Loading...
14-952-0301. THIS CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES IN LOCATING DUCTWORK, PIPING AND EQUIPMENT TO AVOID ANY INTERFERENCE. 2. COORDINATE INSTALLATION OF NEW DUCT W/ STRUCTURE. 3. CONTRACTOR TO INSTALL ALL WORK IN STRICT COMPLIANCE WITH LOCAL CODES AND ORDINANCES. 4. MECHANICAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND EQUIP. SUBMITTAL PRIOR TO INSTALLING OR FABRICATING ANY DUCTWORK. 5. PROVIDE FIBERGLASS INSULATION BLANKET ABOVE TOPS OF ALL SUPPLY AIR DIFFUSERS. 6. PROVIDE ADJUSTABLE VOLUME DAMPER AT ALL SUPPLY BRANCH, RETURN DUCTWORK AND EXHAUST REGISTER. 7. PROVIDE TURNING VANES AT ALL ELBOWS (TYPICAL). 8. MECHANICAL CONTRACTOR TO REPLACE FILTER AFTER CONSTRUCTION COMPLETED. 9. MECHANICAL CONTRACTOR TO PROVIDE 12" HIGH REFLECTIVE UNIT NUMBERS WITH SPECIFIC A/C UNIT # TO BE POSTED ON EACH UNIT ON THE CONTROL PANEL DOOR AND SIDE WITH THE DISCONNECT IN LOCATION VISIBLE FROM THE 10. PROVIDE RTU AUTOMATIC O.A. DAMPER SHUT -OFF CONTROL DURING UNOCCUPIED MODE. F914ftemius MIN. DUCT CONNECTION/ NECK SIZE f.-- TAG - - �Ja AIR FLOW------ _ , X: CF �614" 0911 Lire] 19 PROVIDE AND INSTALL NEW ROOF TOP UNIT AS SHOWN IN SCHEDULE ON THIS SHEET. UNIT SHALL BE LOCATED SUCH THAT SUPPLY AND RETURN DUCTWORK DROP BETWEEN JOISTS. RUN CONDENSATE LINE TO NEAREST EXISTING CONDENSATE DISCHARGE. VERIFY LOCA11ON OF DRAIN IN FIELD. VERIFY OUTSIDE AIR INTAKE IS A MINIMUM OF 10' FROM ANY EXHAUST OR FLUE. MODIFY EXISTING ROOF OPENING FOR RTU -1,2,3 CURB INSTALLATION. PROVIDE AND INSTALL U.L LISTED IONIZA11ON TYPE SMOKE DETECTOR INTERLOCKED WITH RTU CONTROLS TO SHUT RTU DOWN UPON ACTIVATION OF DETECTOR. LOCATE IN SUPPLY AIR DUCTWORK. PROVIDE AND INSTALL ONE PIECE PROGRAMMABLE THERMOSTAT AT 54" AF.F. PER ADA. COORDINATE LOCATIONS WITH OTHER ELEMENTS OF WALL /COLUMN. VERIFY EXACT LOCATIONS IN FIELD. ALL THERMOSTATS ON EXTERIOR WALL TO BE MOUNTED ON INSULATED BACK BOARD. EXTEND 8 "0 EXHAUST DUCT DOWN FROM EF -1 ON ROOF AND CONNECT TO EXHAUST GRILLES IN TOILET ROOM AND ABOVE MOP SINK. BALANCE AS INDICATED. PROVIDE BACK DRAFT DAMPER AT EACH GRILLE. SEE FAN DETAIL ON SHEET M -2 AND FAN SCHEDULE ON THIS SHEET. VERIFY FAN OUTLET IS 10' MINIMUM FROM ANY AIR INTAKE, VERIFY LOCATION. OUTSIDE AIR CALCULATION BASED FBC TABLE 403.3 PLAN MARK 1. Summary Ventilation Sizing Method ........ ............................ Sum of Space OA Airflows Design Ventilation Airflow Rate ................................. ............................... 