14-952-037ELECTRICAL SPECIFICATIONS 1. ALL WORK TO BE IN ACCORDANCE WITH THE RULES AND REGULATION OF THE LOCAL AUTHORITIES HAVING JURISDICTION AND THE MOST RECENT EDITION OF NATIONAL ELECTRIC CODE. 2. FURNISH ALL MATERIALS, EQUIPMENT, LABOR, & SERVICES REQUIRED FOR THE INSTALLATION OF ALL ELECTRICAL WORK & AS REQUIRED TO PROVIDE A COMPLETE & OPERABLE ELECTRICAL SYSTEM AS INDICATED ON THE DRAWINGS. 3. CONTRACTOR SHALL GUARANTEE WORK INSTALLED UNDER THE CONTRACT TO BE FREE FROM DEFECTIVE WORKMANSHIP & MATERIALS, USUAL WEAR EXCEPTED, & SHOULD ANY SUCH DEFECTS DEVELOP WAN A PERIOD OF ONE YEAR ACCEPTANCE OF THE BLDG. BY THE YEAR, THIS CONTRACTOR SHALL REPAIR AND /OR REPLACE ANY DEFECTIVE ITEMS & DAMAGE RESULTING FROM FAILURE OF THESE ITEMS, AT NO EXPENSE TO THE OWNER. 4. INCIDENTAL ITEMS NOT INDICATED ON THE DRAWINGS, NOR MENTIONED IN THE SPECIFICATIONS, THAT CAN BE LEGITIMATELY & REASONABLE BE INFERRED TO BELONG TO THE WORK DESCRIBED OR BE NECESSARY IN GOOD PRACTICE TO PROVIDE A COMPLETE SYSTEM, SHALL BE FURNISHED & INSTALLED AS THOUGH ITEMIZED HERE IN EVERY DETAIL. 5. NOTIFY ARCHITECT IMMEDIATELY OF POSSIBLE CONFLICTS WITH STRUCTURE, MECHANICAL, OR OTHER FEATURES. WHERE JOB CONDITIONS REQUIRE REASONABLE CHANGES IN LOCATIONS & ARRANGEMENT OF INDICATED EQUIP., CONDUIT, OUTLETS, OR WIRING, CONTRACTOR SHALL MAKE SUCH CHANGES WITHOUT COST TO OWNER. 6. OWNER SHALL FILE PLANS WITH AND OBTAIN APPROVALS FROM MUNICIPAL AGENCIES. ALL PERMITS AND CERTIFICATES OF INSPECTION SHALL BE OBTAINED AND PAID FOR BY THE OWNER. 7. CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING. BIDS SHAM SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS. 8. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING, OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK HEREIN SPECIFIED. ALL OPENINGS THROUGH STRUCTURALLY SUPPORTED SLABS MUST BE COREBORED, SLEEVED, GROUTED, SEALED AND MADE WATERPROOF. SLEEVES MUST EXTEND AT LEAST 2" AFF. ALL SLEEVES, OPENINGS, ETC. THROUGH FIRE RATED WALLS AND FLOORS SHALL BE SEALED AFTER CONDUIT INSTALLATION TO RETAIN FIRE RATING. 9. ALL ELECTRICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIR. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL, SUCH AS CHANNELS, RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK AND SHALL BE SECURED TO THE BUILDING - STRUCTURE, NOT TO PIPING OR DUCTWORK. ALL CONDUIT SHALL BE CONCEALED WHERE POSSIBLE. EXPOSED CONDUIT SHALL BE RUN IN STRAIGHT LINES PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES AND SEPARATED AT LEAST 3" FROM WATER LINES WHEREVER THEY RUN ALONG SIDE OR ACROSS SUCH LINES. 10. EVERY PART OF THE INSTALLATION SHALL BE TESTED, OPERATED AND LEFT IN PERFECT a WORKING ORDER. 