12-754-003NOTES: INSTALL NEW 2' SOLID INSULATION IN CEILING OF NEW FAMILY ROOM COVERED WITH NEW T6G WOOD FINISH. INTERIOR WALLS OF NEW FAMILY ROOM TO HAVE NEW 1/2' DRYWALL. W -1, ❑ FLOOR PLAN NOTES ❑ MARK DESCRIPTION 1 FLAT HEADER AT V -4' A.F.F. 2� FRAME OUT EXISTING DOOR OPENING AND FINISH TO MATCH EXISTING. ® TILE FLOORING - PER SPECS. ® PROVIDE THRESHOLD AND UIEATHERSTRIPPING AS REQ'D. s- ca a� 42' HIGH GUARDRAIL. ® HANDRAIL AT 36' H. ABOVE TREAD NOSING. I REMOVE EXISTING WINDOW AND BLOCK UP OPENING AND FIN. TO MATCH EXISTING. ® EXTEND EXISTING FLOOR TO THIS AREA. ® HATCHED AREAS INDICATES EXISTING FLOOR AND STRUCTURE. ALL EXTERIOR DOORS AND UUINDOUIS SHALL BE IMPACT RESISTANT. DOOR SIZE MASONRY OPENING POSITIVE NEGATIVE MARK STYLE WIDTH HEIGHT WIDTH HEIGHT U Single - French Alum. 3' -0' 6' -8' 3' -3' 6' -9 1/2' +41 +62 I DOOR MASONRY OPENINGS WITH TO PLACEMENT OF CONCRETE. GENERAJ..., NOTES 1. ALL WORK SHALL COMPLY WITH THE 2010 EDITION OF THE FLORIDA BUILDING CODE, EXISTING, AND 2010 FLORIDA BUILDING CODE, RESIDENTIAL. 2. THE CONTRACTOR SHALL REVIEW THE DRAWINGS IN THEIR ENTIRETY BEFORE STARTING WORK AND SHALL ACCEPT FULL RESPONSIBILITY FOR ANY ERRORS OR OMISSIONS NOT REPORTED IMMEDIATELY IN WRITING TO THE ARCHITECT. BACKCHARGES WILL NOT BE ACCEPTED. DO NOT SCALE THE DRAWIN635. 3. THE CONTRACTOR SHALL COORDINATE ALL OF THE WORK OF ALL TRADES. 4. SUBMIT A MINIMUM OF THREE (3) COPIES OF SHOP DRAWINGS FOR FLOOR AND ROOF SYSTEMS FOR REVIEW AND APPROVAL BY THE ARCHITECT PRIOR TO FABRICATION. 5. THESE PLANS, AS DRAWN AND NOTED TO COMPLY WITH THE BUILDING ENVELOPE ENERGY REQUIREMENTS OF THE FLORIDA ENEMY CODE FOR BUILDING CONSTRUCTION INCORPORATED AS CHAPTER 13 OF THE FLORIDA BUILDING CODE. (o. THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE GOVERNING CODES IN THEIR ENTIRETY. ALL WORK SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, 2010 EDITION, EXISTING AND RESIDENTIAL - 1. THE CONTRACTOR IS RESPONSIBLE FOR ADEQUATE BRACING OF STRUCTURAL OR NON - STRUCTURAL MEMBERS DURING CONSTRUCTION. 8. NEW DOORS AND WINDOWS SHALL BE IMPACT RESISTANT AND UNDER SEPARATE PERMIT. S. ALL GLAZING IN HAZARDOUS AREAS SHALL BE TEMPERED UNLESS IMPACT RESISTANT. LECzEND EXISTING - NO CHANGE r ,,ITY OF SOUTH MIAMf ^ C-MIL Its DEPT- STRUCTURAL SECTION VED NOTE: NEW WORK IN TH15 AREA ONLY WINDOWS AND DOOR5 EXISTING TO BE REMOVED IMFACT RE515TANT. NEW 8' CMU WALL W/ FILLED CELLS. SEE STRUCT. PLAN EXISTING - NO CHANGE r ,,ITY OF SOUTH MIAMf ^ C-MIL Its DEPT- STRUCTURAL SECTION VED NOTE: ALL EXTERIOR WINDOWS AND DOOR5 ARE IMFACT RE515TANT. Z s- ca a� � wa d) Lu V O Q U a a V �Xm s m� Ct% o L1 r Clw r! " L a M Z s- ca a� � � OL a 3 O � � O QL � � REVISIONS o, I&SUE I 21 Jul� 0 SHEET NO. /Aix—,I