EXISTING
METER
EXISTwa
GRADE-
EXISTNG FP.4L. OVERHEAD
SERVICE (VERIFY N FIELD).
EXISTNG 3 -04/0 T'HW CU. N
240 C. TO F.P.C. SERVICE
120/24OV. 1- PHASE, 3 -WIRE
(VERIFY N FIELD),
EXISTING
200 AMPS
200 AMPS
MAIN
I -' 2 CU. &o. To G.B. DISC
C19P.To0bxaFT.
LONE C*V.1aUD.
501,10 To 20 PT. —
SF -CTION CF
FCUPDATICN STEEL.
CET. DISC
mm
UNIT) C L DISC
EXISTING
PANEL "E"
EXISTING
200 AMPS
42 -POLES
ELECT. PANEL
I` 3 -3/0 11-0 CU 4 1 x 6
l CU. GND. N 2" C.
GMNBRAlm ELECTRICAL NOTMS:
1. ALL EXTERIOR RECEPTACLES TO BE WEATHERPROOF AND GF.I PROTECTED.
2. ALL BATHROOM, GARAGE, AND ANY RECEPTACLE WITHIN SIX (6') FEET OF
ANY SINK TO BE GF.I. PROTECTED.
3. ALL EXTERIOR DISCONNECT SWITCHES TO BE WEATHERPROOF.
4. ALL LIGHT FIXTURES, SWITCHES AND RECEPTACLES COLORS TO BE
SELECTED BY OWNER / BUILDER, SUPPLY AND INSTALLED BY ELECTRICAL
CONTRACTOR.
5. ELECTRICAL CONTRACTOR TO COORDINATE METER, METER CENTERS, AND
SWITCHGEAR LOCATIONS WITH LOCAL UTILITY COMPANY (FP4L).
6. ALL ELECTRICAL WORK TO BE INSTALLED IN ACCORDANCE WITH THE LATEST
EDITION OF THE NATIONAL ELECTRIC CODE (NEC) AND ALL OTHER
APPLICABLE LOCAL CODES.
I. ROMEX MAY BE SUBSTITUTED FOR WIRE AND CONDUIT SYSTEM FOR BUILDING
INTERIOR ONLY.
8. ALL WHIRLPOOL EQUIPMENT (IF ANY) 15 TO BE INSTALLED IN ACCORDANCE
WITH N.E.C. ARTICLE 680.
S. PROVIDE TIE HANDLE FOR DISPOSAL AND DISHWASHER CIRCUIT BREAKER
(ONLY IF ONE RECEPTACLE SUPPLIES BOTH).
10. ANY 15 AMP CIRCUIT LONGER THAN 50 FEET,INCREASE WIRE SIZE TO N 12 AWG.
11. ANY 20 AMP CIRCUIT LONGER THAN 15 FEET,INCR.EASE WIRE TO M 10 AWG.
12. ALL SWITCHGEAR AND PANELS TO RATED FOR 15 DEGREES FAHRENHEIT.
13. ELECTRICAL CONTRACTOR TO VERIFY ALL H.V.A.C. EQUIPMENT LOAD PRIOR
TO PURCHASING AND / OR INSTALLATION OF ANY SWITCHGEAR AND PANELS,
AND COORDINATE WITH GENERAL CONTRACTOR
14, ALL SMOKE DETECTORS SHALL BE COMBINATION SMOKE /CARBONMONOXIDE
DETECTORS
15. SMOKE DETECTOR MUST BE POWERED BY ELECTRIC SERVICE WITH BATTERY
BACK -UP. MULTIPLE DETECTORS MUST BE INTERCONNECTED.
I6. ALL SMOKE DETECTORS TO BE HARDWIRED TO THE NEAREST BATHROOM OR
KITCHEN LIGHTING CIRCUIT (NO G.F.I. CIRCUIT) WITH BATTERY BACK -UP,
INTERCONNECTED, AND INTEGRAL WITH ALARM SYSTEM.
11. ALL DISCONNECT SWITCHES AND PANELS TO BE INSTALLED IN ACCORDANCE
WITH NEC 100 -16.
