13-319-006WAi pf HVAC DESIGN REQUIREMENTS YES NO DUCT SMOKE DETECTOR GREENHECK MODEL FIRE DAMPER(S) SYSTEM TYPE EXHAUST SMOKE DAMPER (S) 50 E.S.P. FIRE RATED ENCLOSURE FAN SPEED (rpm) � F.RATED R CEILING ASSEMBLY 18.3 AMPS FIRE STOPPING WATTS---Hz 115 -N1 -60 SMOKE CONTROL DIRECT AREA SERVED I,ppPP�E� G L�V IN �E ��R 0 Ep 0p m T A pEp p N E OLL f5jp WAI, 1NpA ON PACKAGED TERMINAL AIR CONDITIONER INSTALLATION DETAIL. nts VENTILATION EQUIPMENT SCHEDULE MARK EF -1 BRAND GREENHECK MODEL SP -A50 SYSTEM TYPE EXHAUST EXHAUST VOLUME 50 E.S.P. 0.1 FAN SPEED (rpm) 700 MOTOR POWER (W) 18.3 AMPS 0.31 WATTS---Hz 115 -N1 -60 DRIVE DIRECT AREA SERVED SINGLE FIX. BATH WEIGHT (Ibs) 12 BACK DRAFT D. INCLUDED ACCESORIES -- HEAT PUMP EQUIPMENT SCHEDULE DESIGNATION PTAC SUPPLY CFM/ 0/A CFM 310 0 TOTAL COOLING CAPACITY, BTU /HR. 7600 SENSIBLE COOLING CAPACITY, BTU /HR. 5540 HEATING CAPACITY BTU /H 6800 COP 3.3 OUTSIDE AIR TEMPERATURE 93' AIR TEMP. ENT. EVAP., DB /WB 80/67 M.C.A. 4.2 AMPS 3.5 WATTS 650 VOLTAGE, PHASE, CY 208/230/01 60 MODEL PTH073EOOAV MANUFACTURER AMANA UNIT TYPE PTAC SEER OR EER 11.4 REFRIGERANT TYPE R -410 DRAIN PIPE (OD) a" UNIT WEIGHT (LBS.) 108 UNIT DIMENSIONS (HxWxD) inches 16 -Tb"X42 "X21 -j" FLEXIBLE F': METALIC DUtg STAINLESS STEEL' HOSE CLAMP. WALL ANCHOR WEATHER PROOF, NON- HARDENING SILICON CAULK. r GALV. WALL CAP WITH BACK DRAFT DAMPER AND CORROSION RESISTANT SCREEN WITH OPENINGS ) J" & < ". - BACKDRAFT FLAP CORR. RESISTANT SCREEN WALL CAP DETAIL N TS SCOPE OF WORK: 1. MECHANICAL CONTRACTOR TO PROVIDE (1) PTAC UNIT AS SCHEDULED. 2. PROVIDE (1) NEW CEILING EXHAUST FAN IN NEW BATHROOM AND (1) NEW DUCT AND WALL CAP TO SERVE RELOCATED DRYER. NO ADDITIONAL MECHANICAL WORK SHALL BE DONE IN THIS SPACE. north REPLACE EXISTING W/H BY NEW TANKLESS W/H TITAN -SCR2 I MODEL N -120 OR SIMILAR I I 6 "X6 "X4" SIDE WALL CAP WITH BACK I �DRAFT DAMPER (WITHOUT SCREEN). I i i /T L -__J EXISTING DINING ROOM I - 04" SHEET METAL DUCT. GA. 26. ST. NEW UTILITY ROOM NEW FAMILY ROOM 310 CFM <--- U'C�fFL^ METALI k RELOCATE EXISTING I WASHER /DRYER COMBO I I I -NEW PTAC UNIT. ROUTE 01" I DRAIN PIPE TO SOIL AREA AT 6" ABOVE GROUND AND I 12" AWAY FROM STRUCTURE. SEE I EQUIPMENT SCHEDULE. WALL CAP. I SEE DETAIL. I 1 FLOOR PLAN — MECHANICAL 1/4" •••• F. P/ • ••��p XA S E J .o F LO�;••� •� PREPARED BY- CONSULTANT ino Curtis, PE Corp. (C.A. #: 27293) Engineering Services Alejandro F. Pino (PE Lic:• 59459) 1484Z SW 34th Ln Miami FL33185 ph: 305) 562 8676 pinocurti.§pe@bellsouth.net F N V7 ISIONS: -1 REV.1 REV.3 0 U Z 00 M N 000 M O Z z w w o U 5 z O I---1 C%1 Fil W z O V W V w Z I—I O Fri U Q W oo W z O O M kn M 00 A Q qq O Z Q O x a Job No.: SITE PLAN Drawn Bp AC Scale: 1/4 Date : 03113 M71