12-746-008CO DENS
MIN. 5000 POUND UP -LIFT
BOLTED FROM INSIDE THE UNIT
6' MINA
PROVIDE ADDITIONAL (3 EACH SIDE)
HILTI SHOTS 2' MIN. EMBEDMENT
INSIDE COMP. UNIT (TYP.)
CONCRETE BASE WI'v�
6X6- 10 /10ULF
HVAC 146 MPH
SEAL ENTRANCE OF REFRIGERANT –
LINES INTO P.V.G. PIPE W/
IMPERMEABLE, RESILIENT MATERIAL
CONDENSING UNIT MOUNTING DETAIL
MECHANICAL ATTACH -
PLENUMS AND RETURN
W/ FLEXIBLE CONN.
PROVIDE 6' CLEAR —
AROUND AHU
PROVIDE SAFETY
FLOAT SWITCH
DEVICE
2' COND. DRAIN —
UNDERGROUND-
(SEE A/C FL. PLAN
FOR TERMINATION)
00 SUPPLY AIR DUCT
R -6 MIN. INSULATION
DISCONNECT SWITCH
LIQUID LINE TO C. U.
SUCTION LINE TO C. U.
AIR CONDITIONING CLOSET
LOW VELOCITY —
SUPPLY AIR DUCT
(SEE PLAN VIEW)
SEAL JOINT WI
DUCT SEALER
AND TAPE
DRAW BAND AIR 'Li
(III V
SPIN COLLAR
FITTING WITH V DAMPER
DIFFUSER
REGISTER
/j
C
41R HANDLING UNIT
METAL BASE
RAISE RAG
N.T.S.
d CONTROL
TOONS
MIN.
MIN.
LIQUID LINE
W/O INSULATION
INSULATED FLEX. DUCT (R -6 INSUL -)
-SEAL JOINT WITH
DUCT SEALER
AND TAPE
\� 1
A/C SPLIT SYSTEM SCHEDULE
UNIT MODEL
(1 -1/2 TONS)
TOTAL CAPACITY BTU /HR
19,200
SENS CAPACITY BTU /HR
14 ,200
CFM SUPPLY
600
NEATER KW
5
ESP -IN UJG.
0.30
TEMP. AIR ENT. COIL DB/lUB
80/61
C.U. FLA
10.4
VOLTAGE
1 -60 -240
MANUFACTURER
RHEEM
AHU MODEL
R15HPI7J06
G.U. MODEL
14AX118A01
SEER
16.0
REF LIQUID /SUCTION
1/4' - 3/4'
—MIN. DUCT INSULATION SHALL BE R -6 FOR A/C DUCT
IN NON AIR CONDITIONING SPACES
— PROVIDE PROGRAMMABLE THERMOSTAT.
4' SCHEDULE
40 P.V.C. PIPE
INCREASE SIZE
AS REQUIRED BY
LENGTH AND ROUTING
- SUCTION LINE W/ 1 -1/2'
ARMAFLEX INSULATION
t VAPOR BARRIER
N.T.S.
44, BATHROOM EXH. (30 GAUGE MIN)
THRU ROOF W/ ROOFCAP,
BD.D. AND BIRD SCREEN
PROVIDE CORROSION
RESISTANT SCREEN. (TYP-) NEW CU.
FLEXIBLE DUCT CONNECTION DETAIL
N.T.S.
HVAC DESIGN REQUIRES
AIR CONDITIONING LEGEND
NO
SYMBOL
LEGEND
O
THERMOSTAT
A.N.U.
AIR HANDLING UNIT
SMOKE DAMPER($)
DUCTWORK
G.U.
CONDENSING UNIT
W
X
OA.
OUTSIDE AIR
FLEXIBLE DUCT
RA.
RETURN AIR
SMOKE CONTROL
W
X
V
®
SUPPLY AIR DIFFUSER
S.A.
SUPPLY AIR
Q
W
O
G.F.M.
CUBIC FEET PER MINUTE
z
EXHAUST FAN
HVAC DESIGN REQUIRES
YES
NO
DUCT SMOKE DETECTOR
X
FIRE DAMPER(5)
I
i
i
1
i
i
I
s
i
i
i
X
SMOKE DAMPER($)
X
FIRE RATED ENCLOSURE
W
X
FIRE RATED ROOF CEILING ASSEMBLY
X
FIRE STOPPING
X
SMOKE CONTROL
W
X
NOTE:
M130511 Furnaces and air handlers.
Furnaces and air handlers within compartments or alcoves shall have a
minimum working space clearance of 4 inches (102 mm) along the sides, back
and top with a total width of the enclosing space being at least 12 inches
(305 mm) wider than the furnace or air handler. Furnaces having a firebox
open to the atmosphere shall have at least a 6 -inch (152 mm) working space
along the front combustion chamber side. Combustion air openings at the
rear or side of the compartment shall comply with the requirements of
EXIST. 4' DRTER EXH.
(V.IF-) (30 GAUGE MIN-)
VENT THRU WALL W/ CAP
BACK DRAFT DAMPER
MOT SCREENED)
7 WM./DR
NEW \� NEW
MASTER BATH LAUNDRY
8m CFM
T 60 CPA
I'S 6'4
NEW
AM
l� �J
EX
KIT
— _ 14' \ �' U
m
3/4' COND. DRANK 1 R/A
6' ABOVE GRADE FLD PROVIDE 100 SQIN.
AND 12' OFF WALL DRYER MAKE -UP
16x 0 AIR GRILL
12x8 CD — RAG
190 CFM
NEW a'
MASTER IST. BOX
BEDROOM
8' NEW
I roxrp Co I
12xS CD
1W CFM 60 Cm
T
�� II
EX
DINiN
AIR CONDITIONING GENERAL NOTES - -- - --
GENERAL.
