DOOR TYPES
SCALE: 3/8 " =1' -0"
5"
2' -6" 2' -6"
0
9.
4
D
rel
00
1
CD
t__ 2'--j
O
7
I
a
®— 8' I
00■ 0■
a
4
1
c0
ME
WINDOWS TYPES
SCALE: 3/8 " =V-0"
1)A22 4M=11 PM. FP Dedp3d I M by HP, Arch D - 24 x 36 h ) .
FINISH NOTES �
R315.1 Wall and ceaTng.
Wall and ceiling finishes shall have a flame — spread classification of not greater than 200.
Exception: name— spread requirements for finishes shall not apply to trim defined as picture
molds. chair rails, baseboards and hondrals; to doors and windows or their frames; or to
materials that a re less than 1 / 28 inch (0.907 mm) in thickness cemented to the surface
of walls or ceTings 9 these materials have a flame — spread characteristic no greater than
paper of this thickness cemented to a noncombustible bocidng.
R315.2 Smoke — developed index.
Wall and ceiling finishes shall have a smoke— developed index of not greater than 450.
r I of r
WINDOW AND DOOR ASSEMBLIES AND THEIR INSTALLATION SHALL BE IN
ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AS SET FORTH
IN APPROVED PRODUCT CONTROL SUBMITTALS PER THE F.B.C.
ALL FIXED GLASS PANELS SHALL BE 3/16' OR THICKER AS REQ. TO MEET
WIND LOADS AND IMPACT REQUIREMENTS, SAFETY GLASS. ALL GLASS USED
INSIDE OF DWELLING TO BE TEMPERED, TO COMPLY WITH THE F.B.C.
EGRESS TYPE WINDOWS MALL BE OPERABLE FROM THE INSIDE WITHOUT
THE USE OF KEY, TOOL, OR SPECIAL KNOWLEDGE OR EFFORT, AND SHALL
PROVIDE A CLEAR OPENING OF NOT LESS THAN 20" WIDE, 24' HIGH, AND
5.7 FEET IN AREA. THE BOTTOM OF THE OPENING SHALL NOT BE MORE
THAN 44' ABOVE THE FLOOR, AND NO PART OF THE MECHANISM SHALL
BE PLACED HIGHER THAN 54' ABOVE THE FLOOR.
PROVIDE HURRICANE SHUTTERS APPROVED BY COUNTY PRODUCTS
CONTROL AT ALL REQUIRED DOOR AND WINDOW OPENINGS
WITH NON — IMPACT WINDOWS.
PROVIDE OPAQUE GLASS AT BATHROOM WINDOW AS PER F.B.C.
PROVIDE SAFETY TEMPERED GLASS AS PER F.B.C. FOR WINDOW
AND SHOWER ENCLOSURE.
Contractor shall verify with window and doors manufacturers
required masonry opening for proper installation before concrete
block work is started or tie columns are poured.
CAT. II SAFETY GLASS SHALL BE USED AT ALL SHOWER
AND TUB ENCLOSURES INCLUDING WINDOWS WITH SILLS
LOWER THAN 60" AND MIRRORS IN THE TUB.
ALSO, IT SHALL BE USED ON OPENINGS WITHIN 12'
OF DOORS.
ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE
OF 300 LB. APPLIED IN ANY MOVABLE DIRECTION IN ACCORDANCE WITH
RESISTANCE STANDARDS SET FORTH IN F.B.C.
PANELS.
FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR SCOPE
OR VISION
DOORS MID WINDOWS
SUBMIT SHOP DWG's FOR APPROVALS IN SEPARATE PERMIT
F'31 1111112F.4 r . ti. r 1 . �, • �• 1
NOTE
ALL NEW ENDOWS TO BE PROVIDED W/ MIAMI—DADE
APPROVED
ALL SHUTTERS TO BE DESIGNED BY A QUALIFIED
REGISTERED DELEGATE ENGINEER FOLLOWNG
PROCEDURES # FORTH
OF : C. RESIDENTIAL 2007 E1
NOTE:
COORDINATE ALL MASONRY OPENINGS FOR WINDOWS do
DOORS WITH WINDOWS & DOOR MANUFACTURER PRIOR
TO TIE BEAM AND BLOCK ERECTION.
CEILING AS PER R315.1 FBC—RESIDENTIAL 2007 WALL MD
#
CLASSIFICATION OF + GREATER THAN 200
BURGLARY
NOTES:
r• aI• �r • 1 a s' 1 • f . I t#
•r'r « r +• f« r f
a
1 1 #11` "1 11r •#
:1 + • t • s• x r r 1.. # ti
. #_s.
