13-1358-039ELECTRICAL NOTES: 1 ALL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE 20011, FBC 2010 AND OTHER APPLICABLE CODES AND STANDARDS. 2 THE CONTRACTOR IS RESPONSIBLE FOR EVALUATING FIELD CONDITIONS BY VISITING THE SITE PRIOR TO COMMENCING/BIDDING WORK 3. THE CONTRACTOR SHALL SATISFACTORILY REPAIR/REPLACE EQUIPMENT OR PART OF STRUCTURE DAMAGED AS A RESULT OF HIS WORK SURFACES AND FINISHED AREAS SHALL BE RESTORED TO MATCH ADJACENT AREAS. 4, APPROVAL SHALL BE OBTAINED FROM THE ENGINEER PRIOR TO CUTTING OR DRILLING ANY STRUCTURAL SUPPORT MEMBER 5. ALL DEVICE BOXES SHALL BE INSTALLED FLUSH AND CONDUITS RUN CONCEALED IN FINISHED AREAS EXCEPT AS SPECIFICALLY SHOWN/NOTED OTHERWISE 6. WIRE SIZE SHALL BE X12 THHN/THWN STRANDED MINIMUM UNLESS OTHERWISE NOTED ON PLANS. 7 ALL CONDUCTORS SHALL BE COPPER 8. ALL CONDUCTORS SHALL BE RUN IN CONDUIT (METALLIC TYPE). IF PVC SCHEDULE 40 IS USED FOR UNDERGROUND FEEDERS ONLY, AN EQUIPMENT GROUND CONDUCTOR SIZED IN ACCORDANCE WITH NEC 250 -95 MUST BE INSTALLED AND CONDUIT SIZE INCREASED AS REQUIRED, 9. ALL MATERIAL MUST BE UL APPROVED. 1(1 ALL BRANCH CIRCUITS MUST BE PROPERLY PHASE BALANCED. 11, CONTRACTOR SHALL SEAL ALL FLOOR OPENINGS WITH A FIRE SEAL SIMILAR TO 3M FIRE DAM 15Q 12 ALL EMPTY CONDUITS TO BE PROVIDED WITH NYLON PULL STRINGS 13. FUSES SHALL BE DUAL ELEMENT, TIME DELAY TYPE UNLESS OTHERWISE NOTED. 14 ALL LUMINARIES SHALL BE PROPERLY SUPPORTED IN `ACCORDANCE WITH CEILING SYSTEM MANUFACTURER RECOMMENDATIONS AND LOCAL CODE REQUIREMENTS 15. RISERS ARE DIAGRAMMATIC ONLY. THEY DO NOT SHOW EVERY BEND REQUIRED FOR THE INSTALLATION. 16. THIS DRAWING IS A GUIDE FOR THE INSTALLATION OF ELECTRICAL SERVICE THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE A FUNCTIONING SYSTEM 17. ALL CABLES SHALL BE RUN WITHOUT SPLICES EXCEPT OTHERWISE INDICATED. 18. ALL PULL AND JUNCTION BOXES SHALL BE ACCESSIBLE AT ALL TIMES. 19. EXACT POINT AND METHODS OF CONNECTION SHALL BE DETERMINED IN FIELD. 2Q ALL WORK SHALL BE DONE IN A NEAT WORKMANLIKE MANNER 21 NEC (203) 517 :0 NEED ISOLATED GREEN X12 CONDUCTOR FROM ALL PATIENT CARE/EXAM ROOM OUTLETS FOR PATIENT CARE TO THE ELECTRICAL PANEL 22 AT EXAM ROOMS FOR PATIENT CARE USE HOSPITAL GRADE RECEPTACLES FOR RECEPTACLES USED FOR THIS PURPOSE 23, IF RUNING MULTTBRANCH CIRCUITS IN SAME CONDUIT, MUST USE INDEPENDANT. NEUTRALS OR SHOW 2 POLE 3 POLE BREAKERS AT ELECTRICAL PANEL RECOMMEND TO USE INDIVIDUAL NEUTRALS FOR EACH CIRCUIT. FIRE ALARM LEGEND F❑ MANUAL PULL STATION MOUNTED AT 4&' AFF. SL STROBE LIGHT MOUNTED AT 80" AFF, 75 cd UNO. FH HORN MOUNTED AT W AFF. IJ DUCT DETECTOR REMOTE TROUBLE / ALARM INDICATOR COMBINATION HORN / STROBE MOUNTED AT 800 AFF, 75 cd UNO. SD SMOKE DETECTOR SUFFIX 0EL' INDICATES WITH ELEVATOR RECALL FUNCTION. HD HEAT DETECTOR SUFFIX "EL' INDICATES WITH ELEVATOR