12-746-007GENERAL LIGHTING LOAD WATTS 2,063 S.F. Q 3W /5F = 6,189 WATTS. TWO SMALL APPLIANCES CIRCUITS X 1,500 3,000 WATTS FIXED APPLIANCES: EXIST. REFRIGERATOR 1 ,000 WATTS EXIST. DISHWASHER 1200 WATTS EXIST. INSTANT W. HEATER 15,600 WATTS EXIST. DRYERNIASHER 5,000 WATTS EXIST. KITCHEN HOOD 800 WATTS EXIST. RANGE 12,000 WATTS EXIST. SPRINKLER 2,000 WATTS CONNECTED LOAD LESS A/C 10 ,000 W m 100% REST W m 40% A/C (OR HEATING) m 100% (2) DEMAND LOAD = 37,216 /240 WATTS = SERVICE SIZE = 200AMPS. (EXISTING) NEUTRAL LOAD LIGHTING, SMALL APPLIANCE 4 WASHER = FIRST 3,000 W m 100% = REST m 3590 = RANGE X 0.1%= DRYER X 0.1= OTHER 120V APPLIANCE _ TOTAL NEUTRAL WATTS = 22,591 155 46,189 WATTS — 10,000 WATTS 14,116 WATTS 12,500 WATTS AMPS m 240/120 V 10,689 WATTS 3,000 WATTS 2,691 WATTS 6,400 WATTS 3,500 WATTS 5.000 WATTS 94 COND SIZE+ 3/4' TOTAL VA 8,000 NOTE: SMOKE DETECTOR SYSTEM TO 5E INSTALLED IN ACCORDANCE W/ NFPA 72/99 NOTE: SMOKE DETECTOR SHALL NOT BE CLOSER THAN 3' FROM AIR REGISTER AND BATH DOOR AND 20' FROM COOKING APPL. NOTE: ALL NEW OUTLETS TO BE TAMPER RESISTANTS. NOTE: ALL SINGLE STATION SMOKE DETECTORS MUST BE INTERCONNECTED, 120 VOLTS WITH BACKUP AND A MINIMUM OF 36 INCHES FROM THE AC SUPPLY. NOTE: ALL OUTLETS INSTALLED IN THE KITCHEN SHALL COMPLY WITH NEC: 21052. ALL OUTLETS INSTALLED IN THE KITCHEN MUST BE SUPPLIED BY SMALL APPLIANCES CIRCUITS AS PER NEC 210.52(5) (1) AND MUST HAVE PROPER COUNTER TOP SPACING AS PER NEC 210 (CXIX2). TYPE SQUARE 'D' or APPROVED EQUAL MAN BUS 200 AMPS SERVICE NEW ELECTRICAL PANEL NEUTRAL 200 AMPS VOLTAGE 240/120V 1 0 - 3AJ NEMA 3R MANS 200 AMPS MOUNTING SURFACE AIC 10000 AMPS POLES TOTAL VA COND SIZE4 WIRE REMARKS CKT. NO. SD DUPLEX RECEPTACLE CKT• NO. 2 REMARKS EXIST. RANGE WIRE 8 COND SIZE+ 3/4' TOTAL VA 8,000 L 2 30 2 5,000 3/4' 10 EXIST. ORYER/WASHER 1 V i-J CEILING MOUNTED FIXTURE H 3 �1 4 DATE C'ol.011: SCALE DRAWN -1 ! . JOB NO. 100 2 15,600 3/4' 4 EXIST. INSTANT W. HTR F 5 6 EXIST. A/C CU. 10 3/4' 5,000 2 1 8 SPACE 9 10 EXIST. A/C AHU 6 1' 1,500 2 SPACE Il 12 20 1 1000 1/2' 12 EXIST. REFRIGERATOR 13 14 EXIST. SMALL APPL. 12 1/2' 1,500 1 20 I 1200 1/2' 12 EXIST. DISHWASHER 15 16 EXIST. SMALL APPL. 12 1/2' 1,500 1 20 1 800 1/2' 12 EXIST. KITCHEN HOOD 11 18 GEN. LT. 4 RECEP. 12 1/2' 600 1 20 1 600 1/2' 12 GEN. LT. 4 RECEP. 19 20 EXIST. SPRINKLER 12 1/2' 2/000 1 15 1 600 1/2' 12 GEN. LT. 4 RECEP. 21 22 GEN. LT. 4 RECEP. 12 1/2' 600 1 15 1 600 1/2' 12 GEN. LT. 4 RECEP. 23 24 GEN. LT. 4 RECEP. 12 1/2' 600 1 20 1 600 1/2' 12 GEN. LT. 4 RECEP. 25 26 GEN. LT. 4 RECEP. 12 1/2' 600 1 20 1 600 IR' 12 GEN. LT. 4 RECEP. 21 28 GEN. LT, 4 RECEP. 12 1/2' 600 1 20 1 600 1/1' 12 NEW RECPTACLES 29 30 NEW BATH RECEP. GFI 12 1/1' 1,500 I 15 1 600 1/2' 12 NEW LIGHT MG 31 32 NEW CHEEK LT. 4 RECEP. 