02-279-013
ELECTR I CAL LEGEND SINGLE RECEPTACLE 4,710 SMALL APPLIANCES ------ - - - - -- 3,000 REFRIGERATOR --------------- SINGLE FLOOD - SOFFIT MOUNTED DISHWASHER------------ - - --- 500 DISPOSAL -------------------- DUPLEX RECEPTACLE WASHER--------------- - - - - -- 750 ® 220V RECEPTACLE 6,800 DOUBLE FLUOD - SOFFIT MOUNTED SWITCHED RECEPTACLE RANGE--------------- - - - - -- COMPACT FLUOR. - CEILING MOUNTED WATER HEATER--------- - - - - -- 16,000 SPRINKLER PUMP------- - - ---- GROUND FAULT INT, OUTLET DRYER 48,260 l( 48,260_ FIRST 1OKW 2 100 %----- - - - - -- DS OCCUPANCY SENSOR BAL. C_ 40%----------- - - - - -- COMPACT FLUOR, - WALL MOUNTED WP WEATHERPROOF GROUND 8,040 LED PENDANT W/ GLASS DIFFUSER AFCI ARC FAULT INTERRUPTER AMPS R 240/12OV, 1PH.- - - - - -- -139 AMP GFI GROUND FAULT INTERRUPTER O RECESSED LED HIGH HAT VP VAPOR PROOF 120 NOTES MS MOTION SENSOR Q RECESSED LED WALL WASHER LS LIGHT SENSOR TRACK LIGHT H- --� 24' UNDER CABINET T5 FLUOR. 999 COMPACT FLUOR. - WALL MTD VANITY EXHAUST FAN w /LIGHT 3/4 1t,800 10 MBR LIGHT do REC. SINGLE POLE SWITCH d EXHAUST FAN 15 14 112 • ** 3 WAY SWITCH CD 3 BR 2, HALL, UTIL, LT.JeREC. a 120 H (PROVIDE W VOAT DIMMER LTGE 112 PE ITURES) 0(2 CEILING FAN T TIMER SWITCH 62 I = DISCONNECT SWITCH ` O 120 CIRCULAR FLUORESCENT CEILING FAN w /LIGHT 112 750 O O TV TV JACK 120 15 COMPUTER OUTLET © ELECTRIC PANEL DATA (W/ GENERAL USE DUPLEX RECEPTICLE) SMOKE DETECTOR /CARS, MON, DIET. - PHONE JACK - PREWIRE ONLY S➢ SMOKE DETECTOR /CARS, MON. DET. 12 112 ELECTRICAL NOTES 1) CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT FOR COMPLETE ELECTRICAL INSTALLATION IN ACCORDANCE WITH THESE DRAWINGS, 2) COMPLY WITH THE N.E.C. AND STANDARD BUILDING CODE. 3) PROVIDE EMPTY CONDUITS AS REQUIRED FOR TELEPHONE SYSTEM. 4) OBTAIN ALL PERMITS FOR WORK UNDER THIS CONTRACT. 5) PROVIDE TEMPORARY POWER AND LIGHT OUTLETS FOR USE BY OTHER TRADES. 6) PROVIDE ALL REQUIRED CONNECTIONS FOR OTHER TRADES. 7) COORDINATE ALL OUTLET LOCATIONS WITH BUILDING ARCHITECTURAL FEATURES. 8) CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. 9) ALL CABLE SHALL BE COPPER. 10) INDOOR CONDUITS SHALL BE EMT. 1 1) ALL MOUNTING HARDWARE SHALL BE BY CONTRACTOR. 12) OUTDOOR UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC. UNDER PAVED AREAS IT SHALL BE ENCASED IN CONCRETE. MINIMUM COVER SHALL BE 24 INCHES. CONTROL WIRING TO OTHER SMOKE DETECTORS INSIDE UNIT 120 V. SMOKE SWITCH LEG I IPHASE COND. S. D. SWITCW LINE BIDE OF SWITCH SMOKE DETECTOR DIAGRAM SCALE N.T.S. NOTE 1. SMOKE DETECTORS SHALL BE HARDWIRE (110 VOLT TYPE) TO A NON SWITCH ABLE KITCHEN OR BATHROOM LIGHTING CIRCUIT WITH BATTERY BACK UP AND SHALL NOT BE CONNECTED ONTO THE LOAD SIDE OF GROUND FAULT CIRCUIT INTERRUPTER ALL SMOKE DETECTORS WITHIN EACH UNIT SHALL BE INTERCONNECTED. 