Loading...
13-1262-010MANUAL BALANCING 45 DEGREE BOOT PITTING DAMPER (TYP_) RADIUS ELLS _\ MAY BE USED IN LIEU OF SQUARE ELLS a la: N.T.5. NOTE: 1. HANG DUCTS ACCORDING TO SMACNA STANDARDS 2. HANGER CONSTRUCTION AND SIZING SHALL BE PER SMACNA STANDARDS. TYPICAL Z BAR AND WIRE DUCT HANGING DETAIL TYPICAL HANGING T STRAP AND TYPICAL SADDLE CHANNEL AND STRAP DUCT HANGING DETAIL UPPER ATTACHMENT PER SMACNA FLEXIBLE DUCT- — S' -0" MAX. 2' -0" MIN. LENGTH MAXIMUM D/8 OFFSET ALLOWED IN LAST D INCHES TO DEVICE WHERE D IS THE INTERNAL FLEX DIAMETER NECK SIZE TO MATCH FLEX DUCT SIZE INDICATED (SEE PLANS) a MAX. SAG L2" PER FOOT BETWEEN SUPPORT POINTS DUCT SEALER AT 45' TAKEOFF- OR ROUND BELLMOUTH COLLAR CONNECTION TO MAIN SPIN IN FITTING WITH VOLUME CONTROL DANDER, INSULATE. MOUNT IN SIDE OF DUCT ADJUSTABLE CLAMP SADDLE 22 GUAGE GALVINIZED STEEL STRAP HANGER AS PER SMACNA FIG. 3 -10 ADJUSTABLE CLAMP DUCT SEALER INSULATE TOP PANEL OF DIFFUSER OR GRILLE AIR DISTRIBUTION CEILING FINISH DEVICE LAY -IN SHOWN. (T -BAR SHOWN GYP. SURFACE MOUNT SIMILAR BD. SIMILAR) Y, 1 sca Ia: SUPPLY AIR DUCT VOLUME DAMPER W/ LOCKING QUADRANT 4 2" STANDOFF FULLY HINGED 4 GASKETED ACCESS DOOR FOR DAMPERS IN NON - ACCESSIBLE CEILINGS NOTG: 1. FLEXIBLE DUCTS SHALL BE ONE PIECE AND SHALL NOT BE SPLICED TOGETHER 2. EXTEND FLEXIBLE DUCT INSULATION TO DUCT/DIFFUSER PANEL INSULATION AND SEAL WITH MASTIC. 3.FLEXI5LE AIR DUCT SHALL NOT EXCEED 12 FT. WHEN EXTENDED. ELBOW RADIUS SIZED FOR NO LESS THAN R / D = 1.0 . PROVIDE w" RODS 4 VIBRATION ISOLATORS, SEAL DUCTWORK AIR — (4 REQUIRED) TIGHT FROM DISCHARGE OF FAN TO DISCHARGE LOUVER EXHAUST DUCTWORK W/TRANSITIONS AS REQUIRED (TYPJ IN -LING PAN AIR PLOW MOTOR OUT OF AIRSTREAM Ef� FLEXIBLE CONNECTION (TYP.) m CD METHODS OF HA GOING DUCT DTL. 0>0­446, Sca Ia: N.T.S. Sca Ia: N.T.S. ROUTE HOT WATER PIPES THRU CONCRETE BLOCK WALL IN 4 ", SCHEDULE 40 PVC CONDUIT. PROVIDE WATER PROOF SEALANT AT WALL PENETRATIONS TO PREVENT THE INTRUSION OF INSECTS AND RODENTS. ALSO APPLY THE SEALANT ALONG ENTIRE PERIPHERY OF SHROUD INTERFACE WITH WALL AND AT BOTTOM OPENING OF SHROUD. SHEET METAL SHROUD SECURED TO WALL WITH SELF TAPPING GALV STEEL CONCRETE SCREWS SPACE 24" ON CENTER SHROUD SHALL BE PAINTED TO MATCH COLOR OF BUILDING. PROVIDE WATER PROOF SEALANT AT SHROUD OPENING TO PREVENT THE INTRUSION OF INSECTS AND RODENTS, HOT WATER PIPES FROM HRU, PIPES SHALL BE INSULATED W/ 3/4" THICK ELASTOMERIC FOAM. to = m'r Sca Ia. N.T.S. r r O ~ ff STRUCTURAL CHANNEL 45' TAKEOFF . N.T.S. REFRIGERANT PIPES, LIQUID L NE SHALL B INSULATED W/ 3/4" TF ELASTOMERIC FOAM. TYP. CONDENSING —j UNIT (CU) f Sca Ia: N: Sca Ia: N.T.S. m SHEET HANGERS OR STRAP TO STRUCTURE / r r r r r fJ® r f l ®� r f f r r if r f0 f ff SHEET METAL MAIN SUPPLY TRUNK WALL STRUCTURE TYPICAL TRANSITION MAX. 20' ANGLE GALVANIZED DRAIN PAN WITH FLOAT SWITCH WIRED TO SHUT DOWN A.H.U. VOLUME DAMPER W/ LOCKING DEVICE SHEET METAL BRANCH DUCT SUPPLY AIR DUCT PROVIDE 1 -HR FIRE CONDENSATE DRAIN LINE. DAMPER AT FLOOR SEE FLOOR PLAN FOR PENETRATION (TYP-) ROUTING AND CONDESATE PIPING DETAIL FOR SIZING. NOTE; I. PROVIDE A MINIMUM OF 4" SERVICE/MAINTENANCE AREA AROUND AIR HANDLING UNIT. 2. PROVIDE FLOAT SWITCH IN DRAINPAN WIRED TO SHUT DOWN A/C UNIT IN CASE OF CONDENSATE STOPPAGE. RUN REFRIGERANT LINES THRU CONCRETE BLOCK WALL IN 4 ", SCHEDULE 40 PVC CONDUIT. PROVIDE WATER PROOF SEALANT AT WALL PENETRATIONS. SHEET METAL SHROUD SECURED TO WALL WITH GALV. CONCRETE SCREWS SPACE 24" ON CENTER SHROUD SHALL BE PAINTED TO MATCH COLOR OF BUILDING. 4" THICK PRE -PA15 CONCRETE PAD 4" LARGER THAN CU ON ALL SIDES. TOP OF PAD SHALL BE MOUNTED MINIMUM 611 BELOW TOP OF FINISHED FLOOR FLOOR SLAB AND ABOVE THE FLOOD HARZARD LEVEL, MOUNT CONDENSING UNIT ON P THICK NEOPRENE VIBRATION PADS. SECURE UNIT WITH ANGLE BRACKETS (GALV) AND GALV SELF TAPPING CONCRETE SCREWS AND WASHERS AT 12" ON CENTER ON ALL FOUR (4) SIDES. VERTICAL AIR I HANDLER UNIT I 12 = ='r"g:` t" Sca Ia: N.T.S. H.V.A.C. TYPICAL DETAILS