•s r
f a• r• / � 1r#.
•• a r> r � r r�
D T r• ►11- i �- !
If• r r +11' #
1, ► , y1 � 1 • F
.« .2.
1 • �2' 1 • 1 1
�• f• # ##
# •f
«r • • #
/« • a �• r• 1rr•
1• •f fr / 1.11• # f#
I I I
I i
1.. L G
architecture
P l a n n i n g
interior design
AA 260007711
1B 26Q006W
250 Catalonia, suite 403
coral gables, florida 33134
telephone : 305 .567. 1977
facsimile : 305.567. 1125
LLj
DRAWN BY.
DOOR SCHEDULE
CHECKED BY:
P.B.
DATE:
05 -13.10
A
I■
SIZE
SUBMITTAL SCHEMATIC DESIGN
i
i
NO.
LOCATION
ii
I1 SAFETY GL
TYPE
MATERIAL
FINISH
THRESHOLD
JAMB
REMARKS
•
W
1
ENTRY
•_
OIL
3' -0"
6' -8R
1 3/4'
RAISED PANEL
METAL
PAINTED
FLUSH
METAL
MTL THRESHOLD. WEATHER STRIP,
DOOR SCOPE, SEE FINISH NOTES
2
GARAGE
3' -0"
6' -8'
1 3/4"
SOLID CORE
METAL
PAINTED
PAINTED
SEE FINISH NOTES
3
CABANA BATH
2' -4"
6' -8'
1 3/8"
PRE —HUNG
ALUM /GLASS
ALUM
SEE FINISH NOTES
4
COVERED TERRACE
(2)2' -6"
6' -8'
1 3/8"
PRE —HUNG
ALUM /GLASS
ALUM
SEE FINISH NOTES
5
DINING ROOM
(3)3' -0'
6' -8'
1 3/8'
SLINDING
ALUM /GLASS
ALUM
SEE FINISH NOTES
6
GARAGE
3' -0"
6' -8'
1 3/4'
SOLID CORE
METAL
PAINTED
PAINTED
MTL THRESHOLD, AUTO CLOSE,
SEE FINISH NOTES
7
MASTER BEDROOM
2' -6"
6' -8"
1 3/8"
PRE —HUNG
WOOD
WOOD
MARBLE SADDLE AT BATHROOMS
MASTER W.I.0
ONLY, SEE FINISH NOTES
MASTER BATH
SUITS CLOSET
8
WATER CLOSET
2' -0'
6' -8'
1 3/8'
PRE —HUNG
WOOD
WOOD
MARBLE SADDLE AT BATHROOMS
ONLY, SEE FINISH NOTES
9
A/C CLOSET
2' -6"
6' -8'
1 3/8"
PRE —HUNG
WOOD
WOOD
FULL LOUVERED
10
GARAGE
8' -0"
6' -100
1 3/4'
O.H. GARAGE
METAL
PAINTED
METAL
RAINCUT THRESHOLD
NOTES:
1.— COORDINATE MASONRY OPENING W/ DOOR MANUFACTURER PRIOR TO WALL ERECTION (SUBMIT SHOP DRAWINGD FOR APPROVAL)
2.— ALL EXTERIOR DOORS TO RECEIVE SILL
TO MATCH FLOOR FINISH.
* DOOR FRAME SHALL BE SOLID 2 x 4
RABBETED WOOD FRAME
FINISH NOTES �
R315.1 Wall and ceaTng.
Wall and ceiling finishes shall have a flame — spread classification of not greater than 200.
Exception: name— spread requirements for finishes shall not apply to trim defined as picture
molds. chair rails, baseboards and hondrals; to doors and windows or their frames; or to
materials that a re less than 1 / 28 inch (0.907 mm) in thickness cemented to the surface
of walls or ceTings 9 these materials have a flame — spread characteristic no greater than
paper of this thickness cemented to a noncombustible bocidng.
R315.2 Smoke — developed index.
Wall and ceiling finishes shall have a smoke— developed index of not greater than 450.
r I of r
WINDOW AND DOOR ASSEMBLIES AND THEIR INSTALLATION SHALL BE IN
ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AS SET FORTH
IN APPROVED PRODUCT CONTROL SUBMITTALS PER THE F.B.C.
ALL FIXED GLASS PANELS SHALL BE 3/16' OR THICKER AS REQ. TO MEET
WIND LOADS AND IMPACT REQUIREMENTS, SAFETY GLASS. ALL GLASS USED
INSIDE OF DWELLING TO BE TEMPERED, TO COMPLY WITH THE F.B.C.
