13-1358-046� r Y z C N r C t U J J U U r a 0 m N U GENERAL PLUMBING NOTES I ALL WORK SHALL CONFORM WITH FLORIDA BUILDING CODE 2010 4 INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST EDITION (F,B.C. 2010), FEDERAL ORDINANCES GOVERNING THE CLASS WORKMANLIKE MANNER THE OWNER RESERVES THE INSTALLATION OF THE PLUMBING SYSTEM IF WORK AS LAID RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ITEMS WHICH, OUT, INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS IN HIS OPINION, DO NOT PRESENT A NEAT AND WORKMANLIKE WITH LOCAL ORDINANCES, BUILDING CODES AND REGULATIONS, APPEARANCE REMOVAL AND REPLACEMENT IS TO BE DONE THE CONTRACTOR SHALL REPC," ,T IN WRITING TO THE IMMEDIATELY WHEN DIRECTED BY THE OWNER IN WRITING, AT ARCHITECT/ENGINEER BEFORE SUBMITTING A BI D. THE THE SOLE EXPENSE OF CONTRACT OR ARCHITECT/ENGINEER WILL THEN ISSUE INSTRUCTIONS AS HOW TO PROCEED, S START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS GATE VALVE ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO 2 THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT SUITABILITY OF THE WORK OF OTHER TRADES OR OTHER NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE CONTRACTORS TO RECEIVE HIS WORK THIS CONTRACTOR MINOR ITEMS UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE SHALL REMOVE AND REPLACE, AT HIS EXPENSE, ALL PLUMBING STRUCTURAL. ARCHITECTURAL AND SITE CONDITIONS SHALL WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF GOVERN THE EXACT LOCATIONS. CONTRACTOR SHALL FOLLOW INTERFERENCE WITH OTHER TRADES DRAWINGS IN LAYING OUT WORK, CHECK DRAWINGS OF ALL FD TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED 65, THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE, AND MAINTAIN MAXIMUM HEAD ROOM, AND SPACE CONDITIONS FEES, PERMITS, ASSOCIATION DUES, ROYALTIES AND TAXES OF AT ALL POINTS. WHERE HEAD ROOM, OR SPACE CONDITIONS WHATEVER NATURE SHALL APPLY TO THIS WORK HE SHALL ALSO APPEAR INADEQUATE ARCHITECT/ ENGINEER SHALL BE NOTIFIED BEFORE PROCEEDING WITH INSTALLATION. THIS PAID ALL THE INSPECTION FEES AS MAY REQUIRED BY LAW OR ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY CONTRACTOR SHALL WITHOUT EXTRA CHARGE, MAKE FIELD DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF LAWS MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT RULES OR ORDINANCES WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION 1 OF THE WORK. T PROVIDE MEANS "FURNISH AND INSTALL!. S EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBMITTING A BID, S. DO A COMPLETE JOB, EVERYTHING CONNECTED, READY FOR USE CONTRACTOR WILL BE REQUIRED TO FURNISH, INSTALL AND /OR CONNECT WITH APPROPRIATE SERVICES ALL PLUMBING ITEMS 9• SHOP DRAWINGS: CONTRACTOR SHALL