14-952R-002PLUMBING SPECIFICATIONS: 1.1 ALL PLUMBING WORK INCLUDING INSTALLATION, EQUIPMENT, FIXTURES AND PIPING SHALL BE INSTALLED IN STRICT COMPLIANCE WITH LOCAL CODE AND ADOPTED ORDINANCES, AND REGULATIONS SET FORTH BY THE AHJ (AUTHORITY HAVING JURISDICTION). 1.2 ROUTING OF ALL SANITARY PLUMBING, DOMESTIC WATER PIPING AND GAS PIPING AS SHOWN ON THE PLANS IS SHOWN WITH THE INTENTION OF INDICATING THE APPROX- IMATE LOCATION OF EXISTING CONDITIONS, AND NEW ITEMS. PLUMBING CONTRACTORS SHALL VISIT THE JOB SITE CONDITIONS PRIOR TO SUBMITTING BIDS OR STARTING WORK. THIS CONTRACTOR SHALL COORDINATE THE INSTALLATION OF HIS WORK WITH THE WORK OF ALL OTHER TRADES TO AVOID INTERFERENCE CONTRACTORS MAY DEVIATE FROM THE LOCATION OF PIPING SHOWN IF INSTALLATION COMPLIES WITH LOCAL CODES AND INDUSTRY PRACTICES, AND IF THE AHJ AND OWNER'S REPRESENTATIVE APPROVE. ITEMS NOT SHOWN ON THE PLANS OR SHOWN IN CONFLICT WITH ANY CODE, REGULA- TION OR EXISTING CONDITION SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IMMEDIATELY. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLING ALL WORK IN ACCORDANCE WITH LOCAL CODES. 1.3 PRIOR TO SUBMISSION OF THE CONTRACTORS COST ESTIMATE FOR WORK INCLUDED UNDER THIS PROJECT, THE CONTRACTOR SHALL VISIT THE JOB SITE TO EXAMINE ALL EXISTING CONDITIONS RELATED TO HIS WORK, AND UPON FINAL EXAMINATION OF SUCH SHALL SUBMIT A FINAL PROPOSAL AS EVIDENCE THAT THIS CONTRACTOR HAS VISITED SAID SITE AND VERIFIED ALL EXISTING AND PROJECT CONDITIONS. CLAIMS OF ADD- ITIONAL WORK OR ADD -ONS DUE TO NON - VERIFICATION OF EXISTING CONDITIONS WILL NOT BE CONSIDERED BY THE OWNER. ALL ADDITIONAL WORK WHICH IS NOT CLEARLY APPROVED PRIOR TO PERFORMANCE OF SUCH WORK WILL BE CHARGED TO THE CONTRACTOR, AND IF NOT SETTLED WILL BE HELD FROM HIS FINAL PAYMENT. 2 MATERIALS 21 DOMESTIC WATER PIPING: WATER PIPING SHALL BE TYPE -L COPPER WITH WROUGHT FITTINGS. LEAD -FREE SOLDER OR SILVER SOLDER SHALL BE USED AT ALL POINTS OF CONNECTION. HANGERS SHALL BE EQUAL TO CLEVIS TYPE HANGERS AND SHALL BE USED ON ALL PIPING AT INTERVALS AS REQUIRED BY CODE THE CONTRACTOR SHALL ALLOW ADDITIONAL CLEARANCE FOR EXPANSION AND CONTRACTION FOR INSULATED AND NON- INSULATED PIPING. AT THE CONTRACTOR'S OPTION CROSS LINKED POLYETHYLENE (PEX) PIPING MAY BE UTILIZED WHERE ALLOWED BY AUTHORITY HAVING JURISDICTION. ALL COMPONENTS OF THE POTABLE WATER SYSTEM SHALL COMPLY WITH THE LEAD FREE REQUIREMENTS AS NOTED