14-952-021'Masi gn' ... Jinc.
p.o. box 14.2116
coral gables, florida
33114.2116
v. 305.443.3100
f. 305.259.3986
e. info@whadesign.com
architect of record:
William Arthur
License Number: 0012074
These plans and specifications are
the exclusive property of WHA
Design. Any reproduction,
modification, disclosure, and /or use
of these materials (or any portion
thereon without WHA Design's prior
written consent is strictly prohibited. I
C,e)
CY)
J
BOTTOM OF STRUCTURE DECK
CAST IRON PIPE
CD 'cc—
t.
L 0 -C
E '=
= 0
EAL SMOKE TIGHT
BOTTOM OF STRUCTURE
0
C Co
MIN. 2x2x10 GAGE ANGLE t
MAX.
P.) EACH SIDE
(TYP.)
ATTACHED TO ALL FOUR SIDES
0 X
SEAL SMOKE TIGHT
M
OF DAMPER SLEEVE W/ 90
i� U) 0C)
CU
0
-Z5
MAX
t
(TYP.) EACH SIDE
�O
SHEET METAL SCREWS MIN.
CL
project history:
A
2 PER SIDE OR I EVERY
PIPE HANGERS (TYP.
A
project information:
8 INCHES ATTACH TO SLEEVE
AT BOTH SIDES)
project number.
13-20
PIPE INSULATION (IF APPLICABLE)
NOT TO WALL
DOES NOT CONTINUE THRU SLAB
PIPE HANGERS (TYP.
FOAM GLASS PIPE
OPENING
1" OF NON SHRINK GROUT
1 (.0
AT BOTH SIDES)
INSULATION THICKNESS
AS SPECIFIED EXTEND
PIPE
6" BEYOND WALL ON
BOTH SIDES
COMBINATION SMOKE/FIRE
PIPE
DUCT DAMPER
A/C DIFFUSER
DRYWALL TYPE "X" ON 7
......... ............ ... ............. .
......
H-1-H
P444
BUTT INSULATION TO ANGLE PROVIDE OPENING BETWEEN
DO NOT INSULATE DUCT THRU
METAL STUDS
WALL AND DAMPER SLEEVE
WALL
FOR SEALING AND/OR
AS PER MANUFACTURER
PATCHING OF OPENING
RECOMMENDATION
SEE DETAILS THIS SHEET
1/4 MAX.
"
PACK IN PULL WITH THERMA
CAULK UNDERSIDE SMOKE TIGHT
DOTED LINE INDICATE
SMOKE OR FIRE RATED
FIBER FIRE SAFING INSULATION
(TYP.)
PARTITION
CUT OPENING IN WALL
PATCH CONDITION
WITHIN 1/4" OF FOAM
--
GLASS AND SEAL
A
---------
OPENING WITH
DRYWALL MUD
NOTE:
1. SEE MECHANICAL DRAWINGS FOR DAMPER DETAILS
NOTE:
NOTE:
2. MOTOR SHALL BE MOUNTED ON DAMPER SLEEVE AND
1. ALL PIPES AND CONDUITS AT SMOKE/FIRE WALL PENETRATION SHALL
NOTE:
TO BE MONITORED TO FIRE ALARM SYSTEM
1 ALL PIPES, CONDUITS AND DUCTS AT ALL SMOKE/FIRE WALL
1. PROVIDE SUPPORT AT FLOOR PENETRATIONS FOR SAFING WHEN PIPES
3. ALL PIPES, CONDUITS, AND DUCTS AT ALL
BE DONE AT 90 DEGREES ON BO TH SIDES
PENETRATION SHALL DONE AT 90 DEGREES ON BOTH SIDES
ARE OVER 2" WIDE
SMOKE/FIRE WALL PENETRATIONS SHALL BE
DONE 90 DEGREES ON BOTH SIDES
PIPE SUSPENSION DETL.
3
2)
A7.0)TYPICAL
AT RATED PARTITION
SCALE: 3"=l'-O"
LA7 .0 ) PIPE PENETRATION DETL.
SCALE: 3"=1'-0"
A7.0 PIPE PENETRATION THRU SLAB
SCALE: 3"=1'-0"
A7.0 WALL DIFFUSER DETL. SCALE: 3"=1'-0"
BOTTOM OF STRUCTURAL DECK
2" M )
(A�.
BOTTOM OF STRUCTURAL DECK
MIN. 2x2x1 0 GAGE ANGLE
V-011
ATTACHED TO ALL FOUR SIDES
C.0
OF DAMPER SLEEVE W/ 90
SHEET METAL SCREWS MIN, •
2 PER SIDE OR 1 EVERY
METAL STUDS BEHIND I i i
i
CAULK SMOKE TIGHT
8 INCHES ATTACH TO SLEEVE
GYPSUM BOARD ------- ---- I
------- -----
(TYP.) EACH SIDE
NOT TO WALL %
SMOKE /FIRE RATED PARTITION
11N,
(SEE WALL TYPES)
lc-
---- ---------
---
QR2222222Z
I I
THERMAFIBER SAFING MATERIAL
IT
L
PACKED TIGHTLY
BLOW UP PATCH TO BE
19—
COMBINATION FIRE/SMOKE DAMPER
r ------------ i
I
ONE LAYER 5/8" TYPE "X"
6" MIN�
(SEE MECHANICAL DRAWINGS) DUCT
DUCT
L i
1
GYPSUM WALLBOARD EACH
METAL CONDUIT OR PIPING PENETRATIONS
------------
5/8' TYPE "X" DRYWALL PATCH
SIDE (SEE SIMILAR DETAIL
THIS SHEET)
FIRE RATED PARTITION OR ANY SMOKE
WALL ASSEMBLY
MULTIPLE CONDUIT
BUTT INSULATION TO ANGLE
PENETRATING FIRE/SMOKE
RATED PARTITION
FP
DO NOT INSULATE DUCT THRU
L ------
METAL RUNNERS TOP AND BOTTOM — ------- I
I
I
WALL
METAL HANGERS (TYP.)
