10-934-009ETR ETR ETF ETF ETF ETF ETF ETF ETF ETF ETF ETF ETF ETF ETF ETF ETF 0 0 PANELBOARD: A EXISTING EQUIPMENT GROUND BUS BUS AMPS: 225A MAIN SIZE /TYPE: MLO SERVES: GENERAL POWER VOLTS /PHASE: 208Y/12OV, 3PH, 4W MOUNTING: SURFACE SECTION: 1 LOCATION: ELECTRICAL ROOM CKT NO. DESCRIPTION VOLTAMPS PHASE WIRE NO. BKR AMP P P BKR AMP WIRE N0. VOLTAMPS PHASE DESCRIPTION CKT N0. A B C A B C 1 INTERNET ST EPSON PRINT 360 f,° / /r 0.00 20 1 1 20 TOTAL LOAD 480 ' i r' " /,. MONEYGRAM EXPRESS ST 2 3 CREATIVE ST/PRINT/SCAN i 660 AMPS 800.0 20 1 1 20 e ' ; r' "m 480 ////,"-72 GREETING CRDS PYNK 4 5 EXISTING LOAD '- '��; r'.! 540 20 1 1 20 `_T; ; r '° 756 6850 PRINTERS 6 7 PLUGMOLD 720 iji'fi; °' /'. ;: PNLBD 20 1 1 20 C 600 '. r'.r:. ' / -' -/ 8810 PRINTER 8 9 CASH WRAP i / 360 ELECTRICAL ROOM 20 1 1 20 A -9 r'. °% 600 EXISTING LOAD 10 11 IDL PRINTER rir '/ f'° 900 10 20 1 1 20 ' ` '_- f 540 POWER POLE 12 13 BACK ROOM 360 ;r ' //, ,° i; /' 20 1 1 20 540 r �; ,- '�' /,� POWER POLE 14 15 PLUGMOLD ' "r:a /f 720 20 1 1 20 ' 540 ! f POWER POLE 16 17 REC CASH WRAP , 320 20 1 1 20 ', fr; %° /f 600 EXISTING LOAD 18 19 REC CASH WRAP 360',' ° ?- r,/ 1 20 1 1 20 1 300 EXIT LIGHTS 20 21 EXISTING LOAD 1 600 20 1 1 20 r: 750 RESTROOM 22 23 EXISTING LOAD , ,° i 540 20 1 1 20 ' 'f` 600 EXISTING LOAD 24 25 1EXISTING LOAD 540 ' /! EXISTING LOAD 26 27 EXISTING LOAD / 600 r; f 20 1 1 20 600 r 'Fff EXISTING LOAD 28 29 EXISTING LOAD /'; /", 540 20 1 1 20 r'. " "X/ 900 COOLER FANS 30 31 EXISTING LOAD 600 ,',t'. ; /, !, 20 1 1 1 20 600 EXISTING LOAD 32 33 LANDSCAP LIGHT ;r,, `i/ 300 /:rj 20 1 1 20 r, fi, 600 !% EXISTING LOAD 34 35 E.M.S ;° ' -' d !``- 100 20 1 2 40 r`i 2,400 EXISTING LOAD 36 37 EXISTING LOAD 650 20 1 2,400 '7 1 38 39 EXISTING LOAD /° 650 '. °; ,,;' 20 1 1 20 10 ' ,� °`'°'` _ , 900 ' �� °` t'° APEX KODAK 40 41 EXISTING LOAD , ' ' ' .� 177777 ­� 650 20 1 1 20 I `'71,7771, , r 71 , i' % FUTURE LIGHTS 42 SUBTOTAL 1 3,590 1 3,890 1 3 590 5,520 1 4,470 1 5,796 SUBTOTAL TOTAL PHASE A - VA 9,110 LOAD CONN. VA OF LOAD CONN. VA OF TOTAL DEMAND 26,856 VA 75 A AMPS 76 COOLING 1.00 REFRIGERATION 1 _ TOTAL PHASE B - VA 8,360 HEATING LIGHTING RECEPTACLES MOTORS_ -_ SUPP HEAT MISC EQUIP _ _ 5,496 0 1.25 1.0/.5 1,00 1.00 1.00 SIGN DISPLAY KITCHEN EXISTING LARGE MOTOR V 21,360 1.25 1.00 _ 1.00 1 25 AMPS 70 TOTAL PHASE C - VA 9,386 1 AMPS 78 TOTAL PNLBD - VA 26,856 SHOW WINDOW 1.25 AMPS 75 ILTG TRACK 1.00 PANELBOARD NOTES ETR - EXISTING TO REMAIN LTG TRACK - TRACK LENGTH SIGN DISPLAY - SIGNAGE & DISPLAY