14-952R-002PLUMBING SPECIFICATIONS:
1.1 ALL PLUMBING WORK INCLUDING INSTALLATION, EQUIPMENT, FIXTURES AND PIPING
SHALL BE INSTALLED IN STRICT COMPLIANCE WITH LOCAL CODE AND ADOPTED
ORDINANCES, AND REGULATIONS SET FORTH BY THE AHJ (AUTHORITY HAVING
JURISDICTION).
1.2 ROUTING OF ALL SANITARY PLUMBING, DOMESTIC WATER PIPING AND GAS PIPING AS
SHOWN ON THE PLANS IS SHOWN WITH THE INTENTION OF INDICATING THE APPROX-
IMATE LOCATION OF EXISTING CONDITIONS, AND NEW ITEMS. PLUMBING CONTRACTORS
SHALL VISIT THE JOB SITE CONDITIONS PRIOR TO SUBMITTING BIDS OR STARTING WORK.
THIS CONTRACTOR SHALL COORDINATE THE INSTALLATION OF HIS WORK WITH THE
WORK OF ALL OTHER TRADES TO AVOID INTERFERENCE CONTRACTORS MAY DEVIATE
FROM THE LOCATION OF PIPING SHOWN IF INSTALLATION COMPLIES WITH LOCAL CODES
AND INDUSTRY PRACTICES, AND IF THE AHJ AND OWNER'S REPRESENTATIVE APPROVE.
ITEMS NOT SHOWN ON THE PLANS OR SHOWN IN CONFLICT WITH ANY CODE, REGULA-
TION OR EXISTING CONDITION SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER
IMMEDIATELY. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLING ALL WORK IN
ACCORDANCE WITH LOCAL CODES.
1.3 PRIOR TO SUBMISSION OF THE CONTRACTORS COST ESTIMATE FOR WORK INCLUDED
UNDER THIS PROJECT, THE CONTRACTOR SHALL VISIT THE JOB SITE TO EXAMINE ALL
EXISTING CONDITIONS RELATED TO HIS WORK, AND UPON FINAL EXAMINATION OF SUCH
SHALL SUBMIT A FINAL PROPOSAL AS EVIDENCE THAT THIS CONTRACTOR HAS VISITED
SAID SITE AND VERIFIED ALL EXISTING AND PROJECT CONDITIONS. CLAIMS OF ADD-
ITIONAL WORK OR ADD -ONS DUE TO NON - VERIFICATION OF EXISTING CONDITIONS WILL
NOT BE CONSIDERED BY THE OWNER. ALL ADDITIONAL WORK WHICH IS NOT CLEARLY
APPROVED PRIOR TO PERFORMANCE OF SUCH WORK WILL BE CHARGED TO THE
CONTRACTOR, AND IF NOT SETTLED WILL BE HELD FROM HIS FINAL PAYMENT.
2 MATERIALS
21 DOMESTIC WATER PIPING:
WATER PIPING SHALL BE TYPE -L COPPER WITH WROUGHT FITTINGS. LEAD -FREE SOLDER
OR SILVER SOLDER SHALL BE USED AT ALL POINTS OF CONNECTION. HANGERS SHALL
BE EQUAL TO CLEVIS TYPE HANGERS AND SHALL BE USED ON ALL PIPING AT
INTERVALS AS REQUIRED BY CODE THE CONTRACTOR SHALL ALLOW ADDITIONAL
CLEARANCE FOR EXPANSION AND CONTRACTION FOR INSULATED AND NON- INSULATED
PIPING. AT THE CONTRACTOR'S OPTION CROSS LINKED POLYETHYLENE (PEX) PIPING
MAY BE UTILIZED WHERE ALLOWED BY AUTHORITY HAVING JURISDICTION.
ALL COMPONENTS OF THE POTABLE WATER SYSTEM SHALL COMPLY WITH THE LEAD
FREE REQUIREMENTS AS NOTED IN SECTION 1417 OF THE SAFE DRINKING WATER ACT.
