1. FURNISH ALL LABOR, MATERIALS, EQUIPMENT, PERMITS FEES, INSPECTIONS, TESTS,
INSURANCE, ETC., REQUIRED FOR THE COMPLETION OF THE AIR CONDITIONING SYSTEM,
SHOWN ON THE DRAWINGS AND OR LISTED BELOW.
2. LOW VELOCITY DUCTWORK SHALL BE R -6 (MIN-), 1 -1/2 " THICK, K -VALUE 023, RIGID, FOIL FACED
FIBERGLASS DUCT BOARD, JOHNS MANVILLE - SUPERDUCT RC TYPE 415, INSTALLED IN
STRICT ACCORDANCE WITH SMACNA STANDARDS. DUCT SIZES SHOWN ARE "AIRSIDE"
DIMENSIONS. VERIFY EXACT LOCATION OF DUCT WITH RESPECT TO STRUCTURE BEFORE
FABRICATION. MIXING /COLLECTION DUCT PLENUMS SHALL BE OF FIBERGLASS DCUTBOARD.
FIBERGLASS DUCTWORK IS NOT ALLOWED FOR TOILET /CLOTHES DRYER EXHAUST.
3• FLEXIBLE DUCT SHALL BE CONSTRUCTED WITH I" THICK, 1 POUND DENSITY FIBERGLAS, MINIMUM
R -VALUE 43) WITH EXTERIOR VAPOR BARRIER AND A INTERIOR TRILAMINATE MATERIAL
LAMINATED TO A SPIRAL WIRE HELIX TO PROVIDE A DURABLE, AIRTIGHT LAYER BETWEEN
THE FIBERGLASS AND THE AIRSTREAM. MEDIUM PRESSURE TYPE AS MANUFACTURED BY
THERMAFLEX CORPORATION. PROVIDE SPIN COLLAR WITH DAMPER AND EXTRACTOR
4. BATHROOM EXHAUST DUCTS TO BE CONSTRUCTED OF SHEET METAL, (NO T -FIN ALLOWED)
TERMINATED NOT LESS THAN 6 INCHES ABOVE THE FINISH ROOF SURFACE, BE EQUIPPED
WITH A BACKDRAFT DAMPER, SCREENED WITH A CORROSION RESISTANT MATERIAL HAVING
HAVING A MESH SIZE NOT LARGER THAN 1/4 INCH. PROVIDE RAIN CAP AT ROOF TERMINATION.
5, KITCHEN/DRYER EXHAUST DUCTS TO BE CONSTRUCTED OF SHEET METAL, (NO T -FIN ALLOWED).
DUCTS SHALL COMPLY WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS, BE CONSTRUCTED
OF A MINIMUM 26 GAUGE METAL PIPE, HAVING A SMOOTH INTERIOR SURFACE WITH JOINTS
RUNNING IN THE DIRECTION OF THE AIR FLOW. DUCT JOINTS SHALL NOT BE ASSEMBLED WITH
SHEET METAL SCREWS OR OTHER FASTENERS WHICH WOULD EXTEND INTO THE DUCT.
TERMINATE DUCT NOT LESS THAN 6 INCHES ABOVE THE FINISH ROOF SURFACE AND FURNISH
WITH A CORROSION RESISTANT CONICAL ROOF CAP. EXHAUST SYSTEM SHALL NOT HAVE ANY
DAMPERS AND /OR SCREENING.
6. INWI.ATION:
PIPING - CONDENSATE PIPING AND REFRIGERATION SUCTION PIPING SHALL BE
INSULATED WITH MINIMUM 3/4" AMCOAFLEX ( "ELASTOMERIC FOAM ").
-1. ALL REGISTERS, GRILLES, DIFFUSERS, AND LOUVERS SHALL BE TITUS (SUPPLY- MDL. 250 -AA,
RETURN: MDL. 350FL) OR ARCHITECT APPROVED EQUIVALENT.