2. SMOKE DETECTORS SHALL NOT BE PLACED WITHIN 3 FT OF ANY A/C GRILL OR BATH DR. 3. PROVIDE ARC —FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL 15 AND 20 AMP 125 VOLT BEDROOM BRANCH CIRCUIT OUTLETS. NEC 210- -12 NOTE: ELEC, CONTR. HAS OPTION OF [METHOD A] RUNNING ROMEX W/ PROTECTION PLATES IN CHANNEL TO BE CUT THROUGH POLYSTYRENE EXT. WALLS OR [METHOD B] IN CONDUIT RUN UNDER SLAB AND UP TO DEVICES W/ BOXES MOUNTED PRIOR TO POURING CONCRETE IN ICE WALLS. METHOD A: ROMEX WOULD BE SECURED TO PLASTIC ICF TIES LOCATED AT 6" ON CENTER @ 518" BEHIND SURFACE OF POLYSTYRENE. DRYWALL WILL BE INSTALLED DIRECTLY ON ICF BLOCKS. ALL ELEC. BOXES MUST BE ATTACHED TO CONCRETE LOCATED 1 718" BEHIND SURFACE OF POLYSTYRENE. BOXES MUST NOT BE DEEPER THAN 2 318 ". METHOD B: ALL DEVICE BOXES CUT INTO ICE BLOCKS PRIOR TO CONCRETE POUR MUST BE SECURELY BRACED TO RESIST PRESSURE OF WET CONCRETE. ELECTRICAL LOAD CALCULATION NEW PANEL "A" SQ. FT, -------------- - - - - -- 1,570 GENERAL LIGHTING (3W./S.F.) --- 4,710 SMALL APPLIANCES ------ - - - - -- 3,000 REFRIGERATOR --------------- 1,000 DISHWASHER------------ - - --- 500 DISPOSAL -------------------- 800 WASHER--------------- - - - - -- 750 DRYER----------------- - - - - -- 6,800 MICROWAVE ------------------ 1,500 RANGE--------------- - - - - -- 12,000 WATER HEATER--------- - - - - -- 16,000 SPRINKLER PUMP------- - - ---- 1,200 DRYER 48,260 CONNECTED LOAD1 (LESS A /C) -- 48,260_ FIRST 1OKW 2 100 %----- - - - - -- 10,000 BAL. C_ 40%----------- - - - - -- 15,304 A/C OR HTG, 2 100%---- - - - - -- 8,040 DEMAND LOAD :------- - - - - -- 33,344 AMPS R 240/12OV, 1PH.- - - - - -- -139 AMP PANEL / MCB --------- - --- -- -200 AMP, BATH 1, WIC LIGHTS do REC 120 NOTES ALL SMOKL DETECTORS SHOULD BE NOT LESS 112 3' -0" FROM A/C GRILLS k RELOCATED IF y WN 1 NECESARY. 240 70 4 WET LOCATION NOTES: 1. ALL ELECT. EQUIP. EXPOSED TO WEATHER SHALL COMPLY TO NEC 373 -2 (A) 2. SWITCHES OR CIRCUIT BREAKERS IN WET LOCATION OR OUTSIDE OF A BUILDING SHALL BE ENCLOSLD IN A WEATHERPROOF ENCLOSURE OR CABINET. PER NEC 380 -4 3. NO SWITCHES SHALL BE INSTALLED WITHIN WET LOCATION GENERAL NOTES Location: see Plan NEW PANEL "A" Main BUS 200 AMP 32 SPACE 40 CIRCUIT GE VoI#Age: 1201240 v, 1#,3W Main Breaker. METER COMBO (MCB) Mounting: RECESSED AICS 10,000 GFI- Ground Fault Interrupter NCL= Non— concurrent load REC= Receptacle Ckt Lts= Lighting Ckt ST= Breaker with shunt trip T =Via timer IS= Isolated ground Ckt C= Via contactor SWD= On —Off Switching Duty rated breaker,as per NEC 240 -53(d) LV= Via low voltage transformer HACR= Breaker suitable for the protection of heating, A/C and refrigeration equipment Ckt N•. 