22 DRAIN, WASTE, AND VENT PIPING:
DRAIN, WASTE, AND VENT PIPING SHALL BE SCHEDULE 40 PVC OR SERVICE WEIGHT
CAST IRON, AS REQUIRED BY CODE PVC SHALL NOT BE USED IN RETURN AIR
PLENUMS WHERE PROHIBITED BY CODE WHERE FLOOR OR HUB DRAINS ARE SHOWN
AS CAST IRON, THE CONTRACTOR SHALL PROVIDED A SUITABLE COUPLING WHICH IS
APPROVED BY CODE
ALL CAST IRON SOIL PIPE/FITTINGS BELOW OR ABOVE GROUND SHALL BEAR
THE COLLECTIVE TRADEMARK OF CISPI AND /OR BE 'NSF INTERNATIONAL'.
ALL STANDARD COUPLINGS SHALL BE IN COMPLIANCE TO CISPI 310 (LATEST
EDITION), BEARING THE MARK OF NSF CISPI 310 (LATEST EDITION), BEARING
THE MARK OF NSF INTERNATIONAL
0
AT THE CONTRACTOR'S OPTION AND WHERE ALLOWED BY CODE AND THE LOCAL
AUTHORITY HAVING JURISDICTION SCHEDULE 40 PVC -DWV MAY BE USED.
CONDENSATE DRAIN LINES FOR COOLERS AND FREEZER SHALL BE COPPER.
3. VALVES: r • •
SHUT OFF VALVES SHALL BE EITHER GATE -TYPE OR BALL VALVES BY CRANE, STOCKHAM
OR 'POWELL' MIXING VALVES SHALL BE BY 'LAWLER* OR APPROVED EQUAL BACKWATER
VALVES SHALL BE BY "ZURN' OR APPROVED EQUAL ALL VALVES SHALL MEET THE LEAD
FREE REQUIREMENTS AS NOTED IN SECTION 1417 OF THE SAFE DRINKING WATER ACT.
4. PLUMBING SPECIALTIES:
4.1 AIR CHAMBERS: SHALL BE CONSTRUCTED OF (LEAD FREE) TYPE -L COPPER, AIR
CHAMBERS SHALL BE ONE SIZE LARGER THAN THE SUPPLY PIPING, AND SHALL BE 18
INCHES LONG, PROPERLY CAPPED AND SUPPORTED. FACTORY MANUFACTURED ITEMS
CAN BE SUBSTITUTED AT THE CONTRACTORS OPTION BY "NIBCO', 'WADE' OR EQUAL
4.2 CLEAN OUTS: WALL CLEAN OUTS SHALL HAVE STAINLESS STEEL COVERS AS MANU-
FACTURED BY 'WADE" OR APPROVED EQUAL FLOOR CLEAN OUTS SHALL HAVE SATIN
FINISH NICKEL TOP, IN FINISHED AREAS, AND SATIN BRONZE CAP IN AREAS WHICH ARE
NOT FINISHED. CLEAN OUTS SHALL BE MANUFACTURED BY 'WADE" OR APPROVED
EQUAL
4.3 FIXTURES: PLUMBING FIXTURES SHALL BE AS SPECIFIED ON THESE PLANS OR ON THE
ARCHITECTURAL PLANS. ALL FIXTURES SHOULD MEET ADA REQUIREMENTS WHERE
APPLICABLE FIXTURES SHOULD BE OF THE HIGHEST QUALITY BY 'AMERICAN
STANDARD', KOHLER' OR APPROVED EQUAL AND SHALL MEET THE LEAD FREE
REQUIREMENTS AS NOTED IN SECTION 1417 OF THE SAFE DRINKING WATER ACT.
4.4 WATER HEATERS: IF NEW WATER HEATER(S) ARE TO BE INSTALLED THEY SHALL BE
AS SPECIFIED ON THE PLANS, AND SHALL BE OF COMMERCIAL GRADE, AND AGA
APPROVED IF GAS FIRED AND UL APPROVED IF ELECTRIC. HEATERS SHALL HAVE A 150
PSI WORKING PRESSURE RATING. WATER HEATERS AND ALL COMPONENTS SHALL MEET
THE LEAD FREE REQUIREMENTS AS NOTED IN SECTION 1417 OF THE SAFE DRINKING
WATER ACT. WATER HEATER INSTALLATION MANUALS SHALL BE GIVEN TO THE OWNER.