8. TEMPERATURE CONTROL SHALL BE A'1-DAY PROGRAMMABLE ELECTRONIC ROOM
THERMOSTAT FOR HEATING /COOLING WITH 2 STAGES OF NEAT /COOLING AS REQUIRED,
WITH AUTOMATIC CHANGEOVER AS MANUFACTURED BY TYLER (MDL. •: TAY6TAT302C)
OR APPROVED EQUIVALENT.
9, CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS AND TESTING.
10. rl>_TeRS:
A. PROVIDE TWO SETS OF TEMPORARY, PLEATED MEDIA, FIBERRGLASS THROWAWAY FILTERS
OF THE SAME THICKNESS AS FINAL FILTERS FOR USE DURING CONSTRUCTION.
B. AIR CONDITIONING FAN COIL UNITS SHALL HAVE ONE INCH THICK, PLEATED MEDIA,
THROWAWAY TYPE FIBERGLASS FILTERS.
C. PROVIDE TWO COMPLETE SETS OF FINAL FILTERS.
11. GUARANTEM.
A. ALL COMPRESSOR MOTORS ON NEW EQUIPMENT FURNISHED UNDER THIS
CONTRACT SHALL HAVE A 5 YEAR PRODUCT GUARANTEE FROM DATE OF
START -UP.
B. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE
FROM DEFECTS FOR A PERIOD OF NOT LESS THAN 1 YEAR FROM DATE OF
ACCEPTANCE.
12. TRSTING:
A. ALL REFRIGERANT HIGH SIDE PIPING TO 3GG PSIG. LOW SIDE TO 150 PSIG.
AFTER TESTING EVACUATE SYSTEM TO 200 MICRONS WITH VACUUM PUMP. HOLD
FOR 25 HOURS WITH PUMP OFF BREAK VACUUM WITH REFRIGERANT.
B. BALANCE AIR SYSTEM TO DELIVER QUANTITIES AT EACH OUTLET WITHIN 5
PERCENT USING A.A.B.C. PROCEDURES AND TESTS. SUBMIT AIR BALANCE TEST
RESULTS FOR REVIEW PRIOR TO FINAL INSPECTION.
13. VIBRATION ISOLATION: ALL EQUIPMENT AS PER MANUFACTURER RECOMMENDATIONS TO
ELIMINATE ANY EQUIPMENT NOISE FROM BEING HEARD.
14. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH
THE PROGRESS OF CONSTRUCTION AND IN STRICT COMPLIANCE WITH ALL APPLICABLE
CODES AND STANDARDS.
15. VERIFY ALL VOLTAGES WITH ELECTRICAL CONTRACTOR BEFORE ORDERING ANY
EQUIPMENT.
16. ELECTRIC HEATERS SHALL BE U.L. LISTED, BLAST COIL DESIGN AS PER N.E.C. COMPLETE
WITH GALVANIZED STEEL FRAME SOLID TERMINAL BOX COVER AND TOTALLY ENCLOSED
TERMINAL BOX. BRANCH FUSES FOR ALL ELEMENTS OVER 48 AMPS, AUTO RESET
THERMAL CUT -OFF, HEAT LIMITERS, FUSED DISCONNECT. AIR FLOW PROVING DEVICE,
CONTROL TRANSFORMER WHERE REQUIRED FOR 12OV, FOR CONTROL VOLTAGE.
11. VERIFY ALL DIMENSIONS WITH STRUCTURE PRIOR TO ANY FABRICATION OR INSTALLATION.
16. SUBMIT SHOP DRAWINGS OF ALL MATERIALS AND EQUIPMENT FOR APPROVAL PRIOR TO
FABRICATION
19, PRIOR TO COMMENCEMENT OF WORK, VERIFY MEASUREMENTS AT BUILDING SITE. SUBMIT
DISCREPANCIES AND DIFFERENCES TO ARCHITECT - ENGINEER FOR CONSIDERATION AND
DECISION BEFORE PROCEEDING.
