08-963-001K GENERAL: 1. THE DRAWINGS ARE INTENDED TO SHOW THE GENERAL ARRANGEMENT, DESIGN AND EXTENT OF THE WORK AND ARE PARTIALLY DIAGRAMMATIC. THEY ARE NOT INTENDED TO BE SCALED FOR ROUGH -IN MEASUREMENTS, OR TO SERVE AS SHOP DRAWINGS OR PORTIONS THEREOF. 2. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, EXCEPT WHERE A DIFFERENT DETAIL OR SECTION IS SHOWN 3. PRIOR TO START OF CONSTRUCTION, THE CONTRACTOR AND ALL THE SUBCONTRACTORS SHALL VERIFY ALL GRADES, LINES, LEVELS, DIMENSIONS AND COORDINATE EXISTING CONDITIONS AT THE JOB SITE WITH THE PLANS AND SPECIFICATIONS. THEY SHALL REPORT ANY INCONSISTENCIES OR ERRORS IN THE ABOVE TO THE ARCHITECT /ENGINEER BEFORE COMMENCING WORK. THE CONTRACTOR AND HIS SUBCONTRACTORS SHALL LAY OUT THEIR WORK FROM ESTABLISHED REFERENCE POINTS AND BE RESPONSIBLE FOR ALL LINES, ELEVATIONS AND MEASUREMENTS IN CONNECTION WITH THEIR WORK. 4. IF ANY ERRORS OR OMISSIONS APPEAR IN THE DRAWINGS, GENERAL NOTES OR OTHER DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IN WRITING OF SUCH OMISSION OR ERROR PRIOR TO PROCEEDING WITH ANY WORK WHICH APPEARS IN QUESTION. IN THE EVENT OF THE CONTRACTOR'S FAILING TO GIVE SUCH AN ADVANCED NOTICE, HE SHALL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY SUCH ERRORS, OR OMISSIONS AND THE COST OF RECTIFYING THE SAME. 5. THE CONTRACTOR SHALL USE THE STRUCTURAL DRAWINGS AND SPECIFICATIONS TOGETHER WITH THE ARCHITECTURAL, MECHANICAL, ELECTRICAL AND OTHER TRADE DRAWINGS AND SHOP DRAWINGS, TO LOCATE DEPRESSED SLABS, SLOPES, DRAINS, OUTLETS, RECESSES, OPENINGS, BOLT SETTING, SLEEVES, DIMENSIONS, ETC. NOTIFY ARCHITECT /ENGINEER, IN WRITING, OF ANY POTENTIAL CONFLICTS BEFORE PROCEEDING WITH THE WORK. STRUCTURAL OBSERVATIONS: 1. DADE COUNTY REQUIRES THAT THE ENGINEER -OF- RECORD SUBMIT A STATEMENT, AT THE COMPLETION OF THE CONSTRUCTION WORK, REGARDING THE COMPLIANCE OF THE WORK WITH THE APPROVED PERMIT PLANS. 2. IN ORDER TO COMPLY WITH THE ABOVE, A/E MUST BE RETAINED AS THE STRUCTURAL INSPECTOR, AND NOTIFIED AT LEAST 24 HOURS PRIOR TO ANY CONCRETE PLACING OR OTHER OPERATIONS THAT WILL CONCEAL STRUCTURAL ELEMENTS. UNLESS EVERY STRUCTURAL ELEMENT WAS ADEQUATELY OBSERVED BY THE A /E, THE A/E WILL NOT ISSUE THE REQUIRED "STATEMENT OF INSPECTION ". 3. IT IS UNDERSTOOD THAT A/E WILL NOT BE HELD RESPONSIBLE AND LIABLE FOR ANY OF THE CONTRACTOR'S WORK WHICH WAS NOT PROPERLY OBSERVED BY THE A/E OR FOR ANY WORK, APPROVED BY OTHER INSPECTING ENGINEER (OTHER THAT THE A /E- OF- RECORD) WHICH MODIFIES OR CHANGES THE STRUCTURAL PERMIT RECORD DOCUMENTS. STRUCTURAL DESIGN CRITERIA: 1. THE DESIGN COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE - (2004 EDITION) 2. WIND LOAD CRITERIA: BASED ON ANSI /ASCE 7 -02. BASIC WIND VELOCITY 146 MPH, OCCUPANCY CATEGORY II (AT HURRICANE OCEANLINE), EXPOSURE "C" 3. ROOF DESIGN LOADS: DEAD LOADS: . . . . . . 