EGRESS TYPE WINDOWS MALL BE OPERABLE FROM THE INSIDE WITHOUT
THE USE OF KEY, TOOL, OR SPECIAL KNOWLEDGE OR EFFORT, AND SHALL
PROVIDE A CLEAR OPENING OF NOT LESS THAN 20" WIDE, 24' HIGH, AND
5.7 FEET IN AREA. THE BOTTOM OF THE OPENING SHALL NOT BE MORE
THAN 44' ABOVE THE FLOOR, AND NO PART OF THE MECHANISM SHALL
BE PLACED HIGHER THAN 54' ABOVE THE FLOOR.
PROVIDE HURRICANE SHUTTERS APPROVED BY COUNTY PRODUCTS
CONTROL AT ALL REQUIRED DOOR AND WINDOW OPENINGS
WITH NON — IMPACT WINDOWS.
PROVIDE OPAQUE GLASS AT BATHROOM WINDOW AS PER F.B.C.
PROVIDE SAFETY TEMPERED GLASS AS PER F.B.C. FOR WINDOW
AND SHOWER ENCLOSURE.
Contractor shall verify with window and doors manufacturers
required masonry opening for proper installation before concrete
block work is started or tie columns are poured.
CAT. II SAFETY GLASS SHALL BE USED AT ALL SHOWER
AND TUB ENCLOSURES INCLUDING WINDOWS WITH SILLS
LOWER THAN 60" AND MIRRORS IN THE TUB.
ALSO, IT SHALL BE USED ON OPENINGS WITHIN 12'
OF DOORS.
ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE
OF 300 LB. APPLIED IN ANY MOVABLE DIRECTION IN ACCORDANCE WITH
RESISTANCE STANDARDS SET FORTH IN F.B.C.
PANELS.
FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR SCOPE
OR VISION
DOORS MID WINDOWS
SUBMIT SHOP DWG's FOR APPROVALS IN SEPARATE PERMIT
F'31 1111112F.4 r . ti. r 1 . �, • �• 1
NOTE
ALL NEW ENDOWS TO BE PROVIDED W/ MIAMI—DADE
APPROVED
ALL SHUTTERS TO BE DESIGNED BY A QUALIFIED
REGISTERED DELEGATE ENGINEER FOLLOWNG
PROCEDURES # FORTH
OF : C. RESIDENTIAL 2007 E1
NOTE:
COORDINATE ALL MASONRY OPENINGS FOR WINDOWS do
DOORS WITH WINDOWS & DOOR MANUFACTURER PRIOR
TO TIE BEAM AND BLOCK ERECTION.
CEILING AS PER R315.1 FBC—RESIDENTIAL 2007 WALL MD
#
CLASSIFICATION OF + GREATER THAN 200
BURGLARY
NOTES:
r• aI• �r • 1 a s' 1 • f . I t#
•r'r « r +• f« r f
a
1 1 #11` "1 11r •#
:1 + • t • s• x r r 1.. # ti
. #_s.
•s r
f a• r• / � 1r#.
•• a r> r � r r�
D T r• ►11- i �- !
If• r r +11' #
1, ► , y1 � 1 • F
.« .2.
1 • �2' 1 • 1 1
�• f• # ##
# •f
«r • • #
/« • a �• r• 1rr•
1• •f fr / 1.11• # f#
I I I
I i
1.. L G
architecture
P l a n n i n g
interior design
AA 260007711
1B 26Q006W
250 Catalonia, suite 403
coral gables, florida 33134
telephone : 305 .567. 1977
facsimile : 305.567. 1125
LLj
DRAWN BY.
A.P.
CHECKED BY:
P.B.
DATE:
05 -13.10
A
I■
,
SUBMITTAL SCHEMATIC DESIGN
i
i
ii
I1 SAFETY GL
iii
�
�
•
•_
OIL
`#
•
FINISH NOTES �
R315.1 Wall and ceaTng.
Wall and ceiling finishes shall have a flame — spread classification of not greater than 200.
Exception: name— spread requirements for finishes shall not apply to trim defined as picture
molds. chair rails, baseboards and hondrals; to doors and windows or their frames; or to
materials that a re less than 1 / 28 inch (0.907 mm) in thickness cemented to the surface
of walls or ceTings 9 these materials have a flame — spread characteristic no greater than
paper of this thickness cemented to a noncombustible bocidng.
R315.2 Smoke — developed index.
Wall and ceiling finishes shall have a smoke— developed index of not greater than 450.
r I of r
WINDOW AND DOOR ASSEMBLIES AND THEIR INSTALLATION SHALL BE IN
ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AS SET FORTH
IN APPROVED PRODUCT CONTROL SUBMITTALS PER THE F.B.C.
