13-1254-009SITE INVESTIGATION NOTE SITE VISIT PRIOR TO BID EXAMINATION OF CONTRACT DOCUMENTS AND SITE: THE BIDDER IS REQUIRED BEFORE SUBMITTING HIS /HER PROPOSAL, TO VISIT THE SITE AND FAMILIARIZE HIMSELF /HERSELF WITH THE NATURE AND EXTENT OF THE WORK TO BE PERFORM. ANY DEVIATIONS THAT MAY AFFECT THE WORK TO BE PERFORMED, SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT /ENGINEER FOR CONSIDERATION, PRIOR TO SUBMITTING OF BID. VARIATIONS FROM CONTRACT DOCUMENTS ROUTING AND /OR CONSTRUCTIONS DEVIATIONS SHALL BE ANTICIPATED BY THE CONTRACTOR TO AVOID CONFLICTS WITH OTHER TRADES. THESE DEVIATIONS ARE EXPRESSLY INCLUDED AS PART OF THE WORK TO BE PERFORMED WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER. THE CONTRACTOR WILL IN NO WAY BE RELIEVED OF HIS /HER OBLIGATIONS AND RESPONSIBILITIES ASSUMED UNDER THIS CONTRACT. CONSIDERATION WILL BE GIVEN TO UNFORESEEN CONDITIONS. NOTE TO BUILDER TO THE BEST OF OUR KNOWLEDG=E AND BELIEF, THE INFORMATION CONTAINED ON THESE DRAWINGS CONFORMS TO THE STANDARDS SET IN THE FLORIDA BUILDING CODE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL DIMENSIONS, AND FIELD CONDITIONS PRIOR TO THE START OF THE WORK, AND NOTIFYING THE ENGINEER, AT ONCE, OF ANY AND ALL ERRORS, DISCREPANCIES, IRREGULARITIES, OR OMISSIONS PERTAINING TO THE SUCCESSFUL COMPLETION OF THE PROJECT INDICATED. LOW VELOCITY — SUPPLY AIR DUCT (SEE PLAN VIEW) INSUL R -6 METAL ROUND FITTING QUADRANT OPERATOR TO BE OUTSIDE INSULATION PROVIDE INSULATION GUARD WHERE NECESSARY I SULATED FLEX. DUCT. IVz' F /G,WITH POLYETHELENE JACKETAND STEEL WIRE REINFORCING(R -6) SEAL JOINT WITH EPDXY t DUCT T AIR FLOW PERFORATED DIFFUSER AIR FLOW SEAL JOINT WITH EPDXY t DUCT TAPE T"r=ICAL DIEEUSEIR CONNECTION DETAIL NO SCALE PIPE INSULA REFRIGERA1 TO AIR HANv!_MK THRU CEILING SPACE CONDENSING; UNIT A�4U#2 43 IN5TAL,L =ATION DETAIL, NO SCALE ONDENSING 4IT FIELD COORDINATION NOTES 1- EVERY CONTRACTOR SHALL COORDINATE IN FIELD W/ OTHER TRADES PRIOR START OF CONSTRUCTION FOR THE STRUCTURAL BEAM, SLAB, TRUSSES, ARCHITECTURAL DETAILING AS PRE -FAB FORMS, REVELING, CEILINGS, ARCH WITH THE LOCATION OF CEILING OR WALL GRILLES, DUCT WORKS, RETURN GRILLES, LIGHTING FIXTURES, SWITCHES, RECEPTACLES OR ANY OTHER DEVICES. AND TO NOTIFY ARCHITECT/ ENGINEERS IF ANY CONFLICT OCCUR PRIOR ITS INSTALLATION, NO ADDITIONAL COST TO OWNER CAN BE APPLIED. 2- THE COMPLETE SET OF CONSTRUCTION DOCUMENTS CONSISTS OF DRAWINGS, DETAILS AND SPECIFICATIONS. IN THE EVENT OF DISCREPANCIES, THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT AND /OR ENGINEERS FOR CLARIFICATIONS. ANY DEVIATION FROM THESE DRAWINGS, WITHOUT THE WRITTEN AUTHORIZATION OF THE ARCHITECT AND /OR ENGINEERS IS PROHIBITED. GENERAL CONTRACTOR OR SUBCONTRACTORS ASSUME FULL RESPONSABILITY FOR ANY UNAUTHORIZED DEVIATION FROM THE INFORMATION DEPICTED IN THE CONSTRUCTION DOCUMENTS. ENGINEERS ARE NOT RESPONSIBLE OR LIABLE FOR ANY DISCREPANCY BETWEEN THESE DRAWINGS