12-528-003LEGEND
ELECTRICAL OUTLET
-�- LIGHT RECEPTACLES
1 -WAY SWITCH
®D COMBO SMOKE /CARBON MONOXIDE DETECTOR
® ELECTRICAL OUTLET
$3 3 -WAY SWITCH
% E.F. EXHAUST FAN
HI -HAT
FLUORESCENT LIGTH
ELECTRICAL PANEL
ELECT. DISCONNECTOR
FAN W/ LIGHT
V PHONE
TV CABLE
GENERAL ELECTRICAL NOTES
ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW BASE
FLOOD ELEVATION SHALL BE INSTALLED AT THE HIGHEST PERMITTED
ELEVATION AND SHALL BE INSTALLED ON (SEPARATE) INDEPENDENT
CIRCUITS FROM THOSE IN THE HABITABLE AREAS.
NO APPLIANCES OR APPLIANCE OUTLETS SHALL BE INSTALLED BELOW
BASE FLOOD ELEVATION.
- A/C COMPRESSOR SHALL BE INSTALLED ABOVE BASE FLOOD
ELEVATION.
- MAIN CIRCUIT BREAKER PANELS SHALLBE LOCATED ABOVE BASE
FLOOD ELEVATION.
- WE WILL CONFER WITH FLORIDA POWER & LIGHT TO LOCATE THE
ELECTRIC METER TO COMPLY WITH FEDERAL EMERGENCY MANAGEMENT
AGENCY REQUIREMENTS.
ALL ELECTRICAL WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY
WITH LOCAL CODES AND ORDINANCE & ALL STANDARDS OF CONSTRUCTION
ESTABLISHED BY THE LANDLORD.
- ALL CONDUCTORS SHALL BE TWH OR THWN COPPER. ALL EXPOSED
CONDUITS SHALL BE RUN AS NEAT AS POSSIBLE AND PAINTED TO MATCH
COLOR OF SURROUNDINGS. P.V.C. CONDUIT SHALL ONLY BE USED IN
SLAB OR UNDERGROUND AT A MINIMUM DEPTH OF 24 ".
FLEXIABLE CONDUIT SHALL BE USED FOR CONNECTION TO ALL
VIBRATING EQUIPMENT SUCH AS MOTORS, ETC.
- ALL WIRING DEVICES SHALL BE LEVITON "DECORA" SERIES OR EQUAL
AS APPROVED BY ARCHITECT OR ENGINEER. COLOR SELECTED BY
ARCHITECT.
- ALL RECEPTACLES SHALL BE INSTALLED AT 12 "A.F.F. UNLESS
OTHERWISE NOTED.
- ELECTRICAL POWER AND CONTROL WIRING FOR HVAC AND MECHANICAL
EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL
CONTRACTOR.
ELECTRICAL CONTRACTOR SHALL VERIFY THE CEILING FINISHES AND
SUSPENSION SYSTEM FOR SELECTION OF THE PROPER TRIM AND SUPPORT
ARRANGEMENT OF THE FIXTURE.
- ELECTRICAL CONTRACTORS SHALL COORDINATE HIS WORK WITH THE
ARCHITECT BEFORE ROUGH INSTALLATION OF LIGHTS, RECEPTACLES,
SWITCHES AND EQUIPMENT FOR EXACT LOCATIONS.
- ALL ELECTRICAL EQUIPMENT MUST BE U.L. APPROVED.
