12-279R-0046 IN. z — III — III —III —III III - III -1II- 111-11 REFRIGERATION PIPING — PIPE INSULATION FLP ry PVC SCHD. 40 I III I III I II I I —i I I -1111 CONTINUOUS PIPE SLEEVE III— BENDS ® 45' ELBOW REFRIGERANT PIPE DETAIL SCALE: N.T.S. AIR DUCT 4/M -1 SPACE �I STUDS ® 24" O.C. REFRIGERATION LINES FILTER /FAN ACCESS PANEL NOTE: SS MODEL 17485 # BOLT CONDENSING UNIT TO CONC. PAD TO LOAD 160 LBS. WITHSTAND 146 MPH HURRICANE FORCE WINDS. HEATER ACCESS PANEL COIL ACCESS PANEL 1/4" SS COATED CABLE SEER SECURE PER DADE TOTAL SENSIBLE COUNTY ORD. 8 C -5 1/4" WIRE /ROPE PROVIDE METAL SUPPORT BY 1 1/4" P.V.C. W OTHER COND. DRAIN W/ TRAP AND UNION PROVIDE LOW VOLTAGE CONS. W/ CLEANOUT OVERFLOW SHUT -OFF SAFETY SWITCH MODEL # S52 BY SMD NEW RESERCH INC. FLOAT SWITCH REFRIGERANT LINE 1" A/C CLOSET INSTALLATION DETAIL SCALE: N.T.S. 2 -1/4 TURNBUCKLES NOTE: SS MODEL 17485 # BOLT CONDENSING UNIT TO CONC. PAD TO LOAD 160 LBS. WITHSTAND 146 MPH HURRICANE FORCE WINDS. CONDENSING UNIT 1/4" SS COATED CABLE SEER SECURE PER DADE TOTAL SENSIBLE COUNTY ORD. 8 C -5 1/4" WIRE /ROPE VOLTS PHASES HTNG KW WIRE AMPS CLAMPS GROOVED LIQ. SUC. COND. CU -1 850 ELEC. POWER SUPPLY CLAMPS HOLDS CABLES 67 80 230 1 11 CONNECTIONS 6 CONC. CAST GOODMAN DSXC 160361 A 16 318 LIQUID LINE W/O IN PLACE ® SAME UC UNDERCUT DOOR FOR AIR RETURN Z INSULATION HEIGHT AS MAIN to U > 3� FLOOR W SUCTION LINE W/ 1/2" CHAIN LINK, 1/4" ARMAFLEX INSULATION 1/4" STOCK & VAPOR BARRIOR 2-1/4" LONG Q MODEL 12895 LIQUID & SUCTION PIPING IS ABOVE GRADE, SEE PLAN. 5/16-X4" LAG EYEBOLTS Q SS ® EACH CABLE END PROVIDE ANCHORED BOLTS TO PREVENT Uu THEFT PER DADE COUNTY ORD. 8C -5 CONDENSING UNIT DETAIL SCALE: N.T.S. SEAL GAP BETWEEN SLEEVE AND DUCT W/ EXPANSION FOAM AND CAULK TO DRYWALL VENT DUCT 4" DIA. AL. 26 GA. MIN. SHEET METAL DUCT. UL /81 CLASS LOUVERED VENT COVER W/ NO SCREEN - SCREW TO 2X4 BLKG DRYER BEHIND STUCCO 4 1/2" MIN. DIA. HOLE THROUGH ICF SYSTEM - G.C. TO BLOCK OUT HOLE 4" FLEX DUCT BEFORE POURING HOSE CLAMP CONCRETE DRYER EXHAUST DETAIL SCALE: N.T.S. R -6 FLEX DUCT AIR INTAKE - DUCT SIZE PER MECH. PLAN. CONNECT OA DUCT TO AHU RA INTAKE SCALE: N.T.S. TRANSITION TO 4 "X8" SS DUCT THRU SOFFIT FIBERGLAS DUCT 2 1/2" SQ. WASHER 1 "X3" 22 GA SHT MTL -- ® 12" O.C. MIN. 2 /SIDE SELF TAP SCREW #10 X 1 1/4" SHT. MTL SCREW GFM CLOSURE ¢AIR HANDLER DUCT TO AHU SCALE: N.T.S. LOW VELOCITY SUPPLY MTL ROUND FITTING QUADRANT OPERATOR TO BE OUTSIDE INSULATION PROVIDE INSULATION GUARD AS REQUIRED R -6 INSULATED FLEXIBLE DUCT SEAL ALL JOINTS W/ MASTIC PERFORATED DIFFUSER FAMCO 6" GALV. DAMPER WALL VENT W/ j" INSECT SCREEN & EXTRA LONG THROAT. VERIFY DIRECTION OF BDD SET TO INTAKE - COORDINATE INSTALLATION W/ ICF INSTALLER - PROVIDE SLEEVE THRU CONCRETE SCALE: N.T.S. PROVIDE 1" METAL STRAP GAUGE 