13-1262-009v 0 I i tzi W z 0 0 Q 0 N U c v .v cn v v �U U-1 0 Q_ .11 E CL rn I r2 N a O Z U cs v 4� c v e IN mic4TION&V SPEC lr 1. FURNISH ALL LABOR, MATERIALS, EQUIPMENT, PERMITS FEES, INSPECTIONS, TESTS, INSURANCE, ETC., REQUIRED FOR THE COMPLETION OF THE AIR CONDITIONING SYSTEM, SHOWN ON THE DRAWINGS AND OR LISTED BELOW. 2. LOW VELOCITY DUCTWORK SHALL BE R -6 (MIN-), 1 -1/2 " THICK, K -VALUE 023, RIGID, FOIL FACED FIBERGLASS DUCT BOARD, JOHNS MANVILLE - SUPERDUCT RC TYPE 415, INSTALLED IN STRICT ACCORDANCE WITH SMACNA STANDARDS. DUCT SIZES SHOWN ARE "AIRSIDE" DIMENSIONS. VERIFY EXACT LOCATION OF DUCT WITH RESPECT TO STRUCTURE BEFORE FABRICATION. MIXING /COLLECTION DUCT PLENUMS SHALL BE OF FIBERGLASS DCUTBOARD. FIBERGLASS DUCTWORK IS NOT ALLOWED FOR TOILET /CLOTHES DRYER EXHAUST. 3• FLEXIBLE DUCT SHALL BE CONSTRUCTED WITH I" THICK, 1 POUND DENSITY FIBERGLAS, MINIMUM R -VALUE 43) WITH EXTERIOR VAPOR BARRIER AND A INTERIOR TRILAMINATE MATERIAL LAMINATED TO A SPIRAL WIRE HELIX TO PROVIDE A DURABLE, AIRTIGHT LAYER BETWEEN THE FIBERGLASS AND THE AIRSTREAM. MEDIUM PRESSURE TYPE AS MANUFACTURED BY THERMAFLEX CORPORATION. PROVIDE SPIN COLLAR WITH DAMPER AND EXTRACTOR 4. BATHROOM EXHAUST DUCTS TO BE CONSTRUCTED OF SHEET METAL, (NO T -FIN ALLOWED) TERMINATED NOT LESS THAN 6 INCHES ABOVE THE FINISH ROOF SURFACE, BE EQUIPPED WITH A BACKDRAFT DAMPER, SCREENED WITH A CORROSION RESISTANT MATERIAL HAVING HAVING A MESH SIZE NOT LARGER THAN 1/4 INCH. PROVIDE RAIN CAP AT ROOF TERMINATION. 5, KITCHEN/DRYER EXHAUST DUCTS TO BE CONSTRUCTED OF SHEET METAL, (NO T -FIN ALLOWED). DUCTS SHALL COMPLY WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS, BE CONSTRUCTED OF A MINIMUM 26 GAUGE METAL PIPE, HAVING A SMOOTH INTERIOR SURFACE WITH JOINTS RUNNING IN THE DIRECTION OF THE AIR FLOW. DUCT JOINTS SHALL NOT BE ASSEMBLED WITH SHEET METAL SCREWS OR OTHER FASTENERS WHICH WOULD EXTEND INTO THE DUCT. TERMINATE DUCT NOT LESS THAN 6 INCHES ABOVE THE FINISH ROOF SURFACE AND FURNISH WITH A CORROSION RESISTANT CONICAL ROOF CAP. EXHAUST SYSTEM SHALL NOT HAVE ANY DAMPERS AND /OR SCREENING. 6. INWI.ATION: PIPING - CONDENSATE PIPING AND REFRIGERATION SUCTION PIPING SHALL BE INSULATED WITH MINIMUM 3/4" AMCOAFLEX ( "ELASTOMERIC FOAM "). -1. ALL REGISTERS, GRILLES, DIFFUSERS, AND LOUVERS SHALL BE TITUS (SUPPLY- MDL. 250 -AA, RETURN: MDL. 350FL) OR ARCHITECT APPROVED EQUIVALENT. 8. TEMPERATURE CONTROL SHALL BE A'1-DAY PROGRAMMABLE ELECTRONIC ROOM THERMOSTAT FOR HEATING /COOLING WITH 2 STAGES OF NEAT /COOLING AS REQUIRED, WITH AUTOMATIC CHANGEOVER AS MANUFACTURED BY TYLER (MDL. •: TAY6TAT302C) OR APPROVED EQUIVALENT. 9, CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS AND TESTING. 