20. OBTAIN FULL INFORMATION REGARDING PECULIARITIES AND LIMITATIONS OF SPACE
AVAILABLE FOR INSTALLATION OF THE EQUIPMENT AND MATERIALS UNDER CONTRACT,
AND PROVIDE READY ACCESSIBILITY TO DAMPERS, VALVES, AND OTHER APPARATUS,
INCLUDING ANY PART OF SYSTEM REQUIRED TO BE REACHED FOR MAINTENANCE AND
OPERATIONS,
21. PROVIDE AN ACCURATE LAYOUT, GRADES, AND ELEVATIONS, SET SLEEVES AND
OPENINGS IN AMPLE TIME, AND TAKE PROPER PRECAUTIONS TO PROTECT WORK AND
EQUIPMENT FROM DAMAGE.
22. CUT ALL OPENINGS AND CHASES REQUIRED TO ACCOMMODATE THE WORK UNDER THIS
DIVISION, AND REPAIR ALL FLOORS, WALLS, ETC. DAMAGED BY SUCH CUTTINGS. ALL
WORK DONE UNDER THIS HEADING MUST CONFORM IN EVERY RESPECT TO FINISH AND
QUALITY OF MATERIALS AND WORKMANSHIP OF THE INDUSTRY STANDARD.
23. ALL REFRIGERANT PIPING SHALL BE TYPE "K" HARD COPPER, TOGETHER WITH WROUGHT
COPPER SOLDER FITTINGS. JOINTS SHALL BE MADE WITH SILVER SOLDER OR "SILFOS ".
ALL CONDENSATE DRAIN PIPING TO BE SCHEDULE 40 TYPE II HIGH IMPACT PVC WITH
SLIP JOINT FITTINGS OF THE SAME MATERIALS WITH AN APPROVED SOLVENT INSTALLED
IN A MANNER RECOMMENDED BY THE FITTING MANUFACTURER-
24. FLEXIBLE DUCT SHALL BE SELF- SUPPORTING ALUMINUM CONSTRUCTION WITH 1" THICK
BLANKET TYPE INSULATION WITH EXTERIOR VAPOR BARRIER, HIGH PRESSURE TYPE AS
MANUFACTURED BY CLEVEPAK CORPORATION. PROVIDE SPIN COLLAR WITH DAMPER AND
EXTRACTOR AS MANUFACTURED BY CLEVEPAK CORPORATION WHERE FLEXIBLE DUCT IS
CONNECTED TO RECTANGULAR DUCTWORK
25. ALL EQUIPMENT SUPPORTS, PIPING SUPPORTS, DUCT SUPPORTS, AND ROOF PENETRATIONS
SHALL BE DONE IN A MANNER ACCEPTABLE TO THE ARCHITECT/ENGINEER
EXISTIN(S RESIDENCE
► PROPOSED NEW ADDITION �
II �
f �
1
a_
d)
I a
I �
!xU
I
Alj�ATE DRAIN LINEoO
3' APR AND
THM EXTERIOR WALL.
PRC DE 2' MIN. P -TRAP
FOR CONDENSATE DRAMS
• EXMWOR OF ISUILDMG.
NIEUI / RELOCATED
A/C AIR - COOLED
CONDENSING UNIT pj
(CU -1) SECURED U
ON CONC. PAD
THRI.1 VIE5RATION
ISOLATION.
RUN RS/RL PIPES FULL
SIZE THRU EXTERIOR
WALL 4 LIP TO CEILING
SPACE AND SEAL WALL.
PROVIDE INSULATION
FOR ENTIRE LENGTH OF
CONDENSATE PIPING
WITHIN CEILING SPACP. �j
X
111
eC ,4L EE: 1/4" = V-0>11
AIR CONDITIONING
SYSTEMS SCHEDULE
Z
AIR- COOLED COND. UNIT
TRANS OR APPROVED EQUAL
SYSTEM
UNIT
NO
CAPACITY
C.F.M
WEIGHT
LBS.
E.S.P.