16 FOR ALL DUCT HANGER INSIDE ATTIC. ATTACHED TO STRUCTURE W/ �R'�0w BOLTED CONN. PROVIDE 1" SHEET METAL BAND CLAMP ATTACH TO STRUCTURE W /10d NAILS 1 1/2" FORMED SHEET METAL GAUGE 16 BAND CLAMP EXHAUST FAN SCHEDULE TYPE DUCT VERT. NUTONE MODEL # 606 ENERGY STAR SIZE 4" DISCHARGE 50 CFM SLOPED ROOF CAP. —WIRE MESH TERMINATION PROOF 4" METAL DUCT EXH. FAN - - --- - -- -- - -- WITH /D -- - - - - - -- - - -- - - - - -- -- - -- - CEILING -- AIR AIR GRILLE SCALE: N.T.S. GENERAL H.V.A.C. NOTES 1. The contractor shall furnish all labor, material and equipment for a complete H.V.A.C. system in accordance with these drawings. The Florida Building Code 2007/2009 and the latest edition of the following publications: (a)ANS B9.1 Mechanical Refrigeration (b) NFPA Pamphlets 90A & 91 (c) SMACNA (d) ASHRAE. 2. All air conditioning ductwork shall be 1 112 " standard duty foil reinforced fiberglass (R -6) manufactured logo printed on the vapor barrier. 3. All exhaust ductwork shall be code gage galvanized sheet metal. 4. Duct sizes shown are net free area inside. 5. All air devices diffusers, registers and grilles) shall be all aluminum cons ruction, with exposed surface chemically treated to receive paint to match color or AIRGUIDE or approved equal. with minimum 75% free area. 6. Provide opposed blade dampers at all diffusers and registers. 7. Thermostats shall be combination cooling /heating with system Cool /Auto /Heat /Off and Fan On /Auto selector switches. 8. Refrigerant pipingg shall be copper type "L" with 314" ormoflex. Insulation shall be provided for suction lines. 9. Provide new filters for fan coil before starting. These filters must also be replaced prior to final acceptance by owner. rJ X w Z Iz L C) DR11 SE rT� SH L_ 9P\100M 2 KEEP DUCTS LTLITY CLEAR OF ATTIC ACCESS PANEL I L- +�I 6 "x10" CEILING i �y 67CFMDIFFUSER RA 4 "DIA 4"q4" CEILING D I FFU EF -1 50 BATH 2 ° VII J 6 "x10" CEILING DIFFUSER 191CFM � MOO�Ci�I 6"X10" CEILING DIFFUSER 170CFM RA DI 17W A X CU r. NOTE. THIS IS A SEALED ATTIC. LOCATE (1) 150 CFM 6"X10" SUPPLY REGISTER IN ATTIC. SPRAY FOAM INSULATION TO BE INSTALLED ON UNDERSIDE OF ROOF SHEATHING. SEE SECTION A -2 SCALE: 1/4"=-19-0" I IQUIn/ 5LCTION Q EF -1 W.I.C. MA5Tck (� 1 ]oD 6" PATH �'� 6 "x6" ILING ° CEILING CFME R l l 57CFMER 4 "DIA "DIA 8 "x10„ �^- CEILING DIFFUSER 150CFM 'DIA MA5S1 13'rPF\00M I RA, D 2F. 267CF L_ s "DIA i i 8 "x10" CEILING DIFFUSER ME0 247CFM f71N'NG KITCHEN 6 "DIA F WO 8 "DIA .I 6 "x10" CEILING DIFFUSER G�cAt 71CFM DOOM I �OYI;p II 8 "x10" / l CEILING DIFFUSER 247CFM / CONDENSING UNIT 1 DESIGNATION CFM MBTUH ENTERING F ELECTRICAL DATA MANUFAC. REF. UNIT SEER OBS TOTAL SENSIBLE WB DB VOLTS PHASES HTNG KW WIRE AMPS FUSES LIQ. SUC. COND. CU -1 850 34.6 24.9 67 80 230 1 11 25 30 GOODMAN DSXC 