SEE PLUMBING FIXTURE SCHEDULE
5. EXECUTION:
5.1 ALL PLUMBING FIXTURES, EQUIPMENT AND PIPING SHALL BE INSTALLED PER LOCAL
CODE AND ESTABLISHED INDUSTRY PRACTICES. LOCATE ALL PIPING, AS SHOWN ON THE
PLANS.
5.2 COORDINATE WITH ALL OTHER TRADES TO AVOID INTERFERENCE, AND ADHERE TO ALL
SPECIFICATIONS AND MANUFACTURER GUIDELINES.
5.3 RUN ALL DOMESTIC WATER PIPING AS HIGH AS POSSIBLE INSTALL HANGERS AND
STRAPPING, ALLOWING FOR EXPANSION AND CONTRACTION OF PIPING. DO NOT HANG
OR SUPPORT OTHER EQUIPMENT OR PIPING FROM WATER LINES. SEPARATE HOT AND
COLD WATER LINES A MINIMUM OF SIX (6) INCHES. INSULATE ALL PIPING WITH
1' INSULATION WHICH MEETS OR EXCEEDS 25/50 RATINGS.
5.4 INSTALL SOIL, WASTE AND VENT PIPING WITH A MINIMUM SLOPE OF 1/4' PER FOOT IN
THE DIRECTION OF FLOW FOR DRAINS AND AGAINST THE FLOW OF VENT GASSES. NO
FIXTURE SHALL HAVE AN S -TRAP OR BE DOUBLE TRAPPED.
5.5 INSULATE ALL DOMESTIC WATER PIPING, HORIZONTAL WASTE PIPING AND STORM
DRAINAGE PIPING ABOVE CEILINGS.
6, VALVES:
LOCATE VALVES SO AS TO BE ACCESSIBLE AND SO THAT SEPARATE SUPPORT CAN BE
PROVIDED WHEN NECESSARY. INSTALL ALL STEMS UPRIGHT. DO NOT INSTALL VALVES OF
DISSIMILAR COMPOSITION WITHOUT AN APPROVED DIELECTRIC FITTING.
7. TEST AND STERILIZATION:
FLUSH, TEST AND STERILIZE ALL PLUMBING PIPING INCLUDING DRAINS, WASTE VENTS AND
WATER PIPING PER LOCAL CODES AND REGULATIONS.
LINE TYPES:
SANITARY PIPING
VENT PIPING
COLD WATER PIPING
- - - - - - - - 110 DEG HOT WATER PIPING
- - - - - - - - - - - UNDER SLAB WATER PIPING
EXISTING PIPING SHOWN IN A LIGHTER SHADE
GENERAL NOTES
1. PLUMBING CONTRACTOR SHALL VERIFY WITH THE LOCAL HEALTH
DEPARTMENT AND /OR WATER COMPANY AS TO THE METER AND VALVING
ARRANGEMENTS OF THE DOMESTIC WATER SERVICE WHICH ENTERS THE
BUILDING. IF A BACKFLOW PREVENTER AND /OR PRESSURE REDUCING VALVE
IS REQUIRED, THE PLUMBER SHALL FURNISH AND INSTALL SAME PER LOCAL
AND STATE REQUIREMENTS.
2 PLUMBING CONTRACTOR SHALL PROVIDE AND INSTALL STOP VALVES AT
FINISHED WALL SURFACE
3. ALL PLUMBING PIPING SHALL BE ROUTED UNDER THE FLOOR, ABOVE THE
CEILING, OR LOCATED WITHIN WALLS OR PLUMBING CHASES. EXPOSE PIPING
ONLY WHERE NECESSARY TO CONNECT TO EQUIPMENT.
