13-240-033GENERAL PLUMBING NOTES 1. ALL WORK SHALL CONFORM WITH ALL LOCAL, STATE, FEDERAL 7. PROVIDE MEANS "FURNISH AND INSTALL ". ORDINANCES AND BUILDING CODES GOVERNING THE • C INSTALLATION OF THE PLUMBING SYSTEM. IF WORK AS LAID d. DO A COMPLETE JOB, EVERYTHING CONNECTED, READY FOR USE. OUT, INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS • • WITH LOCAL ORDINANCES, BUILDING CODES AND REGULATIONS, 9. SHOP DRAWINGS: CONTRACTOR SHALL FURNISH THE ENGINEER THE CONTRACTOR SHALL REPORT IN WRITING TO THE WITH SHOP DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE ARCHITECT /ENGINEER BEFORE SUBMITTING A BID. THE FOR APPROVAL. ARCHITECT /ENGINEER WILL THEN ISSUE INSTRUCTIONS AS �.� 12 0 HOW TO PROCEED. 10. AT COMPLETION OF JOB THE PLUMBING CONTRACTOR SHALL r•• GIVE THE OWNER AN AS -BUILT SET OF REPRODUCIBLE SEPIAS 2. THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT SHOWING THE EXACT LOCATION OF ALL INSTALLATIONS. NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE MINOR ITEMS. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE 11. PLUMBING CONTRACTOR SHALL PRESSURE TEST ALL PIPING AS STRUCTURAL, ARCHITECTURAL AND SITE CONDITIONS SHALL REQUIRED BY CODE. TEST SHALL BE WITNESSED AND APPROVED GOVERN THE EXACT LOCATIONS. CONTRACTOR SHALL FOLLOW BY PROPER AUTHORITIES. DRAWINGS IN LAYING OUT WORK, CHECK DRAWINGS OF ALL . TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED 12. THE PLUMBING CONTRACTOR SHALL WARRANT ALL AND MAINTAIN MAXIMUM HEAD ROOM, AND SPACE CONDITIONS WORKMANSHIP AND MATERIALS FOR ONE YEAR FROM THE DATE AT ALL POINTS. WHERE HEAD ROOM, OR SPACE CONDITIONS OF FINAL WORK ACCEPTANCE BY OWNER. ANY BREAKDOWN APPEAR INADEQUATE, ARCHITECT/ ENGINEER SHALL BE OCCURRING IN FIRST YEAR SHALL BE REPAIRED AT NO EXPENSE NOTIFIED BEFORE PROCEEDING WITH INSTALLATION. THIS TO THE OWNER. CONTRACTOR SHALL, WITHOUT EXTRA CHARGE, MAKE FIELD MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT 13. PROVIDE BATHROOM FIXTURES AS SPECIFIED. WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION 1 ST ISUUE OF THE WORK . 14. PROVIDE SHUT -OFF VALVE FOR EACH FIXTURE. 3. EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBMITTING A BID, 15. WHEREVER NOT SIMILAR METALS ARE TO BE JOINED, CONTRACTOR WILL BE REQUIRED TO FURNISH, INSTALL AND /OR A DI- ELECTRIC FITTING SHALL BE PROVIDED TO CONNECT BOTH CONNECT WITH APPROPRIATE SERVICES ALL PLUMBING ITEMS TYPES OF PIPES. SHOWN ON ANY OF THE ARCHITECTURAL, AIR CONDITIONING, ELECTRICAL AND SPRINKLER DRAWINGS WITHOUT ADDITIONAL 16. PLUMBING CONTRACTOR SHALL PROVIDE AIR CONDITIONING EXPENSE TO THE OWNER, IF DISCREPANCIES ,CONFLICTS , CONDENSATE DRAIN AND TRAP. SEE AIR CONDITIONING PLANS INTERFERENCE OR OMISSIONS OCCUR BETWEEN