10. rl>_TeRS: A. PROVIDE TWO SETS OF TEMPORARY, PLEATED MEDIA, FIBERRGLASS THROWAWAY FILTERS OF THE SAME THICKNESS AS FINAL FILTERS FOR USE DURING CONSTRUCTION. B. AIR CONDITIONING FAN COIL UNITS SHALL HAVE ONE INCH THICK, PLEATED MEDIA, THROWAWAY TYPE FIBERGLASS FILTERS. C. PROVIDE TWO COMPLETE SETS OF FINAL FILTERS. 11. GUARANTEM. A. ALL COMPRESSOR MOTORS ON NEW EQUIPMENT FURNISHED UNDER THIS CONTRACT SHALL HAVE A 5 YEAR PRODUCT GUARANTEE FROM DATE OF START -UP. B. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN 1 YEAR FROM DATE OF ACCEPTANCE. 12. TRSTING: A. ALL REFRIGERANT HIGH SIDE PIPING TO 3GG PSIG. LOW SIDE TO 150 PSIG. AFTER TESTING EVACUATE SYSTEM TO 200 MICRONS WITH VACUUM PUMP. HOLD FOR 25 HOURS WITH PUMP OFF BREAK VACUUM WITH REFRIGERANT. B. BALANCE AIR SYSTEM TO DELIVER QUANTITIES AT EACH OUTLET WITHIN 5 PERCENT USING A.A.B.C. PROCEDURES AND TESTS. SUBMIT AIR BALANCE TEST RESULTS FOR REVIEW PRIOR TO FINAL INSPECTION. 13. VIBRATION ISOLATION: ALL EQUIPMENT AS PER MANUFACTURER RECOMMENDATIONS TO ELIMINATE ANY EQUIPMENT NOISE FROM BEING HEARD. 14. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION AND IN STRICT COMPLIANCE WITH ALL APPLICABLE CODES AND STANDARDS. 15. VERIFY ALL VOLTAGES WITH ELECTRICAL CONTRACTOR BEFORE ORDERING ANY EQUIPMENT. 16. ELECTRIC HEATERS SHALL BE U.L. LISTED, BLAST COIL DESIGN AS PER N.E.C. COMPLETE WITH GALVANIZED STEEL FRAME SOLID TERMINAL BOX COVER AND TOTALLY ENCLOSED TERMINAL BOX. BRANCH FUSES FOR ALL ELEMENTS OVER 48 AMPS, AUTO RESET THERMAL CUT -OFF, HEAT LIMITERS, FUSED DISCONNECT. AIR FLOW PROVING DEVICE, CONTROL TRANSFORMER WHERE REQUIRED FOR 12OV, FOR CONTROL VOLTAGE. 11. VERIFY ALL DIMENSIONS WITH STRUCTURE PRIOR TO ANY FABRICATION OR INSTALLATION. 16. SUBMIT SHOP DRAWINGS OF ALL MATERIALS AND EQUIPMENT FOR APPROVAL PRIOR TO FABRICATION 19, PRIOR TO COMMENCEMENT OF WORK, VERIFY MEASUREMENTS AT BUILDING SITE. SUBMIT DISCREPANCIES AND DIFFERENCES TO ARCHITECT - ENGINEER FOR CONSIDERATION AND DECISION BEFORE PROCEEDING. 20. OBTAIN FULL INFORMATION REGARDING PECULIARITIES AND LIMITATIONS OF SPACE AVAILABLE FOR INSTALLATION OF THE EQUIPMENT AND MATERIALS UNDER CONTRACT, AND PROVIDE READY ACCESSIBILITY TO DAMPERS, VALVES, AND OTHER APPARATUS, INCLUDING ANY PART OF SYSTEM REQUIRED TO BE REACHED FOR MAINTENANCE AND OPERATIONS, 21. PROVIDE AN ACCURATE LAYOUT, GRADES, AND ELEVATIONS, SET SLEEVES AND OPENINGS IN AMPLE TIME, AND TAKE PROPER PRECAUTIONS TO PROTECT WORK AND EQUIPMENT FROM DAMAGE. 22. CUT ALL OPENINGS AND CHASES REQUIRED TO ACCOMMODATE THE WORK UNDER THIS DIVISION, AND REPAIR ALL FLOORS, WALLS, ETC. DAMAGED BY SUCH CUTTINGS. ALL WORK DONE UNDER THIS HEADING MUST CONFORM IN EVERY RESPECT TO FINISH AND QUALITY OF MATERIALS AND WORKMANSHIP OF THE INDUSTRY STANDARD. 