4. SEE ARCHITECTURAL PLANS FOR FINAL EQUIPMENT LOCATIONS. COORDINATE
WITH EQUIPMENT SUPPLIER AND THE GENERAL CONTRACTOR FOR FINAL WALL
LOCATIONS.
5. PROVIDE WATER CONNEC11ONS AS REQUIRED, ANGLE STOP AND ESCUTCHEON
PLATE FOR ALL FINAL WATER CONNECTIONS.
6. FURNISH BURST PROOF BRAIDED FLEXIBLE CONNECTORS FOR FINAL
CONNECTIONS TO SINKS AND OTHER EQUIPMENT.
7. FURNISH TUBING AND FITTINGS, AS REQUIRED, FOR ALL FINAL CONNECTIONS.
8. PROVIDE AIR CHAMBER TYPE WATER HAMMER ARRESTORS OR ACCEPTABLE
FACTORY MANUFACTURED SUBSTITUTES AT ALL WATER ROUGH -IN
LOCATIONS.
9. ALL COMPONENTS OF THE POTABLE WATER SYSTEM SHALL COMPLY WITH THE
LEAD FREE REQUIREMENTS AS NOTED IN SECTION 1417 OF THE SAFE
DRINKING WATER ACT.
10. ALL PLUMBING WORK SHALL BE PERFORMED IN FULL COMPLIANCE WITH THE
LOCAL PLUMBING CODE, HEALTH REGULATIONS, AND LOCAL ORDINANCES.
11. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR ALL PERMIT FEES,
UTILITY TAP FEES, AND INSPECTION FEES AS REWIRED.
12. THE CONTRACTOR SHALL COORDINATE THE LOCATION OF HIS FLOOR DRAINS,
HUB DRAINS AND CONNECTION POINTS WITH THE GENERAL CONTRACTOR. THE
PLUMBING CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS PRIOR TO
SUBMITTING HIS BID.
DOMESTIC WATER CALC.
DESCRIPTION
QUANTITY
FU EACH
TOTAL FU
MOP SINK
1
3
3
DRINKING FOUNTAIN
1
.25
.25
WATER CLOSET
2
5
10
LAVATORY
2
2
4
TOTAL
17.25
17.25 FIXTURE UNITS = 18.8 GPM = 1" DOMESTIC
WATER SERVICE PER THE 2010 FLORIDA PLUMBING
CODE
CROSS CONNECTION CONTROL SCHEDULE
FIXTURE
MAKE
MODEL
ASSE, ASME OR
MODEL
ACCESSORIES
NOTES
ANSI STANDARD
MOP SINK FAUCET CONTAINS
WATTS do
9DM2 -S
ASSE 1012
INTERGRAL BACKFLOW DEVICE
INTEGRAL
-
ASSE 1001
LAVATORIES
AIR GAP
-
ASME A1121.2
WATER HEATER
WATTS
LFN360
ANSI Z21.22
BUILIDNG WATER SUPPLY
WATTS
LF009 M2 -QT
ASK 1013
-
c
o
OR EQUAL
SECURED TOP
PROVIDE APPROPRIATE BACK FLOW PREVENTER AT OTHER EQUIPMENT AS
REQUIRED BY CODE
PLUMBING
FIXTURE
SCHEDULE
PLAN MARK
MANUFACTURER
MODEL
ACCESSORIES
NOTES
® FLOOR DRAINS
WADE OR EQUAL
1103STD6
P -TRAP
7 \ MS
(TYPICAL)
W /6"
TRAP PRIMER
design associate:
O
bFORD
STRAINER
=LL
+O FLOOR CLEANOUT
WADE OR EQUAL
6000
NICKEL BRONZE
4-a
c
o
�-J 0o g
SECURED TOP
WH
A.O. SMITH
DSE -10
U
Q
10 GAL 3 KW
(WATER HEATER)
I
I
I
1 24 GPH REC. 0 50' RISE
SEE ARCHITECTURAL SHEET A8.0 FOR ADDITIONAL FIXTURE SPECIFICATIONS
4"
3"
SANITARY ISOMETRIC DIAGRAM
SCALE: NTS
3/4"
1/2 1
3/4„
WC
MS
(' WC LAV
i I
LAV I
OWFI
i
1/2 DF
DOMESTIC WATER ISOMETRIC DIAGRAM
SCALE: NTS
KEYED NOTES:
O1 MAKE CONNECTION TO NEW SANITARY LINE (MIN. 4') TO SERVE PREMISES.