AND THE EXISTING CONDITIONS. ANY WORK PERFORMED ON THE PROPERTY PRIOR THESE CONSTRUCTION DOCUMENTS AND WILL NOT MATCH WITH THE INFORMATION IN THE EXISTING CONSTRUCTION DOCUMENTS ON CITY RECORDS OR IT WAS NOT VISIBLE AT TIME OF INSPECTION OR THE WORK WAS DONE ILLEGALLY WITHOUT PERMIT BY OTHERS AND WILL CAUSE A DISCREPANCY WITH THE NEW DRAWINGS IS THE RESPONSABILITY OF THE CURRENT OWNER OF THE PROPERTY AT HIS OWN EXPENSE TO PERFORM ALL NECESSARY CORRECTIONS IN ORDER THAT THE ALL WORK IS IN ACCORDANCE WITH THE CURRENT FLORIDA BUILDING CODE AND THE LOCAL ORDINANCE AND WILL MATCH WITH THE NEW CONSTRUCTION DOCUMENTS FOR NEW WORK WHICH WILL BE PERFORMED. 3- IT IS REQUIRED THAT THE MECHANICAL CONTRACTOR OR HIS REPRESENTATIVE MUST VISIT THE JOBSITE TO FAMILIARIZE AND VERIFY DIMENSIONS AND ANY MAJOR ITEMS SUCH AS THE STRUCTURAL ELEMENTS, HVAC ITEMS LOCATIONS OR PROVISIONS, ELECTRICAL RUNS, PLUMBING AND MISCELLANEOUS ITEMS NOT COVERED BY THESE DRAWINGS PRIOR TO BIDDING OR ANY WORK. * *(THIS SHALL BE THE RESPONSIBILITY AND SOLE EXPENSE OF THE MECHANICAL CONTRACTOR.) ** ONCRETE AD SHALL BE OT LESS THAN " THICK. S' ABOVE _OOD LEVEL R /A DUCT WHEN APPLY REFRIGERANT LINES) TO OUTSIDE CONDEN51NG UNIT THRU ATTIC SPACE 3/4' CONDENSATE DRAIN w/ 3' TRAP UNION AND C.O TO GREEN AREA GsALV. STEEL A.N.U. SUPPORT (SELF - STANDING) NO COMBUSTIBLE MATERIALS WITHIN A.H.U. ROOM R/A THRU LOUVER DOOR �► WHEN APPLY 0"11% HOR W/POWER DRIVEN STUDS OR 3/8'X1.5 "LG - TAP -CONS, OR LAG BOLTS W/ SHIELDS INSIDE G.U. THRU BASE PLATE TO WITHSTAND WINDS OVER 1 "I6 MPH WITH AN ANCHOR BOLT OF 500 POUNDS MIN. PULL OUT CAPACITY. IT, Y DUCT [LING NOTE: PROVIDE VOLUME DAMPERS BETWEEN RIGID AND FLEXIBLE DUCTS. SEE DETAIL. OR AT AC DIFFUSER. MECHANICAL ATTACH PLENUMS AND RETURN W/FLEXIBLE CONN. °ART I T ION PERFORATED CAP FOR VENT, 12' HIGH -----FLOAT SWITCH TO SHUT DOWN A/C UNIT AS PER SECTION 30 -12.4 OF FBC \ I \—PROVIDE 4' CLEARANCE I ALL AROUND A.H.U_ AND THE A/C CLOSET SHALL HAVE A TOTAL WITH OF AT LEAST 12' WIDER THAN THE A.H.U. `N C.D. UDE NDERSLAB TO COMPLY WITH FBC (PLUMBING) SECTION 1103 Alit HANDLER UNIT#2 43 INSTALLATION DETAIL NO SCALE OVIDE WIRE MESH D SHALL 5E CORROSION S I STANT AS PER F.B.C. 401.5 AIR FLOW S/M 26 G. SIZE \—DEPEND OF TYPE OF FAN BEE FAN SCHEDULE. EXHAUST DUCT-/ EXHAUST rAN 4 DUCT - DETAIL N.T.S. K. HOOD*1 UP THRU ROOF W /GAP, FILTERS, I0'4 26 G S/M DUCT PROVIDE WITH B WMESFAMRDIIREE H FOR BIRDS PROTECTION d SHALL BE CORROSION RESISTAS N F L= 1I� IL== /=A I N 7FSCALE: 1 /4 "=1' -m" S& ^HISTORY OF DRAWING ISSUED ^ ^ DESCRIPTION DATE OF ISSUED Q PRJGREGS SCALE ^ ^^ Q PCRMIT ^ - ^ ^ - - CCNSTZJCTION ^ ^ ^ REVISION BY^ ^ ^ ^ O LL z p N� W LL 0 � � Y 0 w V -� Z fv N LLu W o �- L, 0 CD O w CL co M � cj CD Z M o z U- U z Q Q � J G CN to Nto j O W W M D � LL U w o Lo Q co W M co _ � o z 0 w V)R °) Q �^ CLa%j p �. / _ LLI Qr ` J m c) ti DATE 09 -09 -13 SCALE AS NOTED DRAWING Y.T. JOB SHEET OF M _ SHEETS y�1 14