15 PSF LIVE LOADS: . . . . . 30 PSF FOUNDATIONS: 1. FOUNDATIONS 'ARE DESIGNED TO BEAR ON WELL COMPACTED GRADE OR CLEAN FILL OF AN ALLOWABLE BEARING CAPACITY OF 2,000 PSF MINIMUM. AT THE TIME OF CONSTRUCTION, A LICENSED (ARCHITECT) (REGISTERED PROFESSIONAL ENGINEER) SHALL SUBMIT TO THE BUILDING OFFICIAL A SIGNED AND SEALED LETTER ATTESTING THAT THE SITE HAS BEEN OBSERVED AND THE FOUNDATION CONDITIONS ARE SIMILAR TO THOSE UPON WHICH THE DESIGN IS BASED. 2. NATURAL GRADE (OR FILL) BELOW FOOTINGS SHALL BE COMPACTED TO 95% MODIFIED PROCTOR (ASTM D- 1557). 3. TOP OF WALL FOOTINGS TO BE AT THE SAME ELEVATION AS TOP OF COLUMN PAD FOOTINGS. STEP WALL FOOTING FROM HIGHER COLUMN FOOTING TO THE LOWER ONE (AS DETAILED ON THE PLANS). 4. TOP OF ALL FOOTINGS TO BE A MINIMUM 1' -0" BELOW THE TOP OF CONCRETE SLAB ON GRADE (UNLESS OTHERWISE NOTED) OR MINIMUM 1' -0" BELOW FINISHED GRADE, WHICHEVER IS LOWER. IN THE EVENT THAT THE SLAB STEPS ON EACH SIDE OF THE FOOTING, THE FOOTING SHALL BE 1' -O" BELOW TOP OF THE LOWER SLAB. 5. REINFORCING IN THE CONTINUOUS WALL FOOTINGS (MONOLITHIC AND NON - MONOLITHIC) SHALL BE SPLICED 36 BAR DIAMETERS MINIMUM AND SHALL EXTEND CONTINUOUSLY THRU ALL FOOTING PADS. 6. ALL LONGITUDINAL REBARS IN THE CONTINUOUS WALL FOOTINGS, SHALL BE CONTINUED AT BENTS AND CORNERS BY BENDING THE REBARS 48 BAR DIAMETERS AROUND THE CORNERS OR ADDING MATCHING CORNER BARS, EXTENDING 48 BAR - DIAMETERS INTO FOOTING EACH SIDE OF CORNER OR BENT. 7. ALL FOOTINGS SHALL BE 12" MINIMUM THICKNESS. MASONRY WALLS: 1. ALL REINFORCED MASONRY WALLS SHALL BE PROVIDED WITH #9 DUR -O -WALL LADDER TYPE HORIZONTAL REINFORCEMENT AT 1' -4" VERTICALLY LAPPED 7-1/2" AND EXTENDED 4" INTO CONCRETE COLUMNS. PROVIDE SPECIAL HORIZONTAL REINFORCING AT "T" AND "L" INTERSECTION. PROVIDE "DOVE - TAIL" ANCHORS AT 16" O.C. VERTICALLY FOR ALL MASONRY PLACED ADJACENT TO ALREADY IN PLACE COLUMNS. 2. CONCRETE MASONRY UNITS: ASTM C90, GRADE N -1, MODULAR, MINIMUM NET COMPRESSIVE STRENGTH AT 28 DAYS f'c = 1900 PSI. 3. MORTAR: ASTM C270, TYPE S. MORTAR ALL FACE SHELLS, AND CROSS SHELLS AROUND ALL GROUT FILLED CELLS WITH A MINIMUM STRENGTH 2000 PSI (USE PORTLAND TYPE CEMENT). 4. DENOTES BEARING CONC. BLOCK WALL. INSTALL BLOCK BEFORE CASTING ADJACENT COLUMNS AND BEAMS. 5. GROUT: ASTM C476. COARSE GROUT. SLUMP '8" MINIMUM ; 11" MAXIMUM COMPRESSIVE STRENGTH AT 28 DAYS = 3000 PSI. SUBMIT DESIGN MIX FOR REVIEW. 