FIELD VERIFY EXACT LOCATION AND INVERT ELEVATION OF POINT OF
CONNEC11ON AND ALL REQUIREMENTS PRIOR TO COMMENCING WORK. SEE
CIVIL PLANS FOR CONTINUATION.
OEXTEND VENTS THROUGH ROOF SUCH THAT MINIMUM 10' CLEARANCE TO AIR
INTAKES IS MAINTAINED.
O3 MAKE 1' CONNECTION TO EXISTING WATER SERVICE IN AT EXISTING TOILET
ROOMS WITHIN THE BUILDING ( +/- 300' AWAY). ENTIRE INSTALLATION SHALL
BE IN ACCORDANCE WITH LOCAL CODES. CONTRACTOR SHALL FIELD VERIFY
REQUIREMENTS PRIOR TO BID. BID SHALL INCLUDE ALL WORK NECESSARY
FOR A FULLY OPERATIONAL SYSTEM.
O4 PROVIDE AND INSTALL TANK TYPE WATER HEATER AS SCHEDULED ON THIS
SHEET. WATER HEATER TO BE MOUNTED ON PLATFORM ABOVE TOILET
ROOMS. INSTALL WATER HEATER PER DETAIL ON THIS SHEET.
/-VTRO
LAV
WC
f FCO I
aesign, inc,
p.o. box 14.2116
coral gables, florida
33114.2116
v. 305.443.3100
f. 305.259.3986
e. info @whadesign.com
architect of record:
William Arthur
License Number: 0012074
J- ..i _ . L -L _! _ _a _i._ _ L. _i._
III II
n
SANITARY PLAN
SCALE: 3/16" = V -0"
■ 1
■
■
■ �� O
■
■
■ °-1 �P
{ 1_ :� ° %I
IIIIIIIIi(1ilf
Illlllilllili
n
)DOMESTIC WATER PLAN
SCALE: 3/16" = V -0"
n
KEY PLAN
SCALE: NTS
These plans and specifications are
the exclusive property of MA
Design. Any reproduction,
modification, disclosure, and/or use
of these materials (or any portion
thereof) without WHA Design's prior
written consent is strictly prohibited.
t/t1
��•'• 1 •W�
} r
..� V 4 �W
W
qu.
� • •�CIOO
7 \ MS
PiP
s,� � �'.
sa
design associate:
O
bFORD
J- ..i _ . L -L _! _ _a _i._ _ L. _i._
III II
n
SANITARY PLAN
SCALE: 3/16" = V -0"
■ 1
■
■
■ �� O
■
■
■ °-1 �P
{ 1_ :� ° %I
IIIIIIIIi(1ilf
Illlllilllili
n
)DOMESTIC WATER PLAN
SCALE: 3/16" = V -0"
n
KEY PLAN
SCALE: NTS
These plans and specifications are
the exclusive property of MA
Design. Any reproduction,
modification, disclosure, and/or use
of these materials (or any portion
thereof) without WHA Design's prior
written consent is strictly prohibited.
project history:
Mechanical 10 -07 -14
A2 Fire Alarm /Plumbing 3 -25 -15
project information:
date:
07/08/13
project number:
13 -20
sheet title:
PLUMBING
PLAN
sheet number:
■
Pi
884 -13 pl.0.dwg
U)
L
W
E
L
=LL
v♦
MIX .E
(VI C) M
4-a
c
o
�-J 0o g
Co
�}- m
O E
,c
.S
U
Q
c
3
CL
o
project history:
Mechanical 10 -07 -14
A2 Fire Alarm /Plumbing 3 -25 -15
project information:
date:
07/08/13
project number:
13 -20
sheet title:
PLUMBING
PLAN
sheet number:
■
Pi
884 -13 pl.0.dwg