Loading...
12-260R-0040o Z =III III= ( =I IF -1 I I=I I I=I I I =1 I I =� -I REFRIGERATION PIPING — PIPE INSULATION FLP —PVC D. 40 CONTINUOUS PIPE SLEEVE I- BENDS ® 45' ELBOW REFRIGERANT PIPE DETAIL SCALE: N.T.S. AIR DUCT 4/M -1 SPACE �I STUDS ® 24" O.C. REFRIGERATION LINES FILTER /FAN ACCESS PANEL NOTE: SS MODEL # 17485 BOLT CONDENSING UNIT TO CONC. PAD TO LOAD 160 LBS. WITHSTAND 146 MPH HURRICANE FORCE WINDS. HEATER ACCESS PANEL COIL ACCESS PANEL 1/4" SS COATED CABLE SEER SECURE PER DADE TOTAL COUNTY ORD. 8 C -5 1/4" WIRE /ROPE DB CLAMPS GROOVED PROVIDE METAL SUPPORT BY 1 1/4" P.V.C. OTHER DRAIN TRAP AND UNION PROVIDE LOW VOLTAGE CONS. TRAP W/ CLEANOUT OVERFLOW SHUT -OFF SAFETY SWITCH MODEL # S52 BY SMD NEW RESERCH INC. FLOAT SWITCH REFRIGERANT LINE 1" A/C CLOSET INSTALLATION DETAIL SCALE: N.T.S. 2 -1/4" TURNBUCKLES NOTE: SS MODEL # 17485 BOLT CONDENSING UNIT TO CONC. PAD TO LOAD 160 LBS. WITHSTAND 146 MPH HURRICANE FORCE WINDS. CONDENSING UNIT 1/4" SS COATED CABLE SEER SECURE PER DADE TOTAL COUNTY ORD. 8 C -5 1/4" WIRE /ROPE DB CLAMPS GROOVED ELEC. POWER SUPPLY CLAMPS HOLDS CABLES CONNECTIONS 6" CONC. CAST LIQUID LINE W/O IN PLACE @ SAME INSULATION HEIGHT AS MAIN 850 FLOOR 24.9 67 SUCTION LINE W/ 1/2" CHAIN LINK, 1/4" ARMAFLEX INSULATION 1/4" STOCK & VAPOR BARRIOR 2 -1/4" LONG GOODMAN MODEL 12895 LIQUID & SUCTION PIPING IS ABOVE 318 GRADE, SEE PLAN. 5/16 "X4" LAG EYEBOLTS LO SS ® EACH CABLE END PROVIDE ANCHORED BOLTS TO PREVENT THEFT PER DADE COUNTY ORD. 812-5 CONDENSING UNIT DETAIL ,• SCALE: N.T.S. SEAL GAP BETWEEN SLEEVE AND DUCT W/ EXPANSION FOAM AND CAULK TO DRYWALL VENT DUCT 4" DIA. AL. 26 GA. MIN, SHEET METAL DUCT. UL /81 CLASS LOUVERED VENT COVER W/ NO SCREEN - SCREW TO 2X4 BLKG DRYER BEHIND STUCCO 4 1/2" MIN. DIA. HOLE THROUGH ICF SYSTEM - G.C. TO BLOCK OUT HOLE 4" FLEX DUCT BEFORE POURING HOSE CLAMP CONCRETE CONDENSING UNIT DETAIL �UJ SCALE: N.T.S. R -6 FLEX DUCT AIR INTAKE - DUCT SIZE PER MECH. PLAN. UTILITY ROOM CLG. + 7' -0" NINECT OA DUCT AHU RA INTAKE SCALE: N.T.S. TRANSITION TO 4 "X8" SS DUCT THRU SOFFIT FIBERGLAS DUCT 2 1/2" SQ. WASHER 1"X3" 22 GA SHT MTL, ® 12" O.C. MIN. 2 /SIDE SELF TAP SCREW #10 X 1 1/4" SHT. MTL SCREW GFM CLOSURE AIR HANDLER 1DUCT TO AHU SCALE: N.T.S. LOW VELOCITY SUPPLY MTL ROUND FITTING QUADRANT OPERATOR TO BE OUTSIDE INSULATION PROVIDE INSULATION GUARD AS REQUIRED R -6 INSULAT D-FLEXIBLE DUCT SEAL ALL JOINTS W/ MASTIC PERFORATED DIFFUSER 