1 OR 2 HOUR FIRE RATED
THROUGH PENETRATION FIRESTOP FOR SINGLE NON - METALLIC PIPE
THROUGH GYPSUM WALLS USING 3M FIRESTOPPING.
THE 1 OR 2 HR. FIRE RATED GYPSUM BOARD /STUD WALL ASSEMBLY SHALL BE CONSTRUCTED
OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR V400
SERIES WALL OR PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL
INCLUDE THE FOLLOWING CONSTRUCTION FEATURES:
A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL
STUDS. WOOD STUDS TO CONSIST OF NOM. 2 IN. X 4 IN, LUMBER SPACED AT 16 IN,
O.C. MAX. WITH NOM. 2 IN, X4 IN. LUMBER END PLATES AND CROSS BRACES. STEEL
CHANNEL STUDS TO BE NOM. 35 /a IN, WIDE BY 13/0 IN, DEEP CHANNELS SPACED AT 24
IN. O.C. MAX.
B. GYPSUM BOARD - 5/a IN. THICK, 4 FT. WIDE WITH TAPERED EDGES. THE GYPSUM
BOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION
SHALL BE AS SPECIFIED IN THE INDIVIDUAK U300 OR V400 SERIES DESIGN IN THE UL
FIRE RESISTANCE DIRECTORY. MAX DIAM, OF OPENING IS 3)/8 IN.
THROUGH PENETRANTS
O ONE NON- METALLIC PIPE OR CONDUIT TO BE CENTERED IN THE THROUGH OPENING.
THE ANNUAAR SPACE BETWEEN PIPE OR CONDUIT AND PERIPHERY OF OPENING SHALL
BE A MIN, OF Y4 IN. AND MAX 3/a IN. PIPE OR CONDUIT TO BE RIGIDLY SUPPORTED ON
BOTH SIDES OF THE FLOOR- CEILING ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF
NON - METALLIC PIPES OR CONDUITS MAY BE USED:
A. PVC PIPE - NOM. 2 IN. DIAM. (OR SMALLER) SCH. 40 SOLID CORE PVC PIPE USED IN
CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE, OR VENT) PIPING SYSTEM.
B. RIGID NON - METALLIC CONDUIT - NOM. 2" DIAM. (OR SMALLER) SCH. 40 OR 80 PVC
CONDUIT INSTALLED IN ACCORDANCE WITH THE ARTICLE 347 OF THE NEC (NF--PA NO.
70).
C. CPVC PIPE - NOM. 2 IN. DIAM. (OR SMALLER) SDR13.5 CPVC PIPE FOR USE IN
CLOSED (PROCESS OR SUPPLY) PIPING SYSTEM.
D. ccPVC PIPE - NOM. 2 IN. DIAM. (OR SMALLER) SCH 40 CELLULAR CORE PVC PIPE FOR
USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE, OR VENT) PIPING
SYSTEM.
E. ABS PIPE - NOM. 2 IN. DIAM. (OR SMALLER) SCH 40 SOLID CORE ABS PIPE FOR USE
IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE, OR VENT) PIPING
SYSTEM.
F. ccABS PIPE - NOM. 2 in. DIAM. (OR SMALLER) SCH 40 CELLULAR CORE ABS PIPE FOR
USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE, OR VENT) PIPING
SYSTEM.
FIRESTOP SYSTEM
RINSTALLED SYMETRICALLY ON BOTH SIDES OF WALL ASSMERLY. THE HOURLY F AND T
RATINGS FOR FIRESTOP SYSTEM ARE EQUAL TO THE HOURLY FIRE RATING OF THE WALL
ASSEMBLY IN WHICH IT IS INSTALLED, THE DETAILS OF THE FIRESTOP SYSTEM SHALL BE AS
FOLLOWS.
A. FILL, VOID OR CAVITY MATERIALS - WRAP STRIP - NOM. Y4 IN. THICK INTUMESCENT
ELASTOMERIC MATERIAL. FACED ON ONE SIDE WITH ALUMINUM FOIL, SUPPLIED IN 2 IN.
WIDE STRIPS. NOM. 2 IN. WIDE STRIP TIGHTLY WRAPPED AROUND NON- METALLIC PIPE
(FOIL SIDE OUT) WITH SEAM BUTTED. WRAP STRIP LAYER SECURELY BOUND WITH STEEL
WIRE OR ALUMINUM FOIL TAPE AND SLID INTO ANNULAR SPACE APPROX. 1Y4 IN, SUCH
THAT APPROX. 3/4 IN, OF WRAP STRIP PROTRUDES FROM THE WALL SURFACE.
