Loading...
08-1286-002M 0 N m 00 0 0 ,--I l ,-, 0 d� �1-i E, �: Ln -o v U 4- H W of can (D O� M 0) xl -o 0 C) 0 1q_ N m I i � (n Q 0 >M Q) U E -2 A_- a 21 Q) _ H L Vi c O 'L E d E m O U_ U r-) CL fu O E 0� Q) � m v_C�_ iv _0 Ln 0 M .R U O i 2 ro COMPLIANCE NOTE: ALL WIRING TO BE INSTALLED ACCORDING TO N.E.C. AND IN COMPLIANCE WITH N.F.PA. 72 AND LIFE SAFETY CODE 101. AL TES. -..., .,.... ... ". ....�, . GENERAL NO SYSTEM IS A CERTIFICATED / PLACARDED CENTRAL STATION SERVICE PER N.F.PA. 72.82. THE B U I FULLY SPRINKLERED. BUILDING G S Red Road Commons Scope of Work / Sequence of Operation The fire alarm system at Red Road Commons is a networked fire alarm system for buildings A, B, C, D, E & F. Building E shall be the main fire alarm panel with a Digital Alarm Communicator Transmitter (DACT). Each building will have a remote LCD fire alarm annunicator on the 1St floor at the main entry of each building. Buildings A, B and C Building "A" has an E3 Fire alarm panel which shall be networked back to building "E ". This panel will cover building "B" and building "C ". Buildings A, B and C are tied together due to a common corridor, starting on the 2nd floor thru 5th s s e grouped/zoned to ether the 5 floor. Each of the building's devices hall b g g so e event o i can be identified from through programming that in th v nt fan alarm t g p g g which building the alarm is coming from, reporting the alarm or event to the main panel in building "E "; This panel shall transmit a signal to the monitoring company, clearly as to what building is in alarm (A, B or C). Since buildings A, B and C shar e a co mm o n corridor and ha ve exits into o the parking garage, in the event of alarm from A B or C all three g buildings will o into alarm and also the parking will be p gara e g 9 p ut into alarm. Building "D" has an E3 Fire alarm panel which shall be networked back to building "E ". In the event of an alarm in building "D ", only building "D" shall go it will report it to building E and transmit a signal to the onto alarm and p g g monitoring clear) as to building "D" is in alarm. 9 Y g Buildin 9 E Buildin g E has an E3 F ire alarm panel which shall be th e main fire alarm panel, panel s P g this p I hall be networked with the panels in buildings A D and F. In the event of an alarm in building "E ", only building "E" shall go onto alarm and transmit a signal to the monitoring company, clearly as to building "E" is in alarm. Building F Building "F" has an E3 Fire alarm panel which shall be networked back to building "E ". In the event of an alarm in building "F ", only building "F" shall go onto alarm and it will report it to building "E ", and transmit a signal to the monitoring company, clearly as to building "F" is in alarm. Building G Building "G" (parking garage) is a separate fire alarm system not being installed by Power Design (PDI). PDI shall monitor the fire alarm panel in the parking garage for an alarm, trouble and supervisory signals which shall be monitor be the panel in building "E ". In the event of an alarm in building "G'; Building A, B and C will go into alarm, and the panel in building "E" shall transmit a signal to the monitoring company reporting an alarm in building "G" parking garage. WIRE LEGEND: (NOT ALL WIRE TYPES ARE USED ON THIS PROJECT) FOLLOWING: TYPE ? DESCRIPTION ` SIZE NO. OF CONDUCTORS COMMON TROUBLE LIGHT SHALL ILLUMINATE AT REMOTE COLOR NOTES 'A' INITIATING CIRCUIT 18 AWG 2 CONDUCTOR, FPLR ? RED `:. CAT. NO. IR182PFPL -02/04 (ISOTEC) . ...... ..... ................. . ........ 'C' .. ... ........... ... ........... .. ............ . ....................... ......... .............. ...... ....... ... .............. ..... 1 .... 11 INDICATING CIRCUIT . ..... 1........,. 14 AWG .... ..................... ... .............. ......... ....................................... ... ............. 2 CONDUCTOR, FPLR ''•. ... .............. ........... ........... .......:. BLACK CAT. NO. I R142PFPL -00/04 (I SOTEC) ... -. -- - .... .. 'D' .... ............... ................_... _ _............. _ ..........11_...._ . ICP TRIP CIRCUIT ......................................... 18 AWG ._._............._............_................... ....._.........._._...........- ..........._......_....,....._.........._.. 2 CONDUCTOR, FPLR i ..__._................_........ BLUE _ ...._ . ..... ........ . CAT. NO. IR182PFPL -02/04 (ISOTEC) ................ .............................._ 'E' ,... ...._.........-....._...... ........._.__.._..._...__..._._ .. ._.__.._._ ELEVATOR WARNING LIGHT ........_ .........11..11.............. ; 18 AWG _ _ _ . _ 1111...................... ...........11.11.. 1111.._._ 2 CONDUCTOR, FPLR _. _,...... ........__. WHITE _ .. _ 1 ..111. _____. ...... ... ........... ..... ... ._............ CAT. NO. IR182PFPL -02/04 (ISOTEC) 5. CIRCUIT 6. LOW OR NO BATTERY VOLTAGE CONDITION. 7. MAIN SPRINKLER VALVE IS CLOSED. 8. 'M' DOOR HOLD OPENERS _1111_ _ ..._ _. . 18 AWG •. .......... _.._..... ... _......... 2 CONDUCTOR, FPLR Z I z GREEN ......................... .......... ....... .. ............ CAT. NO. IR182PFPL -02/04 (ISOTEC) 1111 ........_._ 'P' . _ _._ ................. ..................._.........._ _.._......._ __.........._... ANNUNCIATOR POWER ... _ 1111 _ _.._.... _ ........ s 18 AWG 1111 2 CONDUCTOR, FPLR :._1111 i ............... ... _ .... BLACK CAT. NO. IR182PFPL -02/04 (ISOTEC) 'R' :............_ ...........................................................................................................,........................................................................................................................................................................... RESETABLE SMOKE DETECTOR i 18 AWG 2 CONDUCTOR, FPLR DISPLAY PANEL SECTION SHALL CONSTANTLY MONITOR ............................... GREEN ............................................................. ..............................1 ..................... ,­ 11... . CAT. NO. IR182PFPL -02/04 (ISOTEC) WITH UNIT POWER " ,: ; 1111 ._ ....._ ............................,........................................ FCI WHEN TROUBLE IS REMOVED, 2. DISPLAY 1.1111111.1­ .. _..... z 1..._...., 1111 ....... .............:................. ....... ........1..111 , ,... .. .. ,. _ " .. _., _ _. ..11 1 ..1. . :1111.. ::.,.. ,.... :X.. 'S' SIGNAL LINE CIRCUIT ': 14 AWG ,, 2 CONDUCTOR, TWISTED ELEVATOR LOBBY SMOKE DETECTOR (BY ELEVATOR AND RED CAT. NO. IR14/2FPL1 -02 (ISOTEC) ' e. (BUILDING INTERIORS) ' `• UNSHIELDED PAIR, FPLR f. ACTIVATED SIGNAL HRORNS (BY FLOOR). ............................... .. . ADDRESSABLE PHOTO SMOKE DETECTOR ........_ ........................ ....... .._.......,...___.............................----._.._.......- __....._..._...._......_.____._ 1111. 111.1_ ...11.11 111.11111.. 11 _____ _ (OPEN - CLOSED BY DAMPER). I. 1111_. _1111... T I I 18 AWG z ANNUNCIATOR COMMUN CAT ONS 2 CONDUCTOR, TWISTED OPERATING MODE (TESFFT- NORMAL). RED CAT. NO. LVW18 2 FPLR -S METRO / (METRO) r H. ' LINE AND RETURN t SHIELDED PAIR, FPLR I FCI FLOW SWITCH ONLY. , ... 4'SQ, 2 -1/8' DEEP MIN. ...........� ............. ou 1 -111...... ............................... ..................... ... 