DRAWINGS, FOR LOCATION OF UNITS AND DRAINS. NOTIFY IN WRITING THE ARCHITECT/ ENGINEER IN AMPLE TIME 17, MATERIALS TO PERMIT REVISIONS BEFORE THE BIDS ARE SUBMITTED, � r • A. COLD WATER PIPING DOWNSTREAM OF WATER METER SHALL BE 4. INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST TYPE "L" COPPER BELOW GROUND AND TYPE "M" COPPER ABOVE CLASS WORKMANLIKE MANNER. THE OWNER RESERVES THE GROUND, RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ITEMS WHICH, B. COLD WATER PIPES INSIDE OF SLAB SHALL BE TYPE "K" SOFT IN HIS OPINION, DO NOT PRESENT A NEAT AND WORKMANLIKE COPPER INSTALL INSIDE POLYETHYLENE CONDUIT. NO JOINTS APPEARANCE. REMOVAL AND REPLACEMENT IS TO BE DONE PERMITTED INSIDE SLAB. IMMEDIATELY WHEN DIRECTED BY THE OWNER IN WRITING, AT THE SOLE EXPENSE OF CONTRACTOR. C. SANITARY WASTE AND VENT 4 "I AND SMALLER SHALL BE P.V.C., SCHEDULE 40, 5. START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS D. STORM LINES INSIDE BUILDING SHALL BE P.V.C. SCHEDULE 40 ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO SUITABILITY OF THE WORK OF OTHER. TRADES OR OTHER E. IN COASTAL AREAS ALL SANITARY AND STORM PIPING OUTSIDE OF CONTRACTORS To RECEIVE HIS WORK. THIS CONTRACTOR BUILDING SHALL BE SCHEDULE 40, PVC, SHALL REMOVE AND REPLACE, AT HIS EXPENSE, ALL PLUMBING F. CONDENSATE DRAIN PIPE SHALL BE SCHEDULE 40, PVC PIPE WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF AND FITTINGS. INTERFERENCE WITH OTHER TRADES, G. WATER HEATER RELIEF AND DRAIN LINE SHALL BE TYPE I" COPPER, 6. THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE, MIN 314" DIA. FEES, PERMITS , ASSOCIATION DUES, ROYALTIES AND TAXES OF WHATEVER NATURE SHALL APPLY TO THIS WORK. HE SHALL ALSO FIRE RATED PENETARATION NOTE PAID ALL THE INSPECTION FEES AS MAY REQUIRED BY LAW OR ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY WHEN FIRE PENETRATION OF PIPING OCCUR, SHALL BE PROTECTED DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF LAWS, BY ASSEMBLY No. W- L -208C, UL APPROVED RULES OR ORDINANCES. EXAMINATION OF CONTRACT DOCUMENTS AND SITE OF WORK: THE BIDDER IS REQUIRED, BEFORE SUBMITTING HIS PROPOSAL, TO VISIT THE SITE OF THE PROPOSED WORK AND FAMILIARIZE HIM OR HERSELF WITH THE NATURE AND EXTENT OF THE WORK AND ANY LOCAL CONDITIONS THAT MAY IN ANY MANNER AFFECT THE WORK TO BE DONE AND EQUIPMENT, MATERIALS AND LABOR REQUIRED THEREFORE. SINCE THE WORK INVOLVES NEW AND /OR EXISTING BUILDINGS, SYSTEMS AND FACILITIES, SPECIAL CONSIDERATION SHALL BE GIVEN TO EXAMINATION OF WORKING CONDITIONS, NEW FACILITIES AND ALL BUILDING STRUCTURES FAMILIARIZE TO HIMSELF WITH ALL EXISTING CONDITIONS. SLIGHT VARIATION OF ROUTING AND OR CONSTRUCTIONS SHOULD BE ANTICIPATED BY THIS CONTRACTOR TO AVOID CONFLICTS WITH OTHER TRADES, THESE VARIATIONS ARE EXPRESSLY INCLUDED AS PART OF THE WORK WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER. IGNORANCE ON THE PART OF THE CONTRACTOR WILL IN NO WAY RELIEVE HIM OF THE OBLIGATIONS AND RESPONSIBILITY ASSUMED UNDER THIS CONTRACT. HAM)IER ARRESTOR: - AMTROL, MODEL 500 - INSTALL IN ACC. LOCATION. -- CONNECTION SIZE: 112" NPT - HEIGHT: 4 -112" DIAMETER.. 