B. FILL, VOID OR CAVITY MATERIALS - CAULK, SEALANT, OR PUTTY - MIN. 5/m IN,
THICKNESS OF CAULK OR PUTTY APPLIED INTO ANNULAR SPACE BETWEEN WRAP STRIP
AND PERIPHERY OF OPENING, A NOM Y4 IN, DIAM. BEAD OF CAULK OR PUTTY TO BE
APPLIED TO THE WRAP STRIP /WALL INTERFACE AND TO THE EXPOSED EDGE OF THE
WRAP STRIP LAYERS APPROX. 3/4 IN. FROM THE WALL SURFACE.
3M COMPANY CP 25WB +, IC 15WB +, FIREDAM 150+ CAULK, FB -3000 WT
SEALANT, OR MP+ STIX PUTTY. (NOTE: L RATINGS APPLY ONLY WHEN CP
25WB-+- CAULK IS USED. CP 25WB+ NOT SUITABLE FOR USE WITH CPVC
PIPES.)
C. FOIL TAPE (NOT SHOWN) - NOM. 4 IN. WIDE, 3 MIL. THICK ALUMINUM TAPE WRAPPED
AROUND PIPE PRIOR TO THE INSTALLATION OF THE WRAP STRIP (ITEM 3A). MIN. OF ONE
WRAP, FLUSH WITH BOTH SIDES OF WALL AND PROCEEDING OUTWARD, TAPE IS NOT
REQUIRED FOR PIPES SHOWN IN ITEMS 2A, 2B, AND 2C.
gw(& WL - 2003
Ss f
F- Raking = 1 and 2 Hr
3M Center
St. Paul, MN 55144 T- Rating = 1 and 2 Hr U n
1 -800- 328 -1687 m �L
Drawing not to scale (See Item 3 Above) sYS t G�
• - - . • - 8
1 OR 2 HOUR FIRE RATED
THROUGH PENETRATION FIRESTOP FOR SINGLE METALLIC PIPE
THROUGH GYPSUM WALLS USING TREMSTOP 1A.
R PRE -RATED GYPSUM WALLBOARD/STUD WALL ASSEMBL=Y
O METALLIC PIPE -
A) STEEL PIPE - 12" DIAM. (OR SMALLER) SCH. 10 (OR HEAVIER)
B) IRON PIPE - 12" DIAM. (OR SMALLER) CAST OR DUCTILE IRON PIPE.
2 COPPER TUBING - 4" DIAM. (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING.
D) COPPER PIPE - 4" DIAM. (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE.
THE ANNULAR SPACE SHALL BE MIN. 0" TO MAX. I" WITHIN THE FIRESTOP SYSTEM.
2 TREMSTOP IA - MIN. 1/2" THICKNESS OF SEALANT APPLIED WITHIN OPENING.
MIN. 114" CANT BEAD OF SEALANT TO BE APPLIED AT POINT CONTACT.
W L -115!
vlviguf@,�) F- Rating = 1 and 2 Hour 2
3735 Green Rd. T- Rating = 1 /,I Hour
Beachwood, OH, 44122 /
Drawing not to scale sy s t co /
kypical JfJ Le penekration signage
FIRE AND SMOKE`1\
BARRUER, PROTECT
A2
ALL
GENERAL NOTE: (F.F.P.C. SECTION 8.3.2.4)
(F.B.C. SECTION 7126)
1. EACH NEW /EXISTING FIRE WALL, FIRE BARRIER, FIRE PARTITION, SMOKE BARRIER, SMOKE
PARTITION, OR ANY NEW /EXISTING WALL REQUIRED TO HAVE PROTECTED OPENINGS SHALL BE
EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING ABOVE ANY
DECORATIVE CEILING AND IN ALL CONCEALED SPACES WITH THE WORDING "FIRE AND SMOKE
BARRIER - PROTECT ALL OPENINGS" OR SIMILAR LANGUAGE. SUCH SIGNS OR STENCILING
SHALL BE PROVIDED WITH 4" IN. HIGH LETTERS, AND 1/2" IN. STROKE, AND NOT MORE
THAN 15' FEET ON- CENTER. SUCH SIGNS OR STENCILING SHALL BE PROVIDED WITH RED
LETTERING AND PROVIDED ON BOTH SIDES OF SAID ASSEMBLIES.
