12-528-003LEGEND ELECTRICAL OUTLET -�- LIGHT RECEPTACLES 1 -WAY SWITCH ®D COMBO SMOKE /CARBON MONOXIDE DETECTOR ® ELECTRICAL OUTLET $3 3 -WAY SWITCH % E.F. EXHAUST FAN HI -HAT FLUORESCENT LIGTH ELECTRICAL PANEL ELECT. DISCONNECTOR FAN W/ LIGHT V PHONE TV CABLE GENERAL ELECTRICAL NOTES ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW BASE FLOOD ELEVATION SHALL BE INSTALLED AT THE HIGHEST PERMITTED ELEVATION AND SHALL BE INSTALLED ON (SEPARATE) INDEPENDENT CIRCUITS FROM THOSE IN THE HABITABLE AREAS. NO APPLIANCES OR APPLIANCE OUTLETS SHALL BE INSTALLED BELOW BASE FLOOD ELEVATION. - A/C COMPRESSOR SHALL BE INSTALLED ABOVE BASE FLOOD ELEVATION. - MAIN CIRCUIT BREAKER PANELS SHALLBE LOCATED ABOVE BASE FLOOD ELEVATION. - WE WILL CONFER WITH FLORIDA POWER & LIGHT TO LOCATE THE ELECTRIC METER TO COMPLY WITH FEDERAL EMERGENCY MANAGEMENT AGENCY REQUIREMENTS. ALL ELECTRICAL WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH LOCAL CODES AND ORDINANCE & ALL STANDARDS OF CONSTRUCTION ESTABLISHED BY THE LANDLORD. - ALL CONDUCTORS SHALL BE TWH OR THWN COPPER. ALL EXPOSED CONDUITS SHALL BE RUN AS NEAT AS POSSIBLE AND PAINTED TO MATCH COLOR OF SURROUNDINGS. P.V.C. CONDUIT SHALL ONLY BE USED IN SLAB OR UNDERGROUND AT A MINIMUM DEPTH OF 24 ". FLEXIABLE CONDUIT SHALL BE USED FOR CONNECTION TO ALL VIBRATING EQUIPMENT SUCH AS MOTORS, ETC. - ALL WIRING DEVICES SHALL BE LEVITON "DECORA" SERIES OR EQUAL AS APPROVED BY ARCHITECT OR ENGINEER. COLOR SELECTED BY ARCHITECT. - ALL RECEPTACLES SHALL BE INSTALLED AT 12 "A.F.F. UNLESS OTHERWISE NOTED. - ELECTRICAL POWER AND CONTROL WIRING FOR HVAC AND MECHANICAL EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. ELECTRICAL CONTRACTOR SHALL VERIFY THE CEILING FINISHES AND SUSPENSION SYSTEM FOR SELECTION OF THE PROPER TRIM AND SUPPORT ARRANGEMENT OF THE FIXTURE. - ELECTRICAL CONTRACTORS SHALL COORDINATE HIS WORK WITH THE ARCHITECT BEFORE ROUGH INSTALLATION OF LIGHTS, RECEPTACLES, SWITCHES AND EQUIPMENT FOR EXACT LOCATIONS. - ALL ELECTRICAL EQUIPMENT MUST BE U.L. APPROVED. luti :111 SWITCH LEG TO F.P.L P AS PER NEC 250.94 SMOKE DETECTOR SWITCH LINE SIDE 1 120 V OF SWITCH PHASE CONDUCTOR COMBO SMOKE DETECTOR O A NON/ SWITCHABLERLGHTING BE HARDWIRED (110 V TYPR) CONNECTION DETAIL NTS CIRCUIT WITH BATTERY BACK -UP AND SHALL NOT BE CONNECTED ONTO THE LOAD SIDE OF GROUND FAULT COMBO SD /CM DETECTOR CIRCUIT INTERRUPTER ALL SMOKE DETECTORS WITHIN EACH SHALL NOT BE PLACED UNIT SHALL BE INTERCONNECTED WITHIN 3 FT. OF ANY SO ALL DETECTORS SOUND WHEN ANY DETECTOR IS ACTIVATED A/C GRILL. AND COMPLY W/ N.E.0 210 -12 COMBO SD /CM DETECTOR SHALL BE INSTALLED WITHIN 3' OF ALL BEDROOMS 3 -1 /0 THW IN 2 " CONDUIT 50 A. O DI C.BRKR 0 00 GROUND ELECTRODE 1 # 6 THW CU TO FOUNDATION REBAR (AS PER N.E.C.) CWP & GAS PIPE ELECTRICAL RISER DIAGRAM 120/240V ELECTRIC PANEL A 150 AMPS. MCB 1 PH, 3W SURFACE MTD. CIRCUIT FUNCTION VOLTS C/B TRIP WIRE LOAD C- 1,3 STRIP HEATER /BLOWER #1 (7.5 KW) 240 2P -60 #6 7500 C- 2,4 A/C # 1 CONDENSING UNIT 240 2P -40 #8 (4000) C- 5 MICROWAVE 240 1P-20 #12 1500 C- 6 REFRIGERATOR 120 1 P -20 #12 1500 C -7 DISPOSAL 120 1 P -20 #12 1000 C -8 WASHER 120 1P-20 #12 1500 C- 9 DISHWASHER 120 1 P -20 12 1200 C -10,12 RANGE 240 2P -50 #6 12000 C -11 G.F.I. OUTLETS BATHROOMS 120 1P-20 #12 1500 C- 13,14,15 SMALL APPLIANCES 120 1 P -20 #12 4500 C -16,18 DRYER 240 2P -30 #10 5000 C -17,19 WATER HEATER 240 2P -50 #6 11000 C -20 -26 LIGHT & RECEPT. 120 1 P -15 #14 4515 C -27 -30 SPACES FLOOR AREA = 1505 S.F.® 3 WATTS = 4515 TOTAL LOAD = 55215 ELECTRICAL LOAD CALCULATIONS CONNECT LOAD LESS A/C = (55.2 -7.5) 47.7 KW 10 KW @100% = 10.0 KW 37.7 REST @ 40% = 15.08 KW A/C OHTNG 100% = 7.5 KW DEMAND LOAD = 32.6/240 = 136 AMPS. NOTE: ALL ELECTRICAL EQUIPMENT WIRING RATED ® 75"' C ELECTRICAL METER W/ MAIN DICONN. PANEL A WP C -16, C -20 GFI /WP b AC -20 ELECTRICAL PLAN SCALE 1/4"=l'-O" NOTE - ALL CIRCUITS WHO FEENDING ALL MONOFASICS OUTLET OF 125V & 15A & 20A , INSTALL IN ALL AREAS SHOULD BE PROTECTED W/ INTERRUPTOR CIRCUIT OF ARC. FAULT REQ. AS PER N.E.0 210 -12 ALL 125 VOLT, 15 & 20 AMP. RECEPTACLES INSTALLED IN AREAS SPECIFIED BY 210.12 SHALL BE LISTED TAMPER RESISTANT DISC. C- 2,4 F /W I P N W O -A 11 w oT_I- N 0) LO Z M co p -1 OI_ O! OZ0) � � I (n 0 a-- 0 � E I 0) o = 5i n 4z. 3 , •4. o LJJ LL. U < 0 W w ::E Q Ld LLJ 0 ry L� N Ln LLJ Z V) O Ln REMSIONI: REVISION2 REMSION3 REMSION4 SHEET E1