Loading...
12-570-004MECHANICAL NOTE-. I.INSTALL NEW A/C UNIT AS NOTED SEE DETAIL 71SOMODE THIS SHEET 4' HIGH PAD 1 15 CONT. CONC, PAD UNDER UNIT T14&SS COATED CABLE ORED TO 4' CONC. SLAB .r: •:t.'•:i:� � ter' "'° NO CU -1 FOR CONT.- ROOF TRUSS SPACE SEE PLAN FIRE DAMPER (S) AHU -1 PER FMC SEC 603.1.3 REQUIRES ,"� • . ,... 4 AHU CLOSETS TO BE PROVIDED W/ 2" FOAM SEAL � .; is NOTE: FASTEN HOLD DOWN STRAPS TO C.U. do CONC. PAD TO ,,,� ,.,� WITHSTAND HURRICANE FORCE WINDS OF 146 MPH TEK 16 GA. x 1 -1/4 GALV. UNIT STRAP UNIT . -GONG. SLAB 1/2' HILTI SLEEVE 'a'�iQ'/t?�" �.• ANCHOR, MIN. 2-1 PENETRATION (4 .) MASON INDUSTRIES 2' x 2' x 3/4' SUPER 'W' PAD TYP. EACH CORNER CONDEN. UNIT MOUNTING DETAIL N.T.S. 22 511 —4' CONC. SLAB SUPPLY AIR PLENUM W/ R -6 INSULATION RECTANGULAR DUCTS W/ R -6 INSULATION RS &RL PIPING TO NO CU -1 FOR CONT.- ROOF TRUSS SPACE SEE PLAN FIRE DAMPER (S) AHU -1 PER FMC SEC 603.1.3 REQUIRES UNIT TIGHT TO PLENUM 4 AHU CLOSETS TO BE PROVIDED W/ 2" FOAM SEAL ( .) A MIN. 4" CLEARANCE ON ALL 33,000 CLOSET SIDES OF A.H.U. R -4.2 INTERNAL PARTITION INSULATION 3/4" SAFE -T- SWITCH (AUXILLARY FLOAT SWITCH) 13.0 MFR. SMD RESEARCH, INC., BOCA RATON, FL AIR HANDING MODEL NUMBER SS2 AS PER FMC SEC.307.2.3 UNIT CIRCUIT BKR. MAX. AMPERES 40/40 Ire"" FILTER HEIGHT TO BE 1 -1/2" x 1 -1/2" x 1/4" DETERMINED 3/4" C. D.- ANGLE ALUMINUM SUPPORT AT JOB SITE STAND CLOSET FLOOR CD. PUMP 3/4' C.D. ABOVE CONC. SLAB NOTE: DETAIL IS DIAGRAMMATIC, SEE PLAN FOR CORRECT ORIENTATION OF DUCTS, RS & RL PIPING A.H. UNIT MOUNTING DETAIL N.T.S. 24 SIi � 24 511 :r CO. TO OUTSIDE, DISCHARGE 6' ABG. & EXTEND 12' AWAY FROM BLDG. MECHANICAL PLAN 1/4 to= i ' — 0" 0�, HVAC DESIGN CHART HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR (S) UNIT NOMINAL CAP. (TONS) X FIRE DAMPER (S) AHU -1 X FIRE RATED ENCLOSURE MODEL NUMBER X FIRE RATED ROOF /FLOOR 33,000 X FIRE RATED CEILING ASSEMBLY AMBIENT TEMPERATURE X FIRE STOPPING 13.0 X PVC CAP WITH 1/8" DIA. HOLE DRILLED ON TOP FOR VENT PVC SCH. 40 PIPING 1-1/2" 3" mm_ cim 3/4" CONDENSATE DRAIN PIPE ABOVE FLOOR SLAB FOR CONT. SEE PLAN, THIS DRAWING z x N A.H.U. CONDENSATE DRAIN PIPING DETAIL LOW VELOCITY SUPPLY AIR PLENUM R -6 INSULATION SEAL DUCT JOINT WITH DUCT SEALER & TAPE INSULATED FLEX DUCT R -6 INSULATION SEAL DUCT JOINT WITH DIFFUSER DUCT SEALER & TAPE FLEXIBLE DUCT CONNECTION DETAL N.T.S. A/C GENERAL NOTES: - 1. THE WORK THAT IS TO BE DONE UNDER THIS HEADING INCLUDES, THE -' FURNISHING OF ALL LABOR, MATERIALS, EQUIPMENT, PERMITS, FEES- _ INSPECTIONS, TESTS, INSURANCE, ETC. REQUIRED FOR THE ------ - _ - - - COMPLETION OF THE AIR CONDITIONING SYSTEM SHOWN ON THE DRAWINGS AND /OR LISTED BELOW. 2. VENTILATION DUCTWORK SHALL BE GALVANIZED STEEL WITH GAUGES, DUCT CONSTRUCTION, BRACING AND SUSPENSION IN ACCORDANCE WITH THE RECOMMENDATIONS SET FORTH IN THE LATEST EDITION OF THE A.S.H.R.A.E. GUIDE AND S.M.A.C.N.A. STANDARDS. DUCT SIZES SHOWN ARE "INSIDE" DIMENSIONS. VERIFY EXACT LOCATION OF DUCT WITH RESPECT TO STRUCTURE BEFORE FABRICATION. 3. FLEXIBLE DUCT SHALL BE STEEL HEUX WIRE ON 7/8" CENTERS, ENCAPSULATED IN A CONTINUOUS SOFT VINYL FILM, JOINED BY MOLECULAR WELDING TO FORM AN AIR TIGHT INNER CORE. THE CORE IS TO BE INSULATED WITH FIBERGLASS INSULATION (R -6), AND SHEATHED IN A REINFORCED, ALUMINUM METALIZED POLYESTER VAPOR BARRIER JACKET. PROVIDE SPIN COLLAR WITH DAMPER AND EXTRACTOR WHERE FLEXIBLE DUCT IS CONNECTED TO RECTANGULAR DUCTWORK. DAMPER ACTUATOR SHALL BE EXTENDED OUTSIDE INSULATION. 