18. TYPICAL INSTALLATION HEIGHTS ABOVE FINISH FLOOR (AFF) UNLESS
OTHERWISE NOTED:
WALL HUNG TELEPHONE: 56" A.F.F.
TELEPHONE JACKS: 12" A.F.F.
LIGHT SWITCHES: 48" APP.
RECEPTACLES: 12" AFF.
TELEVISION JACKS: 12" AFF.
IS. RECEPTACLES AND / OR JUNCTION BOXES SHALL NOT BE PLACED IN A
"BACK -TO- BACK" CONFIGURATION.
20. BEDROOMS THAT SUPPLY 120 VOLT, SINGLE -PHASE 15 AND 20 AMPERE
OUTLETS SHALL BE PROTECTED BY AN ARC -FAULT CIRG.IIT- INTERRUPTER
21. ALL 120 -VOLT, SINGLE -PHASE 15 AND 20 AMP BRANCH CIRCUITS SUPPLYING
OUTLETS INSTALLED IN THE DWELLING UNIT'S FAMILY ROOM, DINING ROOM,
LIVING ROOM, PARLOR, LIBRARY, DEN, BEDROOMS, SUNROOM, RECREATION
ROOM, CLOSETS, HALLWAYS, AND SIMILAR ROOMS AND /OR AREAS SHALL BE
PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER,
COMBINATION -TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH
CIRCUIT.
ELECTRICAL RISER DIAGRAM
TYPE: SQ "D" MAN 5US: 200 AMPS.
SERVICE: I PHASE, 3 WIRES EXISTING PANEL. firm 11 NEUTRAL: FULL
VOLTAGE: 120/240
MOUNTING: FLUSH (10)000 A.I.C. RATING) MANS: MLD
POLES: 42 LOCATION: UTILITY ROOM
K.A
NO Imp
K A
POLE
WIRE
REMARKS
ED dY IRTRr
___ ... 2.
C�NGoI
REMARKS
WIRE
PO RI=
Tom
K A
08
RELOCATED CIRCUITRY. (EXISTW4 SHOWN (SHADED)
20
V2"
012
REFRIGERATOR
1
2
SMALL APPLIANCE
• 12
1'2 "
20
ELECTRICAL CONTRACTOR SHALL SUBMIT FINAL PANEL
15
I5
20
I2"
• 111
SMALL APPLIANCE
3
4
SMALL APPLIANCE
• 12
112"
20
L5
L5
(New).
20
it"
012
LAUNDRY WASHER
5
MODIFICATIONS UNDER THIS SCOPE OF WORK/PERMIT ARE
6
DISHWASHER
• 12
112"
1 20
L2
L2
15
V"
' 14
GM LKsHTYs 4 RECEPTAGLEs
1
S
GM LKWH a 4 RECEPTACLE
014
1/2"
1 15
12
L2
15
V2"
014
GEN. L*WH 3 4 RECE=PTACLES
S
L0
GEN. LIGHTYs. 4 RECEPTACLES
014
1'2 ■
Is
L2
L2
15
V"
014
GML LI WH S 4 RECEPTACLES
11
12
GEK LIGHTYs. t RECEPTACLE
014
1/2 ■
13
12
L2
15
Vt
• 14
GM L*WlG 4 RECEPTACLES
13
14
GEN.. LICHT(G. 4 RECEPTACLE
014
1/2■
15
12
1014
2 -60
04"
06
A/G - N. (10 KW-)
(AHU W/14EATH STRIP)
i5
�+
WATER HEATER
(60 GALLON)
010
54"
2 -30
45
1.1
t8
8m
2 -50
SG{"
• 6
RANGE / C. TOP
I C,
1291
CLOTHNG DRYER
• 10
s4"
2 -30
5.0
22 4
18
20
1,12"
012
P.MJ5 JACUZZI
PUMP 115 HP,
23
24
EXTERIOR LIGHTING
012
1'2 '
20
08
25
26
EXTERIOR LIGHTING
0 12
45'
20
08
L5
20
4i"
12
CAI. RECEPTACLES
21
28
GAL RECEPTACLES
012
1'2"
20
15
L5
20
11r"
0 T1
CEILNG PADDLE PANS
2S
30
CEILING PADDLE FANS
012
1's'
20
L5
15
20
142"
• T2
SPARE
31
32
SPARE
• 12
1'2"
20
L5
SPACE
33
34
SPADE
35
36
31
38
39
40
SPACE
41
42
SPACE
22-s 11001 24b
FIRST 10,000 WATTS • 100% loom W
REMAINDER * 4o% 16,000 W T
A/C w 100% 101400 W I = �� W = 14583 AMPS. 240 V 35AAW W
mxI3tING Rms10mNcm P oposoo Nmw ADDITION �" a
EX15TING FLOOD LIGHT5 lU /.