woo
1, APPLICABLE CODES :
(F. B. C.) FLORIDA BUILDING CODE 2010 - WITH LATEST SUPPLEMENTS
(F. B. C. E.) FLORIDA BUILDING CODE 2010 EXISTING - WITH LATEST SUPPLEMENTS
(F.F.P.C.) FLORIDA FIRE PREVENTION CODE 2010 - WITH LATEST SUPPLEMENTS
(N.F.P.A.) LIFE SAFETY CODE HANDBOOK - LATEST EDITION
(F.A.C.) FLORIDA ACCESSIBILITY CODE FOR BLDG. CONSTRUCTION
(N. F. P.A. -10) STANDARD FOR PORTABLE FIRE EXTINGUISHERS
2. CLASSIFICATION OF WORK ALTERATION LEVEL_ ANALYSIS
ALTERATION LEVEL 2 : (F.B.C.E. SECTION 404.1)
SCOPE - LEVEL 2 ALTERATIONS INCLUDE THE RECONFIGURATION OF SPACE, THE ADDITION
OR ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENSION OF
ANY SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT.
MODIFICATION : (F.F.P.0 43.1 , 43.2.2,1_3)
THE RECONFIGURATION OF ANY SPACE THE ADDITION, RELOCATION, OR ELIMINATION OF
ANY DOOR OR WINDOW THE ADDITION OF LOAD BEARING ELEMENTS ,THE RECONFIGURATIO
OR EXTENSION OF ANY SYSTEM OR THE INSTALLATION OF ADDITIONAL EQUIPMENT. 1
3. CATEGORY OF REHABILITATION : (F.F.P.0 NEPA 101, 43.2.2.1.4)
RECONSTRUCTION : THE RECONFIGURATION OF A SPACE THAT AFFECTS AN EXIT OR A
CORRIDOR SHARED BY MORE THAN ONE OCCUPANT SPACE; OR THE RECONFIGURATION OF A
SPACE SUCH THAT THE REHABILITATION WORK AREA IS NOT PERMITTED TO BE OCCUPIED
BECAUSE EXISTING MEANS OF EGRESS AND FIRE PROTECTION SYSTEMS, OR THEIR
EQUIVALENT, ARE NOT IN PLACE OR CONTINUOUSLY MAINTAINED.
4. OCCUPANCY CLASSIFICATION (F.B.C. SECTION 303, F.F.P.C. CH. 12 - NEW ASSEMBLY)
GROUP A2 - ASSEMBLY
5. REQUIRED SEPARATION OF OCCUPANCIES_ (F.B.C. TABLE 508.3.3, F.F.P.0 TABLE 6.1.14.4.1 (b)
GROUP A -2 - ASSEMBLY
WITH GROUP A (ASSEMBLY) = 1 HOUR (SPRINKLERED)
WITH GROUP B (BUSINESS) = 1 HOUR (SPRINKLERED)
WITH GROUP M (MERCANTILE) = 1 HOUR (SPRINKLERED)
6. APPROVED AUTOMATIC SPRINKLER SYSTEM : (F.F.P.C. SECTION 9.7.1)
PROVIDED - EXISTING TO BE ADAPTED TO NEW LAYOUT
7. FIRE ALARM SYSTEM : (F.F.P.C. SECTION 12.3.4)
NOT REQUIRED FOR ASSEMBLY OCCUPANCY WITH LESS THAN 300 OCCUPANTS
8. OCCUPANT LOAD : (F.B.C. TABLE 1004.1 .1 , F.F.P.C. TABLE 7.3.1.2 do CH. 1 2-.1 .7.1 .1)
GROUP A2 - ASSEMBLY
NON FIXED SEATS TABLE/ CHAIRS
INDOOR 845 SF /15 SF. NET PER OCC. = 57 OCC.
OUTDOOR 189 SF /15 SF. NET PER OCC = 18 OCC.
FIXED SEATS :
BANQUETTES 268" L.I. /18" GROSS PER OCC. = 15 OCC.
BOOTH (N /A)
STORAGE (COOLER) 102 SF / 300 GROSS PER OCC. = 1 OCC.