IN
H.2.0
H.P.
a
ELECTRIC
HEATING
MODEL
NUMBER
0
REFRIG PIPE
MODEL
NO.
4
CAPACITY
ELEC.
(V /PH)
SEER
ENTERING
WB' /DB-
LEAVING
WB' /DB-
SUC.
LIQ.
Z
STAGE
12'0 X 24' DEEP
L.R.A.
TOTAL
CLAY OR CONK.
DRY1LIE L FILLED
AHU -1
UV- s4' GRAVEL.
2000
290
2
1.0
6.9
10
Q
�1 I
28.8
152.8
7/8
3/8
DS=6 -06018
60.0
57.0
426
NIEUI / RELOCATED
A/C AIR - COOLED
CONDENSING UNIT pj
(CU -1) SECURED U
ON CONC. PAD
THRI.1 VIE5RATION
ISOLATION.
RUN RS/RL PIPES FULL
SIZE THRU EXTERIOR
WALL 4 LIP TO CEILING
SPACE AND SEAL WALL.
PROVIDE INSULATION
FOR ENTIRE LENGTH OF
CONDENSATE PIPING
WITHIN CEILING SPACP. �j
X
111
eC ,4L EE: 1/4" = V-0>11
AIR CONDITIONING
SYSTEMS SCHEDULE
AIR HANDLING UNIT
TRANE OR APPROVED EQUAL
AIR- COOLED COND. UNIT
TRANS OR APPROVED EQUAL
SYSTEM
UNIT
NO
CAPACITY
C.F.M
WEIGHT
LBS.
E.S.P.
IN
H.2.0
H.P.
F.L.A.
ELECTRIC
HEATING
MODEL
NUMBER
COMPRESSOR
REFRIG PIPE
MODEL
NO.
MOCP
(AMPS)
CAPACITY
ELEC.
(V /PH)
SEER
ENTERING
WB' /DB-
LEAVING
WB' /DB-
SUC.
LIQ.
KW
STAGE
RLA
L.R.A.
TOTAL
SENS
AHU -1
5.0
2000
290
0.5
1.0
6.9
10
2
A%PTM
28.8
152.8
7/8
3/8
DS=6 -06018
60.0
57.0
426
240/1
15.5
80.0/87.0
58.0/55.8
Z ALL EXHAUST FANS TO BE EQUIPT WITH BACKDRAFT DAMPERS.
1 ALL EXHAUST OUTLETS THRU ROOF AND WALLS TO HAVE A RAINCAP AND INSECT SCREEN
4. PROVIDE FAN SELECTION FOR A MAXIMUM NOISE GENERATION OF 1.2 SONES.
AIR HANDER UNIT NOTES:
1. PROVIDE CUSTOMER WITH FPL REBATES FOR SEER LISTED IN SCHEDULE
2. SYSTEMS SHALL BE OF REFRIGERANT TYPE R -410A
1. AR HANDLERS SHALL BE OF AIR -TIGHT CONSTRUCTION.
4. CONDENSING UNITS TO BE PROVIDED FOR OPERATION WITH HEAT RECOVERY UNIT FOR HOT WATER HEATER
5 AHU do CU SHALL BE RATED FOR OPERATION AS A SYSTEM ST THE MANUFACTURER.
EXHAUST
FAN
SCHEDULE
- CEILING DIFFUSER ROUND NECK
177& (CEILING DIFFUSERS ARE 4 -WAY
THROW UNO)
LABEL
TYPE OF UNIT -AREA SERVED
MANUFACTURER &
CFM
SP
MOUNTING ARRANGEMENT
MOTOR H.P.
RPM
ELEC
NOTES
- CEILING DIFFUSER, ONE -WAY THROW,
ARROW INDICATES DIRECTION OF
AIR THROW,
MODEL NUMBER
- CEILING DIFFUSER TWO -WAY CORNER
-- THROW, ARROWS INDICATE DIRECTION
OF AIR THROW.