11...11 _ ' SIGNAL LINE CIRCUIT . . ' 14 AWG 1 2 CONDUCTOR, T.SP. 3. FLOW BELL SHALL NOT BE SILENCABLE BY THE BLACK __ C ....A.....T... AT. NO. 1142SVNTC (ISOTEC) \....: . . -�..._ ..: � ... .... .... ... ..... .. _ -\.._ - �_.. ­.,..,\,_,, ._ \.._ ....__. 1_, (UG DIRECT BURIAL RATED) z z . (FPLR / PLTC) ...... ................. .. 1111... 4' SO, 2 -1/8' DEEP MIN. .111 .............. ..... ....... ......... COVER FURNISHED WITH UNIT ® ..._._.......____......._..__. 'X' .................................................................................................................................... AUXILIARY POWER, 24V DC z z 18 AWG ........................._.._.. 2 CONDUCTOR, FPLR : CONFIGURED AS FORM `C' RELAY _........_..._......_.. BLACK _.._ _ _.._............._........._... 1_.1....11..............- ..._.. ..1_........111.__. CAT. NO. IR182PFPL -02/04 (ISOTEC) WIRE NOTES: 1. ALL WIRING INSTALLATION SHALL BE IN COMPLIANCE WITH N.F.P.A. 72, LIFE SAFETY CODE 101 AND NE.C. Z ALL PAIRED CABLE SHALL BE CONNECTED AS: SOLID COLOR WIRE (A POSITIVE, STRIPED (IDENTIFIED), CONDUCTOR ( -) NEGATIVE. 3. ALL TWISTED PAIR CABLES SHALL BE CONNECTED AS: COLORED WIRE IE (RED, WHITE, ETC) (A POSITIVE, BLACK OR IDENTIFIED CONDUCTOR ( -) NEGATIVE. 4. CONNECTIONS AT DEVICES SHALL BE AS INDICATED ON INSTALLATION DOCUMENTS AND AS FURNISHED WITH EQUIPMENT AND / OR DEVICES. I FIRE ALARM SEQUENCE OF OPERATION: I EACH BUILDING SHALL ACT INDEPENDENT FROM ONE ANOTHER. THE FOLLOWING SHALL OCCUR UPON A GENERAL ALARM CONDITION IN EACH BUILDING. A. ACTIVATION OF ANY INITIATING DEVICE SHALL CAUSE THE FOLLOWING: 1. AUTOMATICALLY TRANSMIT FIRE ALARM SIGNAL TO FIRE DEPARTMENT VIA LEASED TELEPHONE LINE TO APPROVED CENTRAL OFFICE. 2. SOUND FIRE ALARM SIGNAL AND DISPLAY ZONE AND ALARM MESSAGE AT FIRE COMMAND STATION (FCS). ALARM LIGHT AND TROUBLE SIGNAL OPERATE UNTIL ALARM CONDITION IS CORRECTED AND CPU IS' MANUALLY RESET. 3. ACTIVATE AUDIOVISUAL SIGNALS ON ALL FLOOR. 4. ACTUATE STATION IDENTIFICATION ON DISPLAY PANEL AT THE BUILDING FIRE ALARM PANEL & REMOTE ANNUNICATOR. 5. DROP ALL POWER TO DOOR HOLD OPEN DEVICES. 6. DROP ALL POWER TO ACCESS CONTROLLED DOORS. B. ALL FIRE ALARM SIGNALS ARE AUTOMATICALLY LOCKED IN AT CPU AND REMOTE ANNUNCIATORS UNTIL ORIGINATING DEVICE IS RETURNED TO NORMAL AND CPU IS MANUALLY RESET. 1. AUDIBLE ALARM SIGNAL , SHALL BE SILENCEABLE FROM CPU ALLOWING FOR RE - INITIATION FOLLOWING A SUBSEQUENT ALARM. SILENCING OF ALARM SIGNALS SHALL NOT IMPAIR THE ABILITY OF SYSTEM TO CONTINUE TO PERFORM AS SPECIFIED. 2. ACTIVATION OF ANY TROUBLE OR SUPERVISORY SIGNAL TRANSMIT SIGNAL ! SHALL TO LISTED CERTIFICATED CENTRAL MONITORING STATION VIA' PHONE LINE. C. ACTIVATION OF SMOKE 0 DETECTORS AT ELEVATOR LOBBIES ELEVATOR SHAFTS AND ELEVATOR MACHINE ROOMS SHALL INITIATE ELEVATOR RECALL SEQUENCE PER ANSI ASME -A17.1 FOR ELEVATORS IN BANK SERVED BY ACTIVATED D CTOR(S). CONTROL RELAYS SHALL BE WIRED TO SEND SIGNALS TO ASSOCIATED MAIN ELEVATOR CONTROLLER INDICATING THAT: 1. AN ALARM INITIATION DEVICE HAS BEEN ACTIVATED ON A FLOOR OTHER THAN FIRST FLOOR. ELEVATOR MANUFACTURER SHALL ',FURNISH LOGIC AT ELEVATOR CONTROLLER(S) TO SEND ELEVATOR(S) TO FIRST FLOOR ON RECEIPT OF THIS SIGNAL OR: 2. AN ALARM IN INITIATION DEVICE HAS BEEN ACTIVATED ON FIRST FLOOR. ELEVATOR MANUFACTURER SHALL FURNISH LOGIC AT ELEVATOR CONTROLLER TO SEND ELEVATOR (S) TO DESIGNATED ALTERNATE FLOOR ON RECEIPT OF THIS SIGNAL. 