Loading...
12-528-002ROOF 1/2" GYPSUM BOARD METAL HEADER ON METAL STRIPS 0 16 "O.C. OR 2X4 WOOD HEADER 3 5/8 " -25GA. STUDS 0 16" O.C. 2 X 6 WD. BA 2X4 WOOD 0 16" 0/C FOR CAB. BACKIII ONE (1) LAYER 1/2" THK. GYPSUM BOARD EACH FACE OF STUD NAILED W/ 6d COOLER NAILS 0 7" O.C. FLOOR 2 X 4 WD. BA AT BOT. OF WALL METAL OR 2X4 WOOD CABINET AND AT BRACING 0 HUNG PLUMBING 5' -0" A.F.F. METAL RUNNER OR 2X4 PT WOOD RUNNER TYPICAL INTERIOR PARTITION NOT TO SCALE W U a V) " 6 EXISTING CONC.TIE BEAM •7, -fie ? .s.., .� ,�•,. �. •��'. ._ • � ,.F, ,..:11 1:�. i.''1.. •may.. •. 111. DRILL 3/4 "X6 1/2" HOLES TO RECEIVE # 55 BARS. FILL HOLES WITH SIKADUR -31 HI —MOD GEL EPDXY GRPUT OR EQUAL FOLLOW MRF INSTRUCTIONS PROVIDE MIN 6" EMBED (TYP. TOP & BOTTOM) 1 #5 IN CONC. FILLED CELL EXISTING CBS MAS. WALL HORIZONTAL JOINT REINFORCEMENT 0 16 "O.C. UP EVERY OTHER BLOCK COURSE 3FNIN #9 TRUSS TYPE TYP. '''X..- (ISTING• CONC. FOOTING'�"Y °^ DOWELL DRILL 3/4 "X6 1/2" HOLES TO RECEIVE # 5 2' -0" HORIZ. BARS. FILL HOLES WITH SIKADUR -31 HI —MOD GEL EPDXY GRPUT OR EQUAL FOLLOW MRF INSTRUCTIONS PROVIDE MIN 6" EMBED BLOCK UP OPENING DETAIL DOOR ROOM FINISH SCHEDULE ROOM FLOOR BASE WALLS CEILING CLG. HT. REMARKS BEDROOM TILE TILE GYP. BIRD. GYP. BIRD. HEIGHT THICK CLOSET TILE TILE GYP. BIRD. GYP. BIRD. PRE —HUNG WOOD BATH TILE — TILE GYP. BIRD. CLOSET 2' -4" LAUNDRY TILE TILE GYP. BIRD. I GYP. BIRD. WOOD INTERIOR PARTITION 3 -5/8" METAL STU 0 16" O.C. (TYP.)2 WOOD BACKING DETAIL NOTE AS PER F.B.C. Wall hung fixtures. Studs in bearing walls, exterior walls and non — bearing partitions supporting wall hung plumbing fixtures and wall cabinets shall be not less than 2x4, where spaced not more than 16 inches (406 mm) on center or, not less than 2x6, where spaced not more than 24 inches (610 mm) on center. A minimum 2x4 horizontal wood member, securely fastened to not less than two such studs, shall be installed for the attachment of each wall hung plumbing fixture and wall cabinet. NOTE AS PER FBC Bathrooms shall have a minimum ceiling height of 6 feet 8 inches (2036 mm) over the fixture and at the front clearance area for fixtures A shower or tub equipped with a showerhead shall have a minimum ceiling height of 6 feet 8 inches (2036 mm) above a minimum area 30 inches (762 mm) by 30 inches (762 mm) at the showerhead. NOTE AS PER FBC Termite pprotection. All builld {ings shall have pre—construction �� er'ja r�s�fdp�otet to �lor��a Dena to en�eo{' At nc �I ure an c psume Services �Emplprice a� 6e d eie� asp rove ith r spec �o re- onsr con , od ment or o{ectff a ams su b folwi rgnean tper�mfe.. ert�f�cate of sh9[ pe issue to �ie u+ inR depq men by t e icensed pest canta company at con ains e o g s a ement: "Thi0bui diinn� as ,rteceive�l a corr�plet� treatme 9 for tie geventio of su ne ermi r tmen is in a cords ce wi es an laws es a is y the orida epartment of cdgncu ure an nsumer Services. NOTE 1 SHOWER ENCLOSURE SAFETY GLASS CAT.2 400 # IMPACT TEST NOTE 2 TILE IMPERVIOUS FINISH UP TO 80" A.F.F. ON DUROCK CEMENT BOARD 1/2" MEAN OF ESCAPE NOTE: ALL EGRESS WINDOWS TO COMPLY W/ F.B.C. AN OUTSIDE WINDOW OR DOOR OPERABLE FROM THE INSIDE WITHOUT THE USE OF TOOLS AND PROVIDING A CLEAR OPENING OF NOT LESS THAN 20" WIDEX24" HIGH AND 5.7 S.Q FT. IN AREA THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44 OFF THE FLOOR, THE MODE OF OPERATION MUST NOT REQUIRE THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE OR EFFORT TO MAKE AVAILABLE THE REQUIRED CLEAR OPENING, AND NO PART OF THE OPERATION MECHANISM SHALL BE PLACED HIGHER THAN 54" ABOVE THE FINISHED FLOOR EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM INSIDE THE CLOSET EVERY BATHROOM DOOR SHALL BE DESIGNED TO ALLOW OPENING FROM THE OUSIDE DURING AN EMERGENCY WHEN LOCKED DOOR SCHEDULE NO. LOCATION SIZE TYPE MATERIAL FINISH THRESHOLD JAMB REMARKS WIDTH HEIGHT THICK 1 BATH /BEDROOM 2' -8" 6' -8" 1 3/4" PRE —HUNG WOOD WOOD 2 CLOSET 2' -4" 6' -8" 1 3/4" BI —FOLD WOOD WOOD FULLY LOUVERED O3 CLOSET 8' -0" 6' -8" 1 3/4" BI —FOLD WOOD WOOD FULLY LOUVERED O4 CLOSET 3' -0" 6' -8" 1 3/4" BI —FOLD WOOD WOOD FULLY LOUVERED GROUND FLOOR PLAN 1 /4 "=1' -0" UP OPENING DETAIL CITY OF SOUTH NAIIIANI) BUILDING DEPT. STRUCTURAL 'zFCTION ',,,'T:` )VED 9Y Q n N W n 0 1 "W ,1'<r nJ '' C; O LL. Z LLI O LLJ Of 0 LLI I-- Z O ur) (0 0 I� N O PC) 0) V7 (0 O J 0 r� 0Z0) Uj :2 1 (n 000 E I � o = J LL Q W � U Lj zQ LLJ W � U) N W 3�: ry co O Ln L0 O REVISIONI MOM REVISION3 REVISION4 SHEET A2