6. DESIGN F'M = 1500 PSI. 7. ANY MASONRY OPENINGS BETWEEN 3 AND 8 FT. IN WIDTH SHALL HAVE VERTICAL BARS IN CONCRETE FILLED CELLS ON EACH SIDE OF OPENING AS INDICATED IN THE FOUNDATION PLAN (AND ANY OTHER FLOOR IF APPLICABLE). THESE REBARS SHALL BE HOOKED AT THE FOUNDATION AND AT THE TIE BEAM AND LAPPED 48 BAR DIAMETER MINIMUM. 8. PLACE ALL MASONRY UNITS IN RUNNING BOND. 9. PROVIDE KNOCK --OUTS AT BASE OF ALL CELLS CONTAINING REINFORCING. 10. MAXIMUM POUR LIFT = 4' -0" 11. INTERSECTING WALLS: BONDED AT LOCATIONS WHERE THEY MEET OR INTERSECT BY THE FOLLOWING METHOD: FIFTY PERCENT OF THE UNITS AT THE INTERSECTION SHALL BE LAID IN AN OVERLAPPING MASONRY BONDING PATTERN, WITH ALTERNATE UNITS HAVING A BEARING OF NOT LESS THAN 3 INCHES ON THE UNIT BELLOW. 12. VERTICAL REINFORCEMENT SHALL BE SPLICED 48 BAR DIAMETER MINIMUN. 13. PROVIDE VERTICAL REINFORCEMENT AS INDICATED ON FOUNDATION PLAN AT EACH SIDE OF WALL OPENING AND @ INTERSECTING WALLS. 14. SPECIAL INSPECTION IS REQUIRED. STRUCTURAL LUMBER WOOD: 1. TO CONFORM TO RULES OF THE MANUFACTURER'S ASSOCIATION UNDER WHOSE RULES THE LUMBER IS PRODUCED. (SEE SUPPLIER'S SPECIFICATIONS). 2. TO BE AIR DRIED, WELL SEASONED AND GRADE MARKED AT MILL. 3. TO BE NO. 2 SOUTHERN PINE. 4. ALL STRUCTURAL WOOD TO BE SURFACED FOUR (4) SIDES (S -4 -S) WITH A MINIMUM FIBER STRESS IN BENDING OF 1,200 P.S.I. AND A MAXIMUM MOISTURE CONTENT OF 19 PERCENT. 5. ALL LUMBER AND PLYWOOD IN CONTACT WITH CONCRETE, STUCCO, MASONRY OR OTHER CEMENTATIOUS MATERIALS SHALL BE TREATED TO COMPLY WITH AWPA STANDARD LP -2. 6. STORE ALL LUMBER ABOVE GRADE OR FLOOR. STACK TO ALLOW PROPER AIR CIRCULATION AND PROTECT FROM WETTING WITH SUITABLE COVER. SOUTHERN PINE, UTILITY GRADE DOUGLAS FIR OR WEST COAST HEMLOCK. CONCRETE SLABS ON GRADE: 1. ALL INTERIOR AND EXTERIOR SLABS AND WALKWAYS AS SHOWN ON THE STRUCTURAL OR ARCHITECTURAL PLANS, SHALL BE FOUR INCHES THICK MINIMUM REINFORCED WITH 6 X 6 - W1.4 X W1.4 WELDED WIRE FABRIC (UNLESS OTHERWISE NOTED). 2. WIRE MESH SHALL HAVE A MINIMUM OVERLAP OF 12" UNLESS OTHERWISE NOTED IN PLANS. 3. ALL SLABS ON GRADE TO BE CONSTRUCTED IN ACCORDANCE WITH LATEST A.C.I - GUIDE FOR CONCRETE FLOOR AND SLAB CONSTRUCTION" (A.C.I. - 302.1R). 4. JOINTS SHALL BE PROVIDED IN ALL INTERIOR SLABS ON GRADE, DIVIDING THE SLAB INTO SQUARE PANELS. SEE PLAN FOR SAW -CUT, CONTRACTION AND ISOLATION JOINT INFORMATION. 5. PROVIDE SAW -CUT JOINTS AT ALL SIDEWALKS AT A MAXIMUM SPACING OF FIVE FEET ON CENTERS AND ISOLATION JOINTS AT 20 FEET O.C. (U.O.N.). 