14-279-005x 0 w Im 311 P D W1 T1= LE I INS I i I R FC FE T(__D 5EFTIC T N< NEW 311 IroFI I CONNECT TO EXI &TINCA 4" 5ANITAR"r FIFE 5AN I TARY 150M ETR I G 5C,ALE: N,T 5 1. CONTRACTOR SHALL VISIT THE SITE AND THOROUGHLY FAMILIARIZE HIMSELF WITH AND VERIFY ALL EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES TO THE ARCHITECT/ ENGINEER PRIOR COMMENCING WORK. 2. THE CONTRACTOR SHALL COORDINATE THE WORK OF THIS TRADE WITH ALL OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION AND REPORT ANY DISCREPANCIES TO THE ARCHITECT/ ENGINEER. 3. REQUIRED INSURANCE SHALL BE PROVIDED BY THIS CONTRACTOR FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF WORK. 4. ALL PERMITS, FEES, INSPECTIONS AND TESTS SHALL BE THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR. 5. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS WITH THE ARCHITECTURAL PLANS. 6. ALL MATERIALS SHALL BE NEW AND OF AN AMERICAN MANUFACTURER, FREE FROM DEFECTS, INDELIBLY MARKED WITH NAME OF MANUFACTURER, WEIGHT AND/ OR CLASS. 7. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETE SYSTEM SHALL BE FULLY OPERATIVE. 8. VERIFY LOCATION, SIZE AND ELEVATION OF ALL UTILITIES PRIOR TO BEGINNING CONSTRUCTION. ADVISE ARCHITECT/ ENGINEER OF ANY DISCREPANCIES. 9. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE DRAWINGS FOR THE EXACT LOCATION OF FIXTURES AND PIPING. 10. FIRESTOPS SHALL BE PROVIDED AT ALL PLUMBING FIXTURES. 11. PROVIDE DIELECTRIC UNIONS WHERE DISSIMILAR METALS ARE JOINED. 12. ESCUTCHEONS SHALL BE CHROME PLATED BRASS WITH LOCKING SCREWS WHERE PIPES PASS THROUGH FINISHED WALLS. 13. ALL 3" OR BIGGER HORIZONTAL BRANCHES, SEWER AND DRAIN LINES SHALL BE SLOPED A MINIMUM OF 1/8 IN /FT. AND 2" OR SMALLER SHALL BE SLOPPED AT 1/4 IN /FT. UNLESS OTHERWISE INDICATED ON PLANS. 14. EVERY FIXTURE CONNECTED TO THE DRAINAGE SYSTEM SHALL BE EQUIPPED WITH A WATER SEAL TRAP. 15. ALL EXPOSED PIPING WITHIN TOILET ROOMS SHALL BE CHROME PLATED. 16. PLUMBING FIXTURES SHALL COMPLY WITH WATER CONSUMPTION TABLE 604.4 17. CONTRACTOR SHALL CONNECT WATER AND WASTE TO EQUIPMENT FURNISHED BY OTHERS AS REQUIRED FOR COMPLETE OPERATION. PLUMBING SYMBOL LEGEND SYMBOL DESCRIPTION EXISTING SANITARY LINE EXISTING WATER LINE EXISTING HOT WATER LINE - - - -- SANITARY LINE WATER LINE HOT WATER LINE CO CLEANOUT - - - --� WATER CLOSET DRAIN ----�� DISHWASHER DRAIN _ - -- VTR VENT THRU ROOF - -- -- FU FIXTURE UNIT �CWv -- COLD WATER `� - -HW ' HOT