FURNISH THE ENGINEER SHOWN ON ANY OF THE ARCHITECTURAL AIR CONDITIONING, F OR SHOP DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE FOR APPROVAL ELECTRICAL AND SPRINKLER DRAWINGS WITHOUT ADDITIONAL 3" EXPENSE TO THE OWNER IF DISCREPANCIES, CONFLICTS, 1D. AT COMPLETION OF JOB THE PLUMBING CONTRACTOR SHALL INTERFERENCE OR OMISSIONS OCCUR BETWEEN DRAWINGS, GIVE THE OWNER AN AS -BUILT SET OF REPRODUCIBLE SEPIAS NOTIFY IN WRITING THE ARCHITECT/ ENGINEER IN AMPLE TIME SHOWING THE EXACT LOCATION OF ALL INSTALLATIONS TO PERMIT REVISIONS BEFORE THE BIDS ARE SUBMITTED. -- PLUMBING SYMBOL LEGEND SYMBOL DESCRIPTION Irwlwli--n rinnco I yr .- HAMMER ARRESTOR (HA) SHALL BE JOSAA ABSORBOTRON TYPE Na 75001 OR APPROVED EQUAL A WATER HA SHALL BE INSTALLED WHERE QUICK- CLOSING VALVES ARE UTILIZED, UNLESS OTHERWISE APPROVED. SHALL BE LOCATED WITHIN AN EFFECTIVE RANGE OF THE QUICK-CLOSING VAI VF. It PLUMBING CONTRACTOR SHALL PRESSURE TEST ALL PIPING AS REQUIRED BY CODE TEST SHALL BE WITNESSED AND APPROVED BY PROPER AUTHORITIES. 12 THE PLUMBING CONTRACTOR SHALL WARRANT ALL WORKMANSHIP AND MATERIALS FOR ONE YEAR FROM THE DATE OF FINAL WORK ACCEPTANCE BY OWNER ANY BREAKDOWN OCCURRING IN FIRST YEAR SHALL BE REPAIRED AT NO EXPENSE TO THE OWNER 13. PROVIDE BATHROOM FIXTURES AS SPECIFIED OR AS SELECTED BY OWNER AND TO COMPLY W/FB.C2001 SPECIALLY CHAPTER 1t 14, PROVIDE SHUTOFF VALVE FOR EACH FIXTURE 15. WHEREVER NOT SIMILAR METALS ARE TO BE JOINED, A DIELECTRIC FITTING SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES 16 PLUMBING CONTRACTOR SHALL PROVIDE AIR CONDITIONING CONDENSATE DRAIN AND TRAP, SEE AIR CONDITIONING PLANS FOR LOCATION OF UNITS AND DRAINS, 17. ALL SANITARY FITTINGS SHALL BE DIRECTIONAL TYPE 16. MATERIALS A COLD WATER PIPING DOWNSTREAM OF WATER METER SHALL BE PVC -CPVC BELOW GROUND AND ABOVE GROUND. B COLD WATER PIPES INSIDE OF SLAB SHALL BE PVC -CPVC INSTALL INSIDE POLYETHYLENE CONDUIT. NO JOINTS PERMITTED INSIDE SLAB C. SANITARY WASTE AND VENT 4 "0 AND SMALLER SHALL BE RVC, SCHEDULE 40 S STORM LINES INSIDE BUILDING SHALL BE RVC. SCHEDULE 40 E IN COASTAL AREAS ALL SANITARY AND STORM PIPING OUTSIDE OF BUILDING SHALL BE SCHEDULE 40, PVC. F. CONDENSATE DRAIN PIPE SHALL BE SCHEDULE 40, PVC PIPE AND FITTINGS G. WATER HEATER RELIEF AND DRAIN LINE SHALL BE TYPE "L" CU, MIN, 3/4" DIA RESTROOM FIXTURE CONNECTION SCHEDULE NEW SANITARY WASTE LINE — — — — — — — — SANITARY VENT LINE - - NEW COLD WATER LINE - - - - NEW HOT WATER LINE — — — — — EXISTING SANITARY DRAIN LAVATORY EXISTING WATER LINE QD NEW GREASE DRAIN 013 CONDENSATE DRAIN LINE 1 GATE VALVE a 00 CLEANOUT FD FLOOR DRAIN Ct PIPE DOWN ECOLAB DISHWASHER POINT OF CONNECTION TO EXISTING VT.R VENT THRU ROOF E.W.H. ELECTRIC WATER HEATER FD FLOOR DRAIN CW COLD WATER HW HOT WATER F.U. FIXTURE UNITS Irwlwli--n rinnco I yr .