23. ALL REFRIGERANT PIPING SHALL BE TYPE "K" HARD COPPER, TOGETHER WITH WROUGHT COPPER SOLDER FITTINGS. JOINTS SHALL BE MADE WITH SILVER SOLDER OR "SILFOS ". ALL CONDENSATE DRAIN PIPING TO BE SCHEDULE 40 TYPE II HIGH IMPACT PVC WITH SLIP JOINT FITTINGS OF THE SAME MATERIALS WITH AN APPROVED SOLVENT INSTALLED IN A MANNER RECOMMENDED BY THE FITTING MANUFACTURER- 24. FLEXIBLE DUCT SHALL BE SELF- SUPPORTING ALUMINUM CONSTRUCTION WITH 1" THICK BLANKET TYPE INSULATION WITH EXTERIOR VAPOR BARRIER, HIGH PRESSURE TYPE AS MANUFACTURED BY CLEVEPAK CORPORATION. PROVIDE SPIN COLLAR WITH DAMPER AND EXTRACTOR AS MANUFACTURED BY CLEVEPAK CORPORATION WHERE FLEXIBLE DUCT IS CONNECTED TO RECTANGULAR DUCTWORK 25. ALL EQUIPMENT SUPPORTS, PIPING SUPPORTS, DUCT SUPPORTS, AND ROOF PENETRATIONS SHALL BE DONE IN A MANNER ACCEPTABLE TO THE ARCHITECT/ENGINEER EXISTIN(S RESIDENCE ► PROPOSED NEW ADDITION � II � f � 1 a_ d) I a I � !xU I Alj�ATE DRAIN LINEoO 3' APR AND THM EXTERIOR WALL. PRC DE 2' MIN. P -TRAP FOR CONDENSATE DRAMS • EXMWOR OF ISUILDMG. NIEUI / RELOCATED A/C AIR - COOLED CONDENSING UNIT pj (CU -1) SECURED U ON CONC. PAD THRI.1 VIE5RATION ISOLATION. RUN RS/RL PIPES FULL SIZE THRU EXTERIOR WALL 4 LIP TO CEILING SPACE AND SEAL WALL. PROVIDE INSULATION FOR ENTIRE LENGTH OF CONDENSATE PIPING WITHIN CEILING SPACP. �j X 111 eC ,4L EE: 1/4" = V-0>11 AIR CONDITIONING SYSTEMS SCHEDULE Z AIR- COOLED COND. UNIT TRANS OR APPROVED EQUAL SYSTEM UNIT NO CAPACITY C.F.M WEIGHT LBS. E.S.P. IN H.2.0 H.P. a ELECTRIC HEATING MODEL NUMBER 0 REFRIG PIPE MODEL NO. 4 CAPACITY ELEC. (V /PH) SEER ENTERING WB' /DB- LEAVING WB' /DB- SUC. LIQ. Z STAGE 12'0 X 24' DEEP L.R.A. TOTAL CLAY OR CONK. DRY1LIE L FILLED AHU -1 UV- s4' GRAVEL. 2000 290 2 1.0 6.9 10 Q �1 I 28.8 152.8 7/8 3/8 DS=6 -06018 60.0 57.0 426 NIEUI / RELOCATED A/C AIR - COOLED CONDENSING UNIT pj (CU -1) SECURED U ON CONC. PAD THRI.1 VIE5RATION ISOLATION. RUN RS/RL PIPES FULL SIZE THRU EXTERIOR WALL 4 LIP TO CEILING SPACE AND SEAL WALL. PROVIDE INSULATION FOR ENTIRE LENGTH OF CONDENSATE PIPING WITHIN CEILING SPACP. �j X 111 eC ,4L EE: 1/4" = V-0>11 AIR CONDITIONING SYSTEMS SCHEDULE AIR HANDLING UNIT TRANE OR APPROVED EQUAL AIR- COOLED COND. UNIT TRANS OR APPROVED EQUAL SYSTEM UNIT NO CAPACITY C.F.M WEIGHT LBS. E.S.P. IN H.2.0 H.P. F.L.A. ELECTRIC HEATING MODEL NUMBER COMPRESSOR REFRIG PIPE MODEL NO. MOCP (AMPS) CAPACITY ELEC. (V /PH) SEER ENTERING WB' /DB- LEAVING WB' /DB- SUC. LIQ. KW STAGE RLA L.R.A. TOTAL SENS AHU -1 5.0 2000 290 0.5 1.0 6.9 10 2 A%PTM 28.8 152.8 7/8 3/8 DS=6 -06018 60.0 57.0 426 240/1 15.5 80.0/87.0 58.0/55.8 Z ALL EXHAUST FANS TO BE EQUIPT WITH BACKDRAFT DAMPERS. 