11. IT SHALL BE THIS CONTRACTOR'S RESPONSIBILITY, PRIOR TO ANY INDIVIDUAL CIRCUITS INSTALLATION, TO VERIFY WITH ALL OTHER TRADES CONCERNED THAT THE CIRCUIT WITH DEVICES AS DRAWN IS ADEQUATE IN SIZE AND MAKE -UP FOR THE MECHANICAL AND /OR KITCHEN EQUIPMENT TO BE INSTALLED. IF ANY CONFLICT IN VOLTAGE, PHASE OR LOAD IS ENCOUNTERED WHICH WOULD ALTER THE CIRCUIT SIZE, THIS CONTRACTOR SHALL NOTIFY THE ENGINEER OR OWNER IMMEDIATELY. FAILURE TO DO SO SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT CIRCUIT CHANGE DIRECTLY UPON THE CONTRACTOR. 12. GENERAL SCOPE OF WORK CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, SUPPLIES, EQUIPMENT AND FEES REQUIRED TO COMPLETELY INSTALL, TEST AND PLACE THE HEREIN SPECIFIED EQUIPMENT, COMPONENTS, CONTROLS, AND SYSTEMS IN SERVICE. COMPLETE POWER AND LIGHTING SYSTEMS INCLUDING ALL PANELS AND COMPLETE BRANCH CIRCUIT WIRING SYSTEM TEMPORARY ELECTRICAL SERVICE AS REQUIRED FOR CONSTRUCTION COMPLETE TELEPHONE CONDUIT SYSTEM INCLUDING CONDUIT FROM POINT OF CONNECTION TO UTILITY COMPANY SERVICE AND ALL TERMINAL DEVICES, BOXES, CONDUIT, PLATES, ETC. PROVISIONS FOR FIRE ALARM SYSTEM AS REQUIRED BY CODE p WIRING AND FINAL CONNECTION TO ALL SIGNS AND GRAPHICS TESTING OF ALL CABLES AND CIRCUIT WIRING AFTER INSTALLATION TESTING OF ALL ELECTRICAL EQUIPMENT WARRANTY OF ALL WORK FOR A PERIOD OF ONE YEAR FROM DATE OF PROJECT CLOSE -OUT 13. THE CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY THE AVAILABLE SHORT CIRCUIT CURRENT AT THE SUPPLY TERMINALS FROM THE POWER COMPANY & /OR MALL/SHOPPING CENTER POWER SOURCE. THE SERVICE EQUIPMENT SHALL MEET OR EXCEED THIS RATING PER N.E.C. 14. THE CONTRACTOR SHALL MAKE ARRANGEMENTS PITH THE LOCAL TELEPHONE UTILITY COMPANY FOR TELEPHONE SERVICE TO THE SPACE, CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION TO THE LEASED PREMISES SHALL BE PROVIDED WHERE REQUIRED FOR UTILITY COMPANY WIRES. 15. THIS CONTRACTOR SHALL PROVIDE, INSTALL AND CONNECT A COMPLETE SYSTEM OF GROUNDING FOR ALL EQUIPMENT AND STRUCTURES. ELECTRICAL SYSTEM AND EQUIPMENT GROUNDS SHALL COMPLY WITH ALL LOCAL, STATE AND NEC CODES AND REGULATIONS. 16. PANELBOARDS AND BREAKERS SHALL BE BY SQUARE -D OR EQUAL PANEL SHALL BE CIRCUITED SO THAT THE LOAD IS DISTRIBUTED EVENLY ACROSS ALL THREE PHASES. PANELBOARDS SHALL CONTAIN A TYPEWRITTEN DIRECTORY WITH A PLASTIC COVER AFFIXED TO THE INSIDE DOOR. 17. ALL BREAKERS SHALL BE BOLTED TYPE, THERMAL MAGNETIC WITH ALL TWO OR THREE POLE BREAKERS HAVING COMMON TRIP. CIRCUIT BREAKERS SHALL BE RATED FOR MINIMUM 10,000 AMP SYMMETRICAL SHORT CIRCUIT CURRENT AT 120/208V. CIRCUIT BREAKERS SERVING LIGHTING CIRCUITS SHALL BE RATED FOR SWITCH SERVICE. 