- HAMMER ARRESTOR (HA) SHALL BE JOSAA ABSORBOTRON TYPE Na 75001 OR APPROVED EQUAL A WATER HA SHALL BE INSTALLED WHERE QUICK- CLOSING VALVES ARE UTILIZED, UNLESS OTHERWISE APPROVED. SHALL BE LOCATED WITHIN AN EFFECTIVE RANGE OF THE QUICK-CLOSING VAI VF. It PLUMBING CONTRACTOR SHALL PRESSURE TEST ALL PIPING AS REQUIRED BY CODE TEST SHALL BE WITNESSED AND APPROVED BY PROPER AUTHORITIES. 12 THE PLUMBING CONTRACTOR SHALL WARRANT ALL WORKMANSHIP AND MATERIALS FOR ONE YEAR FROM THE DATE OF FINAL WORK ACCEPTANCE BY OWNER ANY BREAKDOWN OCCURRING IN FIRST YEAR SHALL BE REPAIRED AT NO EXPENSE TO THE OWNER 13. PROVIDE BATHROOM FIXTURES AS SPECIFIED OR AS SELECTED BY OWNER AND TO COMPLY W/FB.C2001 SPECIALLY CHAPTER 1t 14, PROVIDE SHUTOFF VALVE FOR EACH FIXTURE 15. WHEREVER NOT SIMILAR METALS ARE TO BE JOINED, A DIELECTRIC FITTING SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES 16 PLUMBING CONTRACTOR SHALL PROVIDE AIR CONDITIONING CONDENSATE DRAIN AND TRAP, SEE AIR CONDITIONING PLANS FOR LOCATION OF UNITS AND DRAINS, 17. ALL SANITARY FITTINGS SHALL BE DIRECTIONAL TYPE 16. MATERIALS A COLD WATER PIPING DOWNSTREAM OF WATER METER SHALL BE PVC -CPVC BELOW GROUND AND ABOVE GROUND. B COLD WATER PIPES INSIDE OF SLAB SHALL BE PVC -CPVC INSTALL INSIDE POLYETHYLENE CONDUIT. NO JOINTS PERMITTED INSIDE SLAB C. SANITARY WASTE AND VENT 4 "0 AND SMALLER SHALL BE RVC, SCHEDULE 40 S STORM LINES INSIDE BUILDING SHALL BE RVC. SCHEDULE 40 E IN COASTAL AREAS ALL SANITARY AND STORM PIPING OUTSIDE OF BUILDING SHALL BE SCHEDULE 40, PVC. F. CONDENSATE DRAIN PIPE SHALL BE SCHEDULE 40, PVC PIPE AND FITTINGS G. WATER HEATER RELIEF AND DRAIN LINE SHALL BE TYPE "L" CU, MIN, 3/4" DIA RESTROOM FIXTURE CONNECTION SCHEDULE ITEM WASTE & SOIL (AS PER TABLE 700 WATER (AS PER TABLE 6045) COLD HOT WATER CLOSET 3" 1/2" - - LAVATORY 1 -1/4" 1/2" 1/2" * FLOOR DRAINS 3" 1 ICE MACHINE ICE 0 MATIC ICE0500HA 1/2" TO F.S. 1/2" * -- NOTE ALL TRAPS SHALL BE CONSISTENT W/ FIXTURE OUTLET SIZE NOTE: ALL FIXTURE SHALL COMPLY W/ F.B.C. TABLE 604,A L.VNa 1 KUL; 1 IUN NU 1 1'5 - ALL SANITARY PIPE 21/2'0 OR SMALLER SHALL RUN • Ve SLOPE PER LFT, 3' AND LARGER • 1/1" SLOPE PER LFT. ALL PIPES TO DISCHARGE MIR 12' FROM STRUCTURE ALL PLUMBING WATER DEVICE PROVIDE SHUT-OFF VALVE NO SPLICE ALLOWED UNDER SLAB. AI I VTR SHAT 1 RF rwTsU -T 1 RAIN CIF 111M FAf1AI n1w QC■A■AW)m um i EXISTING 1250 GAL GREASE TRAP, TO REMAIN. CONNECT WITH NEW 3" GREASE DRAIN AND PROVIDE 3" SANITARY DRAIN TO EXISTING SANITARY LATERAL CONNECT NEW 3" DRAIN TO EXISTING SANITARY LATERAL VERIFY EXACT LOCATION AND INCERT ELEVATION IN FIELD, CONNECT TO EXISTING