Loading...
11-1153-001F� FIRE ALARM SCOPE OF WORK 1. SUPPLY AND INSTALL NEW NOTIFICATION DEVICES AS SHOWN ON FLOOR PLAN AND RISER DIAGRAM. THESE WILL BE INTERCONNECTED TO THE EXISTING BASE BUILDING FCI -E3 FIRE ALARM CONTROL PANEL LOCATED IN THE ELECTRICAL ROOM ON 1ST FLOOR. 2. SCOPE OF WORK AREA IS A FULLY SPRINKLED BUILDING, AND HAS A TOTAL AREA OF: 2,410 SQ. FT. THE EXISTING FIRE ALARM IS AN ADDRESSABLE INTELLIGENT SYSTEM. THE SYSTEM HAS A SLC DEVICE CAPACITY OF 159 SENSORS, AND 159 MODULES, X2 TO 128 SLC LOOPS, FOR A TOTAL OF 396 TO 40,704 POINTS. 3. THE MAXIMUM HEIGHT OF CEILING IS 9' -0" AS SHOWN ON FLOOR PLAN. 4. FOR MAXIMUM LENGTH PER INDICATING CIRCUIT, SEE CIRCUIT CALCULATIONS. TOILET D'IC1 -1 15175ed I �' MASSAGE I I MIAMI -DADS FIRE RESCUE APPROVED FOR SCOPE OF WORK ONLY COMPLETE AS -BUILT FIRE ALARM SYSTEM INSTALLATION DRAWINGS, INCLUDING A COMPLETE SYSTEM RISER, OPERATIONAND MAINTENANCE MANUALS, ANDA WRITTEN SEQUENCE OFOPERATION AS REQUIRED BY NFPA 72 (2002 EDITION) 10.6.1.1 & 10.6.1.3 AND FLORIDA ADMINMTRATIvE CODE 69A- 43.007 SHALL BE PROVIDED UPON R EQUEST. ANY DOCUMENT DEFICIENCY, O: DEFICIENCY INVOLVING THE FUNCTIONALITY OF THE SYSTEM THAT IS OUTSIDE OF THE SCOPE OF WORK IN TENANT SPACE & THROUGIiOUT REMAINDER OF BUILDING SHALL BE COMMUNICATED IN WRITING TO THE BUILDING OWNER'S REPRESENTATIVE, AND REFERRED TO THE NI.D.F.R. CODE COMPLIANCE BUREAU FOR ENFORCEMENT. SUCH DEFICIENCY SHALL NOTAFFECT THE OUTCOME OF THE SCOPE OF WORK FOR'n1E TENANT SPACE FIRE ALARM PERMIT, AS LONG AS, THE DEFICIENCY DOES NOTAFFECTTHE FUNCTIONALITY OF THE FIRE ALARM WIITHN THE TENANT SPACE. S t9�a�U w A '94 4 Nbl'. V,AtVCE D1 C1 -24 L- 1.515A (954)772 -17D0 (954)772 -0500 fax WWWADVFIREONUNE.COM STATE AND U.L. LICENSED EF#WD1026 U.L.# S7195 -1 75cd eoL GNAL ; oE N: °: T. 1C1, 1% Z LU N �°� Q ._. D1 C1 -2 w' ` 15 f 75cd CORRIDOR Dl Cl-23 75cd L ; o art U W i 0N W CL MASSAGE OF ADVANCED FIRE & SECURITY INC. IT IS NOT TO BE USED OR DUPLICATED BY ANYONE WITHOUT THE WRITTEN CONSENT OF ADVANCED FIRE & SECURITY INC. If any document prepared by Advanced Fire & Security Inc. is altered in any manner by owner, its agents or by any third party if construction is not in accordance with unaltered documents prepared by Advanced Fire & Security PEDICURE AREA whole or in part, related to the project and that the owner and its agents indemnify and holds harmless Advanced Fire & Security Inc. for arty and all acts related to the project. N3L1M3 Contractor shall field verify all information contained on these drawings and is responsible for design and installation of the system in accordance with the specifications. To the best of our knowledge the drawings and specifications submitted herewith, comply with existing interpretations and previsions of the _ or Implied is hereby REVISIONS: COMMENTS PER I=RE 1 DEPARTMENT;ADDRESSED BY D.C.S. 0 0/2! 