ELECTRICAL MOTES
1) CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND
EQUIPMENT FOR COMPLETE ELECTRICAL INSTALLATION IN ACCORDANCE
WITH THESE DRAWINGS.
2) COMPLY WITH THE N.E.C. AND STANDARD BUILDING CODE.
3) PROVIDE EMPTY CONDUITS AS REQUIRED FOR TELEPHONE SYSTEM.
4) OBTAIN ALL PERMITS FOR WORK UNDER THIS CONTRACT.
5) PROVIDE TEMPORARY POWER AND LIGHT OUTLETS FOR USE BY
OTHER TRADES.
6) PROVIDE ALL REQUIRED CONNECTIONS FOR OTHER TRADES.
7) COORDINATE ALL OUTLET LOCATIONS WITH BUILDING ARCHITECTURAL
FEATURES.
8) CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE HIMSELF WITH
ALL EXISTING CONDITIONS. 9) ALL CABLE SHALL BE COPPER.
10) INDOOR CONDUITS SHALL BE EMT.
1 1) ALL MOUNTING HARDWARE SHALL BE BY CONTRACTOR.
12) OUTDOOR UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC.
UNDER PAVED AREAS IT SHALL BE ENCASED IN CONCRETE. MINIMUM
COVER SHALL BE 24 INCHES.
.CONTROL WIRING TO OTHER
SMOKE DETECTORS INSIDE UNIT
SD
SMOKE
120 V.
SWITCH LEG PHASE COND.
S.D. SWITCH LINE DIDE
OF SWITCH
SMOKE DETECTOR DIAGRAM
SCALE N.T.S.
NOTE
1. SMOKE DETECTORS SHALL BE HARDWIRE (110
VOLT TYPE) TO A NON SWITCH ABLE KITCHEN OR
BATHROOM LIGHTING CIRCUIT WITH BATTERY
BACK UP AND SHALL NOT BE CONNECTED ONTO
THE LOAD SIDE OF GROUND FAULT CIRCUIT
INTERRUPTER ALL SMOKE DETECTORS WITHIN
EACH UNIT SHALL BE INTERCONNECTED.
2. SMOKE DETECTORS SHALL NOT BE
PLACED WITHIN 3 FT OF ANY A/C GRILL OR BATH DR.
3. PROVIDE ARC -FAULT CIRCUIT INTERRUPTER
PROTECTION FOR ALL 15 AND 20 AMP 125 VOLT
BEDROOM BRANCH CIRCUIT OUTLETS. NEC
210 -12
NOTE.
ELEC. CONTR. HAS OPTION OF [METHOD A] RUNNING ROMEX
W/ PROTECTION PLATES IN CHANNEL TO BE CUT THROUGH
POLYSTYRENE EXT. WALLS OR [METHOD B] IN CONDUIT RUN
UNDER SLAB AND UP TO DEVICES W/ BOXES MOUNTED PRIOR
TO POURING CONCRETE IN ICF WALLS. METHOD A: ROMEX
WOULD BE SECURED TO PLASTIC ICF TIES LOCATED AT 6" ON
CENTER 0 518" BEHIND SURFACE OF POLYSTYRENE. DRYWALL
WILL BE INSTALLED DIRECTLY ON ICF BLOCKS. ALL ELEC.
BOXES MUST BE ATTACHED TO CONCRETE LOCATED 1 718"
BEHIND SURFACE OF POLYSTYRENE. BOXES MUST NOT BE
DEEPER THAN 2 3/8 ". METHOD B: ALL DEVICE BOXES CUT
INTO ICF BLOCKS PRIOR TO CONCRETE POUR MUST BE
SECURELY BRACED TO RESIST PRESSURE OF WET CONCRETE.
ELECTRICAL LOAD
CALCULATI ❑N NEW PANEL "A"
SQ. FT, -------------- - - - - --
1,570
GENERAL LIGHTING (3W, /S,F.) -
-- 4,710
SMALL APPLIANCES------ - - - -
-- 3,000
REFRIGERATOR ---------------
1,000
DISHWASHER----------- - - - -
-- 500
DISPOSAL --------------------
800
WASHER--------------- - - - -
-- 750
DRYER---------------- - - - -
-- 6,800
MICROWAVE ------------------
1,500
RANGE--------------- - - - - --
12,000
WATER HEATER--------- - - - -
-- 16,000
SPRINKLER PUMP------- - - - - --
1,200
50
48,260
CONNECTED L❑ADi (LESS A /C) -- 48,260
FIRST 1OKW @ 100%----- - - - - -- 10,000
BAL. @ 40%----------- - - - - -- 15,304
A/C OR HTG, @ 100 %---- - - - - -- 8,040
DEMAND LOAD------- - - - - -- 33,344
AMPS @ 240/12OV, 1PH,- - - - - -- -139 AMP
PANEL / MCB -------- - - - - -- -200 AMP.
NOTES
ALL SMOKE DETECTORS SHOULD BE NOT LESS
3' -0" FROM A/C GRILLS & RELOCATED IF
NECESARY.
