Loading...
14-196-001FIRE SPRINKLER SYSTEM PLAN _ 0 z SCALL: 1/4" = I " - U 3) - I;1 • ARMOVERS GREATER THAN 12" IN LENGTH SHALL BE SUPPORTED BY A HANGER. 0;4 NOTE: COUPONS TO BE ATTACHED TO ALL NEW MECH TEES. SCHEDULE 1. NEW MECH -TYPE TEE or SCREWED TEE 2. BRANCHLINE/ MAIN 3. ARMOVER.• NEW CONNECTION DETAIL N.T.S. q SCHEDULE 1. BRANCHLINE OR MAIN 2. TEE 3. ARMOVER.' 4. 1" 90' ELL OR TEE 5. 1" DROP 6. PENDENT FIRE SPRINKLER • ARMOVERS GREATER THAN Li __s 12 "IN LENGTH SHALL BE SUPPORTED BY A HANGER. 1 ARM - OVER & DROP DETAIL N.T.S. SPRINKLER FITTING (REFER TO DESIGN CRITERIA SE( -TION) - L i I ROOF DECK 1" NPT, NOMINAL FACE OF MAKE -IN: ORDER LENGTHS: SPRINKLER 9/16" 0 "to 45 -1/4" FITTING 3 -5/8" DIA. (14,3 mm) (0,0 to 1149,4 mm) (92,1 mm) BAR JOIST 12" MAX. IN 1/4" (6,4 mm) I I INCREMENTS FACE OF 2 -3/4" DIA• UPRIGHT F.S. HEAD CEILING r (69,9 mm) FOR 3-1/4"(82,6 mm): *ESCUTCHEON RISER NIVMAIN LINE PIPING 41/16±1/8" (103,2±3,2 mm) * WILL PERMIT -or- ±5/8" (15,9 mm) BEAM BEYOND FOR ORDER LENGTHS ADJUSTMENT PIPING 2:3-1/4"(82,6 mm): 4- 13/16±1/8" (122,2±3,2 mm) ** ** ESCUTCHEON WILL PERMIT ±1-3/8"(34,9 mm) ADJUSTMENT DRY PENDENT SPRINKLER DETAIL UPRIGHT HEAD/ STEEL STRUCTURE N.T.S. N.T.S. SUPPLY FROM WET PIPE SPRINKLER SYSTEM TEE WITH PLUG DRY SYMBOL SPRINKLER DROP SIN OPEN -CELL DOW CORNING 739 � ~ POLYETHYLENE PLASTIC ADHESIVE z FOAM BACKER ROD '- FREEZER /COOLER 0 CEILING z 1/2 TY323 TYCO U TY -FRB STAND. COV. PENDENT I 5.6 SPRINKLER CUP GLOBE MODEL GL5681 / TYCO MODEL TY3555/ COVER PLATE VICTAULIC V3301 21 CONCEALED 200-F DRY "" " "` 21 [NU sUdb n ILI (TUNS) PENDENT SPRINKLER OPTION A (NO SUBSTITUTIONS) OPTION B NOTE: CONTRACTOR TO SEAL DRY PENDENT SPRINKLERS AT FREEZER /CC)OLER USING ONE OF THE OPTIONS ABOVE. NO OTHER SEALANTS ARE PERMITTED. n 1 FREEZER COOLER DRY' PENDENT SPRINKLER NTS 01.28.11 F19 S) FIRE SPRINKLER HEAD LEGEND SYMBOL SIZE SIN MAKE FINISH MODEL TYPE TEMP K- FACTOR RESPONSE MAX. SPACING TOTAL Q 1/2 TY323 TYCO CHROME TY -FRB STAND. COV. PENDENT 155 5.6 QR AS PER NFPA REQ. 13 Q 1/2 TY3151 TYCO BRASS TY -B STAND. COV. UPRIGHT 155 5.6 SR AS PER NFPA REQ. 00 1/2 TY3331 TYCO CHROME TY -FRB STAND. COV. SIDEWALL 155 5.6 QR AS PER NFPA REQ. 00 1/2 GL5635 GLOBE CHROME GL DRY PENDENT 