STORAGE 80 SF / 300 GROSS PER OCC. = 1 OCC.
KITCHEN /ORDER COUNTER 738 SF / 100 GROSS PER OCC. = 4 OCC.
OFFICE 42 SF / 100 GROSS PER OCC. = 1 OCC.
TOTAL NUMBER OF OCCUPANTS = 97 OCC.
9. EXIT AND EXIT ACCESS DOORWAYS : (F.B.C. SECTION 1015, F.F.P.C. SECTION 7.4 do 12.2.4)
GROUP A -2
TENANT SPACE EXITS REQUIRED = 2 EXIT
TENANT SPACE EXITS PROVIDED = 2 EXIT
10, EGRESS WIDTH PER OCCUPANT REQUIRED : (F.B.C. TABLE 1 005.1 , F.F.P.C. SECTION 7.2.1.2)
GROUP A -2 = 0.2 /OCC.
TENANT SPACE = 97 TOTAL OCC. (X) 0.2 /OCC. = 20 INCHES REQUIRED
2 DOOR PROVIDED = 10 INCHES EACH
2 DOORS AT 34 INCHES EACH = 68 INCHES PROVIDED
= 68 TOTAL INCHES PROVIDED
11. COMMON PATH OF EGRESS TRAVEL ALLOWED : (F.B.C. SECTION 1014.3, EXCEPTION 5)
(F.F.P.C. SECTION 12.2.5.1.2)
GROUP A -2 = 20 FEET ALLOWED
12. MINIMUM AISLE EGRESS WIDTH ALLOWED : (F.B.C. SECTION 1014.4, F.F.P.C. SECTION 122.3.8)
GROUP A = 44" INCHES
13. EGRESS ACCESS TRAVEL DISTANCE ALLOWED : (F.B.C. TABLE 101 6.1 , F.F.P.C. SECT, 122.6)
GROUP A -2
WITH APPROVED AUTOMATIC SPRINKLER SYSTEM = 250 FEET ALLOWED
14. MINIMUM INTERIOR FINISH FLAME SPREAD do SMOKE DEVELOPMENT CLASSIFICATION
REQUIREMENT: (F.B.C. TABLE 803.5, 804.4.1, F.F.P.C. SECTION 12.3.3)
GROUP A -2 --- WITH APPROVED AUTOMATIC SPRINKLER SYSTEM
WALLS do CEILINGS FINISH :
VERTICAL EXITS AND EXIT PASSAGEWAYS = CLASS "B"
EXIT ACCESS CORRIDORS AND OTHER EXIT WAYS - CLASS "B"
ROOMS AND ENCLOSED SPACES - CLASS "C"
FLOORS FINISH :
EXIT ENCLOSURES = CLASS "II"
EXIT PASSAGEWAYS = CLASS "II"
CORRIDORS CLASS "II"
15. CLASSIFICATION OF HAZARD : (N.F.P.A. 10 SECTION 1 -5)
ORDINARY (MODERATE) HAZARD
(N.F.P.A. 10 SECTION 1-5.2)
MINIMUM RATED SINGLE EXTINGUISHER = 2A
MAXIMUM FLOOR AREA PER UNIT OF A = 1500 SE
MAXIMUM FLOOR AREA FOR EXTINGUISHER = 11,250 SF
MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER = 75 FEET
16, FIRE EXTINGUISHER SPECIFICATION
MANUFACTURER LARSENS
SERIES : MP- SERIES /MULTI PURPOSE DRY CHEMICAL
MODEL NO MP5 (UL RATING 2A- 10B:C)
BRACKET PROVIDE STANDARD BRACKET
OPTION (#1521)
"K" GLASS EXTINGUISHER WITH SIGNS SHALL BE MOUNTED NEXT TO THE HOOD PULL
STATION.
F////
CI
ri
;7• 1.1 , 1 • r
•
1 r�1
TENANT
DEMIZING PARTITION.
�)
�t Nalk'a
MaLMS
S1 K
ro
s -
Irrrrrrr_� . �.• • R.
•
PIZA
lio��el�I PREP COUNTER
M~
X ELECTRIC,L
ROOM
- ---- ---- ----....
r
• li
a
/POI NT ❑
OI DII N)
II
M NAG R'S
OFFIC
(E)
• 2 R RAISED
I � LOUNGE
II
�(E)
I
I
I
R. I
i
•(E)
I I
r � it
L-1 1�1 L-1
T 97 OCC.