3-318" MAX. PRESSURE: 150 PSI MAX. TEMP: 200' F MAX. SHOCK PRESSURE: 200 PSI TO BE INSTALLED IN CWS AND HWS HIGH POINT FOR EACH GROUP OF FIXTURE SERVICING. NOTE: ALL SANITARY PIPE 2 1 /2 "/ OR SMALLER SHALL RUN 0 114" SLOPE PER L.FT, 3" AND LARGER 0 1 18" SLOPE PER L.FT. LEGEND: O. H - OVER HEAD U.S - UNDER SLAB U.G - UNDER GROUND V.E.L.F- VERIFY EXACT LOCATION AT FIELD LEGEND: 0. H -- OVER HEAD U. S - UNDER SLAB U.G — UNDER GROUND V. E. L. F— VERIFY EXACT LOCATION AT FIELD NOTE: NOTE: ALL PIPES TO DISCHARGE ALL TUB AND SHOWER SHALL BE MIN. 12" FROM STRUCTURE ANTISCALDING VALVE 0 110', (TYPICAL) NOTE: NOTE: ALL PLUMBING WATER DEVICE PROVIDE WATER HAMMER ARRESTOR AT PROVIDE SHUT -OFF VALVE. WASHER MACHINES IN ACCESS LOCATION. NOTE: NOTE: ALL VTR SHALL BE OFF SET PROVIDE OPEN FULL VALVE BY THE A MIN. OF 4' -0" FROM FIRE WATER METER IN CONCRET BOX (EXACT SEPARATION WALL. LOCATION ®FIELD.) WATER PIPING SIZE -2 ( 112 "0 CW/HW Q 1/2 "0 C 3 3/4 "0 CW, 1/2 "0 HW ® 1/2 "0 HW Q 3/4 "0 CW, 3/4" HW Qb 1 "0 CW, 3/4" HW Q 3/4 "0 C 1 "0 CW Q 1 "0 CW, 1/2 "0 HW 1�! 1 -1/4 "0 CWS 1 1 1 -114 "0 CW, 112 "0 HW . WC \ B L 1- 1 -/ "N (fn))- 0(2FU) SH 3 "0(2FV 3 "0(4FU) MASTER BATH MASTER I1�_>I W.I.C. I� - I I I L---- - - - - -- 3 "0(8FU) 3 "0(10FU) 2 MASTER BEDROOM 2 M rol I Co WM/ 3 "/(2FU) 2 "�(1FU) 1 L RO RY 3 "/(3FU) olo 7f TERRACE 2"0 VFR 11 a w;ml ql H I I P,L- IL 11 MICRO 0 "M(1 FU) "0(3FU) STOVE 2 "iAAV •• r G V W• �+ W V W•• 1 ••• • • C Wi GW r • • ••• • • • W V U Y W • • C r G W u•••• �.� 12 0 r•• ••• • rr rr•W G W • U n �• I Revisipns • .. • . • AX ' Z6001560 6001 560 Sheet No. 1 ST ISUUE P_1 ,3.C613 y W • • r • V • • • • V r • G • • A • • V�V v r••• Y W � r • . G3 G G \- 3 "0(13N) f REF \ / — tO�MVJ 7T T 3 — ) - "i14 T "J 0 7FU) � 7/// � iiiiiiiiii �i, ol y a-7z— ,/ / / / / / / /ZEE D� Tw EAS % Cf LO ET � N B 0 R100'Al 71 NEW PORCH /P� /� / / / /� � / / /� � / / / SANITARY PLUMBING PLAN) SCALE: 1/4"= l'-O" FCO I � \ S° e? i2 W) ° ` \avnvo `fit F,uo 5�� "e F� 1 6A South M 4 "0(31 FU) TO BE CONN. To SEPTIC SYSTEM (SEE P -0) � ZL • ■ Cc w �. 00 � w w Cc U) O co Cf) z W - ❑_ 0 �.� 12 0 U) U n 's' _ U J C Q U Z Mz .. N 4 0 C�LL U OW E dm W 0C ca ■. 3 U) u > TWO 0 �a G O� W�a Q � - U +A� U,vl v/ � d � a� z 43 L� u aW �W C � 7 J Q r M- --� u - � , Job No. Date Scale SHOWN 's' _ AX ' Z6001560 6001 560 Sheet No. P_1 y W •