160361 A 16 318 7/8 1 AIR HANDLING UNIT 1 DESIGNATION MBTUH TEMP. ENT. CONDENSER ELECTRICAL DATA MANUFAC. REF. UNIT OBS OR SEER AREA SERVED VOLTS PHASES WIRE AMPS FUSES AHU -1 36.0 90 230 1 18.6 25 GOODMAN CA *F3642 *6D *TVX 16 1570 DRYER VENT NOTES: 1. CLOTHES DRYER EXHAUST TO BE 30 GA, MIN. 2, CLOTHES DRYER EXHAUST-NO PR❑TRUSI ❑NS INSIDE DUCT 3. CLOTHES DRYER EXHAUST SHALL BE MIN, 4' DIA. 4, CLOTHES DRYER EXHAUST SHALL NOT BE SCREENED, 5, CLOTHES DRYER EXHAUST SHALL HAVE BACKDRAFT DAMPER SPACE PROVIDED. SUFFICIENT SPACE SHALL BE PROVIDED ADJACENT TO ALL MECHANICAL COMPONENTS LOCATED IN OR FORMING A •PART OF THE AIR DISTRIBUTION SYSTEM TO ASSURE ADEQUATE ACCESS FOR 1. CONSTRUCTION AND SEALING IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 603.1 OF THIS CODE 2. INSPECTION 3. CLEANING AND MAINTENANCE: A MIN. OF 4" IS CONSIDERED SUFFICIENT SPACE AROUND AIR HANDLING UNIT PER FBC MECHANICAL 603.1.3 HVAC DESIGN CHART HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR (S) J FIRE DAMPER (S) DUCT TO MATCH NECK SIZE TIP. J SMOKE DAMPER (S) QT V FIRE RATED ENCLOSURE AIR FLOW DIRECTION ( ARROWS DENOTE —� FIRE RATED ROOF /FLOOR RETURN OR EXHAUST, SEE PLANS. a FIRE RATED CEILING ASSEMBLY ✓ FIRE STOPPING WALL MOUNTED SIDE REGISTER. 0. nn .. SMOKE CONTROL .. ^.. - J LEGEND Q Ica Z: CEILING GRILLE SEE SIZE SCHEDULE '�" DUCT TO MATCH NECK SIZE TIP. 0 RAG -( RETURN AIR GRILL)) QT THERMOS TA T LO AIR FLOW DIRECTION ( ARROWS DENOTE —� 1 WAY, 2 WAY, ETC., SEE PLANS RETURN OR EXHAUST, SEE PLANS. a Z WALL MOUNTED SIDE REGISTER. 0. nn .. .. •. •. nn .. ^.. - S.R. SIDE REGISTER CD CEILING DIFFUSER CG CEILING GRILLE F•L.D FULL LOUVERED DOOR CU CONDENSING UNIT AHU AIR HANDLER UNIT UC UNDERCUT DOOR FOR AIR RETURN 01001 1 er t,. .... , ��o � ao�nua a�aM� mo uiwa nowt v us Apolon va a� wr S t owtiol► u® at Im JOB No.: 12.06457.SFR REVISIONS: A6-17-13 CU DATE: 3/5/2012 CHECKED BY: DRAWN BY: SRL PLOT: 100% SHEET INDEX: MECHANICAL PLAN NOTES SHEET No.: M -1 � y v Q Z: a Q LO W a Z 0. nn .. .. •. •. nn .. ^.. - - .�J1� O O J Q rM Q o U. CD 00 00 v Z O W to U > 3� W W cc Q V Z O CO Q W Uu LL > O D = D O r 1 Ca p M � O LL CO -J a p 0 = oN Ln a �' .. W 41:r Q Z W O U Cn O Z O G C Q O 01001 1 er t,. .... , ��o � ao�nua a�aM� mo uiwa nowt v us Apolon va a� wr S t owtiol► u® at Im JOB No.: 12.06457.SFR REVISIONS: A6-17-13 CU DATE: 3/5/2012 CHECKED BY: DRAWN BY: SRL PLOT: 100% SHEET INDEX: MECHANICAL PLAN NOTES SHEET No.: M -1 � y v Q a Q LO = O O O J Q rM Q o Z CD 00 00 v W O Z C�I to U > 3� � n CD W Q CU CO O 01001 1 er t,. .... , ��o � ao�nua a�aM� mo uiwa nowt v us Apolon va a� wr S t owtiol► u® at Im JOB No.: 12.06457.SFR REVISIONS: A6-17-13 CU DATE: 3/5/2012 CHECKED BY: DRAWN BY: SRL PLOT: 100% SHEET INDEX: MECHANICAL PLAN NOTES SHEET No.: M -1 � y v