1 3 USE RANGE SPEC VOLT 240 FKR AMP 50 WIRE 6 COND SIZE 314 VA 12,000 PHASE Ckt N•. USE C.U. SPEC VOLT 24a BKR AMP 30 WIRqilo�ZEI) 10 3/4 VA 5,000 A C 2 ti 4 5 7 DRYER 240 30 1 10 112 1 6,800 6 REFRIGERATOR U. 120 20 12 112 soo a BATH 1, WIC LIGHTS do REC 120 15 14 112 W y WN 1 240 70 4 3/4 1t,800 10 MBR LIGHT do REC. � 120 15 14 112 • ** W CD BR 2, HALL, UTIL, LT.JeREC. � 120 15 1 14 112 *( * *) 11 to 12 13 WASHER 120 20 12 112 750 14 BR 3, BATH 2 LT. do REC. p 120 15 14 1/2 *( * *) 16 BATH 2 GFI 120 20 12 112 1 15 BATH 1 GFI 120 20 12 112 * Q O 1 d KITCHEN, FOYER LT. do REC 120 15 14 112 *( * *) 17 GARBAGE DISPOSAL Z 120 20 12 112 soo Uj (n w. W DINING, GR. LIGHT do REC 120 20 12 112 *( * *) 19 DISHWASHER 120 20 12 112 500 20 21 SMALL ,APPLIANCE 120 20 12 112 15QO 22 SPARE 23 SMALL APPLIANCE 120 20 12 112 1500 24 EXTERIOR LIGHTS do REC 120 20 12 112 26 SPARE 25 MICROWAVE 120 20 12 112 1000 27 29 A. H. U. 240 40 s 3/4 5,040 2a WH 2 SPARE 220 25 10 112 4,200 30 32 31 SPARE ( *) AS PER SQ -FT OF CONDITION SPACE ** ARC FAULT CIRCUIT INTERRUPTER PROTECTION 1. PROVIDE EXPANSION JOINTS FITTINGS TO CONDUITS CROSSING STRUCTURAL EXPANSION JOINTS. 2. PROVIDE PULL WIRES IN TELEPHONE AND ALL EMPTY CONDUIT SYSTEMS. 3. ALL CONDUCTORS SHALL BE COPPER. 4. ALL CONTROL W IRFS AND CONNECTIONS REQUIRED FOR AIR CONDITIONING AND VENTILATING EQUIPMENT OPERATION SHALL BE PROVIDED. REFER TO MECHANICAL DRAWING. 5. LOCATION OF OUTLETS IN ELECTRICIAN DRAWINGS IS DIAGRAMMATIC. CHECK ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF OUTLETS. ADJUST OUTLET LOCATIONS TO AVOID INTERFERENCE WITH OTHER TRADES. 6. LOCATION OF SWITCHES VARIES WITH THE DOOR SWING: FOLLOW ARCHITECTURAL DRAWINGS IN EACH CASE. 7. CLAIMS FOR EXTRA WORK REQ'D TO MEETCODE REQUIREMENTS WILL NOT BE CONSIDERED. 8, AMONG ELECTRICAL CONTRACTOR'S RESPONSIBILITIES THERE SHALL BE: 8.1 — TO VERIFY ACTUAL FIELD CONDITIONS PRIOR BIDDING. ONCE THE AMOUNT OF WORK INVOLVED HAS BEEN DETERMINED, THE CONTRACTOR SHALL INCLUDE IN HIS BID ALL NECESSARY PARTS AND LABOR REQUIRED TO COMPLETE A SAFE AND CORRECT ELECTRICAL INSTALLATION. 8.2 — TO PROVIDE ADEQUATE WIRING, BREAKER OR SWITCH PROTECTION TO CONFORM WITH FURNISHED EQUIPMENT WITHOUT EXTRA COST TO THE OWNER. 