09-636-008ELECTRICAL NOTES
1. ALL WORK SHALL COMPLY WITH N.E.G., AND ALL OTHER APPLICABLE CODES AND /OR AUTHORITIES
HAVING JURISDICTION OVER THIS PROJECT.
2. THE ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL ALL WIRES, CONDUITS, CONNECTORS,
ETC. TO ACHIEVE A COMPLETE ELECTRICAL SYSTEM. WHERE ELECTRICAL EQUIPMENT, OUTLET, OR
OTHER FEATURES ARE REQUIRED BY CODE, BUT NOT SHOWN ON THE PLANS, THE ELECTRICAL
CONTRACTOR SHALL FURNISH AND INSTALL SAME, AS REQUIRED BY CODE.
3. ALL ELECTRICAL CONDUCTORS SHALL BE COPPER IN CONDUIT OR APPROVED EQUAL.
4. THE ELECTRICAL CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED PERMITS, APPROVALS,
AND INSPECTIONS.
5. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING AND PROCURING TEMPORARY
POWER DURING CONSTRUCTION ACCESSIBLE TO ALL TRADES.
6. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO CLEARLY LABEL THE CIRCUITS AT THE PANEL
WITH THEIR CORRESPONDING AREA CONTROLLED BY THAT CIRCUIT.
7. THESE PLANS CONSTITUTE A COMPLETE SET OF PLANS, THEREFORE NO SECTION STANDS ON ITS
OWN. THE ELECTRICAL CONTRACTOR SHALL COORDINATE THIS PLAN WITH ALL OTHER PLANS IN SET,
AS WELL HIS ACTUAL WORK WITH ALL OTHER TRADES, TO MINIMIZE CONFLICTS AT THE JOB SITE.
- ALL ELECTRICAL WORK SHALL BE DONE IN
ACCORDANCE WITH THE N.E.C, THE FLORIDA
BUILDING CODE 2007 EDITION AND ALL LOCAL
GOVERNING CODES.
- ALL ELECTRICAL LOADS ARE EXISTING TO REMAIN.
- ALL EXISTING ELECTRICAL SERVICE IS TO REMAIN
AS IS UNLESS OTHERWISE NOTED.
- INSTALLATION OF ALL CEILING OUTLET BOXES SHALL
BE ACCEPTABLE FOR FAN SUPPORT AS PER FB.C.2007
- VERIFY EXIST. ELEC. ITEMS IN FIELD, AND PROVIDE
NEW AS REQUIRED.
NOTE: EXISTING ELECTRICAL SERVICE IS SUFFICIENT
FOR NEW ELECTRICAL LOADS.
"E" - DENOTES EXISTING
"R' - DENOTES RELOCATED
ELECTRICAL LEGEND
SWITCH
DUPLEX RECEPTACLE
0 CEILING MOUNTED FIXTURE
EXISTING SERVICE TO FPL
i B
EXISTING 150 AMP. ELEC.
PANEL TO REMAIN
d
(FIELD VERIFY)
w
0
t
w
0
EXISTING 150 AMP DISC
0 SWITCH TO REMAIN
(FIELD VERIFY)
EXISTING 150 AMP ELEC. METER y^
TO REMAIN AS IS. j�
EXIST.1 # 6 THWN CU IN 1"
COND. TO REMAIN.
2 - 10'-0" DEEP GROUNDING
ROD - 5/8" DIAMETER
EXISTING 3 - #1/0 THWN.
CU. IN A 1 -1/2" CONDUIT
(FIELD VERIFY)
ELECTRICAL DIAGrxm
DAM
Electrical Plan
SCALE: 1/4'= T -0'
ml
wolt
0
GM
0
JAT
c, -,., *:
DATE
k
03.04.09
SCALE
U.S. MStructL<�res, n Irk .;
As Indicated
m�xtru&vral � ^_ i•aepr
JOB NO.
ry
SHEET
$
E -1
4444 SW 71st AVENUE, SUITE„103,
OF
MIAMI, FLORIDA33155
305.665.4555 FAX 305.665.5522
•
info @usstructuresinccom'
•
t
CA 8439 . w
f
�
.
i
i
.
Lo
•
wolt
REVISIONS:
swYw
L"- 4
c)
k'J64" NTOLEDO, J'
ST,RUr.TURQ EER
�'�.
DRAWN
0
GM
0
JAT
c, -,., *:
DATE
k
03.04.09
SCALE
As Indicated
•
JOB NO.
ry
SHEET
$
E -1
OF
SHEE'�
C.0
•
•
t
�
.
i
i
.
Lo
•
REVISIONS:
swYw
L"- 4
c)
k'J64" NTOLEDO, J'
ST,RUr.TURQ EER
�'�.
DRAWN
GM
CHECKED
JAT
c, -,., *:
DATE
k
03.04.09
SCALE
As Indicated
JOB NO.
SHEET
$
E -1
OF
SHEE'