ALL FIXED GLASS PANELS SHALL BE 3/16' OR THICKER AS REQ. TO MEET
WIND LOADS AND IMPACT REQUIREMENTS, SAFETY GLASS. ALL GLASS USED
INSIDE OF DWELLING TO BE TEMPERED, TO COMPLY WITH THE F.B.C.
EGRESS TYPE WINDOWS MALL BE OPERABLE FROM THE INSIDE WITHOUT
THE USE OF KEY, TOOL, OR SPECIAL KNOWLEDGE OR EFFORT, AND SHALL
PROVIDE A CLEAR OPENING OF NOT LESS THAN 20" WIDE, 24' HIGH, AND
5.7 FEET IN AREA. THE BOTTOM OF THE OPENING SHALL NOT BE MORE
THAN 44' ABOVE THE FLOOR, AND NO PART OF THE MECHANISM SHALL
BE PLACED HIGHER THAN 54' ABOVE THE FLOOR.
PROVIDE HURRICANE SHUTTERS APPROVED BY COUNTY PRODUCTS
CONTROL AT ALL REQUIRED DOOR AND WINDOW OPENINGS
WITH NON — IMPACT WINDOWS.
PROVIDE OPAQUE GLASS AT BATHROOM WINDOW AS PER F.B.C.
PROVIDE SAFETY TEMPERED GLASS AS PER F.B.C. FOR WINDOW
AND SHOWER ENCLOSURE.
Contractor shall verify with window and doors manufacturers
required masonry opening for proper installation before concrete
block work is started or tie columns are poured.
CAT. II SAFETY GLASS SHALL BE USED AT ALL SHOWER
AND TUB ENCLOSURES INCLUDING WINDOWS WITH SILLS
LOWER THAN 60" AND MIRRORS IN THE TUB.
ALSO, IT SHALL BE USED ON OPENINGS WITHIN 12'
OF DOORS.
ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE
OF 300 LB. APPLIED IN ANY MOVABLE DIRECTION IN ACCORDANCE WITH
RESISTANCE STANDARDS SET FORTH IN F.B.C.
PANELS.
FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR SCOPE
OR VISION
DOORS MID WINDOWS
SUBMIT SHOP DWG's FOR APPROVALS IN SEPARATE PERMIT
F'31 1111112F.4 r . ti. r 1 . �, • �• 1
NOTE
ALL NEW ENDOWS TO BE PROVIDED W/ MIAMI—DADE
APPROVED
ALL SHUTTERS TO BE DESIGNED BY A QUALIFIED
REGISTERED DELEGATE ENGINEER FOLLOWNG
PROCEDURES # FORTH
OF : C. RESIDENTIAL 2007 E1
NOTE:
COORDINATE ALL MASONRY OPENINGS FOR WINDOWS do
DOORS WITH WINDOWS & DOOR MANUFACTURER PRIOR
TO TIE BEAM AND BLOCK ERECTION.
CEILING AS PER R315.1 FBC—RESIDENTIAL 2007 WALL MD
#
CLASSIFICATION OF + GREATER THAN 200
BURGLARY
NOTES:
r• aI• �r • 1 a s' 1 • f . I t#
•r'r « r +• f« r f
a
1 1 #11` "1 11r •#
:1 + • t • s• x r r 1.. # ti
. #_s.
•s r
f a• r• / � 1r#.
•• a r> r � r r�
D T r• ►11- i �- !
If• r r +11' #
1, ► , y1 � 1 • F
.« .2.
1 • �2' 1 • 1 1
�• f• # ##
# •f
«r • • #
/« • a �• r• 1rr•
1• •f fr / 1.11• # f#
I I I
I i
1.. L G
architecture
P l a n n i n g
interior design
AA 260007711
1B 26Q006W
250 Catalonia, suite 403
coral gables, florida 33134
telephone : 305 .567. 1977
facsimile : 305.567. 1125
REVISIONS:
! °3
A
A
SCALE:
LLj
DRAWN BY.
A.P.
CHECKED BY:
P.B.
DATE:
05 -13.10
A
I■
,
SUBMITTAL SCHEMATIC DESIGN
i
i
s
REVISIONS:
! °3
A
A
SCALE:
AS NOTED
DRAWN BY.
A.P.
CHECKED BY:
P.B.
DATE:
05 -13.10
PROJECT NO.:
FILE NAME:
SUBMITTAL SCHEMATIC DESIGN
SHEET NUMBER
A-1 2
. j.2 .7411
P. CARLOS BRAVO, RA
FLA, REGISTRATION NO.: 6226