3. SIGNAL IS SENT TO 'FACP AND TRANSMITTED OFFSITE 4. HEAT DETECTOR IN THE ELEVATOR SHAFT & MACHINE „`RM. WILL ACTIVATE THE SHUNT TRIP BREAKER 5. CONTROL CIRCUITS TO SHUT -DOWN ELEVATOR POWER SHALL BE MONITORED FOR PRESENCE OF OPERATING VOLTAGE. LOSS OF VOLTAGE TO THE CONTROL CIRCUIT FOR THE DISCONNECTING MEANS SHALL CAUSE A SUPERVISORY SIGNAL TO BE INDICATED AT THE CONTROL 2 UNIT AND REQUIRED REMOTE ANNUNCIATORS PER N.F.P.A. 72 6.15.4.4 (2002 EDITION). ....I .. .... D. ACKNOWLEDGING ALARM AT FIRE COMMAND STATION SHALL: 1. SILENCE ALARM, STEADY FLASHING INDICATING LAMP E. ACTIVATION OF ANY SYSTEM TROUBLE SHALL INITIATE THE FOLLOWING: MOUNTED AND LOCATED AS DIRECTED BY 1. COMMON AUDIBLE TROUBLE SIGNAL SHALL SOUND AND (727) 210 -0492 COMMON TROUBLE LIGHT SHALL ILLUMINATE AT REMOTE coo CD E ANNUNCIATORS. 2. COMMON AUDIBLE TROUBLE SIGNAL SHALL SOUND AND BACKBOX COMMON TROUBLE LIGHT SHALL ILLUM I NATE AT FACP SPRINKLER FLOW SWITCH ALSO A SPECIFIC ZONE DISPLAY SHALL 3 PART NUMBER; BE PROVIDED AT FACP TO INDICATE JUNCTION BOX SPECIFIC ZONE DEVICE OR CIRCUIT IN TROUBLE F. AUDIBLE TROUBLE SIGNAL SHALL BE SILENCEABLE BY SWITCH. VISUAL TROUBLE INDICATION REMAINS UNTIL TROUBLE CONDITION IS CORRECTED. A SUBSEQUENT TROUBLE CONDITION RECEIVED AFTER MANUALLY SILENCING SHALL CAUSE SEQUENCE ON ITEM J -2. RESTORATION OF SYSTEM TO NORMAL CAUSES AUDIBLE TROUBLE SIGNAL UNTIL SILENCING SWITCH IS RETURNED TO NORMAL POSITION, TROUBLE SIGNAL WILL BE INITIATED UNDER FOLLOWING CONDITIONS: 1. OPEN ON AN INITIATION OR ALARM INDICATING CIRCUIT. 2. OPEN IN WIRING TO REMOTE ZONE LIGHT ANNUNCIATOR(S). 3. GROUND FAULT CONDITION. 4. AUXILIARY MANUAL CONTROL SWITCH OUT OF NORMAL FURNISHED W/UNIT POSITION. 5. LOSS OF 120 VOLT OPERATING POWER TO CPU. 6. LOW OR NO BATTERY VOLTAGE CONDITION. 7. MAIN SPRINKLER VALVE IS CLOSED. 8. POST INDICATOR VALVE IS CLOSED. 9. ANY SPRINKLER OR STANDPIPE, 0, S & Y VALVE IS CLOSED. 10. FIRE PUMP CONTROLLER HAS OPERATED INTO A MOTOR ...._ -..........._........._...................................................., N/A RUNNING CONDITION. 11. LOSS OF LINE POWER TO ANY PHASE ON LINE SIDE OF FIRE SPRINKLER BELL, 24VDC, PUMP MOTOR STARTER. 12. PHASE REVERSAL ON LINE SIDE OF FIRE PUMP MOTOR 3 STARTER. G. OPERATION OF FIRE COMMAND STATION SHALL BE AS FOLLOWS: 1. DISPLAY PANEL SECTION SHALL CONSTANTLY MONITOR HPF24S8 ALARM INITIATING DEVICES AND UPON ACTIVATION INDICATE WITH UNIT VISIBLE ALARM CONDITION UNTIL MANUALLY RESET, AND .................................................................................................................................__..................................._..._..._- INDICATE TROUBLE CONDITION UNTIL AUTOMATICALLY RESET 1111 ._ ....._ ............................,........................................ FCI WHEN TROUBLE IS REMOVED, 2. DISPLAY FOLLOWING ALARMS AND SYSTEM STATUS IN ORDER OF LISTED PRIORITY: a. MANUAL FIRE ALARM STATION BY DEVICE LOCATION). b. AREA SMOKE AND HEAT DETECTORS (BY DEVICE ;. < LOCATION . C . SPRINKL R WATERFLOW (BY ZONE). d. ELEVATOR LOBBY SMOKE DETECTOR (BY ELEVATOR AND ............................... - FLOOR). e. ELEVA OR AND MACHINE ROOM SMOKE FAD-3 SHAFT SFIREY f. ACTIVATED SIGNAL HRORNS (BY FLOOR). ............................... .. . ADDRESSABLE PHOTO SMOKE DETECTOR FIRE DEPARTMENT NOTIFICATION VIA CENTRAL OFFICE. g. . FIRE SIGNAL TROUBLE FIRE /ALARM DAMPERS i (OPEN - CLOSED BY DAMPER). I. TAMPER SWITCH (BY FLOOR OR ZONE). X (ALARM POWER O t. OPERATING MODE (TESFFT- NORMAL). I. GENERATOR RUNNING .: 1111 ,_.., ...... _ 1111"....,,....., , ."" ... r H. OPERATION OF FLOW BELL. t 1. FLOW BELL SHALL SOUND UPON ACTIVATION OF THE I FCI FLOW SWITCH ONLY. , ... 4'SQ, 2 -1/8' DEEP MIN. 2. FLOW BELL SHALL SOUND THE ENTIRE TIME OF Project No: 03 -COA -7052 WATER FLOW. AMM -2F 3. FLOW BELL SHALL NOT BE SILENCABLE BY THE ,\ FACP. \....: . . -�..._ ..: � ... .... .... ... ..... .. _ -\.._ - �_.. ­.,..,\,_,, ._ \.._ ....