14-952R-003GENERAL NOTES: THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES IN LOCATING DEVICES, WIRING, CONDUIT, AND EQUIPMENT TO AVOID ANY INTERFERENCE. CONTRACTOR TO INSTALL ALL WORK IN STRICT COMPLIANCE WITH LOCAL CODES AND ORDINANCES. KEYED NOTES: 1 SEE ONE -LINE DIAGRAM FOR ADDITIONAL INFORMATION. 2 APPROXIMATE LOCATION OF EXISTING (2) 3' CONDUIT STUBS INTO SPACE. ELECTRICAL CONTRACTOR SHALL EXTEND TO ELECTRICAL PANEL 'M' AND PROVIDE NEW ELECTRICAL CONDUCTORS FROM EXISTING DISTRIBUTION PANEL 'DP -1' TO PANEL V. FIELD VERIFY EXACT LOCATION AND REQUIREMENTS. SEE ONE -LINE DIAGRAM FOR ADDITIONAL INFORMATION. OPROVIDE ROUGH -IN AND FINAL CONNECTION TO ROOFTOP UNIT. ROOFTOP UNIT - MOUNTED DISCONNECTING MEANS SUPPLIED BY EQUIPMENT MANUFACTURER. ELECTRICAL CONTRACTOR TO PROVIDE AND MAKE FINAL CONNECTION TO UNIT - MOUNTED WEATHERPROOF GFI SERVICE RECEPTACLE. COORDINATE WITH MECHANICAL CONTRACTOR AND EQUIPMENT MANUFACTURER. COORDINATE ALL WORK WITH MECHANICAL CONTRACTOR IN FIELD. OPROVIDE (2) DUPLEX RECEPTACLES AND DATA/PHONE OUTLET FLUSH IN FLOOR. CONTRACTOR TO SAW CUT FLOOR AND ROUTE CONDUIT TO NEAREST WALL THAT EXTENDS TO CEILING FOR ROUTING OF HOME RUNS. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH OWNER PRIOR TO COMMENCING WORK. COORDINATE SAW CUTTING OF FLOOR WITH LANDLORD PRIOR TO COMMENCING WORK. OTELEPHONE BOARD. FIELD VERIFY EXACT LOCATION OF BUILDING TELEPHONE SERVICE LOCATION AND PROVIDE 2' CONDUIT W/ PULLSTRING FROM TELEPHONE SERVICE LOCATION TO TELEPHONE BOARD. PROVIDE 3/4' PLYWOOD BACKBOARD FOR MOUNTING OF NEW TELEPHONE EQUIPMENT. SIZE AND SECURE AS REQUIRED. PROVIDE (2) OPROVIDE ROUGH -IN AND FINAL CONNECTION TO SMOKE DETECTOR MOUNTED IN RETURN AIR DUCT. DETECTOR SHOULD SHUT DOWN RTU UPON ACTIVATION. v SHOW WINDOW RECEPTACLE MOUNTED FLUSH IN CEILING. FIELD VERIFY DEVICE AND COVERPLATE FINISH WITH ARCHITECT AND OWNER PRIOR TO COMMENCING WORK. OPROVIDE (2) QUAD RECEPTACLES FLUSH IN FLOOR. CONTRACTOR TO SAW CUT FLOOR AND ROUTE CONDUIT TO NEAREST WALL THAT EXTENDS TO CEILING FOR ROUTING OF HOME RUNS. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH OWNER PRIOR TO COMMENCING WORK. COORDINATE SAW CUTTING OF FLOOR WITH LANDLORD PRIOR TO COMMENCING WORK. AREA OF WORKS €€ ....... ............................... PANEL 'DP-1 ELECTRICAL ROOM n ELECTRICAL POWER PLAN SCALE: 3/16" = 1' -0" n KEY PLAN SCALE: 1" = 50' -0" design, inc. p.o. box 14.2116 coral gables, florida 33114.2116 v. 305.443.3100 f. 305.259.3986 e. info @whadesign.com architect of record: William Arthur License Number: 0012074 U1 � � o . �� . • ' .; t3► ems, :.g : •. i w t;: �Q o •a - co �+�= 44 0 design associate: bFORD These plans and specifications are the exclusive property of WHA Design. Any reproduction, modification, disclosure, and/or use of these materials (or any portion thereof) without WHA Design's prior written consent is strictly prohibited. V L W n project history: 1Q Mechanical 10 -07 -14 �2 Fire Alarm /Plumbing 3 -25 -15 A project information: date: 07/08/13 project number: 13 -20 sheet title: ELECTRICAL POWER PLAN sheet number: E200 file: 884 -13 e2.0.dwg Et13 Z: CM iF_J LL .X .E 4-a C/)� o 6-J CO� s € C.0 U) _- N � 3 CL o project history: 1Q Mechanical 10 -07 -14 �2 Fire Alarm /Plumbing 3 -25 -15 A project information: date: 07/08/13 project number: 13 -20 sheet title: ELECTRICAL POWER PLAN sheet number: E200 file: 884 -13 e2.0.dwg