WATER GATE VALVE SHOCK ABSORBER (� NEW CONNECTION TRAP PRIMER CONNECTION JONAS HAZES CO. 27033 1/2' SLOPED TO THE FLOOR DRAIN ELECTRIC INSTANT WATER 18. CONTRACTOR SHALL GUARANTEE ALL WORK FREE FROM DEFECTS OF WORKMANSHIP AND/ OR MATERIALS FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE. 19. ALL HOT WATER PIPES SHALL BE INSULATED. WITH 1" THICK GLASS FIBER MOLDED INSULATION. WITH PRE -SIZED FACTORY APPLIED FRJ JACKET OF GLASS CLOTH WITH LONGITUDINAL LAP AND BUTT JOINT STRIPS WITH SELF SEALING ADHESIVE. 20. ALL A/C CONDENSATE DRAIN LINES SHALL BE INSULATED WITH 1/2" ARMAFLEX PIPE INSULATION.SEAL ALL SEAMS WITH INSULATION MANUFACTURER'S SOLVENT. NO TAPES ARE ALLOWED. 21. INSULATE ALL HANDICAPPED LAVATORIES, EXPOSED DRAINS AND WATER PIPING TO PROTECT AGAINST BURNING AND OR CUSHION IMPACT. USE HANDI LAV- GUARD" INSULATION KIT OR APPROVED EQUAL. COORDINATE COLOR WITH ARCHITECT. 22. ALL PLUMBING WORK SHALL BE DONE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE PLUMBING 2004. 23. PIPING MATERIALS SANITARY, GREASE WASTE, STORM, CONDENSATE DRAINAGE AND GAS: CAST IRON DRAINAGE PIPE AND FITTINGS: 1. HUB AND SPIGOT: SERVICE WEIGHT CENTRIFUGALLY SPUN CAST IRON, HUB AND SPIGOT, TAR COATED INSIDE AND OUT, ASTM A74. (BELOW GROUND) 2. NO -HUB: SERVICE WEIGHT CENTRIFUGALLY SPUN CAST IRON, NO HUB, TAR COATED INSIDE AND OUT, CISPI 301. (ABOVE GROUND) CAST IRON PIPE JOINT: A. NO HUB: 1. NEOPRENE GASKET: ASTM C564. 2. STAINLESS STEEL CLAMP AND SHIELD ASSEMBLY: 300 SERIES, CISPI 301 -69T. SWEAT PROOFING: SWEAT PROOF HORIZONTAL STORM DRAINAGE PIPING BETWEEN DRAIN AND VERTICAL LEADER RUNNING IN CONDITIONED AIR SPACE OR PLENUMS WITH 1/2" THICK GLASS FIBER SECTIONAL PIPE COVERING WITH FLAME RETARDANT VAPOR BARRIER JACKET. COPPER TUBING: '2" AND SMALLER) TYPE "K" OR" L ": SEAMLESS HARD DRAWN OR ANNEALED, ASTM B88. TYPE DWV: SEAMLESS HARD DRAWN, ASTM B306. DOMESTIC WATER SUPPLY PIPING: A. ABOVE GROUND: COPPER TUBING TYPE "L" WITH BRONZE OR WROUGHT COPPER SOLDER JOINT FITTINGS WITH 95/5 SOLDER. GAS PIPES: SHALL BE STEEL SCH 40, AND SHALL COMPLY WITH AT LEAST ONE STANDARD: ASME B 36.10, 1OM; ASTM A 53; or ASTM A 106. G101T, TO "P" TRAP FIXTURE CONNECTION SCHEDULE w �- m SANITARY C 0 r SYM. FIX WASTE CW HW REMARKS LAV LAVATORY 1 1/2" 1/2" 1/2' OVAL SHAPED. VITREOUS CHINA. SELF RIMMING W/ �� CL zz FITTINGS. PROVIDE BASE CABINETS & COUNTERTOP. HLAV LAVATORY 1 1/2' 1/2' 1/2" OVA- SHAPED. VITREOUS CHINA. SELF