Loading...
09-636-0076S M 5S TB (SEE PLAN AND SCHEDULE) TS SQUARE STEEL COL. SEE PLAN FOR ADD. INFO.) SECTION 3/4" = I'-a' 6S Simpson A35 framing anchor (FL# 10446.4) with (6) 8d nails into each member. (or (3) 1/4 x 1.75' embed. Tapcons into concrete.) PRESSURE TREATED 2x8 - (IF RQD. TO MATCH ELEV.) 3E 1� E I—' SEE ARCH. DWGS. FOR ROOF SLOPE SEE ARCH. DWGS. FOR ROOF SLOPE 141 SEE ROOF PLAN FOR STRAP REQUIREMENTS PL5 /8 x 7 x 0' -7' WITH (2) 3/4!'x 8" HEADED STUDS BUTT WELDED TO PLATE 5S 7S 2 STRAPS REQUIRED AT TRUSS GIRDERS WALL SECTI.ON @ EXIST. WALL 3/4" =1- " 2x WOOD NAILER WITH 16d NAILS INTO EXIST. SHEATHING @ 4" o.c. NAIL NEW SHEATHING WITH 10d @ 4" o.c. Provide 12" dia. openings in existing roof sheathing for ventilation at 48" o.c. e.w. 3S PRE -FAB PIGGY -BACK TRUSSES AT 24" O.C. (TYP.) Hughes RT1618 TW strap tie (Miami -Dade County product approval no. 00-1218.03) with �61 1,00 ti 5 NO SILO 01 BUSS Otto X61 100 nails into We of each exist, intersecting truss (max. 2"-T o.4 Penetrate existing sheathing only as required for installation of strap. SEE ROOF PLAN FOR LOCATIONS � D ACK TRUSSE! 3/4" 5S COLUMN SCHEDULE Contractor shall verify all existing conditions in the field. All discrepancies shall be reported to a/e before proceeding with the work. EE] REINFORCEMENT 2E MARK SIZE REMARKS VERTICAL TIES F5"EJ Existing plywood roof sheathing. 6E SC1 8" x 8" 2 #5 NONE 8x8 CONCRETE STARTER COLUMN SC2 8" x 12" 4 #5 #3 @ 8" O.C. 8x12 CONCRETE STARTER COLUMN C1 8" x 12" 4 #5 1 #3 @ 8" Q.C. CONCRETE COLUMN COLUMN NOTES: 1. HOOKED DOWELS, SAME SIZE AND NUMBER AS VERTICAL REINFORCEMENT, SHALL BE EMBEDDED TO BOTTOM OF FOOTING BELOW AND SHALL LAP MINIMUM 30 BAR DIAMETERS WITH VERTICAL REINFORCEMENT IN COLUMNS. 2. HOOK ALL VERTICAL COLUMN REINFORCEMENT AT TOP. 3, WHERE COLUMNS BEGIN FROM EXISTING CONSTRUCTION, DRILL 6" INTO EXISTING CONCRETE ABOVE AND BELOW AND SET 2 #6 x 3'-0" DOWELS FOR SC2 AND C1 AND 1 #5 x 3`-0" DOWELS SC1. 4. COORDINATE ALL MASONRY OPENINGS WITH ARCHITECTURAL DRAWINGS. BEAM SCHEDULE SIZE TOP OF REINFORCEMENT MARK (INCHES) 8M ELEV. TOP INT, BOTT, STIRRUPS REMARKS B -1 8" x 17' 2 #6 — 2 #6 #3 @ 4" BEAM NOTES: 1. AT ALL BEAM CORNERS AND INTERSECTIONS, PROVIDE 2 #5 L- SHAPED CORNER BARS WITH 30 -INCH LONG LEGS ATTOP AND BOTTOM. 2. HOOK ALL TOP BARS AT ENDS. 3, ALL TOP AND BOTTOM BARS SHALL BE CONTINUOUS. WHERE NECESSARY, LAP SPLICE TOP BARS IN MIDDLE THIRD OF SPAN AND LAP SPLICE BOTTOM BARS AT SUPPORTS. LAP SPLICE SHALL BEMINIMUM 36- INCHES. 4. COORDINATE ALL MASONRY OPENINGS WITH ARCHITECTURAL DRAWINGS. 5. WHERE BEAMS FRAME INTO EXIST. CONSTRUCTION, DRILL 6" AND SET 2 #6 x 3'-0" DOWELS IN EPDXY ADHESIVE, UNLESS OTHERWISE NOTED ON DRAWINGS. ROOF /WIND PRESSURES: ZONE 1 - INTERIOR: - 31.82psf ZONE 2 - EDGE: -44.81 psf ZONE 3 - CORNER: - 70.78psf ZONE WITH a = 4' -8" REFER TO ARCHITECTURAL DRAWINGS FOR ROOF SLOPES, DRAINAGE AND WATERPROOFING. (TYP.) o Lo iv P STRUCTURAL DRAWING NOTES EXISTING CONDITIONS Contractor shall verify all existing conditions in the field. All discrepancies shall be reported to a/e before proceeding with the work. EE] Existing CMU wall to remain. 