200 5.6 QR AS PER NFPA REQ. 02 -.o O TOTAL SPRINKLERS REQUIRED ON JOB 15 NOTES 1. ALL FIRE SPRINKLERS SHALL HAVE A U.L. APPROVED CORROSION RESISTANT COATING WHERE EXPOSED TO OUTSIDE AIR, CHEMICALS, MOISTURE, OR OTHER CORROSIVE VAPORS SUFFICIENT TO CAUSE CORROSION OF SUCH DEVICES. O EXISTING UPRIGHT FIRE SPRINKLER HEAD TO REMAIN AS IS 0 EXISTING FIRE SPRINKLER HEAD TO BE REMOVED/ PLUGGED —) EXISTING FIRE SPRINKLER HEAD TO BE REMOVED/ RELOCATED NEW FIRE SPRINKLER SYSTEM PIPING - - - - EXISTING FIRE SPRINKLER SYSTEM PIPING STEEL I BEAM TOP BEAM CLAMP ]SLAB OR BAR JOIST (w /lock nut) •a ' 3/8" ROD 3/8" POWDER COUPLING DRIVEN STUD ALL THREADED ALL THREADED HANGER ROD HANGER ROD NUT PIPE RING PIPE RING HANGER ROD SIZES UP TO 4" PIPE: 3/8" DIA. MAXIMUM HANGER SPACING (FT.) PIPE SIZE (IN.) 3/4 1 1 1/4 1 1/2 2 THREADED LIGHTWALL STEEL PIPE N/A 12 12 12 12 STEEL PIPE EXCEPT THREADED LIGHTWALL N/A 12 12 15 15 ALL HANGERS AT CEILING PENDENT END OF LINE SPRINKLERS SHALL PREVENT UPWARD MOVEMENT OF PIPE. HANGERS AT ARMOVERS TO CEILING PENDENT SPRINKLERS SHALL PREVENT UPWARD MOVEMENT OF PIPE. PIPE SUPPORT DETAIL N.T.S. NFPA 13 - 2007 EDITION 24.2 ACCEPTANCE REQUIREMENTS. 24.2.1 - HYDROSTATIC TESTS. 24.2.1.1 - UNLESS PERMITTED BY 24.2.1.2 THROUGH 24.2.1.6, ALL PIPING AND ATTACHED APPURTENANCES SUBJECTED TO SYSTEM WORKING PRESSURE SHALL BE HYDROSTATICALLY TESTED AT 200 PSI (13.8 BAR) AND SHALL MAINTAIN THAT PRESSURE WITHOUT LOSS FOR 2 HOURS. 24.2.1.2 PORTIONS OF SYSTEMS NORMALLY SUBJECTED TO SYSTEM WORKING PRESSURES IN EXCESS OF 150 PSI (10.4 BAR) SHALL BE TESTED AS DESCRIBED IN 24.2.2.1 AT A PRESSURE OF 50 PSI (3.5 BAR) IN EXCESS OF SYSTEM WORKING PRESSURE. 24.2.1.3 WHERE COLD WEATHER WILL NOT PERMIT TESTING WITH WATER, AN INTERIM AIR TEST SHALL BE PERMITTED TO BE CONDUCTED AS DESCRIBED IN 24.2.3. 24.2.1.4 MODIFICATIONS AFFECTING 20 OR FEWER SPRINKLERS SHALL NOT REQUIRE TESTING IN EXCESS OF SYSTEM WORKING PRESSURE. 24.2.1.5 WHERE ADDITION OR MODIFICATION IS MADE TO AN EXISTING SYSTEM AFFECTING MORE THAN 20 SPRINKLERS, THE NEW PORTION SHALL BE ISOLATED AND TESTED AT NOT LESS THAN 200 PSI (13.8 BAR) FOR 2 HOURS. 24.2.1.6 MODIFICATIONS THAT CANNOT BE ISOLATED, SUCH AS RELOCATED DROPS, SHALL NOT REQUIRE TESTING IN EXCESS OF SYSTEM WORKING PRESSURE. 