12-746-008CO DENS MIN. 5000 POUND UP -LIFT BOLTED FROM INSIDE THE UNIT 6' MINA PROVIDE ADDITIONAL (3 EACH SIDE) HILTI SHOTS 2' MIN. EMBEDMENT INSIDE COMP. UNIT (TYP.) CONCRETE BASE WI­­'v� 6X6- 10 /10ULF HVAC 146 MPH SEAL ENTRANCE OF REFRIGERANT – LINES INTO P.V.G. PIPE W/ IMPERMEABLE, RESILIENT MATERIAL CONDENSING UNIT MOUNTING DETAIL MECHANICAL ATTACH - PLENUMS AND RETURN W/ FLEXIBLE CONN. PROVIDE 6' CLEAR — AROUND AHU PROVIDE SAFETY FLOAT SWITCH DEVICE 2' COND. DRAIN — UNDERGROUND- (SEE A/C FL. PLAN FOR TERMINATION) 00 SUPPLY AIR DUCT R -6 MIN. INSULATION DISCONNECT SWITCH LIQUID LINE TO C. U. SUCTION LINE TO C. U. AIR CONDITIONING CLOSET LOW VELOCITY — SUPPLY AIR DUCT (SEE PLAN VIEW) SEAL JOINT WI DUCT SEALER AND TAPE DRAW BAND AIR 'Li (III V SPIN COLLAR FITTING WITH V DAMPER DIFFUSER REGISTER /j C 41R HANDLING UNIT METAL BASE RAISE RAG N.T.S. d CONTROL TOONS MIN. MIN. LIQUID LINE W/O INSULATION INSULATED FLEX. DUCT (R -6 INSUL -) -SEAL JOINT WITH DUCT SEALER AND TAPE \� 1 A/C SPLIT SYSTEM SCHEDULE UNIT MODEL (1 -1/2 TONS) TOTAL CAPACITY BTU /HR 19,200 SENS CAPACITY BTU /HR 14 ,200 CFM SUPPLY 600 NEATER KW 5 ESP -IN UJG. 0.30 TEMP. AIR ENT. COIL DB/lUB 80/61 C.U. FLA 10.4 VOLTAGE 1 -60 -240 MANUFACTURER RHEEM AHU MODEL R15HPI7J06 G.U. MODEL 14AX118A01 SEER 16.0 REF LIQUID /SUCTION 1/4' - 3/4' —MIN. DUCT INSULATION SHALL BE R -6 FOR A/C DUCT IN NON AIR CONDITIONING SPACES — PROVIDE PROGRAMMABLE THERMOSTAT. 4' SCHEDULE 40 P.V.C. PIPE INCREASE SIZE AS REQUIRED BY LENGTH AND ROUTING - SUCTION LINE W/ 1 -1/2' ARMAFLEX INSULATION t VAPOR BARRIER N.T.S. 44, BATHROOM EXH. (30 GAUGE MIN) THRU ROOF W/ ROOFCAP, BD.D. AND BIRD SCREEN PROVIDE CORROSION RESISTANT SCREEN. (TYP-) NEW CU. FLEXIBLE DUCT CONNECTION DETAIL N.T.S. HVAC DESIGN REQUIRES AIR CONDITIONING LEGEND NO SYMBOL LEGEND O THERMOSTAT A.N.U. AIR HANDLING UNIT SMOKE DAMPER($) DUCTWORK G.U. CONDENSING UNIT W X OA. OUTSIDE AIR FLEXIBLE DUCT RA. RETURN AIR SMOKE CONTROL W X V ® SUPPLY AIR DIFFUSER S.A. SUPPLY AIR Q W O G.F.M. CUBIC FEET PER MINUTE z EXHAUST FAN HVAC DESIGN REQUIRES YES NO DUCT SMOKE DETECTOR X FIRE DAMPER(5) I i i 1 i i I s i i i X SMOKE DAMPER($) X FIRE RATED ENCLOSURE W X FIRE RATED ROOF CEILING ASSEMBLY X FIRE STOPPING X SMOKE CONTROL W X NOTE: M130511 Furnaces and air handlers. Furnaces and air handlers within compartments or alcoves shall have a minimum working space clearance of 4 inches (102 mm) along the sides, back and top with a total width of the enclosing space being at least 12 inches (305 mm) wider than the furnace or air handler. Furnaces having a firebox open to the atmosphere shall have at least a 6 -inch (152 mm) working space along the front combustion chamber side. Combustion air openings at the rear or side of the compartment shall comply with the requirements of EXIST. 