- CEILING DIFFUSER, TWO -WAY THROW,
ARROWS INDICATE DIRECTION OF AIR
THROW.
!WATTS}
- CEILING DIFFUSER THREE -WAY THROW,
- ARROWS INDICATE DIRECTION OF AIR
THROW.
f
(V/PH)
EF -1
NEW/ MODELED MASTER BATH
GREENHECK
SP -B150
75
0.40
IN C LING
p. 129 (W)
1050
1t5 /f
2,3
1..4
EF -2
NEW POWDER ROOM
GREENHECK SP-Btta
50
0.40
IN CEILING
80 (W)
648
115/1
1.2,3.4
EXHAUST FAN NOTES
1. FURNISH WITH MANUFACTURER PROVIDED SPEED CONTROLLER. ISOLATION HANGERS, BACKDRAFT DAMPER AND DISCONNECT SWITCH.
Z ALL EXHAUST FANS TO BE EQUIPT WITH BACKDRAFT DAMPERS.
1 ALL EXHAUST OUTLETS THRU ROOF AND WALLS TO HAVE A RAINCAP AND INSECT SCREEN
4. PROVIDE FAN SELECTION FOR A MAXIMUM NOISE GENERATION OF 1.2 SONES.
1. EQUIPMENT CONNECTIONS: ELBOW DOWN t TRANSITION AS
REQUIRED TO MAKE UNIT CONNECTION- PROVIDE FLFX15LE
CONNECTIONS AT DUCTWORG COas[NECTICNS TO EQUIPMENNT
(AHU, FANS, ETC.). _ ry - = n
2. SECURE CONDENSING UNIT ON 4" (MIN-) CONCRETE PAD
THROUGH VIBRATION ISOLATION.
3. UNDERGROUND CONDENSATE DRAIN LINE TO BE 2 11
DIAMETER MINIMUM.
4. ALL EXHAUST DUCTS TO BE CONSTRUCTED OF SHEET METAL,
TERMINATED OUTSIDE THE BUILDING, AND BE EQUIPPED
WITH A BACKDRAFT DAMPER - ( NO T -FIN ALLOWED ).
5. ALL TOILETS / BATHROOMS, NOT HAVING AN OUTSIDE
OPERABLE WINDOW, MUST BE PROVIDED WITH A MECHANICAL
EXHAUST SYSTEM TO PRODUCE 1 COMPLETE AIR CHANGE
EVERY 3 MINUTES, EXCEPT THAT WHERE THE VENTILATING AIR
HAS BEEN CONDITIONED, THERE SHALL BE A COMPLETE AIR
CHANGE EVERY 11/2 MINUTES. - CAN A/C DROP IN A INTERIOR
TOILET / BATHROOM IS NOT SUFFICIENT OR AN ACCEPTABLE
MEANS OF VENTILATION. - AN EXHAUST FAN MUST BE
PROVIDED -
6. DUCTS FROM TOILETS / BATHROOMS TO BE DISCHARGED TO
THE OUTSIDE OF THE BUILDING, TERMINATED NOT LESS THAN
6 INCHES ABOVE THE FINISH ROOF SURFACE, AND TO BE
SCREENED WITH A CORROSION RESISTANT MATERIAL
HAVING A MESH SIZE NOT LARGER THAN Lz INCH. - (PROVIDE
GOOSE NECK OR RAIN CAP ON ROOF TERMINATIONS)
1- PROVIDE MINIMUM 4" DIAMETER DRYER VENTS FOR
CONNECTION TO CLOTHES DRYER. CORDINATE EXACT SIZE
OF VENT AND LOCATION OF VENT WITH EQUIPMENT TO BE
PURCHASED.
8- CLOTHES DRYER EXHAUST DUCT TO BE A MINIMUM OF 4 INCH
DIAMETER AND SHALL NOT BE SCREENED.