6. FILL MATERIAL SHALL BE PLACED IN LIFTS NOT EXCEEDING 12" AND COMPACTED TO 95% MODIFIED PROCTOR (ASTM D -1557) WITHIN A DISTANCE OF 3 FEET BEYOND ALL FOOTING EDGES. TAKE AT LEAST ONE DENSITY TEST FOR EACH 1,600 SQ.FT. OF AREA AND 12" BELOW SURFACE. SEND RESULTS OF THE TEST TO OWNER, ARCHITECT AND ENGINEER. CONCRETE AND REINFORCING: 1. CONCRETE DESIGN AND REINFORCEMENT IN ACCORDANCE WITH "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (A.C.I. 318 -02 / 318R -02) AND WITH "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT" (A.C.I. 315R -94). 2. ALL CONCRETE WORK IN ACCORDANCE WITH "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDING „ (A.C.I. 301 - LATEST EDITION). PRODUCTION OF CONCRETE, DELIVERY, PLACING AND CURING TO BE IN ACCORDANCE WITH "HOT WEATHER CONCRETING" (A.C.I. 305R - LATEST EDITION). 3. ALL CONCRETE TO BE REGULAR WEIGHT WITH AN COMPRESSIVE STRENGTH OF 3,000 P.S.I. AT 28 DAYS. MAXIMUM SLUMP 3" MIN. TO 5" MAX. 4. ALL REINFORCING TO BE NEW BILLET STEEL CONFORMING AS PER ASTM A -615 GRADE 60, FABRICATED IN ACCORDANCE WITH C.R.S.I. MANUAL OF STANDARD PRACTICE AND PLACED IN ACCORDANCE WITH A.C.I. :315 AND C.R.S.I. MANUAL OF STANDARD PRACTICE. 5. CONCRETE COVER UNLESS OTHERWISE DETAILED ON DRAWINGS: FOOTINGS: (BOTTOM) • ' . . ' 3„ (TOP do SIDES) ' ' • . • . 2„ SLABS ON GRADE: . . . . . . MID DEPTH OF SLAB COLUMNS AND BEAMS: . . . . 1- --1/2" 6. COLUMN REINFORCEMENT: DOWELS TO BE SAME SIZE AND NUMBER AS VERTICAL REBARS ABOVE. LAP 36 BAR DIAMETER OR MINIMUM OF 18 INCHES, U.O.N. PROVIDE RIGID TEMPLETS FOR DOWEL LOCATION, PROVIDE STANDARD HOOKS AT TOP OF ALL VERTICAL REINFORCEMENT AT NONCONTINUOUS COLUMNS (U.O.N.). 7. ALL DOWELS FOR COLUMNS SHALL BE SECURED IN POSITION PRIOR TO CONCRETING. PUSHING THE DOWELS INTO POSITION IN WET CONCRETE IS NOT PERMITTED. 8. BEAM REINFORCEMENT: LAPPED 36 BAR DIAMETER OR MINIMUM 18 INCHES (SEE BEAM DIAGRAM ON PLAN). BOTTOM BARS SPLICED ONLY AT SUPPORTS, TOP BARS SPLICED ONLY AT MID -SPAN. ALL TOP BARS HOOKED AT NONCONTINUOUS EDGES (U.O.N.). ALL HOOKS TO BE STANDARD 90 DEGREE HOOKS AS REQUIRED (U.0.N.). 9. ADDED REINFORCEMENT: PROVIDE ADDITIONAL CORNER BARS BENT 36 INCHES MINIMUM EACH WAY AT "L" AND "T" CORNERS IN OUTER FACES OF ALL BEAMS TO MATCH ALL HORIZONTAL BAR (TOP, BOTTOM AND INTERMEDIATE REBARS). 10. SEE PLAN FOR MINIMUM SIZE CONCRETE TIE BEAM REQUIREMENTS. U 1 U• • I G V U / V V V u G� • U • • G• V V V • G GUI G G IJ • • V Y • r r G G - V UVY G V• V U r .,• V Y • G I G •u G• ••• � • r r r G G r r• t I V ti G V • • Y • !. • • •GG • y ••• • Y, Y V• V .w V • G V• • U V • t • • V•IU • • 1 • • • • • t • • ►R. 1 r7n% f L CITY OF SOUTH MIAN'II BUILDING DEPT. STRUCTUMt, -- tIGTION APPRQVCQ BY: DATE: I