09-636-00312
3 MATCH
EXISTING
ANN 14111119100 ,I
NAILER OVER CONT.2"x r, 4
8" WOOD FASCIA.
Acc a -
tUn p
(MATCH
EXIST.)
N EW 7/16" EXT. GRADE PLYWOOD
PAINTED TO MATCH EXISTING
NEW STUCCO FINISH OVER
NEW CONCRETE TIE BEAM
NEW FLAT CEMENT TILE ROOF TO BE
SELECTED BY OWNER OVER 1 LAYER OF #
30 FELT W/ 12 GAUGE RINGSHANKED NAILS
W/ 32 GAUGE TIN -CAPS @ O.C. & 6' O.C. @
OVERLAP. (SEE STRUCT. DWGS) (TYP.)
NEW WOOD TRUSSES @ 24' O.C.
(SEE STRUCTURAL DRAWINGS)
NEW R -30 BATT.
INSULATION.
EL. =8'-0"
TOP OF TIE BM.
2:
CEILING: 5/8" PLYWOOD SHEATHING OVER
1'X3" P.T. WD. NAILERS AT 16" O.C. W/ R-30
INSUL.. TYPICAL UNLESS OTHERWISE NOTED.
H
NEW CONCRETE TIE BEAM
=
CD
(SEE STRUCTURAL DRAWINGS)
Lu
.
Ir-
s
O
EXISTING CONCRETE COLUM 60
m
TO REMAIN (BEYOND)
z
•
F—
4444 SW 71st AVENUE, SUITE 103
cxx/)
W
EXISITNG CONC. SLAB TO REMAIN AS IS
EL. = 0'-0"
(EXISTING FIN. FLR.
ELEV. @ RESIDENCE)
EXISTING CONCRETE FOOTING TO REMAIN
ALL NEW CONSTRUCTION SHALL HAVE PRE - CONSTRUCTION TREATMENT PROTECTION AGAINST SUBTERRANEAN
TERMITES IN ACCORDANCE WITH THE RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF
AGRICULTURE AND CONSUMER SERVICES. A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING
DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT; "THE AREA
OF WORK HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES.
TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF
AGRICULTURE AND CONSUMER SERVICES AS PER F.B.C. 2007
TYPICAL WALL SECTION
SCALE: 3/4" = V -0"
REMOVE PORTIONS OF EXISTING CONCRETE
BLOCK WALL FROM EXTERIOR AS REQUIRED
TO PROVIDE NEW CONCRETE COLUMNS
(TYP.) (SEE STRUCTURAL DRAWINGS)
(EXISTING)
Z Existing
Family Room
u5
qjExisfing
iil Bedroom
Z Existing
Cn Bedroom 3
(EXISTING)
18'-8"
18'-4"
4' -5"
Exist.
Entry
2'-6" �1'4r" 6-0' 1'-0" 2'-6"
f
10' -5" 1- 10' -4"
•
NEW STEEL COLUMN (SEE
STRUCTURAL DRAWINGS)
�4
r
E
REF
KEY NOTES
Existing concrete block wall to remai as is.
Ceiling: 5/8" Plywood sheathing over 1)T P.T. wd. milers
at 16' o.c. w/ R -30 insuL. Typical unless otherwise noted.
Floor: Exsi6ng 4' thick conrete slab on well compacted fill to
remain as is. Typical unless otherwise noted.
NOTES:
PROVIDE ONE COAT OF PRIMER & TWO COATS OF PAINT ON
ALL NEW EXTERIOR TRIMS, WALLS, AND CEILINGS. COLORS
TO BE SELECTED BY OWNER.
Existng
Master
Bedroom
F" Y OF
. � o
-s-IMA
(EXISTING)
Floor Plan
SCALE: 1/4' = 1'-0'
■
J
•
2:
�_
•
.
Ir-
U.&-. Struc!ures. Inc.
.•
•
4444 SW 71st AVENUE, SUITE 103
0
MIAMI, FLORIDA 33155
•
305.665.4555 FAX 305.665.5522
•
info@usstructuresinc.com
-
CA 8439
■
J
•
2:
�_
•
.
Ir-
.•
•
0
•
i
•
•
ry
-
fa
r
•
t
r
:
•
LO
•
REVISIONS:
SEAL:'
Vfi
JO4ErA,'4bgbpr, P.E. •``
STRUCTURA'EN1A ''
FL P.E. #54891