IN SECTION 1417 OF THE SAFE DRINKING WATER ACT. 22 DRAIN, WASTE, AND VENT PIPING: DRAIN, WASTE, AND VENT PIPING SHALL BE SCHEDULE 40 PVC OR SERVICE WEIGHT CAST IRON, AS REQUIRED BY CODE PVC SHALL NOT BE USED IN RETURN AIR PLENUMS WHERE PROHIBITED BY CODE WHERE FLOOR OR HUB DRAINS ARE SHOWN AS CAST IRON, THE CONTRACTOR SHALL PROVIDED A SUITABLE COUPLING WHICH IS APPROVED BY CODE ALL CAST IRON SOIL PIPE/FITTINGS BELOW OR ABOVE GROUND SHALL BEAR THE COLLECTIVE TRADEMARK OF CISPI AND /OR BE 'NSF INTERNATIONAL'. ALL STANDARD COUPLINGS SHALL BE IN COMPLIANCE TO CISPI 310 (LATEST EDITION), BEARING THE MARK OF NSF CISPI 310 (LATEST EDITION), BEARING THE MARK OF NSF INTERNATIONAL 0 AT THE CONTRACTOR'S OPTION AND WHERE ALLOWED BY CODE AND THE LOCAL AUTHORITY HAVING JURISDICTION SCHEDULE 40 PVC -DWV MAY BE USED. CONDENSATE DRAIN LINES FOR COOLERS AND FREEZER SHALL BE COPPER. 3. VALVES: r • • SHUT OFF VALVES SHALL BE EITHER GATE -TYPE OR BALL VALVES BY CRANE, STOCKHAM OR 'POWELL' MIXING VALVES SHALL BE BY 'LAWLER* OR APPROVED EQUAL BACKWATER VALVES SHALL BE BY "ZURN' OR APPROVED EQUAL ALL VALVES SHALL MEET THE LEAD FREE REQUIREMENTS AS NOTED IN SECTION 1417 OF THE SAFE DRINKING WATER ACT. 4. PLUMBING SPECIALTIES: 4.1 AIR CHAMBERS: SHALL BE CONSTRUCTED OF (LEAD FREE) TYPE -L COPPER, AIR CHAMBERS SHALL BE ONE SIZE LARGER THAN THE SUPPLY PIPING, AND SHALL BE 18 INCHES LONG, PROPERLY CAPPED AND SUPPORTED. FACTORY MANUFACTURED ITEMS CAN BE SUBSTITUTED AT THE CONTRACTORS OPTION BY "NIBCO', 'WADE' OR EQUAL 4.2 CLEAN OUTS: WALL CLEAN OUTS SHALL HAVE STAINLESS STEEL COVERS AS MANU- FACTURED BY 'WADE" OR APPROVED EQUAL FLOOR CLEAN OUTS SHALL HAVE SATIN FINISH NICKEL TOP, IN FINISHED AREAS, AND SATIN BRONZE CAP IN AREAS WHICH ARE NOT FINISHED. CLEAN OUTS SHALL BE MANUFACTURED BY 'WADE" OR APPROVED EQUAL 4.3 FIXTURES: PLUMBING FIXTURES SHALL BE AS SPECIFIED ON THESE PLANS OR ON THE ARCHITECTURAL PLANS. ALL FIXTURES SHOULD MEET ADA REQUIREMENTS WHERE APPLICABLE FIXTURES SHOULD BE OF THE HIGHEST QUALITY BY 'AMERICAN STANDARD', KOHLER' OR APPROVED EQUAL AND SHALL MEET THE LEAD FREE REQUIREMENTS AS NOTED IN SECTION 1417 OF THE SAFE DRINKING WATER ACT. 4.4 WATER HEATERS: IF NEW WATER HEATER(S) ARE TO BE INSTALLED THEY SHALL BE AS SPECIFIED ON THE PLANS, AND SHALL BE OF COMMERCIAL GRADE, AND AGA APPROVED IF GAS FIRED AND UL APPROVED IF ELECTRIC. HEATERS SHALL HAVE A 150 PSI WORKING PRESSURE RATING. WATER