OCCUPANT LOAD
I I
r6- i
I I
I I
L - J
EXIT SIGN W/ BATTERY BACK -UP, TYP.
_ I MAXIMUM DIFFERENCE IN FLOOR ELEVATION ON BOTH SIDES OF ALL F2ESS DOORS
TO REMAIN AT 112 MAX. IN ACCORDANCE WITH THE CODE (F.B.C. SECTION
Life Safety Plan 11 -4.3.8 & 11 -4.5.2
SAL E_ 3/1 � =1'
eop 110 1 0"
F.B.G. PLUMBING CHAPTER 4 TABLE 403.1. CLASSIFICATION A -2 NIGHTCLUBS, BARS, TAVERNS, DANCE HALLS AND BUILDINGS FOR
SIMILAR PURPOSES (INCLUDES OUTDOOR SEATING OCCUPANTS)
TOTAL NUMBER OF OCCUPANTS = 97 OCC. (49 MALE / 49 FEMALE)
WATER CLOSET LAVATORIES DRINKING FOUNTAIN
(1/500) SERVICE SINK
MALE (1/75) FEMALE (1/75) MALE (1/200) FEMALE (1/200)
REQUIRED 49/75 = 0.66 49/75 = 0.66 49/200 = 0.25 49/200 0.25 97/500 = 0.195 1
PROVIDED 1 1 1 1 WATER SERVED AT TABLE (a) 1
a. F.B.C. PLUMBING SECTION 410.1 WHERE WATER IS SERVED IN RESTAURANTS, DRINKING FOUNTAINS SHALL NOT BE REQUIRED.
b. F.B.C. PLUMBING SECTION 419.2 URINALS : SUBSTITUTION FOR WATER CLOSETS. IN EACH BATHROOM OR TOILET ROOM, URINALS
SHALL NOT BE SUBSTITUTED FOR MORE THAN 67 PERCENT OF THE REQUIRED WATER CLOSETS IN ASSEMBLY AND EDUCATIONAL
OCCUPANCIES. URINALS SHALL NOT BE SUBSTITUTED FOR MORE THAN 50 PERCENT OF THE REQUIRED WATER CLOSETS IN ALL
OTHER OCCUPANCIES.
c. F.B.C. PLUMBING SECTION 403.1.1 POTTY PARITY : IN ASSEMBLY OCCUPANCIES, RESTROOMS WHICH ARE OPEN TO THE PUBLIC
MUST HAVE A RATIO OF 3:2 WATER CLOSETS PROVIDED FOR WOMEN AS THE COMBINED TOTAL OF WATER CLOSETS AND URINALS
PROVIDED FOR MEN, UNLESS THESE ARE TWO OR FEWER SUCH FIXTURES FOR MEN, IN ACCORDANCE WITH §553.86, FLORIDA
STATUTES.
c.1. EXCEPTION: THIS SECTION DOES NOT APPLY TO ESTABLISHMENTS LICENSED UNDER CHAPTER 509, FLORIDA STATUTES, IF
THE ESTABLISHMENT DOES NOT PROVIDE MEETING OR BANQUET ROOMS WHICH ACCOMMODATE MORE THAN 150 PEOPLE,
AND THE ESTABLISHMENT HAS AT LEAST THE SAME NUMBER OF WATER CLOSETS FOR WOMEN AS THE COMBINED TOTAL
OF WATER CLOSETS AND URINALS FOR MEN.
Iv
Iv cl i
I
w
I I
II
o
IN T it
2
ORDER/PREP.
COUNTE
}
W
r
(i
r,
O
0 = nl
"I
• ru V u •
I �
I
I
o
�
II
II
ww
LJ
w
N
\ ��
ED
p i•G
ID
: `
• i V
••
LL
I
••
V
0>_
7(E)
I
I I
4�
•ice u•� •
F_ -I
/
\
JII
`
L _J
� P.O.. /
zo
I •
THAT READS "THIS DOOR TO
I r
REMAIN OPEN WHEN THE PREMISES
4� (E) (E)
�Gr
t.T
0
o`y
J
J
5�
Gr
o`�tJ�
/POI NT ❑
OI DII N)
II
M NAG R'S
OFFIC
(E)
• 2 R RAISED
I � LOUNGE
II
�(E)
I
I
I
R. I
i
•(E)
I I
r � it
L-1 1�1 L-1
T 97 OCC.
