08-963-006N TYPICAL EACH FOUND. CORNER: PROVIDE 2 #5 BENT BARS EXTENDING 48 BAR DIAMETERS FROM EACH END. 14' --7" E CO A 2 I O j NEW FAMILY AROOM. ' 2 21 N I I i 4" CONCRETE SLAB W/ 6X6X10/10 WWM ON VISQUEEN MEMBRANE ON COMPACTED FILL,TERMITE TREATED. TO MATCH EXISTING FIN FL. ELEV. O1 I I O 00 I O 1 0 I I ID NOTE: PROVIDE 6G)15 RENARS TWO AT G" FR M OP AND ■DTTOM AND TWO AT MIDHEIGHT OF COL '1 ", SET W/ EPDXY 4" MIN. INTO EXIST. COLUM ' E A I ATI FOUND N PLAN FOUNDATION CONC. TIE BEAM � O W O O W 1 r G.R 250.3 LB \ 394.5 LB r_(D BEAM SCHEDULE -------------------------- SIZE REINFORCING STIRRUPS - - - - -- MARK -- - 1 ( #3 CLOSED TIES) REMARKS I I I i I I I 8X8 1 # 5 # ,5 24 OC CONCRETE BLCK FILLED W GROUT STEM WALL FOUND. W H TOP BOTTOM MIDHT I I I I I TB 8" 12" 2. # 5 2 # 5 -- PROVIDE #3 TIES 48" OC THRUOUT THE TIE BEAM DROP OVER OPENINGS A MINIMUM OF s" EACH SIDE & RKB I I I I I I AND (4) #3 TIES 12 OC FROM EACH END OF BUILDING. ADD 2 #5 BOTT. & #3 TIES 10" OC. 0 -------------------------- SIZE REINF TIES - - - - -- A -- - 1 NOTE: PRO yDE (i) 5 RENARS TWO AT G FROM OR AND NOTTOM AND TWO AT MIDHEIGHT OF COL. 1 ", SET W/ EPDXY 4" MIN. INTO EXIST. COLUMN '(D SCALE: 1/4" = 1' -0" NEW BEAM 2 # 5 DOWELLS DRILLED IN W/ EPDXY RESIN EXIST. WALL BEAM CONNECTION DETAIL 13 G,R 615 Lli U.L 1617.2 psf G,R 1140 LB U.L 2072.86 psf 3 915 LB 1523.32 psf -- EXISTING ROOF LINE SCALE: 1/4" = F -0" COLUMN SCHEDULE -------------------------- SIZE REINF TIES - - - - -- - - - -- -- - - - - - -, �W _= CONCRETE COLUMN I I I i I I I 8X8 1 # 5 # ,5 24 OC CONCRETE BLCK FILLED W GROUT STEM WALL FOUND. I I I I I I I I I I I I I II I I I I I E I I I I i I UI I I I I I I 1 I I I I I I I I I i I I I I PROPOSE TO MATCH EXIST. I 1 I I G,R I i i U.L I O W Z I I I I I I I I I I I I — ------------------------------------------------ I I I I I I L------ .—.... ----- -- - --I I I I I I I I I I I 13 G,R 615 Lli U.L 1617.2 psf G,R 1140 LB U.L 2072.86 psf 3 915 LB 1523.32 psf -- EXISTING ROOF LINE SCALE: 1/4" = F -0" COLUMN SCHEDULE MARK SIZE REINF TIES REMARKS 1 8X12 4# 5 �W _= CONCRETE COLUMN O 8X8 1 # 5 # ,5 24 OC CONCRETE BLCK FILLED W GROUT FOUNDATION SCHEDULE MARK SIZE REINFORCING REMARKS D SW LW SW �W ZL16" O 20" CONT. # ,5 24 OC 2 #5 STEM WALL FOUND. E EXISTING FOUNDATION SOIL STATEMENT AS PER VISUAL INSPECTI ❑N, S ❑IL CONDITION AT THIS SITE ARE SAND AND ROCK W/ MIN, BEARING CAPACITY OF 2000 P,S.F AT THE TIME OF CONSTRUCTION THE ENGINEER SHALL SUBMIT TO THE BUILDING OFFICIAL A LETTER ATTESTING THAT THE SITE HAS BEEN OBSERVED AND THAT THE FOUNDATION CONDITIONS ARE SIMILAR TO THOSE UPON WHICH THE DESIGN IS BASED, THE RESIDENCE SHALL HAVE A PRE- C❑NSTRUCTI ❑N TREATMENT FOR PROTECTI ❑N AGAINST SUBTERRANEAN TERMITE. A CERTIFICATE OF COMPLIANCE SHALL BE ISSUDED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY WICH CONTAINS THE FOLLOWING STATEMENT, 'THIS RESIDENCE HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUB- TERRANEAN TERMITE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS AS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES,' TRUSS CONNECTOR SCHEDULE MARK MANUF, NUMWER NAILING CAPACITY (LBS) N.O.A 0 NVHTA 20 NU -VUE 20 -16d 2,133 LBS 03- 0224.10 O NVRT 20 NU -VUE 14 -16d 1,059 