8.3 — TO CONTACT F.P.L. COMPANY'S REPRESENTATIVE TO DETERMINE FINAL UNDERGROUND PRIMARY CONDUITS ROUTING AND TO INSTALL THEM AS PER F.P.L. COMPANY'S STANDARDS, 8.4 TO CONTACT TELEPHONE COMPANY'S REPRESENTATIVE TO DETERMINE FINAL ROUTING UNDERGROUND CONDUITS FOR TELEPHONE SUPPLY AND TO INSTALL THEM AS PER THE COMPANY'S STANDARDS. 8.5 TO VERIFY EXISTING UTILITIES FACILITIES PRIOR TRENCHING. 8.6 TO COORDINATE, PRIOR TO CONSTRUCTION, WITH MECHANICAL AND PLUMBING SUBCONTRACTORS REGARDING SPACE REQUIRED FOR FULL INSTALLATION. AND POSSIBLE CONFLICTS. 9. ALL 15 AND 20 AMP OUTLETS IN FAMILY ROOM, DINING ROOM, LIVING ROOM, BEDROOMS, CLOSETS, HALLWAY TO BE PROTECTED BY A LISTED ARC FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE. 10. ALL OUTLETS TO BE TAMPLER PROOF TYPE A24 �— - Ms VP VP- G A 2 4 P Uj Q 14 Al2 zY ON G 1 4 GGCi 13: ti w 13Cbp00M 2 to I i= Al2 Al2 ........ i S A24" _. 110M A\ A24o VP LEC.mMT .1 M TO FPL U.P. ELECTRICAL SCALE: 1/4"=—V-0" TO FPL 3 #210 THWN (Cu) IN 2" COND. RUNNING FROM F.P.L. SERVICE POINT. WEATHER HEAD ELEC. METER 200A MCB 1 # 4 THWN (Cu) IN 314" COND. GRADE LEVEL NEW 10' -0" DEEP GROUND>f GI ROD - 112" DIAMETER �— EXTERIOR INTERIOR ELECT. PANEL A Gt,•@ Gw• u i br••s iWG•• r v • no G ••• v o • •uu ♦ u u • Yr • 4'� ,1 u F �' �' _ ••C C6• 5 • Y • G !� r G • Y • • V F G G i r • Y • •v• r,r•• u•rrrr r G u u �i1t r k 4+ U • � Yrr�i • •YruG u PITCH POCKET/CAP 314" EMT TO ROOF FOR FUTURE SOLAR TERMINATE +4FT AFF —_*"_314" EMT TO UTIL. RM FOR FUTURE SOLAR 3 #2/0 THWN (Cu) 1 6 THWN (C) G HOSE BIBB u IN 2" COND. C`WP'0 NEW #4 IN 1/2" CONDUIT TO (2) 5/8" X 10 FT GROUND RODS @ MIN. 6 FT APART ELECTRICAL RISER DIAGRAM N. T. S. VP LS A24 - ..... -..- I .............. .8 A8/ I (1 0- A8 .j rF VP A24 �5 A24F 1 MS / LS vPi�A24 r 4 r i z OV P Uj Q 14 • zY ON G 1 4 GGCi 13: ti w to 0 M U. Z W Z W W CO) •• W © 0 II Z � z Q W W CD LL > � J O .e[ Cl) M =3 to _ Too' M 0 O 1 Ca p � 0 U. LL 0 1 Q O W ct� 20 1 Z •; U D Uj (n w. W O Z C) Q �' !1fTY � •L) A =M,�. �..N , «.awt MM t a>� lawc � I MMli1�iG 111E ' lME MAY MSR E NtILICA11 11�T Nt .M7 � vNnm1T .p„MI MI 1 OF Im JOB No.: 12.06501 . S FR REVISIONS: DATE: 3/5/2012 CHECKED BY: DRAWN BY: SRL PLOT : 100% SHEET INDEX: ELECTRICAL PLAN NOTES SHEET No.: I E -1 it 12 Q LO w to 0 M Z •• W © C] I � z W CD � z LAj I C) .e[ Cl) p C7) JE =3 to �' !1fTY � •L) A =M,�. �..N , «.awt MM t a>� lawc � I MMli1�iG 111E ' lME MAY MSR E NtILICA11 11�T Nt .M7 � vNnm1T .p„MI MI 1 OF Im JOB No.: 12.06501 . S FR REVISIONS: DATE: 3/5/2012 CHECKED BY: DRAWN BY: SRL PLOT : 100% SHEET INDEX: ELECTRICAL PLAN NOTES SHEET No.: I E -1 it 12