4' DRTER EXH. (V.IF-) (30 GAUGE MIN-) VENT THRU WALL W/ CAP BACK DRAFT DAMPER MOT SCREENED) 7 WM./DR NEW \� NEW MASTER BATH LAUNDRY 8m CFM T 60 CPA I'S 6'4 NEW AM l� �J EX KIT — _ 14' \ �' U m 3/4' COND. DRANK 1 R/A 6' ABOVE GRADE FLD PROVIDE 100 SQIN. AND 12' OFF WALL DRYER MAKE -UP 16x 0 AIR GRILL 12x8 CD — RAG 190 CFM NEW a' MASTER IST. BOX BEDROOM 8' NEW I roxrp Co I 12xS CD 1W CFM 60 Cm T �� II EX DINiN AIR CONDITIONING GENERAL NOTES - -- - -- GENERAL. PROVIDE (FURNISH AND INSTALL) ALL NECESSARY MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL AIR CONDITIONING, HEATING AND VENTILATING SYSTEM AS SHOWN ON THE DRAWINGS, AND HEREIN SPECIFIED. INSTALL IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, ASHRAE, SMACNA, NFPA AND LOCAL ORDINANCES SCOPE OF WORK: PROVIDE THE FOLLOWING COMPLETE SYSTEMS: A. SUPPLY DUCT SYSTEM. B. EXHAUST SYSTEM FOR BATHROOMS C. AIR CONDITIONING UNITS WITH REFRIGERANT PIPING AND CONTROLS. PAY FOR ALL FEES, INSPECTIONS AND CONNECTION CHARGES REQUIRED VERIFY AT JOB SITE ALL SPACE CONDITIONS, DIMENSIONS AND EQUIPMENT 51ZES PRIOR TO DUCT FABRICATION OR INSTALLATION. COORDINATE REQUIREMENTS TO AVOID INTERFERENCE WITH OTHER TRADES. GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE. MATERIALS DUCTWORK GENERAL. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS. NOTE: 1-1I601.16 REGISTERS, GRILLES AND DIFFUSERS. DUCT REGISTERS, GRILLES AND DIFFUSERS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND SHALL HAVE A FLAME SPREAD RATING NOT OVER 25 WITHOUT EVIDENCE OF CONTINUED PROGRESSIVE COMBUSTION AND A SMOKE - DEVELOPED RATING NOT OVER 50 WHEN TESTED IN ACCORDANCE WITH ASTM E84. BALANCING DAMPERS OR OTHER MEANS OF SUPPLY AIR ADJUSTMENT SHALL BE PROVIDED IN THE CP.ANCH DUCTS OR AT EACH INDIVIDUAL DUCT REGISTER, GRILLE OR DIFFUSER PROVIDE DOUBLE THICKNESS TURNINri- -VANES 4T- ALL SQUARE ELBOWS. WHERE THE ELBOWe ARE RECTANGULAR INSTALL SINGLE THICKNESS INSTEAD.- - REFRIGERANT PIPING. SEAMLESS COf'" �2 T"P:E 'L' AND HARD OR SOFT DRAWN ON ACR COPPER TUBING WITH WROUGHT COPPER SOLDER JOINT FITTINGS, SOLDER SHALL BE 95/5 APPLIED WITH SUITABLE FLUX. INSULATE ALL REFRIGERANT SUCTION PIPING WITH 1/2' CLOSED CELL POLYETHYLENE PREMOLDED PIPE INSULATION, WITH AN APPROVED PIPE AND SMOKE JACKET. PAINT ALL EXPOSED INSULATION WITH TWO COATS OF WHITE LATEX PAINT. PROVIDE AIR CONDITIONING UNITS WITH MATCHING LOW VOLTAGE HEAT -COOL THERMOSTATS WITH ON -OFF AUTO SUB -BASE SWITCH, FURNISHED BY THE EQUIPMENT MANUFACTURER ALL AIR CONDITIONING COMPRESSORS SHALL BE WARRANTED FOR A MINIMUM OF FIVE YEARS AFTER DATE OF ACCEPTANCE OF THE PROJECT. AIR DISTRIBUTION PRODUCTS : PROVIDE SUPPLY AND DIFFUSERS AS INDICATED ON THE DRAWINGS. PROVIDE FINISHES AND TYPES OF MOUNT IN COORDINATION WITH THE CEILING TYPES AS SHOWN ON ARCHITECTURAL DRAWINGS. INSTALLATION INSTALL ALL EQUIPMENT IN ACCORDANCE TO THE MANUFACTURER'S MANUAL AND RECOMMENDATIONS PAYING SPECIAL ATTENTION TO REQUIRED CLEARANCES FOR INSTALLATION, OPERATION AND SERVICE. NOTE: PROVIDE 1' UNDERCUT AT ALL BEDROOM DOORS EXH FAN SCHEDULE EF -1 SHALL BE GROAN MODEL 360 9 120V/IPH /60 HZ 1/4' SP 110 CFM W/ BACKDRAFT DAMPER J tAl,711NC3 -- — — — — — — — — — — — — — — — — BEDROOM *1 EXISTING COV. PORCH ELECT. PANEL MECHANICAL FLOOR PLAN SCALE 1/4" = 1' -0" II � I EXIS' CLO& I I EXIST. C.U. ELECT. METER : DISC. EXISTING_ BATH i EXiSTING BEDROOM I I OLR ARCHITECT ORESTES LOPEZ -RECIO AR00093.50 I 1700 S.W. 57 AVENUE I SUITE 22 i MIAMI, FLORIDA 33155 TELEPHONE: (305) 360 -2W.. (7„6) 566 -9673 t I I i i 1 i i I s i i i F�1 PTO�T� I I I O W V rOl U O W V A� Q W O P-4 Aii REVISIONS DATE.'oi:C�l: SCALE DRAWN: "L JOB NO. SHEET NO. 1 OF