Loading...
12-265-001n S.W. 76-th Street Location Sketch NTS FLOOD LEGEND Residential Addition ADDRESS: 6510 SW 75 TERRACE WAIII, FLORA 33143 LOT- 1 — BLOCK: 10 PLAT BOOK: 64 PAGE: 80 HIGHEST CROWN OF ROAD ELEV.: —FT. NGVD. HIGHEST CROWN OF ROAD ELEVATION WAS TAKEN FROM THE ATTACHED CERTIFIED SURVEY, OR A CERTIFIED SURVEY PREPARED BY. NELSON MOJARENA PLS LIC.1- 5504 SURVEYOR'S NAME LOWEST FLOOR GARAGE/STORAGE ADJACENT GRADE SWALE AREA ELEVATION FLOOR ELEVATION ELEVATION ELEVATION PROPOSED FT. NGVD FT. NGVD FT. NGVD FT. NGVD ALL ELECTRICAL, MECHANICAL AND PLUMBING WILL BE PLACED AT OR ABOVE THE BASE FLOOD ELEVATION. (B.F.E.) ALL AREAS BELOW B.F.E. SHALL BE PROVIDED WITH A MINIMUM OF TWO (2) OPENINGS HAVING A TOTAL NET AREA OF NO LESS THAN ONE SQUARE INCH OF OPENING FOR EVERY SQUARE FOOT OF ENCLOSED AREA SUBJECT TO FLOODING. THE BOTTOM OF THE OPENING WILL BE NO HIGHER THAN ONE (1) FOOT ABOVE GRADE AND LOCATED ON DIFFERENT SIDES OF THE ENCLOSED AREA. OPENINGS WILL BE EQUIPPED WITH SCREENS OR LOUVERS. FLOOD RESISTANT MATERIALS WILL BE USED BELOW B.F.E. ALTERNATIVELY, SEE A CERTIFICATION BY P.E. ON THE PLAN NOTES INDICATING THAT THE DESIGN WILL ALLOWED FOR THE AUTOMATIC EQUALIZATION OF HYDROSTA11C FLOOD FORCES ON EXTERIOR WALLS. THE SITE WILL BE GRADED IN A MANNER TO PREVENT THE FLOODING OF ADJACENT PROPERTIES. WHERE NECESARY INTERCEPTOR SWALES WILL BE CONSTRUCTED ON-SITE WITH NO ENCROACHMENT OVER ADJACENT PROPERTIES. 0' -0'= NGVD 4 • I T Y 0 s 0 U H NA BUILDING, DEPT. LEGAL DESCRIPTION STRUCLTI URAL SEC, 710N, LOT 1 IN BLOCK 10, PARK MANOR FOURTH ADDITION, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 64, AT PAGE 80, OF THE PUBLIC RECORDS OF MIAMI-DADE COUNTY, FLORIDA TERMITE SOIL STATEMENT ALL BUILDING SHALL HAVE A PRE-CONSTRUCTION TREATMENT PROTECTION AGAINTS SUBTERRANEAN TERMITES. THE RULES AND LAWS AS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES SHALL BE DEEMED AS APPROVED WITH RESPECT TO PRECONSTRUCTION SOIL TREATMENT FOR PROTEC11ON AGAINST SUBTERRANEAN TERMITES. A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: " THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES (AS PER R4409.13.5 FBC 2004) SOIL STATEMENT SOIL AT THIS SITE IS ROCK AND SAND, ADEQUATE TO SUPPORT THE DESIGN LOAD OF 2,500 P.S.F. AFTER EXCAVATION, SIGNED AND SEALED I ETTER WILL BE SUBMITTED BY THE ARCHITECT OR THE ENGINEER ATTESTING THAT THE SITE HAS BEEN OBSERVED AND THE FOUNDATION COND111ONS ARE SIMILAR TO THOSE UPON WHICH THE DESIGN IS BASED ON. B R A v 0 L L C a r c h i t e c t u r e p I a n n I n g i n t e r i o r d e s i g n 250 catatonia, suite 403 coral gables, florida 33134 telephone : 305 .567. 1977 facsimile : 305 . 567 . 1125 • Cti T. I u P. CARLOS BRAVO, RA FLA. REGISTRATION NO.: i 'It Z LLJ • < w (y) 0 F­ Ix w F- Z 0 1jj 0 LL (n • 0 2 • Cti T. I u P. CARLOS BRAVO, RA FLA. REGISTRATION NO.: i