CASE TENANT ELECTRICAL SERVICE LOAD SUMMARY TENANT OCCUPANCY TYPE: M TENANT SQUARE FOOTAGE: 13,895 SERVICE DESCRIPTION: 208Y 12OV, 3PH LOAD DESCRIPTION Connected KVA Demand I FACTOR Demand KVA p AREA: a PHARMACY AREA: LIGHTING R NEC -220 41.69 12 % 52.11 RECEPTACLES 0.00 10076,50% 0.00 MISCELLANEOUS EQUIPMENT 5.5a 0 000 Sr SHOW WINDOW TRACK LIGHTING 0.00 PER NEC 0.00 EXISTING LOAD TO BE DELETED 8.30 100%1 8.30 TOTAL LOAD 68.68 KVA 49.30 TOTAL AMPACITY 107.92 AMPS 136.85 SERVICE AMPACI Y 800 AMPS 800.0 SPARE CAPACITY AMPS 663 SCOPE OF WORK THE SCOPE OF ELECTRICAL WORK SHALL INCLUDE, BUT IS NOT LIMITED TO THE FOLLOWING: 1. IDENTIFY ALL THE CIRCUITS BEING FED FROM EXISTING PANELS, WHICH ARE BEING REUSED FOR RENOVATIONS IN PHOTO LAB, AND FOR THE REMOVED POWER POLES. 2. ELECTRICAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS PRIOR TO BID & INSTALLATION. INFORM ENGINEER OF RECORD OF ANY DISCREPANCY BETWEEN THE DOCUMENTS & THESE CONDITIONS & HE SHALL INCLUDE IN HIS BID TO CORRECT THE SAME AS DIRECTED. THE ENGINEER & ARCHITECT ARE NOT RESPONSIBLE FOR ANY ADDITIONAL COSTS RESULTING FROM VERIFIABLE EXISTING CONDITIONS DISCOVERED AFTER THE CONTRACT HAS BEEN AWARDED. 3. ELECTRICAL CONTRACTOR SHALL KEEP AS- GUILTS AND SUBMIT TO ENGINEER OF RECORD FOR REVIEW. ALL CHANGES SHALL BE FORWARDED A MINIMUM OF (2) WEEKS PRIOR TO FINAL INSPECTION. ANY EXPENSES, SUCH AS REVISIONS OR AS- BUILTS, NECESSARY FOR FINAL C.O. SHALL BE AT THE EXPENSE OF THE OWNER. NOTE: VERIFY ALL EXISTING CONDITIONS IN FIELD PRIOR TO CONSTRUCTION. POWER RISER IS EXISTING TO REMAIN. _TR JR :_'TR _TR 7-TR _TR -_TR -TR -_TR ETR _TR ETR _TR 21110 e- PROVIDE QUADPLEX RECEPTACLE FLUSH MOUNTED IN E1 MILLWORK 18" ABOVE FINISHED FLOOR. t)- PROVIDE QUADPLEX RECEPTACLE FLUSH MOUNTED IN WALL 18 » ABOVE FINISHED FLOOR. PROVIDE JUNCTION BOX ABOVE FINISHED CEILING FOR FUTURE LIGHTS. AT - TELEPHONE OUTLET. PROVIDE JUNCTION BOX IN WALL AND 3/4" CONDUIT WITH PULL WIRE IN WALL STUBBED ABOVE FINISHED CEILING. AD - PROVIDE DATA LINE. PROVIDE JUNCTION BOX IN WALL AND 3/4" CONDUIT WITH PULL WIRE IN WALL STUBBED ABOVE FINISHED CEILING (} DUPLEX OUTLET, 20 AMP. 20 AMP. "LEVITON" #5262 -SGI (IVORY) w/ METAL PLATE UNLESS OTHERWISE NOTED. SEE THE ELECTRICAL NOTES. 4GFI GROUND FAULT INTERRUPTER DUPLEX OUTLET DBL. DUPLEX OUTLET Q JUNCTION BOX ELECTRICAL SPECIFICATIONS 1. REFER TO THE ARCHITECTURAL PLAN AND ELEVATIONS FOR EXACT LOCATION OF ALL EQUIPMENT AND CONFIRM WITH OWNERS REPRESENTATIVES. 