1-.,.FAMCO 6" GALV. DAMPER WALL VENT W/ J" INSECT T SCREEN & EXTRA LONG THROAT. VERIFY DIRECTION OF BDD SET TO INTAKE - COORDINATE INSTALLATION W/ ICF INSTALLER - PROVIDE SLEEVE THRU CONCRETE SCALE: N.T.S. PROVIDE 1" METAL STRAP GAUGE 16 FOR ALL DUCT HANGER INSIDE ATTIC. ATTACHED TO STRUCTURE W/ aR�OW BOLTED CONN. PROVIDE 1" SHEET METAL BAND CLAMP ATTACH TO STRUCTURE W /10d NAILS 1 1/2" FORMED SHEET METAL GAUGE 16 BAND CLAMP EXHAUST FAN SCHEDULE TYPE DUCT VERT. NUTONE MODEL # 606 ENERGY STAR SIZE 4" DISCHARGE 50 CFM CEILING - SLOPED ROOF CAP. _ CORROSION RESISTANT WIRE MESH TERMINATION ,ROOF 4" METAL DUCT EXH. FAN WITH /D I AIR GRILLE SCALE: N.T.S. AIR GENERAL H.V.A.C. NOTES 1. The contractor shall furnish all labor, material and equipment for a complete H.V.A.C. system in accordance with these drawinggs. The Florida Building Code 200712009 and the latest edition of fhe following publications: (a)ANS B9.1 Mechanical Refrigeration (b) NFPA Pamphlets 90A & 91 (c) SMACNA (d) ASHRAE. 2. All air conditioning ductwork shall be 1 112 " standard duty foil reinforced fiberglass (R -6) manufactured logo printed on the vapor barrier. 3. All exhaust ductwork shall be code gage galvanized sheet metal. 4. Duct sizes shown are net free area inside. 5. All air devices (diffusers, registers and grilles) shall be all aluminum construction, with exposed surface chemically treated to receive paint to match color or AIRGUIDE or approved equal. with minimum 7590 free area. 6. Provide opposed blade dampers at all diffusers and registers. 7. Thermostats shall be combination cooling /heating with system Cool /Auto /Heat /Off and Fan On /Auto selector switches. 8. Refrigerant pipingg shall be copper type "L" with 314" armoflex. Insulation shall be provided for suction lines. 9. Provide new filters for fan coil before starting. These filters must also be replaced prior to final acceptance by owner. J W.I.C. EF -1 l -.1 MA5fF, CEILING fl DIFFUSERS S 57CFM 4 "DI 4 "DIA 8 8 "x10" CEILING S S DIFFUSER SCALE: 1 /4 "= -1' -0" L 0 CONDENSING UNIT 1 DESIGNATION CFM MBTUH ENTERING F ELECTRICAL DATA MANUFAC. REF. UNIT SEER OBS TOTAL SENSIBLE WB DB VOLTS PHASES HTNG KW WIRE AMPS FUSES LIQ. SUC. COND. CU -1 850 34.6 24.9 67 80 230 1 11 25 30 GOODMAN DSXC 160361 A 16 318 718 1 AIR HANDLING UNIT 1 DESIGNATION MBTUH TEMP. ENT. CONDENSER ELECTRICAL DATA MANUFAC. REF. UNIT OBS OR SEER AREA SERVED VOLTS PHASES WIRE AMPS FUSES AHU -1 36.0 90 230 1 18.6 25 GOODMAN CA *F3642 *6D *TVX 16 1570 DRYER VENT NOTES: 1, CLOTHES DRYER EXHAUST TO BE 30 GA. MIN. 2. CLOTHES DRYER EXHAUST -NO PROTRUSIONS INSIDE DUCT 3. CLOTHES DRYER EXHAUST SHALL BE MIN. 4' DIA. 4. CLOTHES DRYER EXHAUST SHALL NOT BE SCREENED. 