1 ALL EXHAUST OUTLETS THRU ROOF AND WALLS TO HAVE A RAINCAP AND INSECT SCREEN 4. PROVIDE FAN SELECTION FOR A MAXIMUM NOISE GENERATION OF 1.2 SONES. AIR HANDER UNIT NOTES: 1. PROVIDE CUSTOMER WITH FPL REBATES FOR SEER LISTED IN SCHEDULE 2. SYSTEMS SHALL BE OF REFRIGERANT TYPE R -410A 1. AR HANDLERS SHALL BE OF AIR -TIGHT CONSTRUCTION. 4. CONDENSING UNITS TO BE PROVIDED FOR OPERATION WITH HEAT RECOVERY UNIT FOR HOT WATER HEATER 5 AHU do CU SHALL BE RATED FOR OPERATION AS A SYSTEM ST THE MANUFACTURER. EXHAUST FAN SCHEDULE - CEILING DIFFUSER ROUND NECK 177& (CEILING DIFFUSERS ARE 4 -WAY THROW UNO) LABEL TYPE OF UNIT -AREA SERVED MANUFACTURER & CFM SP MOUNTING ARRANGEMENT MOTOR H.P. RPM ELEC NOTES - CEILING DIFFUSER, ONE -WAY THROW, ARROW INDICATES DIRECTION OF AIR THROW, MODEL NUMBER - CEILING DIFFUSER TWO -WAY CORNER -- THROW, ARROWS INDICATE DIRECTION OF AIR THROW. - CEILING DIFFUSER, TWO -WAY THROW, ARROWS INDICATE DIRECTION OF AIR THROW. !WATTS} - CEILING DIFFUSER THREE -WAY THROW, - ARROWS INDICATE DIRECTION OF AIR THROW. f (V/PH) EF -1 NEW/ MODELED MASTER BATH GREENHECK SP -B150 75 0.40 IN C LING p. 129 (W) 1050 1t5 /f 2,3 1..4 EF -2 NEW POWDER ROOM GREENHECK SP-Btta 50 0.40 IN CEILING 80 (W) 648 115/1 1.2,3.4 EXHAUST FAN NOTES 1. FURNISH WITH MANUFACTURER PROVIDED SPEED CONTROLLER. ISOLATION HANGERS, BACKDRAFT DAMPER AND DISCONNECT SWITCH. Z ALL EXHAUST FANS TO BE EQUIPT WITH BACKDRAFT DAMPERS. 1 ALL EXHAUST OUTLETS THRU ROOF AND WALLS TO HAVE A RAINCAP AND INSECT SCREEN 4. PROVIDE FAN SELECTION FOR A MAXIMUM NOISE GENERATION OF 1.2 SONES. 1. EQUIPMENT CONNECTIONS: ELBOW DOWN t TRANSITION AS REQUIRED TO MAKE UNIT CONNECTION- PROVIDE FLFX15LE CONNECTIONS AT DUCTWORG COas[NECTICNS TO EQUIPMENNT (AHU, FANS, ETC.). _ ry - = n 2. SECURE CONDENSING UNIT ON 4" (MIN-) CONCRETE PAD THROUGH VIBRATION ISOLATION. 3. UNDERGROUND CONDENSATE DRAIN LINE TO BE 2 11 DIAMETER MINIMUM. 4. ALL EXHAUST DUCTS TO BE CONSTRUCTED OF SHEET METAL, TERMINATED OUTSIDE THE BUILDING, AND BE EQUIPPED WITH A BACKDRAFT DAMPER - ( NO T -FIN ALLOWED ). 5. ALL TOILETS / BATHROOMS, NOT HAVING AN OUTSIDE OPERABLE WINDOW, MUST BE PROVIDED WITH A MECHANICAL EXHAUST SYSTEM TO PRODUCE 1 COMPLETE AIR CHANGE EVERY 3 MINUTES, EXCEPT THAT WHERE THE VENTILATING AIR HAS BEEN CONDITIONED, THERE SHALL BE A COMPLETE AIR CHANGE EVERY 11/2 MINUTES. - CAN A/C DROP IN A INTERIOR TOILET / BATHROOM IS NOT SUFFICIENT OR AN ACCEPTABLE MEANS OF VENTILATION. - AN EXHAUST FAN MUST BE PROVIDED - 6. DUCTS FROM TOILETS / BATHROOMS TO BE DISCHARGED TO THE OUTSIDE OF THE BUILDING, TERMINATED NOT LESS THAN 6 INCHES ABOVE THE FINISH ROOF SURFACE, AND TO BE SCREENED WITH A CORROSION RESISTANT MATERIAL HAVING A MESH SIZE NOT LARGER THAN Lz INCH. - (PROVIDE GOOSE NECK OR RAIN CAP ON ROOF TERMINATIONS) 1- PROVIDE MINIMUM 4" DIAMETER DRYER VENTS FOR CONNECTION TO CLOTHES DRYER. CORDINATE EXACT SIZE OF VENT AND LOCATION OF VENT WITH EQUIPMENT TO BE PURCHASED. 