PROVIDE (FURNISH AND INSTALL) ALL NECESSARY
MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL
AIR CONDITIONING, HEATING AND VENTILATING SYSTEM AS
SHOWN ON THE DRAWINGS, AND HEREIN SPECIFIED.
INSTALL IN ACCORDANCE WITH THE FLORIDA BUILDING CODE,
ASHRAE, SMACNA, NFPA AND LOCAL ORDINANCES
SCOPE OF WORK:
PROVIDE THE FOLLOWING COMPLETE SYSTEMS:
A. SUPPLY DUCT SYSTEM.
B. EXHAUST SYSTEM FOR BATHROOMS
C. AIR CONDITIONING UNITS WITH REFRIGERANT PIPING
AND CONTROLS.
PAY FOR ALL FEES, INSPECTIONS AND CONNECTION
CHARGES REQUIRED
VERIFY AT JOB SITE ALL SPACE CONDITIONS, DIMENSIONS
AND EQUIPMENT 51ZES PRIOR TO DUCT FABRICATION OR
INSTALLATION. COORDINATE REQUIREMENTS TO AVOID
INTERFERENCE WITH OTHER TRADES.
GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS
AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM
DATE OF ACCEPTANCE.
MATERIALS
DUCTWORK
GENERAL. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE
DIMENSIONS.
NOTE:
1-1I601.16 REGISTERS, GRILLES AND DIFFUSERS. DUCT REGISTERS,
GRILLES AND DIFFUSERS SHALL BE INSTALLED
IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION
INSTRUCTIONS, AND SHALL HAVE A FLAME SPREAD
RATING NOT OVER 25 WITHOUT EVIDENCE OF CONTINUED
PROGRESSIVE COMBUSTION AND A SMOKE - DEVELOPED
RATING NOT OVER 50 WHEN TESTED IN ACCORDANCE WITH ASTM
E84. BALANCING DAMPERS OR OTHER MEANS OF SUPPLY
AIR ADJUSTMENT SHALL BE PROVIDED IN THE CP.ANCH DUCTS
OR AT EACH INDIVIDUAL DUCT REGISTER, GRILLE OR DIFFUSER
PROVIDE DOUBLE THICKNESS TURNINri- -VANES 4T- ALL
SQUARE ELBOWS. WHERE THE ELBOWe ARE RECTANGULAR
INSTALL SINGLE THICKNESS INSTEAD.- -
REFRIGERANT PIPING. SEAMLESS COf'" �2 T"P:E 'L' AND
HARD OR SOFT DRAWN ON ACR COPPER TUBING WITH
WROUGHT COPPER SOLDER JOINT FITTINGS, SOLDER
SHALL BE 95/5 APPLIED WITH SUITABLE FLUX.
INSULATE ALL REFRIGERANT SUCTION PIPING WITH 1/2'
CLOSED CELL POLYETHYLENE PREMOLDED PIPE
INSULATION, WITH AN APPROVED PIPE AND SMOKE
JACKET. PAINT ALL EXPOSED INSULATION WITH TWO
COATS OF WHITE LATEX PAINT.
PROVIDE AIR CONDITIONING UNITS WITH MATCHING LOW
VOLTAGE HEAT -COOL THERMOSTATS WITH ON -OFF AUTO
SUB -BASE SWITCH, FURNISHED BY THE EQUIPMENT
MANUFACTURER
ALL AIR CONDITIONING COMPRESSORS SHALL BE
WARRANTED FOR A MINIMUM OF FIVE YEARS AFTER DATE
OF ACCEPTANCE OF THE PROJECT.
AIR DISTRIBUTION PRODUCTS :
PROVIDE SUPPLY AND DIFFUSERS
AS INDICATED ON THE DRAWINGS.
PROVIDE FINISHES AND TYPES OF MOUNT IN COORDINATION
WITH THE CEILING TYPES AS SHOWN ON ARCHITECTURAL
DRAWINGS.
INSTALLATION
INSTALL ALL EQUIPMENT IN ACCORDANCE TO THE
MANUFACTURER'S MANUAL AND RECOMMENDATIONS
PAYING SPECIAL ATTENTION TO REQUIRED CLEARANCES
FOR INSTALLATION, OPERATION AND SERVICE.
NOTE:
PROVIDE 1' UNDERCUT
AT ALL BEDROOM DOORS
EXH FAN SCHEDULE
EF -1 SHALL BE GROAN MODEL 360 9 120V/IPH /60 HZ
1/4' SP 110 CFM W/ BACKDRAFT DAMPER
J tAl,711NC3
-- — — — — — — — — — — — — — — — — BEDROOM *1
EXISTING
COV. PORCH
ELECT. PANEL
MECHANICAL FLOOR PLAN
SCALE 1/4" = 1' -0"
II �
I
EXIS'
CLO&
I
I
EXIST. C.U.
ELECT.
METER : DISC.
EXISTING_
BATH
i
EXiSTING
BEDROOM I
I
OLR
ARCHITECT
ORESTES LOPEZ -RECIO
AR00093.50
I
1700 S.W. 57 AVENUE I
SUITE 22 i
MIAMI, FLORIDA 33155
TELEPHONE: (305) 360 -2W..
(7„6) 566 -9673 t
I
I
i
i
1
i
i
I
s
i
i
i
F�1
PTO�T�
I
I
I
O
W
V rOl
U
O
W
V
A�
Q
W
O
P-4
Aii
REVISIONS
DATE.'oi:C�l:
SCALE
DRAWN: "L
JOB NO.
SHEET NO. 1 OF