CLOTHES DRYER EXHAUST DUCTS ( OR VENT ) TO COMPLY
WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS, BE
CONSTRUCTED OF A MINIMUM 26 GAUGE METAL PIPE, HAVING
A SMOOTH INTERIOR SURFACE WITH JOINTS RUNNING IN THE
DIRECTION OF THE AIR FLOW. DUCT JOINTS MUST NOT BE
ASSEMBLED WITH SHEET METAL SCREWS OR OTHER
FASTENERS WHICH WOULD EXTEND INTO THE DUCT.
10. TYPICALLY PROVIDE A UNRESTRICTED 1 INCH UNDERCUT FOR
ALL ENCLOSED ROOF 1 DOORS TO ASSIST IN ACHEIVING A
PROPER RETURN AIR BALANCE.
IGEY NOTES.
1. NEW / RELOCATED AIR HANDLER UNIT (AHU). RELOCATE
AND /OR MODIFY EXISTING REFRIGERANT / CONDENSATE
PIPING AND DUCTWORK AS REQUIRED TO ACCOMMODATE
NEW LAYOUT / REMODELED PLANS.
2. NEW / RELOCATED AIR CONDITIONING CONDENSING UNIT
(ACLU). RELOCATE AND /OR MODIFY EXISTING REFRIGERANT
/CONDENSATE PIPING AS REQUIRED TO ACCOMMODATE NEW
LAYOUT / REMODELED PLANS.
3. NEW / RELOCATED EXHAUST FAN UNIT (Er-d. INTERLOCKED TO
OPERATE WITH THE LIGHT SWITCH FOR THE TOILET ROOM /
BATHROOM.
•
U.
•
•
• ai
•
a
•
•
s 1
0 �
•
•
a
r»Ir1
s
NUMBER DATE ITEM
SHEET TITLE:
HY.A.C.
FLOOR PLAN
SCHEDULES
AND NOTES
SCALE: SHEET NUMBER:
DATE:
09 -13 -2013
� 1
2411X12" - DUCTWORK, FIRST DIMENSION
-IS SIDE SHOWN
- CEILING DIFFUSER ROUND NECK
177& (CEILING DIFFUSERS ARE 4 -WAY
THROW UNO)
- FLEXIBLE DUCTWORK
I I -SIDE WALL SUPPLY AIR GRILLE
Note: All Existing Ductwork - CEILING RETURN AIR GRILLE,
- EXHAUST FAN Vwm Dashed For Reference ROUND NECK
And Clarity.
L� I p"L4 OR 0411ft
.f.*4 lg:G W L=wc*m111Q1 =
1. ALL CEILING DIFFUSER AIR THROW PATTERNS ARE FOUR -WAY UNLESS OTHERWISE INDICATED ON PLAN DRAWINGS
IN ACCORDANCE WITH THE SYMBOLS SHOWN BELOW
- CEILING DIFFUSER, ONE -WAY THROW,
ARROW INDICATES DIRECTION OF
AIR THROW,
- CEILING DIFFUSER TWO -WAY CORNER
-- THROW, ARROWS INDICATE DIRECTION
OF AIR THROW.
- CEILING DIFFUSER, TWO -WAY THROW,
ARROWS INDICATE DIRECTION OF AIR
THROW.
- CEILING DIFFUSER THREE -WAY THROW,
- ARROWS INDICATE DIRECTION OF AIR
THROW.
f
•
U.
•
•
• ai
•
a
•
•
s 1
0 �
•
•
a
r»Ir1
s
NUMBER DATE ITEM
SHEET TITLE:
HY.A.C.
FLOOR PLAN
SCHEDULES
AND NOTES
SCALE: SHEET NUMBER:
DATE:
09 -13 -2013
� 1
r
it
iM
•
U.
•
•
• ai
•
a
•
•
s 1
0 �
•
•
a
r»Ir1
s
NUMBER DATE ITEM
SHEET TITLE:
HY.A.C.
FLOOR PLAN
SCHEDULES
AND NOTES
SCALE: SHEET NUMBER:
DATE:
09 -13 -2013
� 1