RECALL FUNCTION. DD DUCT DETECTOR FFA—C-Pl FIRE ALARM CONTROL PANEL FAC FIRE ALARM COMMUNICATOR ANN FIRE ALARM REMOTE ANNUNCIATOR PANEL SPOT COFFEE NEW 4 #3 &1#6(G) COPPER IN 1 -1/2" COND. SUB PANEL PANEL PANEL uAu w uLu SECT II SECT I NEW 2 SETS 4#3/0 i, 1#20 IN 20 C EACH FIRE ALARM NOTES: 1. FIRE ALARM SYSTEM SHALL COMPLY WITH REQUIREMENTS OF NFPA 101 AND FLORIDA BUILDING CODE 2 FIRE ALARM SYSTEM SHALL BE POWER LIMITED. 3, THE NEW FIRE ALARM SYSTEM SHALL BE CERTIFIED AS A CENTRAL STATION FIRE ALARM SYSTEM 4, SYSTEM SHALL BE PROVIDED WITH SECONDARY POWER SUPPLY OF SUFFICIENT CAPACITY FOR 24 HOURS STANDBY AND 15 MINUTES OF ALARM 5 ALL EQUIPMENT SHALL BE NEW, UL LISTED, COMPATIBLE AND LISTED FOR USE IN FIRE ALARM & INSTALLATION SHALL COMPLY ALL CODES ADOPTED BY THE LOCAL AHU 7. INSTALLATION SHALL COMPLY WITH THE LATEST EDITION OF NFPA 72 NFPA 101, NFPA 1 AND NFPA 7D. 8 CONDUITS SHALL BE 1/20 MINIMUM WITH A MAXIMUM FILL OF 40%, COMPLY WITH NEC. 9. SYSTEM SHALL BE GROUNDED PER MANUFACTURERS SPECIFICATIONS. 111 MINIMUM WIRE SIZE SHALL BE X16 AWG COPPER UNLESS NOTED OTHERWISE tt CONDUCTORS SHALL HAVE MINIMUM RATING OF 300V AND SHALL BE OF SOLID COPPER OR BUNCH - TINNED STRANDED COPPER CONDUCTORS. 12 ALL DEVICES OR UNITS SHALL BE INSTALLED USING APPROVED MATERIALS AND WIRING PRACTICES IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE NFPA 70 ARTICLE #760 POWER LIMITED SECTION AND ALL APPLICABLE LOCAL WIRING ORDINANCES. 13, ALL OUTDOOR FIRE ALARM DEVICES SHALL BE WEATHERPROOF TYPE. 14 OFF -SITE MONITORING SHALL BE PROVIDED, 16 ALL SMOKE DETECTORS SHALL BE MOUNTED MORE THAN 3' AWAY FROM A/C DIFFUSERS 111 INTERCONNECTED FIRE ALARM CONTROL PANEL, REMOTE POWER SUPPLIES, AMPLIFIERS AND DEVICES SHALL BE ARRANGED TO FUNCTION AS A SINGLE SYSTEM AND MONITORED FOR INTEGRITY PER NFPA 72 17. VISUAL NOTIFICATION DEVICES SHALL COMPLY WITH THE LATEST EDITION OF ADA GUIDELINES, BE SYNCHRONIZED WHEN REQUIRED, CLEAR XENON TYPE, AND WITH MIN. INTENSITY OF 75 CANDELAS UNLESS NOTED OTHERWISE ON PLANS. 16. AUDIBILITY SHALL BE AT LEAST 15 dB ABOVE THE AVERAGE AMBIENT SOUND OR 5 dB ABOVE THE MAX SOUND LEVEL WHICHEVER IS GREATER IN THE OCCUPABLE AREA 19, AUDIBLE/VISIBLE AND VISIBLE DEVICES SHALL BE PLACED SUCH THAT THE ENTIRE LENS IS NOT LESS THAN 800 ABOVE THE HIGHEST FLOOR LEVEL WITHIN THE SPACE OR 60 BELOW THE CEILING WHICHEVER IS LOWER AS PER LATEST EDITION OF ADA GUIDELINES AND NFPA 72 2Q WALL - MOUNTED AUDIBLE NOTIFICATION APPLIANCES SHALL HAVE THEIR TOPS ABOVE THE FINISHED FLOOR AT HEIGHTS OF NOT LESS THAN 90" AND BELOW THE FINISHED CEILINGS AT HEIGHTS OF NOT LESS THAN 9' AS PER LATEST EDITION OF NFPA 72 2t THE OPERABLE PART OF EACH MANUAL FIRE ALARM BOX SHALL BE AT 480 AFF AND COMPLY WITH ADA 42 AND NFPA 72 2i. 22 REFER TO FLOOR PLANS AND SPECIFICATIONS FOR EQUIPMENT LOCATION, QUANTITY, USE ETC. THE RISER DIAGRAM SHOWN IS OF A GENERAL FORM 23, PROVIDE END OF LINE RESISTORS, INTERFACE MODULES, CONTROL MODULES, AUXILIARY POWER SUPPLIES, MONITOR MODULES, CONTROL RELAYS, ETC. AS REQUIRED FOR A COMPLETE INSTALLATION. 24. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, FIRE ALARM SYSTEM SPECIFICATION SHEETS AND ALL BATTERY CALCULATIONS TO THE BUILDING DEPARTMENT AND THE ENGINEER FOR REVIEW PRIOR TO ACQUIRING THE PERMIT. 25. ELECTRICAL CONTRACTOR SHALL VISIT THE PROJECT SITE AND INCLUDE IN HIS/HER BID PROPOSAL ALL THE WORK RELATED TO THE INSTALLATION OF THE ENTIRE FIRE ALARM SYSTE=M 26. COORDINATE THE INSTALLATION OF ALL FLOW AND TAMPER SWITCH MONITORS WITH THE FIRE PROTECTION CONTRACTOR 27. COORDINATE THE INSTALLATION OF ALL REQUIRED MONITOR AND CONTROL MODULES FOR THE HVAC EQUIPMENT WITH THE MECHANICAL CONTRACTOR REFER TO MECHANICAL DRAWING FOR THE SEQUENCE OF OPERATION. 28. ELECTRICAL CONTRACTOR SHALL PROVIDE TRANSIENT VOLTAGE SURGE SUPPRESSION (7VSS) ON ALL FIRE ALARM CIRCUITS ENTERING AND LEAVING THE FACILITY, INCLUDING, BUT NOT LIMITED TO CIRCUITS INTERFACING WITH THE FIRE ALARM RECEIVING STATION (%� COMMUNICATION CIRCUITS). MAIN ELECTRICAL ROOM (GARAGE) NEW 2 SETS 4#3/0 & 1#20 IN 20 C EACH ELECTRICAL RISER DIAGRAM NOT TO SCALE •••• ••• • • •••ii •iU YYV �' Y ` Y y Y•GV4 Y W • • V W Y w Y Y U • Y • F Y F Y V • • YYU yV• If F M,/ EXISTING ro I \, I I MAIN 1 OF 1 EXISTING EXISTING EXISTING EXISTING I I I I F -j F^- r F-1 F^ .7 r EXISTING I 8 I I METER I I I I I g l l '/ I I g l l M/ I I 3P/400 11 120/208 V I I I 13P/200 I I I 13P/200 I I I I J 3 PHASE I I B I L_J LTJ L_J LTJ 400 A L__J L_T._J I G G • • LL w _-- _— L---------- F 1-- •------- - - -L -- o 3P/1200 o0 o U_ EXISTING GUTTER L------------------------ E" - - - - -- W - - - - -J ELECTRICAL RISER DIAGRAM NOT TO SCALE •••• ••• • • •••ii •iU YYV �' Y ` Y y Y•GV4 Y W • • V W Y w Y Y U • Y • F Y F Y V • • YYU yV• W ro M • W y Y F • • U• u } • Y • i Y Y • • W • J Y • • Y W Y • � Y • • F • V • U_ • • yvG y•Y Ywi • G G • • LL w YYVY wYYGG •Y• YV1iw.• V • Y • G � w w. rYUy • Y Y W Y w Y • Y Y YyY YYVYYY V Y•U Y YY•• • Roof Plan - Electrical maqueira gineering consultants SCALE: ]/,I'= 1'-0' M.+.QUEIR^ ENGINEERING CONSULTANTS, INC. 7467 SW 50th Terrace 305.669.55+95 Miami, Florida 33155 cadOmaqueiraxem w w 0 } i 0 LL O w U (n DJ wC6 ic �_ dU FLU 0= ZU W� ON <M 0 z WM w�; =N 00 w� �_ za w>- O -o }U UUj LL0 U ao cn} hm a)w O= ZQ tw 0 T z� _z y w �< vw UV r� Kr' W 4 cnz T� OL ROLANDO MAQUEIRA, RE LLp0 FLORIDA PROFESSIONAL ENGINEER ii RE 55432 "7 \I',.— WU (nz o° 0< 0 N U) ro M E0 v) a) r_j M C: 1 O o 0 V L= o L.n o0 o U_ E" W 0 Ir _0 Qj O V un z� _z y w �< vw UV r� Kr' W 4 cnz T� OL ROLANDO MAQUEIRA, RE LLp0 FLORIDA PROFESSIONAL ENGINEER ii RE 55432 "7 \I',.— WU (nz o° 0< 0 N