18. WIRING DEVICES: WALL SWITCHES, SINGLE POLE, DOUBLE POLE, AND THREE WAY SHAM BE GENERAL DUTY, FLUSH, TOGGLE SWITCHES; SPECIFICATION GRADE, 20A, 120 /277V, WITH SCREW TERMINALS. MANUFACTURES SHALL BE HUBBELL, BRYANT, PASS & SEYMORE, OR LEVITRON. GENERAL DUTY DUPLEX RECEPTACLES SHALL BE 2 -POLE, 3-WIRE GROUNDING TYPE, SPECIFICATION GRADE, 20A, 125V, NEMA 5-208 UNLESS OTHERWISE INDICATED. MANUFACTURES SHALL BE HUBBELL, BRYANT, PASS AND SEYMORE, OR LEVITRON. GROUND FAULT INTERRUPTER RECEPTACLE SHALL BE GENERAL DUTY, DUPLEX RECEPTACLES, GROUND FAULT CIRCUIT INTERRUPTER, FEED - THROUGH TYPE, CAPABLE OF PROTECTING CONNECTED DOWNSTREAM RECEPTACLES ON A SINGLE CIRCUIT, GROUNDING TYPE UL -RATED CLASS A, GROUP 1, 20A, 120V, 60 HZ; WITH SOLID -STATE GROUND FAULT SENSING AND SIGNALING; WITH 5 MILLIAMPERES GROUND - FAULT TRIP LEVEL; IN NEMA 5-158 CONFIGURATION. MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS & SEYMORE, OR LEVITRON. DUPLEX ISOLATED GROUND TYPE RECEPTACLE MALL BE 2 -POLE, 4 -WIRE, 15A STRAIGHT BLADE DEVICE WITH SEPARATE ISOLATED GROUND AND BUILDING GROUND CONNECTIONS, IN NEMA 5-15R CONFIGURATION, AS MANUFACTURED BY HUBBELL IG -5362. WIRING DEVICE ACCESSORIES INCLUDING ALL WALL PLATES SHALL BE PROVIDED AT EACH DEVICE. WAIL PLATES SHALL BE SAME COLOR AS DEVICE AND MANUFACTURED AS A COMPANION TO THE DEVICE. ANY ELECTRICAL OUTLETS WITHIN 4 FEET OF A SINK SHALL BE GFI PROTECTED. PROVIDE EITHER INDIVIDUAL GFI DEVICES OR GFI CIRCUIT BREAKERS, UNLESS SPECIFICALLY NOTED ON THE DRAWINGS OR SCHEDULES. PROVIDE A 120 VOLT RECEPTACLE WITHIN 25 FEET OF ALL HVAC EQUIPMENT. ALL EXTERIOR RECEPTACLES AND DEVICES SHALL BE WEATHERPROOF 19. ALL FEEDERS & BRANCH CIRCUITS SHALL BE THHN/THWN (75' C). DESIGN IS BASED ON COPPER CONDUCTORS & ALL BRANCH CIRCUIT WIRING SHALL BE COPPER. ALL WIRING SHALL BE IN CONDUIT OR MC TYPE. ADDITIONAL CONDUCTOR SPECIFICATIONS: #10 AND SMALLER - SOUD WITH SINGLE BRAID. #8 AND LARGER - STRANDED WITH AT LEAST DOUBLE BRAID. MINIMUM WIRE SIZE SHALL BE #12 (#14 MAY BE USED FOR CONTROLS) WIRES SHALL BE COLOR CODED IN KEEPING WITH NEC STANDARDS ELECTRICAL LEGEND POWER SYMBOL DESCRIPTION (� DUPLEX RECEPTACLE MOUNTED AT 18 "AFF UNLESS NOTED OTHERWISE QUAD PLEX RECEPTACLE MOUNTED AT 150AFF UNLESS NOTED OTHERWISE W DUPLEX ISOLATED GROUND TYPE RECEPTACLE MOUNTED AT 15 "AFF UNLESS NOTED OTHERWISE -4W -S/N QUAD PLEX ISOLATED GROUND TYPE RECEPTACLE MOUNTED AT 15 "AFF UNLESS NOTED OTHERWISE CKT. DUPLEX GROUND FAULT INTERRUPTING TYPE RECEPTACLE Q JUNCTION BOX PHASE DISCONNECT SWITCH SERVICE SINGLE SECTION PANELBOARD COT. HEAVY DUTY RECEPTACLE (VERIFY NEMA CONFIGURATION) SIZE