__. 1_, SYMBOL LEGEND: (NOT ALL SYMBOLS ARE USED ON THIS PROJECT) BACKBOX MOUNTED AND LOCATED AS DIRECTED BY ADDRESSABLE DEVICES 33716 (727) 210 -0492 0 coo CD E SYMBOL ` DESCRIPTION MANUFACTURhIOUNTING HEIGHT BACKBOX NOTES SPRINKLER FLOW SWITCH BY SPRINKLER 3 PART NUMBER; DOOR HOLDER 3 JUNCTION BOX FLUSH MTD. 1 CONNECT TO ASSOCIATED INITIATING ZONE g FURNISHED BY OTHERS ? CONTRACTOR AL4000L AS REQUIRED FIRE ALARM CONTROL PANEL W/DACT FCI 6' TOP MAX i SURFACE fi� �: , � i ; ADDRESSABLE f IRE .ALARM r' ® REQUIRES DEDICATED LIFE SAFETY CIRCUIT E3 SERIES ... .. ................... . ...... . ............ ... ... ........ ............. . ................... .................................... ........ ... ........... ........... JUNCTION BOX FURNISHED W/UNIT `CONTROL PANEL WITH DA%T FURNISHED BY OTHERS ........-..._ ................................._...................._.... ....._.........._..._....._.___ si _ 11:11___ Co . - 1111 ,... �.._ "..._: �.... ......... 1111_- 1111 _... _ ........... _ -. ......_...._ ® FIRE ALARM ANNUNCIATOR FCI 60' CENTER LINE AFF. FURNISHED WITH UNIT MOUNTED AND LOCATED AS DIRECTED BY Z t ...._ -..........._........._...................................................., N/A ........ 1 LCD -7100 FA.02 SPRINKLER BELL, 24VDC, AN,J. WHERE APPLICABLE ® INDICATING CIRCUIT POWER EXPANDER 3 1111 6' -0' TOP MAX SURFACE, FURNISHED LOCATED AS INDICATED ON VERIFY LOCATION, FURNISHED BY OTHERS POWER SUPPLY HPF24S8 € WITH UNIT SHOP DRAWINGS .................................................................................................................................__..................................._..._..._- _..._.........._..._...,_..... I ADDRESSABLE MANUAL PULL STATION 1111 ._ ....._ ............................,........................................ FCI .............................._ .........„.....................-....-..................-....-......................-..........-.....,,..................................................-.............. 48' CENTER LINE AFF. SINGLE GANG MINIMUM .......... . .... ...... .......... .. ... . 11 . ... ...... . I M01 = DESIGNATES MODULE ADDRESS P:M01 i WITH BUILT IN MODULE I MS -7AF FA.D -1 FA 1st Level Floor Plans Bldg D ;. < _ ........................ ............................... M01 ..........................................._........................................................................... ............................... MANUAL PULL STATION WITH MODULE .........................................................................................._...................................................__..,..............................................................................................................................................................................._............................ ' FCI 48" CENTER LINE AFF. FURNISHED WITH UNIT ............................... - PE] WP WP= WEATHER PROOF MS -7LOB IMM-2F ; FAD-3 FA 3rd Level Floor Plans Bldg D INCLUDES ADDRESSABLE MONITOR MODUL _ .....................................I......._........................ DR E ............................... .. . ADDRESSABLE PHOTO SMOKE DETECTOR FCI ! CEILING UNO. UNIVERSAL MTG. BRACKET i OSMOKE USE FOR ELEV RECALL, STAIR PRESSURE; NASD -PL2F 3 COLOR: RED X 15, 75, OR 110 CANDELLA AS INDICATED A 0R DAMPER CONTROL . ........... .............................._ ...__ ...................... .111111 .11............. ..............................i ................ - - - -. ----- -......... ................. _........_ .11 1........ 