2009 FLORIDA STATUTES/ CHAPTER 633/ FIRE PREVENTION AND CONTROL PERSONS CERTIFIED AS A CONTRACTOR I, CONTRACTOR II, OR CONTRACTOR IV UNDER THIS CHAPTER MAY DESIGN FIRE PROTECTION SYSTEMS OF 49 OR FEWER SPRINKLERS, AND MAY DESIGN THE ALTERATION OF AN EXISTING FIRE SPRINKLER SYSTEM IF THE ALTERATION CONSISTS OF THE RELOCATION, ADDITION, OR DELETION OF NOT MORE THAN 49 SPRINKLERS, NOTWITHSTANDING THE SIZE OF THE EXISTING FIRE SPRINKLER SYSTEM. CONTRACTOR - DEVELOPED PLANS MAY NOT BE REQUIRED BY ANY LOCAL PERMITTING AUTHORITY TO BE SEALED BY A REGISTERED PROFESSIONAL ENGINEER. GENERAL NOTES 1 - ALL PIPING, HEADS, HANGERS AND SYSTEM COMPONENTS TO BE SPACED AND INSTALLED AS PER THE LATEST APPLICABLE EDITION OF NFPA -13, APPROVING AUTHORITY HAVING JURISDICTION AND ALL STATE AND LOCAL CODES. 2 - SPACING FOR FIRE SPRINKLER HEADS IN LIGHT HAZARD AREAS (OFFICE AREAS) TO BE 225 SQ. FT. MAXIMUM PER HEAD. SPACING FOR ORDINARY HAZARD AREAS (STORAGE AREAS) TO BE 130 SQ. FT. MAXIMUM PER HEAD. 3 - PIPING TO BE INSTALLED CONCEALED ABOVE DROPPED CEILINGS EXCEPT AS NOTED IN EXPOSED CEILING AREAS. 4 - LINE PIPING 1" - 2" TO BE THREADED "XL" WITH SCREWED FITTINGS OR APPROVED ACCEPTABLE EQUAL. 5 - HEAD - GAURDS TO BE PROVIDED ON EXPOSED SPRINKLERS IN JANITOR CLOSETS 6 - PROVIDE FIRE STOPPING ON ALL PENETRATIONS THROUGH FIRE WALLS. SCOPE OF WORK: EXISTING FULLY PROTECTED MERCHANTILE SPACE. ADD/ RELOCATE FIRE SPRINKLER HEADS AS NEEDED TO OBTAIN PROPER COVERAGE DUE TO NEW PARTITION/ CEILING LAYOUT. INSPECTOR AS PER NFPA 13 20p ;?EDIT1101.' SECTION N,ODIFICATIONS T! I I C;;,.L �, �; D, S AS RELOCATES, DROPS S' •. ISOL .AT;EJ, SUCH ,N EXCESS OF SYSTEM, ;� DLL NOT REQUIRE TESTING V,, 0, ,K,'NG PRESSURE ?IRLEE OF PA RIME NT [3LTZs. ,- cRt,fl i FIRE ALARM___` FIRE SU 'FREE SIOi' 16VAATER MAIN EXT._ DATE: l4 BY: z- 0 V .Sh W I I I lJ F- A a o Z Q N N Z 3a = Z w Q� m rn ,;4- W CU �+-- c O �1 rl m ___4 `�. 0 V .Sh W I I I lJ F- A a o Z Q N N Z 3a = U LI O Z w Q� m rn ,;4- W CU �+-- c O D rl m ___4 `�. > -D O E O Q +0' O vJ UU1'o1� t-n w —oL/I 3 E W J O -.o O LU 2 Y Q q) O tD a �-, z N F—� V/ W cc LL U LI O Irk v� p n : FP -1 OF 1 w W � ___4 w � � o co a p �-, N F—� Irk v� p n : FP -1 OF 1