OCCUPANT LOAD
I I
r6- i
I I
I I
L - J
EXIT SIGN W/ BATTERY BACK -UP, TYP.
_ I MAXIMUM DIFFERENCE IN FLOOR ELEVATION ON BOTH SIDES OF ALL F2ESS DOORS
TO REMAIN AT 112 MAX. IN ACCORDANCE WITH THE CODE (F.B.C. SECTION
Life Safety Plan 11 -4.3.8 & 11 -4.5.2
SAL E_ 3/1 � =1'
eop 110 1 0"
F.B.G. PLUMBING CHAPTER 4 TABLE 403.1. CLASSIFICATION A -2 NIGHTCLUBS, BARS, TAVERNS, DANCE HALLS AND BUILDINGS FOR
SIMILAR PURPOSES (INCLUDES OUTDOOR SEATING OCCUPANTS)
TOTAL NUMBER OF OCCUPANTS = 97 OCC. (49 MALE / 49 FEMALE)
WATER CLOSET LAVATORIES DRINKING FOUNTAIN
(1/500) SERVICE SINK
MALE (1/75) FEMALE (1/75) MALE (1/200) FEMALE (1/200)
REQUIRED 49/75 = 0.66 49/75 = 0.66 49/200 = 0.25 49/200 0.25 97/500 = 0.195 1
PROVIDED 1 1 1 1 WATER SERVED AT TABLE (a) 1
a. F.B.C. PLUMBING SECTION 410.1 WHERE WATER IS SERVED IN RESTAURANTS, DRINKING FOUNTAINS SHALL NOT BE REQUIRED.
b. F.B.C. PLUMBING SECTION 419.2 URINALS : SUBSTITUTION FOR WATER CLOSETS. IN EACH BATHROOM OR TOILET ROOM, URINALS
SHALL NOT BE SUBSTITUTED FOR MORE THAN 67 PERCENT OF THE REQUIRED WATER CLOSETS IN ASSEMBLY AND EDUCATIONAL
OCCUPANCIES. URINALS SHALL NOT BE SUBSTITUTED FOR MORE THAN 50 PERCENT OF THE REQUIRED WATER CLOSETS IN ALL
OTHER OCCUPANCIES.
c. F.B.C. PLUMBING SECTION 403.1.1 POTTY PARITY : IN ASSEMBLY OCCUPANCIES, RESTROOMS WHICH ARE OPEN TO THE PUBLIC
MUST HAVE A RATIO OF 3:2 WATER CLOSETS PROVIDED FOR WOMEN AS THE COMBINED TOTAL OF WATER CLOSETS AND URINALS
PROVIDED FOR MEN, UNLESS THESE ARE TWO OR FEWER SUCH FIXTURES FOR MEN, IN ACCORDANCE WITH §553.86, FLORIDA
STATUTES.
c.1. EXCEPTION: THIS SECTION DOES NOT APPLY TO ESTABLISHMENTS LICENSED UNDER CHAPTER 509, FLORIDA STATUTES, IF
THE ESTABLISHMENT DOES NOT PROVIDE MEETING OR BANQUET ROOMS WHICH ACCOMMODATE MORE THAN 150 PEOPLE,
AND THE ESTABLISHMENT HAS AT LEAST THE SAME NUMBER OF WATER CLOSETS FOR WOMEN AS THE COMBINED TOTAL
OF WATER CLOSETS AND URINALS FOR MEN.
Iv
is
0
,, r� n(n
Ow
ZL)
U DU
�
°
z�
L LU0
W M
LLJ
o �-y M
Q op 0) 0 M
U 6� �~ 0 L_
Q 50 p o Q 0 O
LU UL _
0-1 LU
Ln Q !-� � �--I _
lA W 3 E
LLJ 0= Q 0 t7 O O
Oct) 1--
01� O N Q o
O U
oaf Z
w
LLJ z W~ Lu
� is W 1,0 CL +1
0 ~z o
L'
O Qi O
Z
crf UJO
I I
O Z)2
° n m�
O N pz
Z0-v)
- ii 00 o
�
0
_ ...... _ ......... ................ ...............