HEATERS AND ALL COMPONENTS SHALL MEET THE LEAD FREE REQUIREMENTS AS NOTED IN SECTION 1417 OF THE SAFE DRINKING WATER ACT. WATER HEATER INSTALLATION MANUALS SHALL BE GIVEN TO THE OWNER. SEE PLUMBING FIXTURE SCHEDULE 5. EXECUTION: 5.1 ALL PLUMBING FIXTURES, EQUIPMENT AND PIPING SHALL BE INSTALLED PER LOCAL CODE AND ESTABLISHED INDUSTRY PRACTICES. LOCATE ALL PIPING, AS SHOWN ON THE PLANS. 5.2 COORDINATE WITH ALL OTHER TRADES TO AVOID INTERFERENCE, AND ADHERE TO ALL SPECIFICATIONS AND MANUFACTURER GUIDELINES. 5.3 RUN ALL DOMESTIC WATER PIPING AS HIGH AS POSSIBLE INSTALL HANGERS AND STRAPPING, ALLOWING FOR EXPANSION AND CONTRACTION OF PIPING. DO NOT HANG OR SUPPORT OTHER EQUIPMENT OR PIPING FROM WATER LINES. SEPARATE HOT AND COLD WATER LINES A MINIMUM OF SIX (6) INCHES. INSULATE ALL PIPING WITH 1' INSULATION WHICH MEETS OR EXCEEDS 25/50 RATINGS. 5.4 INSTALL SOIL, WASTE AND VENT PIPING WITH A MINIMUM SLOPE OF 1/4' PER FOOT IN THE DIRECTION OF FLOW FOR DRAINS AND AGAINST THE FLOW OF VENT GASSES. NO FIXTURE SHALL HAVE AN S -TRAP OR BE DOUBLE TRAPPED. 5.5 INSULATE ALL DOMESTIC WATER PIPING, HORIZONTAL WASTE PIPING AND STORM DRAINAGE PIPING ABOVE CEILINGS. 6, VALVES: LOCATE VALVES SO AS TO BE ACCESSIBLE AND SO THAT SEPARATE SUPPORT CAN BE PROVIDED WHEN NECESSARY. INSTALL ALL STEMS UPRIGHT. DO NOT INSTALL VALVES OF DISSIMILAR COMPOSITION WITHOUT AN APPROVED DIELECTRIC FITTING. 7. TEST AND STERILIZATION: FLUSH, TEST AND STERILIZE ALL PLUMBING PIPING INCLUDING DRAINS, WASTE VENTS AND WATER PIPING PER LOCAL CODES AND REGULATIONS. LINE TYPES: SANITARY PIPING VENT PIPING COLD WATER PIPING - - - - - - - - 110 DEG HOT WATER PIPING - - - - - - - - - - - UNDER SLAB WATER PIPING EXISTING PIPING SHOWN IN A LIGHTER SHADE GENERAL NOTES 1. PLUMBING CONTRACTOR SHALL VERIFY WITH THE LOCAL HEALTH DEPARTMENT AND /OR WATER COMPANY AS TO THE METER AND VALVING ARRANGEMENTS OF THE DOMESTIC WATER SERVICE WHICH ENTERS THE BUILDING. IF A BACKFLOW PREVENTER AND /OR PRESSURE REDUCING VALVE IS REQUIRED, THE PLUMBER SHALL FURNISH AND INSTALL SAME PER LOCAL AND STATE REQUIREMENTS. 2 PLUMBING CONTRACTOR SHALL PROVIDE AND INSTALL STOP VALVES AT FINISHED WALL SURFACE 3. ALL PLUMBING PIPING SHALL BE ROUTED UNDER THE FLOOR, ABOVE THE CEILING, OR LOCATED WITHIN WALLS OR PLUMBING CHASES. EXPOSE PIPING ONLY WHERE NECESSARY TO CONNECT TO EQUIPMENT. 4. SEE ARCHITECTURAL PLANS FOR FINAL EQUIPMENT LOCATIONS. COORDINATE WITH EQUIPMENT SUPPLIER AND THE GENERAL CONTRACTOR FOR FINAL WALL LOCATIONS. 