RIMMING W/ F- w a FITTINGS. HANDICAPPED. WALL HUNG. WC WATER 4' i/2' AM RICAN STANDARD - CADET�RICANSE #2467.100 CLOSET Z w jHWC WATER 4' 1" - FLOOR MOUNTED. HANDICAPPED. SAME AS ABOVE UR URINAL 2" 1° _ WALL HUNG VALVE -TYPE �- m 'd' WATER CONSEVATION TYPE, LESS THAN 1.0 GPF. FD FLOOR DRAIN 3' - - 1/2' AUTOMATIC TRAP PRIMER, PRESSURE ACTIVATED EWC ELECTRIC WATER COOLER 1 %' 1/2'� - HI /Low ELECTRICAL WATER COOLER ADA COMPLIANT JS JANITOR'S 1 1 / 2' 1/2' 1 /2' FAUCET WITH BUCKET HOOK, 30' HOSE & BRACKET. SINK t!3 MOP HANGER. STAINLESS STEEL BUMPER GUARD. PROVIDE 54" SIDE & BACK SPLASH PROTECTION HB HOSE BIBB - 3/4 "_ WITH VACUUM BREAKERS AND NON- LOCKEABLE COVERS � IL WITH SHUT -OFF VALVE NOTES 1. ALL PLUMBING FIXTURES SHALL BE KOHLER, AMERICAN STANDART OR EQUAL AND PURCHASED AND INSTALLED BY PLUMBING CONTRACTOR. 2. ALL FAUCETS AND FIXTURES SHALL LEVER HANDLE TYPE COMFORMING TO FACBC, ADA, AND FBC 2004. UNION (TYP) -N,, UNION (TYP) S.O.V. (TYP) RELIEF VALVE AIR GAP AS 1/2" COLD WATER PIPE REQUIRED BY CODE 1/2' P &T RELIEF PIPE TO OUTSIDE BUILDING TERMINATE 6" ABOVE GRADE 1/2- HOT WATER PIPE TYP. TANKLESS WATER HEATER PIPING DIAGRAM TWH f1: ELECTRIC TANKL.ESS WATER HEATER "TITAN" (OR APPROVED EQUIVALENT) MODEL NO. Mini 3 Stiebel -Eltron , 3.OKW, 120 /1 /60. FLOW RATE 0.4 GPM AT 72'F, 1 YEAR WARRANTY. ENERGY FACTOR 0.95, DIMENSIONS 7.2' (HEIGHT) x 6.5' (WIDTH) X 3.25" (DEPTH). ABSORBERS SELECTOR ABSORBOTRON TYPE NO.� 1485 -1 1485 -2 1485 -3 1485 -4 1485- 1485 -6 P.D.I. SYMBOLS *A - B C D E F FIXTURE UNIT RATING 1 - 11 12 - 32 33 - 60 61 - 1131114 - 154 ,1155 - 330 * CLASSIFICATIONS ESTABLISHED BY THE PLUMBING AND DRAINAGE INSTITUTE STANDARD P.D.I. - WH2O1" FIELD COORDINATION NOTE: CONTRACTOR SHALL COORDINATE IN FIELD WORK WITH OTHER TRADES PRIOR TO START OF CONSTRUCTION THE LOCATION OF ALL CEILING, WALL AND FLOOR FIXTURES AND DEVICES - NOTIFY ARCHITECT /ENGINEER OF ANY CONFLICTS PRIOR TO INSTALLATION, THE OWNER SHALL NOT INCUR IN ANY ADDITIONAL COSTS. �MRRA__ ry . n onSultmg, -Inc " 3i�1 CORAL WAY -648 MIAMI, FL, 33145 - PhonR! 305 -74- 4-9403 44" Fax:786- 515 -981 C.o.A -# 2087M i cc a Q w Q 4 a r m �; w �- m z C 0 r 0� 90 z 0 < 0 U E- 0 u- 0 m CL zz a 12 0 W �-. Z J 0� 90 z t} -" Zm w to U E- .E_ i 00 IL Lu n 0 F- w a a SHEET IDENTIFICATION P -1 0 MCC a z't m == ch M z J LL a .E_ I F- w m cz F4- ;--• > Z Z w u .v ® Cn �- m 'd' Co Z t!3 � J IL td SHEET IDENTIFICATION P -1 0 MCC a z't m ==