2017 CFM 2. S ace Ventilation Analysis Table MODULE FRAME Zone Name I Space Name Mult Floor Area (ft =) Maximum Occupants Maximum Supply Air (CFM) Required Outdoor Air (CFM/person) Required Outdoor Air (CFM/Rx) Uncorrected Outdoor Ai (CFM S3 TITUS TDC -AA Zone 1 DRYWALL R1 TITUS PAR -AA 24x24 LAY -IN E1 TITUS 50F 12x12 LAY -IN SALES 11 6722.0 70.0 7134.2 0.00 0.30 20161 TIMER RELAY .E RR passage 1 223.0 2.0 202.41 0.001 0.00 01 AIR TYPE storage 1 750.0 0.0 596.8 0.00 0.001 01 NOTES 4 Totals find. Space Multi C O NG NG 79334 = 20113. NUMBER MIN. IN (WC) PROVIDE TOTAL 2150 CFM AIR DEVICE SCHEDULE PLAN MARK MANUFACTURER\ MODEL NUMBER MODULE FRAME S1 11TUS TDC -AA 24x24 LAY -IN S2 TITUS TDC -AA 2424 DRYWALL S3 TITUS TDC -AA 12x12 DRYWALL R1 TITUS PAR -AA 24x24 LAY -IN E1 TITUS 50F 12x12 LAY -IN ALL TITUS DIFFUSERS do GRILLES SHALL BE ALUMINUM. PROVIDE TITUS SECTORIZING BAFFLE AS REQUIRED WHERE DIRECTIONAL ARROWS ARE SHOWN ON PLAN. HVAC LEGEND YES NO 'o' SE- SP r• ELECTRICAL TOILET • OOO EMAUST GRILL FIRE DAMPER(S) REMARKS r% DUCT MOUNTED SMOKE DETECTOR CL DIRECTION OF FIRE RATED ENCLOSURE T THERMOSTAT t •O 7• HVAC DESIGN REQUIRES: YES NO MODEL TYPE SP DUCT SMOKE DETECTOR ELECTRICAL OPTIONS FIRE DAMPER(S) REMARKS r% SMOKE DAMPER(S) CL PLAN FIRE RATED ENCLOSURE SUPPLY OUTSIDE FIRE RATED ROOF ASSEMBLY >1 COOLING CAPACITY FIRE STOPPING HEATING CAPACITY EF -1 SMOKE CONTROL GB -081 -6 ROOF MTD EXHAUST FAN SCHEDULE PLAN MANUFACTURER MODEL TYPE SP CFM ELECTRICAL OPTIONS SONES REMARKS CONTROL MARK CL PLAN MANUFACTURER SUPPLY OUTSIDE EXTERNAL >1 COOLING CAPACITY HEATING CAPACITY EF -1 GREENHECK GB -081 -6 ROOF MTD 0.25" 225 120/1 /60 1/6 HP ROOF CURB BACKDRAFT DAMPER 4.8 F.C.I.C. TIMER RELAY MECHANICAL PLAN SCALE: 3/16" = V -0" L-0 C�t"Sfign, 1110ill p.o. box 14.2116 coral gables, florida 33114.2116 v. 305.443.3100 f. 305.259.3986 e. info @whadesign.com architect of record: William Arthur License Number: 0012074 �tttrr' art .,, 2 +• 4 , .".n V • A /1n • ')� Sf ATE ORI NA design associate: bFORD These plans and specifications are the exclusive property of WHA Design. Any reproduction, modification, disclosure, and/or use of these materials (or any portion thereof] without WHA Design's prior written consent is strictly prohibited. c� ROOFTOP UNIT SCHEDULE L (D CL PLAN MANUFACTURER SUPPLY OUTSIDE EXTERNAL >1 COOLING CAPACITY HEATING CAPACITY ENTERING DEGREES AIR F AMBIENT FILTER HEATING COOLING T -STAT i-i U_ .E OPERATING MARK MODEL AIR (CFM} AIR (CFM) S.P. MOTOR AIR TYPE STAGS (} STAGES () TYPE �-�' PH HZ MCA/MQCP WEIGHT NOTES 4 C O NG NG NUMBER MIN. IN (WC) MBH/TON EER /SEER SENSIBLE(MBH) INPUT(MBH) OUTPUT (MBH) ELEC.