1 11 .............._._....._.. --- ............ --- - -.. .-- -.............. .... - -- ..... ............_......._ _._........ 0 1_ '•. ADDRESSABLE MONITOR MODULE I FCI AS REQUIRED ; ... 4'SQ, 2 -1/8' DEEP MIN. COVER FURNISHED WITH UNIT Project No: 03 -COA -7052 . .1..111................................ . .... . COLOR: RED AMM -2F Revisions: &/OR D/G P-RING SURFACE MTD. .............................................................................................................................. ............................... ... .......... ... ....... ... ..... CONTROL RELAY MODULE ............ .... ....... ... FCI ; ..11 1.1...... .1.....1 ... ..... , .. AS REQUIRED '_. ...... ................. .. 1111... 4' SO, 2 -1/8' DEEP MIN. .111 .............. ..... ....... ......... COVER FURNISHED WITH UNIT ® .............................., 80' BOTTOM AFF. OR AOM -2RF WBB &/OR D/G P-RING : CONFIGURED AS FORM `C' RELAY CONVENTIONAL DEVICES SYMBOL DESCRIPTION PART NUMBER MOUNTING HEIGHT BACKBOX MOUNTED AND LOCATED AS DIRECTED BY NOTES 33716 (727) 210 -0492 0 coo CD E I A.H.J. WHERE APPLICABLE �- E 7836 Ashley Circle 3 34201 42i',,,4, 6d .a. .;�•I ° � (727) 497'32 3 K� „ SPRINKLER FLOW SWITCH BY SPRINKLER F.B.O. DOOR HOLDER 3 JUNCTION BOX FLUSH MTD. 1 CONNECT TO ASSOCIATED INITIATING ZONE g FURNISHED BY OTHERS ? CONTRACTOR AL4000L . AS REQUIRED AS REQUIRED AUX POWER FOR DOOR HOLDERS OR MODULE _..._ ......... ....._.._....................._ ,.._..__....._...._........ (� ..__....._........__...._..._._ ....._.._......_.........._...._..._................_....__..._ SPRINKLER TAMPER SWITCH ...,.._.._._............_....__ .......... BY SPRINKLER 1111 ...._._........_ ........._, FB.O. _......._................................................................................................. JUNCTION BOX ... .. ................... . ...... . ............ ... ... ........ ............. . ................... .................................... ........ ... ........... ........... JUNCTION BOX ................_.....__....... _...................................._.............................. ............................... . CONNECT TO ASSOCIATED INITIATING ZONE Y FURNISHED BY OTHERS CONTRACTOR • Co AS REQUIRED I OR MODULE .................:. , ,,, 1111. ,..... ............. . ... ........._...._..........._..._ _.._......_.._.__...__._........._.-...._........;.... END OF LINE RESISTOR ; ........_.._.................._ .. 1111.. ......._....._..._.... N/A - - 1111... 11111111. ON DEVICE ; ...._ -..........._........._...................................................., N/A ........ . ....................... ..... ... .._.... ------------ ___ --- ........_._........................ ................. . ..... . ... .... ........ ........_......._.. FA.02 SPRINKLER BELL, 24VDC, BY SPRINKLER F.B.O. ; OR MODULES FURNISHED WITH - O VERIFY LOCATION, FURNISHED BY OTHERS CONTRACTOR FA.S UNIT W.P. • • ,1111 M C1 -1 ,:......,,... _. 1111 :. ,...:.........:. 1111. APARTMENT HORN `1 ...; ... :: ,111.1 ...:..........:.. -�......_.__... MHW `•'..�2.'`, _._.........__.-._.._. ......._.........._ ............ 80" BOTTOM AFF. O ... ­­11111 _....................._.................. ............................... SINGLE GANG OR. COLOR: WHITE FA.D -1 FA 1st Level Floor Plans Bldg D ;. < • • • FA.D -2 1 -1 = DESIGNATES IND. CKT. AND DEVICE # • • \,...: 1 _, • FAD-3 FA 3rd Level Floor Plans Bldg D • • • STROBE ONLY SR 80' BOTTOM AFF. i SINGLE GANG • COLOR: RED X 15, 75, OR 110 CANDELLA AS INDICATED I • • • • . C1 -1 = DESIGNATES IND. CKT. AND DEVICE # Cl-1 MULTI- CANDELLA HORN WITH STROBE P2R 80' BOTTOM AFF. Drawn By: O.G 4' SQUARE 2 -1/8' DEEP Project No: 03 -COA -7052 . .1..111................................ . .... . COLOR: RED Revisions: I SURFACE MTD. QSept. 22, 2008 ; C1 -1 = DESIGNATES IND. CKT. AND DEVICE # _ . _ ........................... ............................... C1 -1 ? _ .........:...... _.................................................................................. ............................... _................ 75C. HORN WITH STROBE _.......................................................................................................... P2RK .............................., 80' BOTTOM AFF. OR ......................................................................................................................................................... I WBB i ............................... _....... ............ ................ ......... ...... ........._- __...._........._... COLOR RED WP WEATHERPROOF HORN / STROBE Sheet No: AS INDICATED, SURF. MTD. I C1 -1 = DESIGNATES IND. CKT. AND DEVICE # ................................................................................................................................................................................................. ............................... ...... ................._............. 1111. 1111.. ............... ....._.............. ............_.................. [E]WP WP PULL BOX N/A AS INDICATED INTERCONNECTION OF SITE MONITORING ' ' AS INDICATED ION BOX DETAIU LOOP WIRI (SEE WP JUNCTION J❑WP WP JUNCTION BOX ..........................._....................................,..........................................................................--................._....................._..._...................................................................................................._.........................._........_............._............._...._.............._....._.... N/A AS INDICATED i 12'x12'Sc6' OR ............................... FOR INTERCONNECTION OF SITE MONITORING 3 AS INDICATED LOOP WIRING (SEE WP JUNCTION BOX DETAIL) y ; TELEPHONE MODULAR JACK ...1111. i DTK -MRJ45 ; 11.11......... AS REQUIRED ................._ _....................................................................,....................................................................................................... SURFACE MOUNTED ...._..._......___............_ .1.111.. FURNISHED BY OTHERS 3 ..............:............................:........................................................................................................................................................:.........................................................................................................................................................................................................................................................:.................................................................................................................................................. (2 LINES REQUIRED) FOR TELEPHONE DIALER TO CONTROL STATION ............................... K❑ KNOX BOX BY AHJ. ? F.B.O. SELF CONTAINED MOUNTED AND LOCATED AS DIRECTED BY co 0 00 N o 33716 (727) 210 -0492 0 coo CD E I A.H.J. WHERE APPLICABLE �- E 7836 Ashley Circle 3 34201 42i',,,4, 6d .a. .;�•I ° � (727) 497'32 3 K� „ _ ......._ _..__......._.._..____ ......... ............. ...._._.....__... _ .. ---- ......... ® DOOR HOLDER 3 DH-FCi ' FLUSH MTD. 1 SINGLE GANG CHECK DOOR SCHEDULE ® '_. AUXILIARY POWER SUPPLY 1 AL4000L . AS REQUIRED N/A AUX POWER FOR DOOR HOLDERS 1111­11111111 ............................................................................