITTED TO BE CONDUCTED AS DESCRIBED IN 24.2.3. 24.2.1.4 MODIFICATIONS AFFECTING 20 OR FEWER SPRINKLERS SHALL NOT REQUIRE TESTING IN EXCESS OF SYSTEM WORKING PRESSURE. 24.2.1.5 WHERE ADDITION OR MODIFICATION IS MADE TO AN EXISTING SYSTEM AFFECTING MORE THAN 20 SPRINKLERS, THE NEW PORTION SHALL BE ISOLATED AND TESTED AT NOT LESS THAN 200 PSI (13.8 BAR) FOR 2 HOURS. 24.2.1.6 MODIFICATIONS THAT CANNOT BE ISOLATED, SUCH AS RELOCATED DROPS, SHALL NOT REQUIRE TESTING IN EXCESS OF SYSTEM WORKING PRESSURE. 2009 FLORIDA STATUTES/ CHAPTER 633/ FIRE PREVENTION AND CONTROL PERSONS CERTIFIED AS A CONTRACTOR I, CONTRACTOR II, OR CONTRACTOR IV UNDER THIS CHAPTER MAY DESIGN FIRE PROTECTION SYSTEMS OF 49 OR FEWER SPRINKLERS, AND MAY DESIGN THE ALTERATION OF AN EXISTING FIRE SPRINKLER SYSTEM IF THE ALTERATION CONSISTS OF THE RELOCATION, ADDITION, OR DELETION OF NOT MORE THAN 49 SPRINKLERS, NOTWITHSTANDING THE SIZE OF THE EXISTING FIRE SPRINKLER SYSTEM. CONTRACTOR- DEVELOPED PLANS MAY NOT BE REQUIRED BY ANY LOCAL PERMITTING AUTHORITY TO BE SEALED BY A REGISTERED PROFESSIONAL ENGINEER. GENERAL NOTES 1 - ALL PIPING, HEADS, HANGERS AND SYSTEM COMPONENTS TO BE SPACED AND INSTALLED AS PER THE LATEST APPLICABLE EDITION OF NFPA -13, APPROVING AUTHORITY HAVING JURISDICTION AND ALL STATE AND LOCAL CODES. 2 - SPACING FOR FIRE SPRINKLER HEADS IN LIGHT HAZARD AREAS (OFFICE AREAS) TO BE 225 SQ. FT. MAXIMUM PER HEAD. SPACING FOR ORDINARY HAZARD AREAS (STORAGE AREAS) TO BE 130 SQ. FT. MAXIMUM PER HEAD. 3 - PIPING TO BE INSTALLED CONCEALED ABOVE DROPPED CEILINGS EXCEPT AS NOTED IN EXPOSED CEILING AREAS. 4 - LINE PIPING 1" - 2" TO BE THREADED "XL" WITH SCREWED FITTINGS OR APPROVED ACCEPTABLE EQUAL. 5 - HEAD - GAURDS TO BE PROVIDED ON EXPOSED SPRINKLERS IN JANITOR CLOSETS. 6 - PROVIDE FIRE STOPPING ON ALL PENETRATIONS THROUGH FIRE WALLS. SCOPE OF WORK: EXISTING FULLY PROTECTED MERCHANTILE SPACE. ADD/ RELOCATE FIRE SPRINKLER HEADS AS NEEDED TO OBTAIN PROPER COVERAGE DUE TO NEW PARTITION/ CEILING LAYOUT. APPROVED MIMM -D.ADE C S.T� J T ' FIlUE I; Ert-`r' RTMENT BLDG. FIR E AURM FIRE SUP RE SION WATER MAIN M. DATE: % BY: l 1 SED P LANL MDFR __-Z H M W Gi 41 F.. zz 3 Q \ U Q = N W y Q q r' z g r Qj In v im "9 rl m E. v - -6 } E> O _ 'n o O 'Q O 00 — U U ,o L , I CID 3 O L/) ro J 441ir► O C) CD U Q3 k�O ro Z tO 0 j o Ln Q• • Lull. T r x4 7� 7� U w a r� FP -1 OF 1 N� W L - I� CrJ W cq .. o co Pr_4 c O FP -1 OF 1