WET LOCATION NOTES:
1. ALL ELECT. EQUIP. EXPOSED TO WEATHER
SHALL COMPLY TO NEC 373 -2 (A)
2. SWITCHES OR CIRCUIT BREAKERS
IN WET LOCATION OR OUTSIDE OF
A BUILDING SHALL BE ENCLOSED
IN A WEATHERPROOF ENCLOSURE
OR CABINET. PER NEC 380 -4
3. NO SWITCHES SHALL BE INSTALLED
WITHIN WET LOCATION
GENERAL MOTES
Lo` aVm see plan NEW PANEL "A" Main BU& 200 AMP 32 SPACE 40 CRCCUIi' GE
V~ 1201240 v, 1f ,3W Main Breaker METER COMBO (MCS)
Mounting RECD AIC& 10,000
GFI= Ground Fault Interrupter NCL= Non — concurrent load REC= Receptacle Ckt Lts= Lighting Ckt ST= Breaker with shunt trip T =Via timer
IS= Isolated ground Ckt C= Via contactor SWD= On —Off Switching Duty rated breaker,as per NEC 240 -83(d) LV= Via low voltage transformer
HACK= Breaker suitable for the protection of heating, A/C and refrigeration equipment
Ckt
No.
USE
SPEC
VOLT
BKR
AMP
WIRE
COND
SIZE
VA
PHASE
Ckt
No.
USE
SPEC
VOLT
BKR
AMP
WIRE
COND
SIZE
VA
A C
RANGE
LLI
240
50
6
314
12,000
2
C. U.
240
30
10
314
5,000
3
4
o!
5
DRYER
o
240
30
10
112
6,800
p
6
REFRIGERATOR
W
120
20
12
112
800
7
8
BATH 11 WIC LIGHTS & REC
120
15
14
112
• • *)
Cl)
9
WH 1
Z
240
70
4
314
11, 800
10
MBR LIGHT & REC.
LL
=
120
15
14
112
• •_
11
12
BR 2, HALL, UTIL, LT. &REC.
O
120
15
14
112
06
13
WASHER
U
120
20
12
112
750
r
o
14
BR 3, BATH 2 LT. & REC.
U.
120
15
14
112
• •+
15
BATH 1 GFI
120
20
12
112
G
16
BATH 2 GFI
120
20
12
112
•
17
GARBAGE DISPOSAL
120
20
12
112
Boo
18
KITCHEN, FOYER LT. & REC
120
15
14
112
•(• ■)
19
DISHWASHER
C)
120
20
12
112
500
20
DINING, GR. LIGHT & REC
120
20
12
112
�(_)
21
SMALL APPLIANCE
120
20
12
1/2
1500
22
SPARE
23
SMALL APPLIANCE
120
20
12
112
1500
24
EXTERIOR LIGHTS & REC
120
20
12
112
25
MICROWAVE
120
20
12
1 2
1000
26
SPARE
A.H.U.
240
40
8
3/4
8,040
WH 2
220
25
10
112
4,200
29
30
31
SPARE
32
SPARE
( *) AS PER SQ —FT OF CONDITION SPACE
** ARC FAULT CIRCUIT INTERRUPTER PROTECTION
1. PROVIDE EXPANSION JOINTS FITTINGS TO CONDUITS CROSSING
STRUCTURAL EXPANSION JOINTS.
2. PROVIDE PULL WIRES IN TELEPHONE AND ALL EMPTY
CONDUIT SYSTEMS.
3. ALL CONDUCTORS SHALL BE COPPER,
4. ALL CONTROL WIRES AND CONNECTIONS REQUIRED FOR AIR
CONDITIONING AND VENTILATING EQUIPMENT OPERATION SHALL
BE PROVIDED. REFER TO MECHANICAL DRAWING.
5. LOCATION OF OUTLETS IN ELECTRICIAN DRAWINGS IS
DIAGRAMMATIC. CHECK ARCHITECTURAL DRAWINGS FOR EXACT
LOCATION OF OUTLETS. ADJUST OUTLET LOCATIONS TO AVOID
INTERFERENCE WITH OTHER TRADES.
6. LOCATION OF SWITCHES VARIES WITH THE DOOR SWING:
FOLLOW ARCHITECTURAL DRAWINGS IN EACH CASE.
7. CLAIMS FOR EXTRA WORK REQ'D TO MEETCODE REQUIREMENTS
WILL NOT BE CONSIDERED.
8. AMONG ELECTRICAL CONTRACTOR'S RESPONSIBILITIES THERE
SHALL BE:
8.1 - TO VERIFY ACTUAL FIELD CONDITIONS PRIOR BIDDING.
ONCE THE AMOUNT OF WORK INVOLVED HAS BEEN DETERMINED,
THE CONTRACTOR SHALL INCLUDE IN HIS BID ALL NECESSARY
PARTS AND LABOR REQUIRED TO COMPLETE A SAFE AND
CORRECT ELECTRICAL INSTALLATION.
8.2 - TO PROVIDE ADEQUATE WIRING, BREAKER OR SWITCH
PROTECTION TO CONFORM WITH FURNISHED EQUIPMENT WITHOUT
EXTRA COST TO THE OWNER.