5, CLOTHES DRYER EXHAUST SHALL HAVE BACKDRAFT DAMPER SPACE PROVIDED. SUFFICIENT SPACE SHALL BE PROVIDED ADJACENT TO ALL MECHANICAL COMPONENTS LOCATED IN OR FORMING A ' PART OF THE AIR DISTRIBUTION SYSTEM TO ASSURE ADEQUATE ACCESS FOR 1. CONSTRUCTION AND SEALING IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 603.1 OF THIS CODE 2. INSPECTION 3. CLEANING AND MAINTENANCE: A MIN. OF 4" IS CONSIDERED SUFFICIENT SPACE AROUND AIR HANDLING UNIT PER FBC MECHANICAL 603.1.3 HVAC DESIGN CHART HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR (S) RAG -( RETURN AIR GRILL)) QT FIRE DAMPER (S) AIR FLOW DIREC77ON ( ARROWS DENOTE SMOKE DAMPER (S) 1 WAY, 2 WAY, ETC., SEE PLANS RETURN OR EXHAUST, SEE PLANS. FIRE RATED ENCLOSURE n FIRE RATED ROOF /FLOOR w FIRE RATED CEILING ASSEMBLY SIDE REGISTER ✓ FIRE STOPPING CG CEILING GRILLE SMOKE CONTROL FULL LOUVERED DOOR CU O w I— pa Z 0 IHAUST DTL. THIS :ET F NOTE: THIS IS A SEALED ATTIC. LOCATE (1) 150 CFM 6"X10" SUPPLY REGISTER IN ATTIC. SPRAY FOAM INSULATION TO BE INSTALLED ON UNDERSIDE OF ROOF SHEATHING. SEE SECTION A -2 LEGEND NAT CEILING GRILLE SEE SIZE SCHEDULE '4" DUCT TO MATCH NECK SIZE TYP. 0 RAG -( RETURN AIR GRILL)) QT THERMOSTAT AIR FLOW DIREC77ON ( ARROWS DENOTE —� 1 WAY, 2 WAY, ETC., SEE PLANS RETURN OR EXHAUST, SEE PLANS. ^ n n n WALL MOUNTED SIDE REGISTER. w S.R. SIDE REGISTER CD CEILING DIFFUSER CG CEILING GRILLE F.L.D FULL LOUVERED DOOR CU CONDENSING UNIT AHU AIR HANDLER UNIT UC UNDERCUT DOOR FOR AIR RETURN u� rX 1 .w (M a LO a Q r"\ -_ co Uj T_ ^ n n n w Z °o a W > V- ^� hnnnn (3 C-) FM 4 nn__ Qnnnnn - -nnnn C Z LO �' Y. ,• Z t9 W Z W M 0 Z o a W W U. = / a�a11ft m O D o O I' 0 � 1 G Q to O Z.. .. W U3 O u� rX 1 .w (M a LO a Q r"\ -_ co Uj T_ Z I-- O Z °o W > V- WU I-- W (3 C-) FM 4 Q Cn C u� rX 1 .w (M LO r"\ -_ T_ Y O a 00 LO �' N 1 ,• W I I i,v U CD � F "�Dy 4V',•''ti� A"�;; ^ ,•' • � ' M V J. • to - ?� AN" O aamu AM UWUIIL m NONE ar M AIlCN1Q:L M alit MAY NOT N DUIMJOA Um at UM= so= a�M�orr W M oo JOB No.: 12.06477.SFR N REVISIONS: 10 6 -17 -13 CU DATE: 3/5/2012 CHECKED BY: DRAWN BY: SRL PLOT: 100% SHEET INDEX: MECHANICAL PLAN NOTES SHEET No.: M -1 I