4. AIR CONDITIONING SUPPLY AND RETURN DUCTWORK SHALL BE 1 -1/2" (R -6 MIN.) FIBERGLASS U.L. 181 LISTED, CLASS I AIR DUCT. DUCTWORK SHALL BE FABRICATED IN ACCORDANCE WITH S.M.A.C.N.A. STANDARDS. (R -6 TOP LEVEL. R -4.2 IN OTHER LEVELS). 5. TEMPERATURE CONTROL SHALL BE A ROOM THERMOSTAT FOR HEATING / COOLING WITH STAGES AS REQUIRED. 6. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION AND IN STRICT COMPLIANCE WITH ALL APPLICABLE CODES AND STANDARDS. 7. MECHANICAL CONTRACTOR SHALL VERIFY DIRECTION OF EXISTING STRUCTURE BEFORE INSTALLATION OF EQUIPMENT AND DUCTWORK. SHOULD ANY DISCREPANCIES BE FOUND CONTACT ARCHITECT /ENGINEER. 8. VIBRATION ISOLATION: ALL EQUIPMENT AS PER MANUFACTURER RECOMMENDATIONS TO ELIMINATE ANY EQUIPMENT NOISE FROM BEING HEARD. 9. GUARANTEES: A. ALL COMPRESSOR MOTORS ON NEW EQUIPMENT FURNISHED UNDER THIS CONTRACT SHALL HAVE A 5 YEARS PRODUCT GUARANTEE FROM DATE OF START -UP. B. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN 1 YEAR FROM DATE OF ACCEPTANCE. 10. TESTING: A. ALL REFRIGERANT HIGH SIDE PIPING TO BE 300 PSIG. LOW SIDE TO 150 PSIG. AFTER TESTING, EVACUATE SYSTEM TO 28% MERCURY GAUGE PRESSURE WITH VACUUM PUMP. HOLD FOR 25 HOURS WITH PUMP OFF. BREAK VACUUM WITH REFRIGERANT. B. BALANCE AIR SYSTEM TO DELIVER QUANTITIES AT EACH OUTLET WITHIN 5% USING A.A.B.C. PROCEDURES AND TESTS. SUBMIT AIR BALANCE TEST RESULTS FOR APPROVAL PRIOR TO FINAL INSPECTION. 11. REFRIGERATION SUCTION PIPING SHALL BE INSULATED WITH 3/4" IN- COAFLEX. ARMAFLEX INSULATION MAY ONLY BE USED IN NON- PLENUM AREAS. FINISHED WHERE EXPOSED WITH 2 COATS OF WHITE LATEX PAINT AS PER MANUFACTURER'S INSTRUCTION. 12. ALL REFRIGERANT PIPING SHALL BE TYPE "K" HARD COPPER, TOGETHER WITH WROUGHT COPPER SOLDER FITTINGS. JOINTS SHALL BE MADE WITH SILVER SOLDER OR "SILFOS ". ALL CONDENSATE DRAIN PIPING TO BE SCHEDULE 40 TYPE II HIGH IMPACT PVC WITH SLIP JOINT FITTING OF THE SAME MATERIALS WITH AN APPROVED SOLVENT INSTALLED IN A MANNER RECOMMENDED BY THE FITTING MANUFACTURER. 13. ALL WORK SHALL CONFORM WITH THE MECH. BLDG. CODE 2001, 2002 REVISIONS. AND ALL OTHER APPLICABLE STATE AND LOCAL REGULATIONS AND ORDINANCES. N.T.S. CONDENSING UNIT SCHEDULE (NEW) UNIT L ❑CATION OUTSIDE UNIT WEIGHT (LBS.) 227 UNIT NOMINAL CAP. (TONS) 3 MATCHING AHU NUMBER AHU -1 MANUFACTURER GOODMAN MODEL NUMBER VSX130361D TOTAL C❑ ❑LING CAP. (BTUH) 33,000 TOTAL SENSIBLE CAP. (BTHU) - AMBIENT TEMPERATURE 95' UNIT MIN. SEER 13.0 AVAILABLE VOLTAGE 208/230/1 -60 CIRCUIT BKR. MIN, AMPERES 25/25 CIRCUIT BKR. MAX. AMPERES 40/40 SUCTI ❑N LINE DIAM. 1 1/8' LIQUID LINE DIAM. 5/16' CALCULED TOT. COOLING CAP, - AIR HANDLING UNIT SCHEDULE (NEW) UNIT NUMBER A.H.U. -1 MATCHING CONDENSING UNIT CU -1 MANUFACTURER GOODMAN MODEL NUMBER ARUF3616CA UNIT L❑CATI ❑N CLOSET UNIT TYPE VERTICAL ENTERING AIR TEMP. (db /wb) 80'/67' EXTERNAL STATIC PRESS. 0.30 FAN MOTOR 1/3 AVAILABLE VOLTAGE 208/240 -1 -60 NUMBER OF STEPS 1 FILTER TYPE PERMANENT CFM 1200 HEAT (kw) 6.0 2 240V w � J Li U cn Lli J Q U = a W UJ Z rn O J LL_ p J o z � o Ln � CD Io %_o 0 Z Ld J U � 5; C) N r4t: O Z U Lu � ' uj DATE'" 21 MAY 2012 O Q N I Q Q = LL_ CD I— L0 Q W 3 cf) 0 I— Ln O C-0 cf) 0 Q M -1 w