(KW/MBH) DRY BULB WET BULB (DEG F) LBS RTU -1 1TRANE 3000 550 0.5' 1.00 HP 929/7.5 12.6/ 68.63 - - 13.5/46.06 78 67 95' THROW AWAY TWO TWO PROGRAMM. 208 3 60 57.5/60 1228 1,2,3,4,5,6 RTU-2 T R E 2000 375 0.5" 1.00 HP 63.49/5 /15 47.33 - - 4.5/15.35 78 67 95' THROW AWAY ONE ONE ONE PIECE 208 3 60 30.0/45 1025 1,2.3,4,5.6 RTU -3 TTRANE 2000 375 0.5' 1.00 HP 63.49/5 /15 47.33 - - 4.5/15.35 78 67 95' THROW AWAY ONE ONE ONE(�RCE PIE 208 3 60 30.0/45 1025 1,2,3.4,5,6 RTU -4 THC 60E 2000 375 0.5" 1.00 HP 63.49/5 /15 47.33 - - 4.5/15.35 78 67 95' THROW AWAY ONE ONE PROGRPIAMM. 208 3 60 30.0/45 1025 1,2,3.4.5 RTU -5 TTRANE 2000 375 0.5" 1.00 HP 63.49/5 /15 47.33 - - 4.5/15.35 78 67 95' THROW AWAY ONE ONE ONEGRCE PIE 208 3 60 30.0/45 1025 1,2,3.4,5 RTU -6 TRANE 036E TH 1200 100 0.5" 0.75 HP 38.49/3 /13 27,94 - - 4.5/15.35 78 67 95' THROW AWAY ONE ONE PIECE 208 3 60 23.1/30 773 1,2,3,4,5 N NOTES: 1. PROVIDE WITH FACTORY ROOF CURB, ECONOMIZER (O.A. HOOD FOR RTU -6) WITH BAROMETRIC RELIEF, AND SUPPLY SMOKE DETECTOR. 2. CONTRACTOR SHALL INSTALL ALL NEW FILTERS PRIOR TO TEST AND BALANCE WORK. 3. RUN CONDENSATE LINE TO NEAREST EXISTING CONDENSATE DISCHARGE. 4. PROVIDE WITH FACTORY FITTED BURGLAR BARS, PRODIGY M2 WITH BACNET CONTROLS, HACR BREAKERS, NON -FUSED SERVICE DISCONNECTS, GFIs ETC. 5. PROVIDE WITH OVERFLOW PROTECTION DEVICE INSIDE OF THE PRIMARY DRAIN PAN WITH WATER LEVEL MONITORING. 6. MODIFY EXISTING ROOF OPENING FOR CURB INSTALLATION. MECHANICAL PLAN SCALE: 3/16" = V -0" L-0 C�t"Sfign, 1110ill p.o. box 14.2116 coral gables, florida 33114.2116 v. 305.443.3100 f. 305.259.3986 e. info @whadesign.com architect of record: William Arthur License Number: 0012074 �tttrr' art .,, 2 +• 4 , .".n V • A /1n • ')� Sf ATE ORI NA design associate: bFORD These plans and specifications are the exclusive property of WHA Design. Any reproduction, modification, disclosure, and/or use of these materials (or any portion thereof] without WHA Design's prior written consent is strictly prohibited. project history: 1a Mechanical 10 -07-14 A A A project information: date: 07/08/13 project number: 13 -20 MECHANICAL PLAN sheet number: V n KEY PLAN M100 SCALE• 1" = 50' -0" file: 884 -13 m1.0.dwg c� L (D CL >1 E M cn i-i U_ .E •X 0 5 t6 . �-' u) Q CU C =� o N :3 V 0 � E (0(/) O 4 C O Q project history: 1a Mechanical 10 -07-14 A A A project information: date: 07/08/13 project number: 13 -20 MECHANICAL PLAN sheet number: V n KEY PLAN M100 SCALE• 1" = 50' -0" file: 884 -13 m1.0.dwg