CIRCUIT HOME RUN COMMUNICATIONS b =�0 ROUGH -IN FOR TELEPHONE DATA LINE OR DATACOM MOUNTED AT 15 "AFF UNLESS NOTED OTHERWISE LIGHTING CONTROL SQE WALL MOUNTED TOGGLE SWITCH 0 OCCUPANCY SENSING CONTROL, VERIFY EQUIPMENT SPEC WITH ROOM LAYOUT AND OWNER IN FIELD (LEVITON OR EQUAL) MC TIME CLOCK A PHOTOCELL IC LIGHTING CONTACTOR ABBREVIATIONS AFF ABOVE FINISHED FLOOR KW KILOWATT A AMPERE NIC NOT IN CONTRACT ELEC ELECTRICAL PNL PANEL EXIST EXISTING SW SWITCH EQUIP EQUIPMENT TYP TYPICAL, , FA FIRE ALARM V VOLT G,GND GROUND W WIRE GFI GROUND FAULT INTERRUPTER WP WEATHERPROOF HP HORSEPOWER PH PHASE IG ISOLATED GROUND XFMR TRANSFORMER PANEL M i 400A h�C:R 120/208V -3PH -4W -SIN 100 A ML0 1201208V - 3PH -4W -S/N _ 42 POLE CKT. BRKR. ...... ..._ ........................... SERVICE _...................................._............ ............................... LOAD , ............................... PHASE LOAD SERVICE BRKR. COT. BRKR. SIZE NO. A b =�0 _..........._.... VA ............ ........... SQE f NO. 1 100/3 PANEL A 8040 A 6900 RTU -1 m 6013 2 q 3 7420 B 6900 5 7640 C 6900 6 7 20/1 SPARE - A 3600 RTU -2 45/3 8 9 20 /1 SPARE - B 3600 10 11 20/1 SPARE - C 3600 12 13 20/1 SPARE - A 3600 RTU -3 45/3 14 15 20/1 SPARE - B 3600 16 17 20/1 SPARE A C 3600 18 19 20/1 SPARE - A 3600 RTU4 45/3 20 21 20/1 SPARE LIGHTING - SALES B 3600 22 23 20/1 SPARE 19 C 3600 24 25 20/1 SPARE - A 3600 RTU -5 45/3 26 27 20/1 SPARE 20/1 B 3600 28 29 20/1 SPARE - C 3600 30 31 20/1 SPARE 300 A 2770 RTU-6 30/3 32 33 20/1 SPARE - B 2770 34 35 20/1 SPARE - C 2770 36 37 20 /1 SPARE - A - SPARE 20/1 38 39 20/1 SPARE 32 B - SPARE 20/1 40 41 20/1 SPARE - C - SPARE 20/1 1 42 :....., p .. _.._ CONNECTED LOAD A:1-1,2­1.1. 32110 ..._, VA 95310.. VA :TOTAL LOAD 264.6 2011 SPARE 13: 39490 iVA .. 95310 VA .DEMAND LOAD 264.6 _ SPARE 20/1 C. 31710 VA PANEL A I i 100 A ML0 1201208V - 3PH -4W -S/N 42 POLE CKT BRKR. SERVICE w N m...... _ _ �. LOAD w._. ,..� PHASE LOAD o BRKR. CKT NO. SIZE b =�0 _ _w..r..u.�. ....._... _....w._... _... w.__ ._ .._..__.,.. ..... ..._..__ ".'S'ERVICE ...._._...._ SIZ£ _._..__r . NO, 1 20/1 LIGHTING - SALES 1020 A 1080 SALES FLOOR RECEPTACLES 2011 2 3 20/1 LIGHTING - SALES 1020 B 900 SALES FLOOR RECEPTACLES 20/1 4 5 20/1 LIGHTING - SALES 1020 C 1080 SALES FLOOR RECEPTACLES 20/1 6 7 20/1 LIGHTING - SALES 740 A 900 SALES FLOOR RECEPTACLES 2011 8 9 20/1 LIGHTNG - SALES 740 B 900 STORAGE ROOM RECEPTACLES 20/1 10 11 20/1 LIGHTING - SALES 1270 C 720 TELEPHONE BOARD 20/1 12 13 20/1 LIGHTNG - SALES 1020 A 540 RESTROOM/WATER COOLER REC 20/1 14 15 20/1 LIGHTNG - SALES 1020 B 360 CASHWRAP 20/1 16 17 20/1 LIGHTING - SALES 740 C 1080 RTU