12 1/1' 600 1 30 2 SOW 3/4' 10 NEW A/C AW 33 34 36 NEW A/C CU 10 3/4' 3,500 2 35 SPACE 31 38 SPACE SPACE 39 40 SPACE FEEDER ; EXISTING 3.3/0 TNILN - 2' C. (V.IF.) FED FROM EXISTING SERVICE (V.T.) DEMAND LOAD : 31 .216 W • 155 AMPS (SEE LOAD CALCULATION) 10,000 AIC THE USE OF ROMEX IS ACCEPTABLE AMPS 40 ,o ELECTRICAL LEGEND: $ SWITCH $3 THREE -WAY SWITCH T DIMMER SWITCH �p THREE -WAY DIMMER SWITCH SD DUPLEX RECEPTACLE iJ POLED DUPLEX RECEPTACLE T SINGLE RECEPTACLE H3 SPECIAL RECEPTACLE WIF RECESSED LIGHTING --� WALL MOUNTED FIXTURE Z EXHAUST FAN `�O LOODLIGHT V i-J CEILING MOUNTED FIXTURE TV ORESTES LOPEZ -RECIO AR0009350 4 TELEVISION ANTENNA T TELEPHONE JACK ® SMOKE DETECTOR W/ SD BATTERY BACKUP iJ DISCONNECT SWITCH D ELECTRIC PANEL H3 ELECTRIC METER WIF WEATHER PROOF VP VAPOR PROOF O O O CEILING FAN /LIGHT 00 ELECTRICAL NOTES: I. OUT`5IPF- REGtPTAGLtb, KtGtt- I AGL= A I t7A I H, LtAKAU= ArvV ro rmm i rICV1 1 tai l c.r+civ �i1v� vnNCL mss= �r 2. SMOKE DETECTOR HARDWIRED TO KITCHEN OR BATHROOM NON- SWITCHA13LE NO GFI LIGHTING CIRCUIT INTERCONNECTED AND WITH BATTERY BACK -UP - -• - - 3. ELECTRICAL METER AND PANEL LOCATION MAY VARY AS PER SERVICE ENTRANCE LOCATION 4. ELECTRICAL CONTRACTOR TO COORDINATE SERVICE WITH F.P.L. - - - - 5. ALL 'J' BOXES SHALL COMPLY WITH NE.C. 310 -11A. 6. ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW BASE FLOOD ELEVATION SHALL BE INSTALLED AT THE HIGHEST PERMITTED ELEVATION AND SHALL BE INSTALLED ON (SEPARATE) INDEPENDENT CIRCUITS FROM THOSE IN THE HABITAT AREAS. 1. NO APPLIANCES OR APPLIANCE OUTLETS SHALL BE INSTALLED BELOW BASE FLOOD ELEVATION 8. A/C COMPRESSOR SHALL BE INSTALLED ABOVE BASE FLOOD ELEVATION S. MAIN CIRCUIT BREAKER PANELS SHALL BE LOCATED ABOVE BASE FLOOD ELEVATION 10. ELECTRICAL CONTRACTOR SHALL CONFER W/ FLORIDA POWER 4 LIGHT TO LOCATED THE ELECTRIC METER TO COMPLY W/ FEDERAL EMERGENCY MANAGEMENT AGENCY REQUIREMENTS. SITE INVESTIGATION: BEFORE BIDDING, CONTRACTOR SHALL PERFORM A THOROUGH INVESTIGATION OF ACTUAL CONDITIONS AT THE JOB SITE, AND INCLUDE WORK REQUIRED TO INTRODUCE SYSTEM COMPONENTS INTO EXISTING STRUCTURES, AND TO CONNECT OR MODIFY EXISTING SYSTEMS AS INDICATED ON DRAWINGS OR NECESSITATED BY THE INSTALLATION. PERFORM ALL SUCH WORK WITHOUT ADDITIONS TO THE CONTRACT COST. WHERE INDICATED ON DRAWINGS REMOVE OR RELOCATE EXISTING SYSTEM COMPONENTS AND PROPERLY PATCH AND FINISH RESULTING OPENINGS IN THE BUILDING STRUCTURE WITH THE SAME MATERIAL AS THOSE ADJACENT TO THE OPENING. a� 0 0 - - ---- OLR ELECTRICAL FLOOR PLAN SCALE 1/411 = 1' -011 ELECT. 4 DISC. A R C H I T E C T ORESTES LOPEZ -RECIO AR0009350 17(X1 S.N. 57 AVE',IUE SUITE 22 i MIAMI, FLORIDA 3315 I TELEPHONE: (305) 360 -1c;, ("136? Se6 -r6 � i I i i I !r f I 1 I i 1 i Fil PTO I i 1 I O Z W O rOl V 00 • q1t rO V d' O W V V A� H R �1 REVISIONS DATE C'ol.011: SCALE DRAWN -1 ! . JOB NO. SHEET NO. 1 OF