Loading...
12-528-005i NIAGARA INDUSTRIES'INC. TITAN TANKLESS WATER HEATER (Ncl^ OB Cp1I�t•t72� THE HEATER INCORPORATES A HEATING ELEMENT HOUSED WITH IN A HEATER EXCHANGER, AN ELECTRICAL COMPONENT MONITORS THE TEMPERATURE-OF THE WATER HEATER AT DIFFERENT.FLOW RATES MAINTAINING A PRE SET TEMPERATURE ALLOWING THE.USE OF CONVENTIONAL OR SINGLE HANDLE FAUCETS to- MODEL MAX KW at 220 V VOLTS MAX AMPS o1220 V N. 120 11.8 KW 220 V S4 t4. 100 10.8 KW 220 V 49 N -85 83 KW 220V. 38 N-75 73 KW 220 V 34 N'• 6+1 6.4 KW 120 V 29 N.A2 4.2 KW .220V 19 -*N -10 3.2 KW '. I Ito V 29 1. Heat Chamber 2. Float Cavity 3. P.C. Board 4. Resistor S. Left Side 6. Front 7. Switch 8. Water Out 9. Water In PLUMBING GENERAL NOTES : 1. ALL WORK AND MATERIAL SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, LOCAL AND ANY OTHER PERTAINING CODES THAT APPLY. 2. THE CONTRACTOR SHALL PROVIDE ALL MINOR ITEMS WHICH ARE OBVIOUSLY, AND REASONABLY NECESSARY TO COMPLETE THE INSTALLATION. 3. THE CONTRACTOR SHALL TAKE OUT PERMITS, PROCURE CERTIFICATES AND PAY ALL FEES CONNECTED THEREWITH. 4. BIDDERS SHALL VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH ALL CONDITIONS SURROUNDING THE WORK. 5. THE CONTRACTOR SHOULD REFER TO THE DRAWING AND SPECIFICATIONS OF OTHER TRADES, AS SUCH ARE TO BE CONSIDERED PART OF THE PLUMBING CONTRACT DOCUMENTS. 6. DRAWINGS ARE DIA GRAMMATIC AND INTENDED TO SHOW THE APPROXIMATE LOCATION AND ARRANGEMENTS ONLY. PROVIDE ALL OFFSET, FITTING OR ACCESSORIES REQUIRED FOR A COMPLETE INSTALLATION. 7. ALL MATERIALS SHALL BE NEW AND OF THE BEST QUALITY NORMALLY USED FOR THE PURPOSE, OF TYPE AND MAKE CALLED FOR , OR APPROVED EQUAL. 8. THE CONTRACTOR SHALL BE A LICENSED MASTER PLUMER. 9. THE ENTIRE INSTALLATION SHALL BE PERFORMED IN A FIRST —CLASS WORKMANLIKE MANNER. 10. PLUMING WORK SHALL NOT INTERFERE WITH CLEARANCE REQUIRED FOR GENERAL AND HVAC CONSTRUCTIONS. INSTALLED PLUMBING WORK WHICH INERFERES WITH THE WORK OF OTHER CONTRACTOR SHALL BE CHANGED AT THE PLUMBING CONTRACTORS EXPENSE. 11 AS PER F.B.C. 604.9 Water hammer. The flow velocity of the water distribution system shall be controlled to reduce the possibility of water hammer. A water — hammer arrestor shall be installed where quick — closing valves are utilized, unless otherwise approved. The arrestor shall be located within an effective range of the quick — closing valve. Water— hammer arrestors shall conform to ASSE 1010. Access shall be provided to water — hammer arrestors. FROM W/M SHUT -OFF VALVE 1" SERV. OPEN VA 1, COLD & HOT WATER ISOM. UNIT -A NOTE : NO FITTING JOINTS UNDER SLAB. ALL PRIMARY LINES TO H.W BATHROOMS, KITCHEN & LAUNDRY TO FINISH ABOVE SLAB. SANITARY RISER 3" INTEGRAL NOTES: O 2" PIPE OR LESS TO DRAIN ® 1/4" SLOPE 3" PIPE OR MORE TO DRAIN ® 1/8" SLOPE INTEGRAL O2 PROVIDE ANTI —SCALD VALVES FOR TUBS AND SHOWER HEADS i COLD WATER HOT WATER PLUMBING FIXTURE SCHEDULE SYMBOL FIXTURE WASTE TRAP VENT .W. H.W REMARKS WC WATER CLOSET 3" INTEGRAL 1/2" HWC WATER CLOSET 3" INTEGRAL 1/2" HANDICAPPED LAV LAVATORY 1 -1/2" 1 -1/2• 1/2" 1/2- COUNTER TOP HLAV WALL LAVATORY 1 -1/2" 1 -1/2" 1/2" HANDICAPPED BD BIDET 2" 2" 1/2" BT BATH TUB 2" 2" 1/2" 1/2" SK STAINLESS SINK 1 -1/2" 1 -1/2- 1/2" 1/2" DOUBLE COMPARTMENT DW DISH WASHER 1 -1/2" 1 -1/2- 1/2" 1/2" WM WASHING MACHINE 2" 2" 1/2" 1/2" NOTE 1: PROVIDE VACUUM BREAKER FOR ALL HOSE BIBS & BIDETS NOTE 2: SHOWER VALVE W/ TEMPERATURE PRESURE BALANCE — MIXING VALVE I L_ v I V I LJ 1 1 V \J I L_ F_\ 1 v SCALE 1/409=1 '-0" N W O 1 11 W LO 0 r- C14 Z_ p J O r� of Z M •L I (n O��O M E I 0) o /_ r- In r ti: t I- /! C) a i J w s K O O LL z W O w IY O w I— z M r� Rr�r� �`�< L j#gf 4. V's (� cn o L0 CO REMSIONI: REVISION2 REMSION3 REMSION4 SHEET P I