_.............................._.....................................................................................;.................................................................,.....................................................................................,..................................................................................................>......................_..................---.............................................................. Q SURGE SUPPRESSOR DTK- 120 -HW FB.O. ` N/A ............................... :: 120V AC SURGE SUPPRESSOR ..... .... ..... . ... ... ... ............. 0 ... .. ................... . ...... . ............ ... ... ........ ............. . ................... .................................... ........ ... ........... ........... JUNCTION BOX .... . ... ... .... ...... ..... ................. ..._... .... ......... N/A ......... 11 ....................__...................._.................,......................_.._......-..._.....-............................................-....,...... 80' BOTTOM AFF. SINGLE GANG W/SLANK ........- .- .................... _.............................. _....I................._.._.... ...1.......1......1.......1.... ; FOR FUTURE HANDICAP CONVERSION • Co :> 0� PLATE / WHITE .................._............_..............._.. ........._...._..........._..._ _.._......_.._.__...__._........._.-...._........;.... END OF LINE RESISTOR ; ........_.._.................._ .. 1111.. ......._....._..._.... N/A - - 1111... 11111111. ON DEVICE ; ...._ -..........._........._...................................................., N/A ........... ..... ............................................... ..... ................. .. .................... ..........._......._._._.... < FURNISHED WITH CONTROL PANEL "�� O FA.02 Fire Alarm Schedules AS INDICATED • ; OR MODULES Red Road Commons Bldg D POWER DISIGn co SR rn eo 0 T co 0 C'4 N co 0 00 N o 33716 (727) 210 -0492 0 coo CD E rn o E �- E 7836 Ashley Circle University Park Florida Y 34201 42i',,,4, 6d .a. .;�•I ° � (727) 497'32 3 K� „ v U U w . F �­ - " I E ' cr.: " �C . °' n 1^y +r ,pp + y e Y" , " C I Y'° t. $o ,..k y , ,.. In Drawing co Number I Drawing Title Z3 U CU - 1111111111 ::) Z a Cover • 0 • • Co :> 0� a FA.01 Fire Alarm Legend & Symbols • • • • FA.02 Fire Alarm Schedules • • • r*,_ - Li) 1: FA.S Fire Alarm Site Plan • • • 3i _ � O FA.D -1 FA 1st Level Floor Plans Bldg D • • • • FA.D -2 FA 2nd Level Floor Plans Bldg D • • • • FAD-3 FA 3rd Level Floor Plans Bldg D • • • • FA.D -4 FA 4th Level Floor Plans Bldg D • • • • FA.D -5 Bldg D Riser Diagram I • • • • . - I +__ SHEET NUMBER SYSTEM DISCIPUN F FLOOR OF BUILDING FA -01 LEGEND FA 1 FA1-X BLDG. TYPE 1 PLANS FAUX BLDG. TYPE 2 PLANS FA-CH CLUBHOUSE PLAN FA1 -1B BUILDING NO, AREA OF BUILDING 1 B 4 POWER DISIGn INCORPORATED Power Design, Inc. 11600 Ninth Street North St. Petersburg, Florida 33716 (727) 210 -0492 (727) 210 -0503 (Fax) E.C. #0000481 Engineer Seal: William R. Bates 7836 Ashley Circle University Park Florida Y 34201 42i',,,4, 6d .a. .;�•I ° � (727) 497'32 3 K� „ �i"�. _ #6481 "I t� w . F �­ - " I E ' cr.: " �C . i'' 1^y +r ,pp + y e Y" , " C I Y'° t. $o ,..k y , ,.. In co ■C W - 1111111111 ::) Z a W Co :> 0� a O vi 2 _I LL. F_ O r*,_ - Li) 1: E Q E 3i _ � O V F-- 'a O O M -,0 w O .o 12 13 O 19 Drawn By: O.G Checked By: L.R. Project No: 03 -COA -7052 Date: May 19, 2008 Revisions: QAugust 12, 2008 Plan Review Corn. QSept. 22, 2008 Plan Review Corn. QOctober 28, 2008 Plan Review Corn. A- A A Sheet No: FA,01 I I SHEET 2 OF 9 '1