11) 4 ` 4 413 V ° AFSI�P UMBER: 741° 0310 DATE: SCALE: T ILET 1 1 CHECKED BY: D.C.S. E.J.W. 1 OF 2 BREAK ROOM D1 —22 75cd 0. � � 1 C1 -21 5cd �Q D " �E 15175cd' _ I RECEPTION AREA p D1C1 -4 15/750 ...— -DRYING AR €l D1C1 -4A d NICURE AREA PEDICURE AREA TEE WAITING AR p p E 1N3L1MZ w E a I I MIAMI -DADS FIRE RESCUE APPROVED FOR SCOPE OF WORK ONLY COMPLETE AS -BUILT FIRE ALARM SYSTEM INSTALLATION DRAWINGS, INCLUDING A COMPLETE SYSTEM RISER, OPERATIONAND MAINTENANCE MANUALS, ANDA WRITTEN SEQUENCE OFOPERATION AS REQUIRED BY NFPA 72 (2002 EDITION) 10.6.1.1 & 10.6.1.3 AND FLORIDA ADMINMTRATIvE CODE 69A- 43.007 SHALL BE PROVIDED UPON R EQUEST. ANY DOCUMENT DEFICIENCY, O: DEFICIENCY INVOLVING THE FUNCTIONALITY OF THE SYSTEM THAT IS OUTSIDE OF THE SCOPE OF WORK IN TENANT SPACE & THROUGIiOUT REMAINDER OF BUILDING SHALL BE COMMUNICATED IN WRITING TO THE BUILDING OWNER'S REPRESENTATIVE, AND REFERRED TO THE NI.D.F.R. CODE COMPLIANCE BUREAU FOR ENFORCEMENT. SUCH DEFICIENCY SHALL NOTAFFECT THE OUTCOME OF THE SCOPE OF WORK FOR'n1E TENANT SPACE FIRE ALARM PERMIT, AS LONG AS, THE DEFICIENCY DOES NOTAFFECTTHE FUNCTIONALITY OF THE FIRE ALARM WIITHN THE TENANT SPACE. S t9�a�U w A '94 4 Nbl'. V,AtVCE F=1 Et secURITY 2780 GATEWAY DRIVE POMPANO BEACH, FL 33069 (954)772 -17D0 (954)772 -0500 fax WWWADVFIREONUNE.COM STATE AND U.L. LICENSED EF#WD1026 U.L.# S7195 -1 W 1% Z LU Z Q L art U W i 0N W CL THIS DRAWING AND ITS CONTENTS ARE THE PROPERTY OF ADVANCED FIRE & SECURITY INC. IT IS NOT TO BE USED OR DUPLICATED BY ANYONE WITHOUT THE WRITTEN CONSENT OF ADVANCED FIRE & SECURITY INC. If any document prepared by Advanced Fire & Security Inc. is altered in any manner by owner, its agents or by any third party if construction is not in accordance with unaltered documents prepared by Advanced Fire & Security Inc. then it is understood that Advanced Fire and Security Inc, has no liability in whole or in part, related to the project and that the owner and its agents indemnify and holds harmless Advanced Fire & Security Inc. for arty and all acts related to the project. This concept drawing is for information only to potential system arrangement. Contractor shall field verify all information contained on these drawings and is responsible for design and installation of the system in accordance with the specifications. To the best of our knowledge the drawings and specifications submitted herewith, comply with existing interpretations and previsions of the applicable N.F.P.A. codes in effect at the date shown below. No warranty express or Implied is hereby REVISIONS: COMMENTS PER I=RE 1 DEPARTMENT;ADDRESSED BY D.C.S. 0 0/2! 11) 4 ` 4 413 V AFSI�P UMBER: 741° 0310 DATE: SCALE: 10/06/11 AS SHOWN DRAWN BY: CHECKED BY: D.C.S. E.J.W. 1 OF 2 ® ■ 0 O O W a uou i