5. PROVIDE WATER CONNEC11ONS AS REQUIRED, ANGLE STOP AND ESCUTCHEON PLATE FOR ALL FINAL WATER CONNECTIONS. 6. FURNISH BURST PROOF BRAIDED FLEXIBLE CONNECTORS FOR FINAL CONNECTIONS TO SINKS AND OTHER EQUIPMENT. 7. FURNISH TUBING AND FITTINGS, AS REQUIRED, FOR ALL FINAL CONNECTIONS. 8. PROVIDE AIR CHAMBER TYPE WATER HAMMER ARRESTORS OR ACCEPTABLE FACTORY MANUFACTURED SUBSTITUTES AT ALL WATER ROUGH -IN LOCATIONS. 9. ALL COMPONENTS OF THE POTABLE WATER SYSTEM SHALL COMPLY WITH THE LEAD FREE REQUIREMENTS AS NOTED IN SECTION 1417 OF THE SAFE DRINKING WATER ACT. 10. ALL PLUMBING WORK SHALL BE PERFORMED IN FULL COMPLIANCE WITH THE LOCAL PLUMBING CODE, HEALTH REGULATIONS, AND LOCAL ORDINANCES. 11. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR ALL PERMIT FEES, UTILITY TAP FEES, AND INSPECTION FEES AS REWIRED. 12. THE CONTRACTOR SHALL COORDINATE THE LOCATION OF HIS FLOOR DRAINS, HUB DRAINS AND CONNECTION POINTS WITH THE GENERAL CONTRACTOR. THE PLUMBING CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING HIS BID. DOMESTIC WATER CALC. DESCRIPTION QUANTITY FU EACH TOTAL FU MOP SINK 1 3 3 DRINKING FOUNTAIN 1 .25 .25 WATER CLOSET 2 5 10 LAVATORY 2 2 4 TOTAL 17.25 17.25 FIXTURE UNITS = 18.8 GPM = 1" DOMESTIC WATER SERVICE PER THE 2010 FLORIDA PLUMBING CODE CROSS CONNECTION CONTROL SCHEDULE FIXTURE MAKE MODEL ASSE, ASME OR MODEL ACCESSORIES NOTES ANSI STANDARD MOP SINK FAUCET CONTAINS WATTS do 9DM2 -S ASSE 1012 INTERGRAL BACKFLOW DEVICE INTEGRAL - ASSE 1001 LAVATORIES AIR GAP - ASME A1121.2 WATER HEATER WATTS LFN360 ANSI Z21.22 BUILIDNG WATER SUPPLY WATTS LF009 M2 -QT ASK 1013 - c o OR EQUAL SECURED TOP PROVIDE APPROPRIATE BACK FLOW PREVENTER AT OTHER EQUIPMENT AS REQUIRED BY CODE PLUMBING FIXTURE SCHEDULE PLAN MARK MANUFACTURER MODEL ACCESSORIES NOTES ® FLOOR DRAINS WADE OR EQUAL 1103STD6 P -TRAP 7 \ MS (TYPICAL) W /6" TRAP PRIMER design associate: O bFORD STRAINER =LL +O FLOOR CLEANOUT WADE OR EQUAL 6000 NICKEL BRONZE 4-a c o �-J 0o g SECURED TOP WH A.O. SMITH DSE -10 U Q 10 GAL 3 KW (WATER HEATER) I I I 1 24 GPH REC. 0 50' RISE SEE ARCHITECTURAL SHEET A8.0 FOR ADDITIONAL FIXTURE SPECIFICATIONS 4" 3" SANITARY ISOMETRIC DIAGRAM SCALE: NTS 3/4" 1/2 1 3/4„ WC MS (' WC LAV i I LAV I OWFI i 1/2 DF DOMESTIC WATER ISOMETRIC DIAGRAM SCALE: NTS KEYED NOTES: O1 MAKE CONNECTION TO NEW SANITARY LINE (MIN. 4') TO SERVE PREMISES. FIELD VERIFY EXACT LOCATION AND INVERT ELEVATION OF POINT OF CONNEC11ON AND ALL REQUIREMENTS PRIOR TO COMMENCING WORK. SEE CIVIL PLANS FOR CONTINUATION. OEXTEND VENTS THROUGH ROOF SUCH THAT MINIMUM 10' CLEARANCE TO AIR INTAKES IS MAINTAINED. O3 MAKE 1' CONNECTION TO EXISTING WATER SERVICE IN AT EXISTING TOILET ROOMS WITHIN THE BUILDING ( +/- 300' AWAY). ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH LOCAL CODES. CONTRACTOR SHALL FIELD VERIFY REQUIREMENTS PRIOR TO BID. BID SHALL INCLUDE ALL WORK NECESSARY FOR A FULLY OPERATIONAL SYSTEM. O4 PROVIDE AND INSTALL TANK TYPE WATER HEATER AS SCHEDULED ON THIS SHEET. WATER HEATER TO BE MOUNTED ON PLATFORM ABOVE TOILET ROOMS. INSTALL WATER HEATER PER DETAIL ON THIS SHEET. /-VTRO LAV WC f FCO I aesign, inc, p.o. box 14.2116 coral gables, florida 33114.2116 v. 305.443.3100 f. 305.259.3986 e. info @whadesign.com architect of record: William Arthur License Number: 0012074 J- ..i _ . L -L _! _ _a _i._ _ L. _i._ III II n SANITARY PLAN SCALE: 3/16" = V -0" ■ 1 ■ ■ ■ �� O ■ ■ ■ °-1 �P { 1_ :� ° %I IIIIIIIIi(1ilf Illlllilllili n )DOMESTIC WATER PLAN SCALE: 3/16" = V -0" n KEY PLAN SCALE: NTS These plans and specifications are the exclusive property of MA Design. Any reproduction, modification, disclosure, and/or use of these materials (or any portion thereof) without WHA Design's prior written consent is strictly prohibited. t/t1 ��•'• 1 •W� } r ..� V 4 �W W qu. � • •�CIOO 7 \ MS PiP s,� � �'. sa design associate: O bFORD J- ..i _ . L -L _! _ _a _i._ _ L. _i._ III II n SANITARY PLAN SCALE: 3/16" = V -0" ■ 1 ■ ■ ■ �� O ■ ■ ■ °-1 �P { 1_ :� ° %I IIIIIIIIi(1ilf Illlllilllili n )DOMESTIC WATER PLAN SCALE: 3/16" = V -0" n KEY PLAN SCALE: NTS These plans and specifications are the exclusive property of MA Design. Any reproduction, modification, disclosure, and/or use of these materials (or any portion thereof) without WHA Design's prior written consent is strictly prohibited. project history: Mechanical 10 -07 -14 A2 Fire Alarm /Plumbing 3 -25 -15 project information: date: 07/08/13 project number: 13 -20 sheet title: PLUMBING PLAN sheet number: ■ Pi 884 -13 pl.0.dwg U) L W E L =LL v♦ MIX .E (VI C) M 4-a c o �-J 0o g Co �}- m O E ,c .S U Q c 3 CL o project history: Mechanical 10 -07 -14 A2 Fire Alarm /Plumbing 3 -25 -15 project information: date: 07/08/13 project number: 13 -20 sheet title: PLUMBING PLAN sheet number: ■ Pi 884 -13 pl.0.dwg