luti :111
SWITCH LEG
TO F.P.L P
AS PER NEC
250.94
SMOKE DETECTOR
SWITCH
LINE SIDE 1 120 V
OF SWITCH
PHASE CONDUCTOR
COMBO
SMOKE DETECTOR O A NON/ SWITCHABLERLGHTING BE HARDWIRED (110 V TYPR)
CONNECTION DETAIL NTS CIRCUIT WITH BATTERY BACK -UP AND SHALL NOT BE
CONNECTED ONTO THE LOAD SIDE OF GROUND FAULT
COMBO SD /CM DETECTOR CIRCUIT INTERRUPTER ALL SMOKE DETECTORS WITHIN EACH
SHALL NOT BE PLACED UNIT SHALL BE INTERCONNECTED
WITHIN 3 FT. OF ANY SO ALL DETECTORS SOUND WHEN ANY DETECTOR IS ACTIVATED
A/C GRILL. AND COMPLY W/ N.E.0 210 -12
COMBO SD /CM DETECTOR SHALL BE INSTALLED WITHIN 3' OF ALL BEDROOMS
3 -1 /0 THW
IN 2 " CONDUIT
50 A.
O DI C.BRKR
0 00
GROUND ELECTRODE
1 # 6 THW CU TO FOUNDATION REBAR
(AS PER N.E.C.) CWP & GAS PIPE
ELECTRICAL RISER DIAGRAM
120/240V ELECTRIC PANEL A 150 AMPS. MCB
1 PH, 3W SURFACE MTD.
CIRCUIT
FUNCTION
VOLTS
C/B TRIP
WIRE
LOAD
C- 1,3
STRIP HEATER /BLOWER #1 (7.5 KW)
240
2P -60
#6
7500
C- 2,4
A/C # 1 CONDENSING UNIT
240
2P -40
#8
(4000)
C- 5
MICROWAVE
240
1P-20
#12
1500
C- 6
REFRIGERATOR
120
1 P -20
#12
1500
C -7
DISPOSAL
120
1 P -20
#12
1000
C -8
WASHER
120
1P-20
#12
1500
C- 9
DISHWASHER
120
1 P -20
12
1200
C -10,12
RANGE
240
2P -50
#6
12000
C -11
G.F.I. OUTLETS BATHROOMS
120
1P-20
#12
1500
C- 13,14,15
SMALL APPLIANCES
120
1 P -20
#12
4500
C -16,18
DRYER
240
2P -30
#10
5000
C -17,19
WATER HEATER
240
2P -50
#6
11000
C -20 -26
LIGHT & RECEPT.
120
1 P -15
#14
4515
C -27 -30
SPACES
FLOOR AREA = 1505 S.F.® 3 WATTS = 4515 TOTAL LOAD = 55215
ELECTRICAL LOAD CALCULATIONS
CONNECT LOAD LESS A/C = (55.2 -7.5) 47.7 KW
10 KW @100% = 10.0 KW
37.7 REST @ 40% = 15.08 KW
A/C OHTNG 100% = 7.5 KW
DEMAND LOAD = 32.6/240 = 136 AMPS.
NOTE: ALL ELECTRICAL EQUIPMENT
WIRING RATED ® 75"' C
ELECTRICAL
METER W/
MAIN DICONN.
PANEL A
WP
C -16,
C -20
GFI /WP
b AC -20
ELECTRICAL PLAN
SCALE 1/4"=l'-O"
NOTE
- ALL CIRCUITS WHO FEENDING ALL MONOFASICS OUTLET
OF 125V & 15A & 20A , INSTALL IN ALL AREAS
SHOULD BE PROTECTED W/ INTERRUPTOR CIRCUIT OF ARC. FAULT
REQ. AS PER N.E.0 210 -12
ALL 125 VOLT, 15 & 20 AMP. RECEPTACLES INSTALLED IN AREAS
SPECIFIED BY 210.12 SHALL BE LISTED TAMPER RESISTANT
DISC.
C- 2,4
F /W
I P
N
W
O
-A
11
w
oT_I- N
0) LO
Z M co p
-1 OI_
O! OZ0)
� � I
(n 0 a-- 0
� E I
0) o =
5i n
4z. 3 , •4.
o
LJJ
LL.
U
<
0
W
w
::E
Q
Ld
LLJ
0
ry
L�
N
Ln
LLJ
Z
V)
O
Ln
REMSIONI:
REVISION2
REMSION3
REMSION4
SHEET
E1