OUu
w
UIJ•
o
u G Uv •yV
V • U
V W•it)G
• V
}
W
Z
(i
r,
V
t, • • � �,
• ru V u •
3
W
00
Ln
o
ww
w
N
\ ��
• ••i •••
p i•G
ID
: `
• i V
••
LL
••
V
0>_
2LL
4�
•ice u•� •
u
OZ
FLORIDA REGISTERED ARCHITECT RAR9325�
`
REMAIN, SIGNAGE TO BE PROVIDED
wU
zo
I •
THAT READS "THIS DOOR TO
REMAIN OPEN WHEN THE PREMISES
00
wZ
0
VO*Q
J
J
WITH (F.F.P.C. SECTION
k<
G
7.2.1.5.4.1.2 & F.B.C. SECTION
p
• •
1008.1.9.3.2.2.2
LU
00
PROVIDE MAXIMUM OCCUPANT
LOAD SIGN BY MAIN ENTRANCE
io
TRAVEL DISTANCE
U
i•
J
• • i•••"U ♦ V•Vi
• Yi•i �
O
2 11 -12 -2013 FIRE DEPARTMENT
T.D. REQ. IS <150= -011
ROVIDE MAXIMU
w o
EXT
RIOR
a °z
CCUPANT LOAD
?
z
�<
IGN BY
OU
Z
w
J
NTRANCE /EXIT
� •
i
OOR
0
x<1
W
EXTERIOR
i
1/2" M -
i
10 REQ
34 PROIDED
IRED
w
EGRESS
CAF?.
U)
-EXIT SIGN W /B......._TTRY
BACK -U F
TYP.
1
0
r�
60" CLE R
a
�
HANDICAF
TURN I
w
AROUND()
0
Z
EXISTING
SPRINKL R
is
0
,, r� n(n
Ow
ZL)
U DU
�
°
z�
L LU0
W M
LLJ
o �-y M
Q op 0) 0 M
U 6� �~ 0 L_
Q 50 p o Q 0 O
LU UL _
0-1 LU
Ln Q !-� � �--I _
lA W 3 E
LLJ 0= Q 0 t7 O O
Oct) 1--
01� O N Q o
O U
oaf Z
w
LLJ z W~ Lu
� is W 1,0 CL +1
0 ~z o
L'
O Qi O
Z
crf UJO
I I
O Z)2
° n m�
O N pz
Z0-v)
- ii 00 o
�
0
_ ...... _ ......... ................ ...............
- -
d
w
t` �.
o
�-<
V)
O
JF
ww
<<�
W
"
Az�
0>_
2LL
ROBERT K. MORISETTE, AIA, NCARI, LEED AR BD +C, CDR
E
LL
STOREFRONT ENTRY /EXIT DOOR TO
OZ
FLORIDA REGISTERED ARCHITECT RAR9325�
`
REMAIN, SIGNAGE TO BE PROVIDED
wU
zo
I •
THAT READS "THIS DOOR TO
REMAIN OPEN WHEN THE PREMISES
00
wZ
IS OCCUPIED" IN ACCORDANCE
WITH (F.F.P.C. SECTION
k<
3:0
7.2.1.5.4.1.2 & F.B.C. SECTION
p
0
1008.1.9.3.2.2.2
LU
00
PROVIDE MAXIMUM OCCUPANT
LOAD SIGN BY MAIN ENTRANCE
io
TRAVEL DISTANCE
oz
AS PER SE
T- 14.2.5.2,
T_ 0
2 11 -12 -2013 FIRE DEPARTMENT
T.D. REQ. IS <150= -011
w o
EXT
RIOR
a °z
?
10/1i/2013 Life Safety Comments
QL
�<
T N
OU
Z
w
J
OtZ n
� •
TZ
Zo
WJ
a
Alt-, �
nRv- ALARM , .. W
1YA'4'ER NA {H EXT._- .._..� Z) 0
. xnr. ►�.IaZ�r�' ''°' w
W
n
O
0
Z
U)
i 1 ?,1`v ODIFICATIONS ONLY
1"
c
(AKY ICS, A E',)MO tRtICAT�� ZY RrQJ1f1R J
°
0
2
U_
O
LIFE SAFETY
PLAN & CODE
ANALYSIS
tproject number
1
[drawing scale
[drawing date
September 1
phase
PERMIT
sheet number
r
it
D
r