I L------- - - - - -J
I
APPLY DRYWALL COMPOUND
PACKED DRYWALL COMPOUND FOR
TO BACK SIDE OF DRYWALL
FULL DEPTH (THICKNESS) OF DRYWALL
PATCH EACH SIDE
PROVIDE OPENING BETWEEN
SEAL SMOKE TIGHT AT ALL
NOTE:
WALL AND DAMPER SLEEVE
APPLY DRYWALL COMPOUND TO
EDGES (TYP.)
AS PER MANUFACTURER
BACK SIDE OF DRYWALL PATCH
1. PROVIDE SLEEVE FOR COMBUSTIBLE PIPES.
RECOMEMDATION
SEAL SMOKE TIGHT AT ALL
EDGES (TYP.)
2. KEEP ALL PENETRATING PIPES AND CONDUITS 6" MIN
FROM WALL OR BOTTOM OF DECK
3. ALL PIPES, CONDUITS AT ALL SMOKE/FIRE WALL PENETRATIONS
SHALL BE DONE AT 90 DEGREE ON BOTH SIDES
8
73 MULTIPLE PIPE PENETRATION THRU
6.
5 TYPICAL DRYWALL SEALING DETL. AT
ATV I INSULATED DUCT PENETRATION DETL.
SCALE: 3"=1'-0"
ATO ONE HOUR WALL DETL.
SCALE: 2"=l'-O"
LAT 0 MULTIPLE PIPE PENETRATION DETL.
0) M
SCALE: 2"=1'-0"
�ATP) RATED PARTITION PENETRATION SCALE: 3"=1'-0"
PATCH JOINT
BOTTOM OF STRUCTURAL DECK
PIPING AND/OR CONDUIT
TYPE "S" SCREWS ON STUD
A/C DUCT THRU FIRE OR
@ 3" MAX O.C. TO BE LEFT
TYPE "G" DRYWALL SCREWS
SMOKE PARTITION
EXPOSED
(LAMINATING TYPE)
3"
TO BE LEFT EXPOSED
nc)
MIN.
METAL STUD FRAMING AROUND
PIPING
t
DUCT
8"
Cl)
3"
3"
r- - - - - - - - - - - - - T - - -- - - - - -- -
A/C DUCT CLEAR
MAX.
MAX. z
Q0
5/8" TYPE "X" DRYWALL PATCH
(0
ELECTRICAY
F—
JOINT
18" 18" 18"
JOINT LOCATION WHEN
CLEAR CLEAR CLEAR
SECOND LAYER IS REQD. -------- 0
Ct METAL STUD (BEYOND)
A/C DUCT
RECESSED LIGHT FIXTURE
3" AND/OR
I
t i i i
w
CEILING
LARGER OPENING
"X"
5/8" TYPE
APPLY DRYWALL COMPOUND
(0
DRYWALL PATCH
- Z
m 5i
TO BACK SIDE AND JOINT EDGES
OF DRYWALL PATCH
24" ILIAX
SEAL SMOKE TIGHT AT ALL
EDGES (TYP.)
CEILING LINE
ROOM CORRIDOR ROOM
STUD
STUD
6" MIN. 3" DIA.
6" MIN.
NOTE:
MAX.
USE INTERMEDIATE STUD
NOTE: OPENING
WHEN SPACING IS GREATER
NSTALL COMPOUND ALONG JOINT AND
THAN 24" DUE TO LARGE DUCT
AROUND PIPE AND/OR CONDUIT PENETRATION
1. BUTTER BACKSIDES AND JOINT OF PATCH WIJOINT COMPOUND
F METAL STUDS (BEYOND)
SHALL EXTEND FULL DEPTH (THICKNESS) OF
2. LEAVE ALL SCREW HEADS EXPOSED
DRYWALL
12 TYPICAL DRYWALL PATCH DETL. AT RATED PARTITION
11 TYPICAL DRYWALL PATCH DETAIL AT RATED
r 10
9
FOR OPENING LARGER THAN 3" DIAMETER
SCALE: 3"=1'-0"
ATO) PARTITION FOR OPENING LESS THAN 3" DIAM.
SCALE- 3"=1'-0"
A7.0 DUCT FRAMING DETL.
SCALE: 2"=1'-O"
A7.0 EQUIPMENT CLEARANCE DETL. SCALE: 3/4"=1' -0"
'Masi gn' ... Jinc.
p.o. box 14.2116
coral gables, florida
33114.2116
v. 305.443.3100
f. 305.259.3986
e. info@whadesign.com
architect of record:
William Arthur
License Number: 0012074
These plans and specifications are
the exclusive property of WHA
Design. Any reproduction,
modification, disclosure, and /or use
of these materials (or any portion
thereon without WHA Design's prior
written consent is strictly prohibited. I
C,e)
CY)
(y)
E E
CD 'cc—
t.
L 0 -C
E '=
= 0
0
C Co
4-j
W
0 X
Cf) C)
M
i� U) 0C)
CU
0
-Z5
E =
0-(0
E
'0
�O
a)
2
CL
project history:
A
0
A
project information:
date:
01/20/14
project number.
13-20
sheet title:
UL Detalis
sheet number:
a7.2
file:
a7.2-ul details.dwg