2E Existing concrete foundation. F3­E_J Existing concrete tie beam. 4E 1 Existing concrete slab on ground. F5"EJ Existing plywood roof sheathing. 6E Existing prefab roof trusses. 2 5.02 (TYP.) (ABOVE AND AT EXPOSED CEILING BELOW) SCALE: /4' = 1' -0" STRUCTURAL DRAWING NOTES NOTED THUSLY ON DRAWINGS XS 1 S El Drill 6" into side of existing concrete beam and set 2 #6 x 36" bars in epoxy adhesive (8" o.c. vertically). 2S Fasten starter column to existing CMU with I" wide x 16 gage corrugated galvanized steel masonry anchors at 16" o.c., embedded in masonry joint and fastened to existing with (1) T diameter x 1.75" embed. Tapcon. 3S Prefabricated piggy -back wood trusses at 24" o.c. (see "General Structural Notes" no. 06176 and seciton 3/S.02 for additional information). 4S Fasten truss to existing tie beam with (1) USP RT18 strap (N.O.A. no, 00- 1912.05) with (14) 16d nails into truss and (3) 1/4 "dia. x 1.75" embed. Tapcons into beam (3" spacing). (UPLIFT 1020 #) SS Plywood roof sheathing (see "General Structural Notes" no. 06110 for additional information). 6S Prefabricated wood trusses at 24" o.c. (see "General Structural Notes" no. 06176 for additional information). 7S Fasten truss to existing tie beam with (2) USP RT18 strap (N.O.A, no. 00- 1912.05) with (14) 16d nails into truss and (3) 1 /4" dia. x 1.75' embed. Tapcons into beam (3" spacing), (UPLIFT 2040 #) 8S Prefabricated wood girder truss (see "General Structural Notes" no. 06176 for additional information). 9S Fasten typical prefab girder /truss to tie beam with Nuvue NVHTA -20H truss anchor (N.O.A. no. 04-0510.03) with (18) 1 O nails into truss thru strap and (6) l Od nails thru seat into side of member. (Uplift =- 3117 #) 1 OS 2x4 cont. lateral wood bracing perpendicular to prefab truss /girder at bottom panel points, max. 8' to 10' o.c. Fasten to top of bottom chord with (2)16d nails. OR 1x3 furring strips at 16" o.c. with (2) 8d nails into each intersection truss /girder. CONTRACTOR SHALL VERIFY AND COORDINATE ALL DIMENSIONS AND EXISTING CONDITIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO COMMENCEMENT OF CONSTRUCTION. OF So sUILDMG , • ..ice► ,� MEMO SSA Ll.S. Structures, Inc. 5- rioi=turcil Enoi ^c°3ers 4444 SW 71 st AVENUE, SUITE 103 MIAMI, FLORIDA 33155 305.665.4555 FAX 305.665.5522 info@usstructuresinc.com CA 8439 UJ t/7 U Z Z o F- W W Q > d ;< O o w L-0 W '° 0 ° � w `L Q to ' `� F- 0 Q Z 0 o 0 ZD Q LF) 0 Q *-o REVISIONS: V. S W. �• "�% s 4 C, ms's ­ STRUGT b lN"E'E' R FL P. 891 DRAWN J.T. CHECKED J.A.T DATE 06.02.09 SCALE As Indicated JOB NO. GMA.09.029 SHEET S002 OF 2 SHEETS