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITIONS OF THE NATIONAL ELECTRICAL CODE, NFPA 101, NFPA 72, AND THE FLORIDA BUILDING CODE. 3. UNLESS OTHERWISE NOTED, ALL CONDUCTORS SHALL BE COPPER, WITH "THWN -2" INSULATION FOR SIZE #10 AND SMALLER. CONDUCTORS LARGER THAN #10 SHALL HAVE "THWN -2" INSULATION. ALL CONDUCTORS #10 AND SMALLER MAY BE SOLID. ALL CONDUCTORS #8 AND LARGER SHALL BE STRANDED. ALL CONDUCTORS MUST COMPLY WITH ARTICLE 310 OF THE NATIONAL ELECTRICAL CODE. 4. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET LOCATIONS AND SPECIAL ENCLOSURES FOR OTHER CLASSIFIED AREAS. 5. THESE PLANS DO NOT SHOW EVERY MINOR DETAIL OF CONSTRUCTION, THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND MEET ALL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. 6. THE ELECTRICAL SYSTEM SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED AS REQUIRED IN ARTICLE 250, NATIONAL ELECTRICAL CODE. 7. ALL MATERIALS SHALL BE NEW AND SHALL BEAR U.L. LABELS WHERE APPLICABLE. 8. ALL WORK SHALL BE PERFORMED BY A LICENCED ELECTRICAL CONTRACTOR IN A FIRST CLASS WORKMANSHIP MANNER. THE COMPLETE SYSTEM SHALL BE FULLY OPERATIVE AND ACCEPTANCE BY ENGINEER /ARCHITECT MUST BE A CONDITION OF THE SUBCONTRACTOR. 9. CIRCUITS SHOWN ON PLANS ARE TO DETERMINE LOAD DATA AND PANEL SIZE. THE CONTRACTOR SHALL PROVIDE CIRCUITS TO SUIT JOB CONDITIONS. 10. SEE NOTES ON PLANS FOR OTHER REQUIREMENTS. 11. FURNISH AND INSTALL LIGHTING FIXTURES AND LAMPS AS CALLED FOR ON PLANS, OR AS SELECTED BY OWNER. 12. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROCESS OF CONSTRUCTION. 13. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY PHASE OF THE INSTALLATION WHICH MAY BE DAMAGED. 14. ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBLIC LIABILITY OF PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 15. CHECK ALL EQUIPMENT FOR PROPER VOLTAGE, PHASE, AND CURRENT BEFORE CONNECTION TO CIRCUITS. 16. ELECTRICAL CONTRACTOR SHALL CHECK AND VERIFY EQUIPMENT FURNISHED AGAINST THOSE SPECIFIED OR INTENDED AND REVISE BRANCH CIRCUITS AS MAY BE REQUIRED WITH PRIOR APPROVAL OF ENGINEER /ARCHITECT. 17. ALL NEW CIRCUIT BREAKERS SHALL BE OF SAME MANUFACTURER AND AIC RATINGS AS THE EXISTING PANELBOARD. ELECTRICAL ONE -LINE DIAGRAM , -_ p J. __ I r TOTAL STORE i _'UTILITY TRANSFORMER RETAIL AREA: PHARMACY AREA: I A -4 A -6 SF D 000 SF A -2 AREA: 1 '(EXISTING) 000 CIRCUITS FOR POS AND CREATIVE STATIONS 000 Sr RECEIVING AREA: L __1 SHALL BE TRENCHED FROM WALL TO PROVIDED 000 SF N A SF4 METER MILLWORK AND PROVIDE FLEX CONDUIT TO FLUSH