LBS 03-- 0327.14 8860 SW 33 Miami, Florida 331552'' 305 - 4808013 i F GALV. STEEL STRAP & SEAT EA. TRUSS BENT OVER & NAILED AS PER CONNECTION SCHEDULE �l Top of Beam (87 ) 1X6 FASCIA NAILED TO 2X4 SUB — FASCIA W/ 8d NAILS @ • 4" O.C. GALV. METAL FLASHING ON 1x2 P.T NAILER ON 1X6 FASCIA STUCCO ON RIBBED METAL LATH W/3 "X24" SCREENED VENTS AT 8' -0" O.C. 1/150x312 =2.08 SF MIN. ATTIC VENTILATION GALV. HURRICANE CLIPS NAILED TO 2X4 P.T. FASTENED W/1/4" "TAPCONS" 4 LONG AT 24" O.C.,2' INTO TBM PAINT COATS 5 /8 STUCCO ON 8" CONIC. BLOCK WALLL J� 0' -0" FIN FL. N ' U•i • • t • • N it u Ci • i Y Y • f! u4u ' • W • 1 W Y f • W r•G (•u 11 •fr! • t r • M Y • 11 N • • F 1 W •••• GOA NW 4Sr- fiYJ • ASPHALT SHINGLES ON 30 "FELTYWW. ••� TIN-- TAGGED TO 19/32 EXTERIOR • r • " L+•W• • 4u•rG a uf c rf"u W PLYW. SHEATING W / "H" CLIPS VERIFY SHALL BE 19/32" CDX EXTERIOR GRADE LO 12 PLYWOOD AND HAVE STAGGERED JOINTS SITE 3 AND SHALL BE FASTENED 4" O.C. ALONG PERIMETER AND 6" O.C. IN FIELD. USE 8d RING SHANK GALV. NAILS. NAILING SHALL BE IN CONFORMANCE WITH FBC 1507. R -19 INSULATION 1/2" GWB ON 1 XSS AT 16" O.C. ON TRUSSES P.T 1X3 CONT. FIRE STOP 8 "X12 CONC.TIE BEAM W/ 4 #5 CONT. TYPICAL NOTE: ;DROP OVER OPENINGS 8" EACH SIDE AND ADD 2 #5 Ec #3 TIES AT 10" O.C.. PROVIDE #3 TIES 48" OC THRUOUT THE TIE BEAM AND (4) #3 TIES 12 "OC FROM EACH END OF BUILDING. —1/211 GWB ON P.T. 1 X2'S AT 24" O.C. W/ R -4.2 INSULATION PROVIDE STANDARD #9 GAGE LADDER TYPE JOINT REINFORCEMENT AT EVERY SECOND COURSE (16" VERTICALLY) FOR ALL EXTERIOR WALLS AND EXTEND 4" INTO TIE COLUMNS OR TIE TO STRUCTURAL COLUMNS 4" WOOD BASE 1/2" EXPANSION JOINT 4" CONC. SLAB W/6 X 6 X 10/10 W.W.M. ON WATER PROOF MEMBRANE ON WELL COMPACTED FILL hik WELL COMPACTED FILL TERMITE TREATED SEE FOUNDATION SCHEDULE �43"COVER T Y P I CAL WALL SE C T O N SC: 3/4 = 1' -0" GALV. STEEL STRAP & SEAT EA. TRUSS BENT OVER & NAILED AS PER CONNECTION SCHEDULE. 8 "X12" RAKED BEAM 2 X 4BLOCKING @ EA.BRACE. TOP W/3 -16d TOE NAIL 19/32" COX PLY. SHAFTING CAP W/ 2 #5 CONT. TO TRUSS / CAP W/ 2 #5 CONT. 1X6 FASCIA NAILED TO 2X4 SUB— FASCIA W/ 8d NAILS @ 4" O.C. 1#5 OIN CONC.FILLED CELL @48" 0/C i 2" X 6" WD. LEDGER W /1/2 "O X 3-1/2" L.EXP.BOLTS @24" 0/C IN GROUNTED CELL TOP OF TBM ELEV.. 5/8" TUCCOIN(2 COAT) ON CONIC. BLOCK. 2 "X4" X BRACING AT RIDGE AT 5 0/ . STARTING WHERE GABLE HEIGHT EXCEEDS 3' -0" CONNECT TO 2" X ' W/3 -16d NAILS EA. END PROVIDE MP BY USP W /10 -8d GALV. NAILS(X 1-1/2") AT BOTH ENDS OF VERT. BRACING PR FAB. WOOD TR SSES @ 24" O.C. AS PER MNFTR. SPCS General Notes NOTE: THESE PLANS COMPLY WITH THE APPLICABLE MINIMUN REQUIREMENTS OF F. B. C. Seal: NESTOR CIFUENTES' P.E. Florida him 24460 ! #o: Lv Ir. TERR ;% 8860 SW 33 Miami, Florida 331552'' 305 - 4808013 i F Project Name and Address I ADDITION TO EXIST. RESID N LOCATED AT 6566 SW 59 C MIAMI, FL. I Ii II I1 0 For revision I j ND. Revision /Issue 1/2" GBW ON P.T 1 X3'S @ 16" I DRAWN O.C. ON WOOD TRUSSES @ 2' -0" i O.C. P.T 1X3 CUNT. FIRE STOP 8 "X12" CONIC. TBM. W/ (4) #5 CONT. �p1D"[Yt 1 j "' ,#3 TIES 4 @12" 0/C CORNERS CyT�urlF.D1NG Chcck•�I 048" ELSE', WHERE( 2 #5030 "X30" BENT @ CORNERS) D !STRUC Owners approval Apn�icry RY_ PP SECTIO @ GABLE END SCALE: NTS S1 Date AUG, 2008 i �d