8.3 - TO CONTACT F.P.L. COMPANY'S REPRESENTATIVE TO
DETERMINE FINAL UNDERGROUND PRIMARY CONDUITS ROUTING AND
TO INSTALL THEM AS PER F.P.L. COMPANY'S STANDARDS.
8.4 TO CONTACT TELEPHONE COMPANY'S REPRESENTATIVE TO
DETERMINE FINAL ROUTING UNDERGROUND CONDUITS FOR
TELEPHONE SUPPLY AND TO INSTALL THEM AS PER THE
COMPANY'S STANDARDS.
8.5 TO VERIFY EXISTING UTILITIES FACILITIES PRIOR
TRENCHING.
8.6 TO COORDINATE, PRIOR TO CONSTRUCTION, WITH
MECHANICAL AND PLUMBING SUBCONTRACTORS REGARDING SPACE
REQUIRED FOR FULL INSTALLATION. AND POSSIBLE CONFLICTS.
9. ALL 15 AND 20 AMP OUTLETS IN FAMILY ROOM, DINING ROOM, LIVING
ROOM, BEDROOMS, CLOSETS, HALLWAY TO BE PROTECTED BY A LISTED ARC
FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE.
10. ALL OUTLETS TO BE TAMPLER PROOF TYPE
p LS A24
VP
M
LS
F
7A2
�I
\ MS
A24�LS
\VF
A
— — —WP -A2-4 CW 2 _1, 9 —
4G r� 1
L__ — — — — — — — — — — ___j
SCALE: 1/4"=-V-01'
TO FPL
3 #210 THWN (Cu)
IN 2" COND.
RUNNING FROM
F.P.L. SERVICE POINT.
WEATHER HEAD
ELEC.
METER
O
200A
MCB
1 # 4 THWN (Cu)
IN 314" COND.
GRADE LEVEL
NEW 10' -0" DEEP GRC
ROD — 112" DIAMETER
PITCH POCKET /CAP
EXTERIOR r INTERIOR 314" EMT TO ROOF
`r FOR FUTURE SOLAR
TERMINATE +4FT AFF
ELECT.
PANEL "A
Al
-3 #210 THWN (Cu)
HOSE BIBB 1#6 THWN (Cu) G
I , IN 2 ' COND.
:.
34 "0
CWP :!
NEW #4 IN 1/2" CONDUIT
TO (2) 5/8" X 10 FT GROUND
RODS ® MIN. 6 FT APART
ELECTRICAL RISER DIAGRAM
N.T.S.
A24
LS VP
i
i
i
i
i
I
I
I
I
I it
ELEC. MT.
I
MS I�
rLilsaw"l
9
APPiMr101t� 0011t1tt ri M& AND
MUIfNl�J�lD tttlNt W M Ancmr a7'L Im
YAY IICT t CI✓�Ltt?11 11tt1D at
WMff tt#nE,f a�notr
JOB No.:
12.06487.SFR'
REVISIONS:
10 6 -17 -13 CU
DATE: 3/5/2012
CHECKED BY:
DRAWN BY: SRL
PLOT: 100%
SHEET INDEX:
ELECTRICAL PLAN
NOTES
SHEET No.:
E -1
a
a
Z
p
n
Q
M
LLI
0
co
o!
Z
o
00
Z
o
p
t9
W
3
N
LLJ
Z
W
W
~
�¢
M
c
0
Cl)
(M M
C�
Z
O
Oct
LU
Uj
LL
=
/
Q
M
J
Co
Z
0
O
C
T
06
0
CO)
U
O
LL
J
a
r
o
_
U.
0
in
cf)
=
oN
G
LiJ
M
10
Z
C,
D
CC
Lil
C)
CL
Q
o
LL_
APPiMr101t� 0011t1tt ri M& AND
MUIfNl�J�lD tttlNt W M Ancmr a7'L Im
YAY IICT t CI✓�Ltt?11 11tt1D at
WMff tt#nE,f a�notr
JOB No.:
12.06487.SFR'
REVISIONS:
10 6 -17 -13 CU
DATE: 3/5/2012
CHECKED BY:
DRAWN BY: SRL
PLOT: 100%
SHEET INDEX:
ELECTRICAL PLAN
NOTES
SHEET No.:
E -1
a
a
n
Q
M
LLI
0
co
o!
Z
o
00
o
p
R)
>
3
N
LLJ
CD
W
~
�¢
C
c
Q
Cl)
(M M
=3
t�
APPiMr101t� 0011t1tt ri M& AND
MUIfNl�J�lD tttlNt W M Ancmr a7'L Im
YAY IICT t CI✓�Ltt?11 11tt1D at
WMff tt#nE,f a�notr
JOB No.:
12.06487.SFR'
REVISIONS:
10 6 -17 -13 CU
DATE: 3/5/2012
CHECKED BY:
DRAWN BY: SRL
PLOT: 100%
SHEET INDEX:
ELECTRICAL PLAN
NOTES
SHEET No.:
E -1