8- CLOTHES DRYER EXHAUST DUCT TO BE A MINIMUM OF 4 INCH DIAMETER AND SHALL NOT BE SCREENED. CLOTHES DRYER EXHAUST DUCTS ( OR VENT ) TO COMPLY WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS, BE CONSTRUCTED OF A MINIMUM 26 GAUGE METAL PIPE, HAVING A SMOOTH INTERIOR SURFACE WITH JOINTS RUNNING IN THE DIRECTION OF THE AIR FLOW. DUCT JOINTS MUST NOT BE ASSEMBLED WITH SHEET METAL SCREWS OR OTHER FASTENERS WHICH WOULD EXTEND INTO THE DUCT. 10. TYPICALLY PROVIDE A UNRESTRICTED 1 INCH UNDERCUT FOR ALL ENCLOSED ROOF 1 DOORS TO ASSIST IN ACHEIVING A PROPER RETURN AIR BALANCE. IGEY NOTES. 1. NEW / RELOCATED AIR HANDLER UNIT (AHU). RELOCATE AND /OR MODIFY EXISTING REFRIGERANT / CONDENSATE PIPING AND DUCTWORK AS REQUIRED TO ACCOMMODATE NEW LAYOUT / REMODELED PLANS. 2. NEW / RELOCATED AIR CONDITIONING CONDENSING UNIT (ACLU). RELOCATE AND /OR MODIFY EXISTING REFRIGERANT /CONDENSATE PIPING AS REQUIRED TO ACCOMMODATE NEW LAYOUT / REMODELED PLANS. 3. NEW / RELOCATED EXHAUST FAN UNIT (Er-d. INTERLOCKED TO OPERATE WITH THE LIGHT SWITCH FOR THE TOILET ROOM / BATHROOM. • U. • • • ai • a • • s 1 0 � • • a r»Ir1 s NUMBER DATE ITEM SHEET TITLE: HY.A.C. FLOOR PLAN SCHEDULES AND NOTES SCALE: SHEET NUMBER: DATE: 09 -13 -2013 � 1 2411X12" - DUCTWORK, FIRST DIMENSION -IS SIDE SHOWN - CEILING DIFFUSER ROUND NECK 177& (CEILING DIFFUSERS ARE 4 -WAY THROW UNO) - FLEXIBLE DUCTWORK I I -SIDE WALL SUPPLY AIR GRILLE Note: All Existing Ductwork - CEILING RETURN AIR GRILLE, - EXHAUST FAN Vwm Dashed For Reference ROUND NECK And Clarity. L� I p"L4 OR 0411ft .f.*4 lg:G W L=wc*m111Q1 = 1. ALL CEILING DIFFUSER AIR THROW PATTERNS ARE FOUR -WAY UNLESS OTHERWISE INDICATED ON PLAN DRAWINGS IN ACCORDANCE WITH THE SYMBOLS SHOWN BELOW - CEILING DIFFUSER, ONE -WAY THROW, ARROW INDICATES DIRECTION OF AIR THROW, - CEILING DIFFUSER TWO -WAY CORNER -- THROW, ARROWS INDICATE DIRECTION OF AIR THROW. - CEILING DIFFUSER, TWO -WAY THROW, ARROWS INDICATE DIRECTION OF AIR THROW. - CEILING DIFFUSER THREE -WAY THROW, - ARROWS INDICATE DIRECTION OF AIR THROW. f • U. • • • ai • a • • s 1 0 � • • a r»Ir1 s NUMBER DATE ITEM SHEET TITLE: HY.A.C. FLOOR PLAN SCHEDULES AND NOTES SCALE: SHEET NUMBER: DATE: 09 -13 -2013 � 1 r it iM • U. • • • ai • a • • s 1 0 � • • a r»Ir1 s NUMBER DATE ITEM SHEET TITLE: HY.A.C. FLOOR PLAN SCHEDULES AND NOTES SCALE: SHEET NUMBER: DATE: 09 -13 -2013 � 1