MOTION DETECTOR SEN50R
tl tt It 11 r .ecmllo.' If l6 f !.. wp: nF1
t-1 s. 11 II i f= 11 1' 1- C -26(N)
!Il
U
Q
Ul
W
5
X
11t
Z
t-
a
a
d
3
it!
Z
a
0
Q
Q..
U!
U
a
d)
1�
a
d)
X
01
MOTION DETECTOR . _a.E. NSOR ° -
t lT� PPCG �L1. L
GENERA NOTIN.
EXISTING ELECTRICAL SERVICE IS ADEOUATE TO
LEGEND:
G- fE
EXIST
EXISTING CIRCUITRY �L
bELNG
HANPL.E NEW LOADS (See This 81" A -8 .V)
ED dY IRTRr
___ ... 2.
ELEGTWCAL LIGHTNG AND /OR RECEPTACLES SHOWN
(To Remain).
ARE CONCEPTUAL. AND REFLECT ONLY NEW AND /OR
G_s (P.)
EXISTING CIRCUITRY AFFECTED
RELOCATED CIRCUITRY. (EXISTW4 SHOWN (SHADED)
PY REMODELING (To Ronowd
FOR CONTEXT AND /OR REFERENCE ONLY).
And RNo"tod).
3.
ELECTRICAL CONTRACTOR SHALL SUBMIT FINAL PANEL
G -� (N)
NEW CIRCUITRY t0 BE ADDED
SCFEDULE TO BULL.DING DEPARTMENT.
/ INSTALLED TINDER NEW
4.
ALL NEW ELECTRICAL RECEPTACLES SHALL CONFORM
ADDITION AND /OR
TO THE F15C 2010 EDITION.
REMODELING SCOPE OF WORK
(New).
NOTE:
ONLY NEW OR RELOCATED ELECTRICAL WORK AND /OR
NEW WIRING
MODIFICATIONS UNDER THIS SCOPE OF WORK/PERMIT ARE
NDICATED ON N16 DRAWING. ALL OTHER ELECTRICAL
- _
EXISTNG TO REMAIN UNDISTUR15ED.
EXISTING WIRING.
�' � i � � i � � �r rte►
6C.-ALEE: 1/4" 11i�1I
NUMBER DATE ITEM
ELECTRICAL
FLOOR PLAN
SCHEDULES
RISER AND NOTES
SCALE: SHEET NUMBER:
1/4" = 1'-0"
DATE:
09 -13 -2013
JOB NUMBER: A 510
2013 -0531
OF SHEETS
ALL IDEAS, DESIGNS, ARRANGEMENTS, AND PLANS
INDICATED OR REPRESENTED BY THIS DRAWING ARE
OWNER AND THE PROPERTY OF THIS OFFICE. AND WERE
CREATED, EVOLVED, AND DEVELOPED FOR USE ON, AND IN
CONNECTION WITH THE SPECIFIED PROJECT. NONE OF SUCH
IDEAS, DESIGNS, ARRANGMENTS, AND PLANS SHALL BE
USED BY, OR DISCLOSED TO ANY PERSON, FIRM OR
CORPORATION FOR ANY PURPOSE WITHOUT WRTT'fEN
n'- n +.- +z,e >;.x gee ^xr e,. -.,, t. e, •r...' .. ,� +. -.n-. r...,a .. ^w