SERVICE RECEPTACLES 20/1 181 19 2011 LIGHTING - SALES 740 A 720 SHOW WNDOdV RECEPTACLES 20/1 20 21 20/1 LIGHTING - SALES 740 B 540 SHOW WNDCW RECEPTACLES 20/1 22 23 20/1 LIGHTNG - RESTROOMS/EF -1 530 C SPARE 2011 24 25 20/1 LIGHTNG - EXTERIOR 300 A 680 LIGHTING - STORAGE 20/1 26 27 20/1 EXTERIOR SIGN 1200 13 SPARE 2011 28 29 2011 EXTERIOR SIGN 1200 C - SPARE 2011 30 31 2011 TIMECLOCKIPHOTOCELL 300 A - SPARE 20/1 32 33 20/1 ISPARE - B - SPARE 20/1 34 35 20/1 SPARE C - SPARE 20/1 36 37 2011 SPARE - A - SPARE 20/1 38 39 2011 SPARE - B - SPARE 20/1 40 41 20/1 SPARE C - SPARE 20/1 42 i CONNECTED LOAD A: $040 €VA ................ ._.._ _.... 231A 00 V :TOTAL LOAD 641 _...._. ..8 :.... .............7420£VA_ _..._......1 23100 _ ..... ...._..................__._._ . _....._ VA..._DEMAND.LOAD ......... 641 C: 764W VA VA _... 1�3 ►1��1 ►1aNJ /Glc1UIA I • EXISTING CONDITION NOTES rr « + r�r �•�r.. r � r « � r �+ r �y• « r+ ••« •• r• r : � r +r r GENERAL NOTES - ONE LINE 1. ALL WORK AND MATERIALS BY THE ELECTRICAL CONTRACTOR, UNLESS OTHERWISE NOTED. 2. ELECTRICAL SERVICE: EXISTING 600 AMP, 120/208 VOLT 3 PHASE 4 WIRE MAIN DISTRIBUTION PANEL. AND CONDUIT STUB INTO SPACE TO REMAIN. ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUCTORS FROM DISTRIBUTION PANEL TO PANEL 'M' AND EXTEND CONDUIT STUB TO PANEL. V. 3. COORDINATE THE INSTALLATION WITH THE POWER COMPANY AND OWNER REPRESENTATIVE FOR THE EXACT REQUIREMENTS, INCLUDING A.I.C. REQUIREMENTS FOR THE PANELBOARDS AND CIRCUIT BREAKERS. 4. VERIFY SERVICE VOLTAGE AND AMPERAGE WITH POWER COMPANY PRIOR TO BID. 5. WIRE AND CONDUIT SIZES SHOWN ARE FOR COPPER CONDUCTORS WITH 751C RATED INSULATION AND ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR TO PROVIDE PROPERLY SIZED WIRE TO COMPENSATE FOR ALUMINUM FEEDER OR VOLTAGE DROP AS REQUIRED. design, ire. p.o. box 14.2116 coral gables, florida 33114.2116 s v. 305.443.3100 f. 305.259.3986 e. info @whadesign.com architect of record: William Arthur License Number: 0012074 4� +�r��r 4 ,gr o• ,.� of `. • u► w r"♦ ts, l�lI�% design associate: bFORD These plans and specifications are the exclusive property of WHA Design. Any reproduction, modification, disclosure, and/or use of these materials (or any portion thereof) without WHA Design's prior written consent is strictly prohibited. W E e r 3: �� w - A A project information: date: 07/08/13 project number: 13 -20 sheet title: ONE -LINE DIAGRAM ffig ep sheet number. 7tl: E3 a 01. V., file: 88413 e3.0.dwg 0 . X o (U co� b =�0 �.« ® - A A project information: date: 07/08/13 project number: 13 -20 sheet title: ONE -LINE DIAGRAM ffig ep sheet number. 7tl: E3 a 01. V., file: 88413 e3.0.dwg