STUB UP 4" SANITARY LINE VERIFY IN FIELD Fir%r%r SCALE: 114 * =1' -0" .' ITEM QTY. EQUIPMENT CATEGORY MODEL NO. WASTE COLD WATER HOT WATER 1 1 LAMARZOCCO GB -5 GB -5 3 GROUP -- 1/2" * W u w 7 1 ICE MACHINE ICE 0 MATIC ICE0500HA 1/2" TO F.S. 1/2" * -- 19 1 ECOLAB DISHWASHER ECOLAB APEXTSC SINGLE 2" -- 3/4" 23 1 BREWER BUNN MODEL DUAL TF DBC -- 1/2" * 27 1 HOT WATER DISPENSER BUNN MODEL H5E /H5X __ 1/2" * _- 31 1 HAND SINK KROWNE METAL HS -9 1 -1/4" 1/2" ELu 32 1 MOP SINK ZURN Z1996 -24 3" 3/4" 3/4" 33 1 3 COMPARTMENT SINK JOHN BOOS 3B16204 -2D18 3" -- -- 34 1 SINK FAUCET LL -- 3/4" 3/4" 35 1 BARISTA SINK EAGLE SR22- 22- 13.5 -1 1-1/2- 1/2- 1/2- 54 1 PITCHER RINSER EXPRESSO PART S STEAMING "x6 "x2" 1_1/2" 1/2" 1/2" PITCHER RINSER 6 55 1 SODA GUN _T __ 1/299 rWY 58 1 WATER FILTER 3M EXPRESSO ESP _- 1 /2" -_ NOTES 1. EQUIPMENT LAYOUT & SCHEDULE SHOWN IS PER KITCHEN CONSULTANT ................ REFER TO EQUIPMENT SHOP DRAWINGS PREPARED BY " ..........................." SHOP DRAWINGS FOR DETAILS. 2. WATER SUPPLY FROM ADJACENT WATER FILTER 3, REFER TO EQUIPMENT SHOP DRAWINGS FOR NOTES AND DETAILS. EXISTING 1250 GAL GREASE TRAP, TO REMAIN. CONNECT WITH NEW 3" GREASE DRAIN AND PROVIDE 3" SANITARY DRAIN TO EXISTING SANITARY LATERAL CONNECT NEW 3" DRAIN TO EXISTING SANITARY LATERAL VERIFY EXACT LOCATION AND INCERT ELEVATION IN FIELD, CONNECT TO EXISTING STUB UP 4" SANITARY LINE VERIFY IN FIELD Fir%r%r SCALE: 114 * =1' -0" .' • ! air 0; �•• r r r r � � Y " r ' ' rlrr. W u w v d r • • � �• c�� V • v @uiY r r u •rr o 06 G! •!• • ! r,urr., air �•• r r r r � � Y " r ' ' rlrr. W u w v d r • • � �• c�� V • v @uiY r r u •rr o M uJ .::. E r-I W O w Q O .� o ,. CL l: 4 :::} V W V 1 W •! i ELu j Y r u w • • u r J J r y r ! ! • W CL LL cli Lo Lo Q -4 w � cn c� ! rWY r!•r J Y • [ uriy • r 6 ! i Y ! r / ? U) u • uuVV • ,�•r * rU r u 7rYY r ! r r 0 U41r / W 0 w i U) co w J U co O } z [ Of O LL ow zo 0 Z2 LL= z� wa no �U Cnw o= z.2 Cw F-z ww W0f Do n= Ln2 -0 U i �_z zw LUO to z zo 0� TU F-_ �.(n o_ W_ a. 0 U fif 0 (L w w w r 0 F- 0 z U) U J J ui U w U LL maqueira LU CL gine,ering Cr O consultants INC. GG9.5595 ueiraxem U) of J • x r 4,. r.. R A2 n r SEP i'' 2ofi ROLANDO MAQUEIRA, PE FLORIDA PROFESSIONAL ENGINEER # PE 55432 (drawing data FLOOR PLAN PLUMBING ffproject number 11 [drawing scale AsShown [drawing date September • 1 gphase . �7 i Permit sheet number . f , V'f M N M r-I o M E r-I W O > o Q O .� o ,. CL o Ln , ELu O 0O U CL M cli Lo Lo Q -4 � cn x r 4,. r.. R A2 n r SEP i'' 2ofi ROLANDO MAQUEIRA, PE FLORIDA PROFESSIONAL ENGINEER # PE 55432 (drawing data FLOOR PLAN PLUMBING ffproject number 11 [drawing scale AsShown [drawing date September • 1 gphase . �7 i Permit sheet number . f ,