M MOUNTED DEVICES. COORDINATE INSTALLATION MQP (EXISTING) e 800 AMPS 208/120V 30 T__ r I 150A C C A C OA C 3P A C 3P P 313 3P = EXISTING EXISTING EXISTING EXISTING EXISTING . PNLBD PNLBD PNLBD PNLBD PNLBD A B C AC s 208/120V 208/120V 208/120V 208/120V 208/120v ELECTRICAL ROOM ELECTRICAL ONE -LINE DIAGRAM c R66ert Reid Weddipig Architects & Planners, AIA;.Inge. f .a� 4112 Cypress Street Tampa, Florida 33607 - 813-879996 612 South Military Trail - Deerfield Beach, Florida 33442 - 954492 -99801 > "T Florida License Irs: ArchitamteAntedor Design: AA- 0001123 - Engineeti.*002655 CONSULTANT: HENDERSON HOMMMiMMS ENGINEERS ING a� 8325 LENEXA DRIVE LENEXA, KS 66214 TEL 913 742 5000 FAx 913 742 5001 , www.bei.ong.com 1050001121 FL CORPORATE NUMBER: EB 7606 EXPIRES 02/28/11 1970 Y S 2010 • STATE OF g t, vs/1--_` U_ ffQ% NUMB 50', 6460 S. DIXIE HWY SOUTH MIAMI, FL 33143' PROJECT TYPE: CS NUMBER t PL CAP CO : r AREA CALCULATIONS , -_ p J. __ I r TOTAL STORE I RETAIL AREA: PHARMACY AREA: I A -4 A -6 SF D 000 SF A -2 AREA: MEZZANINE ,AREA `. 000 CIRCUITS FOR POS AND CREATIVE STATIONS 000 Sr RECEIVING AREA: SHALL BE TRENCHED FROM WALL TO PROVIDED 000 SF N A SF4 MILLWORK AS INDICATED. STUB UP INTO MILLWORK AND PROVIDE FLEX CONDUIT TO FLUSH MOUNTED DEVICES. COORDINATE INSTALLATION WITH MILLWORK PROVIDER PRIOR TO TRENCHING, e T__ r I .. _ A -42 _ �< ;; ° i A - 1 = s- . A -40 . I A -3 A -9 i ;I D' r, I i I k , co 1 PHOTO LAB POWER PLAN E- 2 SCALE: 1/4"=11'-O" , b ;z c R66ert Reid Weddipig Architects & Planners, AIA;.Inge. f .a� 4112 Cypress Street Tampa, Florida 33607 - 813-879996 612 South Military Trail - Deerfield Beach, Florida 33442 - 954492 -99801 > "T Florida License Irs: ArchitamteAntedor Design: AA- 0001123 - Engineeti.*002655 CONSULTANT: HENDERSON HOMMMiMMS ENGINEERS ING a� 8325 LENEXA DRIVE LENEXA, KS 66214 TEL 913 742 5000 FAx 913 742 5001 , www.bei.ong.com 1050001121 FL CORPORATE NUMBER: EB 7606 EXPIRES 02/28/11 1970 Y S 2010 • STATE OF g t, vs/1--_` U_ ffQ% NUMB 50', 6460 S. DIXIE HWY SOUTH MIAMI, FL 33143' PROJECT TYPE: CS NUMBER t PL CAP CO : r AREA CALCULATIONS r TOTAL STORE AREA: 13,865" SF RETAIL AREA: PHARMACY AREA: 11.220+/- SF 000 SF SERVICE AREA: MEZZANINE ,AREA `. 000 SF 000 Sr RECEIVING AREA: SUBLEASE' %ARIM. 000 SF N A SF4 REVISIONS: PROJECT MGR.: RS LAYOUT COORD. PROJECT ;ARCHITECT: RRW °LANNING MGR. RS DRAWING BY: JM 6 DATE:. 05 QCT 2010 DRAWING SCALE AS NOTED TITLE: ELEC"'riRICAL PLAN AND 140TES ,SHEET NUMBER: E -2 „ COMMENTS: PERMIT SET DOW PROJECT N0: 10104