14-952-006DEMOLITION NOTES: 01. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL LABOR, EQUIPMENT AND SERVICES TO PROPERLY EXECUTE THE DEMOLITION AND REMOVAL WORK INDICATED ON THESE CONSTRUCTION DOCUMENTS. 02. THE CONTRACTOR SHALL VISIT THE SITE AND INSPECT THE EXISTING BUILDING AND VERIFY THAT ALL ITEMS INDICATED TO BE EXISTING AND SO MARKED ON DRAWINGS ARE IN PLACE AND CORRECT. 03. ALL DEMOLITION WORK SHALL BE PERFORMED WITH MINIMUM DAMAGE TO THE EXISTING WORK TO REMAIN. IT SHALL BE RECOGNIZED THAT THE UTMOST CARE BE TAKEN WHEN PERFORMING THE DEMOLITION WORK. PROVIDE BARRICADES WHERE REQUIRED TO PROTECT THE PUBLIC. 04. PROVISIONS SHALL BE MADE TO ALLEVIATE THE SPREAD OF DEBRIS, DIRT AND DUST TO THE ADJACENT TENANTS. THE PROPERTY SHALL BE KEPT CLEAN AS POSSIBLE AT ALL TIMES. ANY ASBESTOS REMOVAL SHALL BE DONE PRIOR TO ANY DEMOLITION WORK, THIS WORK SHALL BE DONE BY A LICENSED ABATEMENT COMPANY. 05. ALL DEBRIS AND MATERIALS FROM THE BUILDING SHALL BE DISPOSED OF OFF THE SITE IN A LEGAL MANNER. NO RECLAIMED LUMBER OR MATERIALS SHALL BE RE -USED EXCEPT AS SPECIFICALLY APPROVED BY ARCHITECT OR OWNER. 06. WHERE DEMOLITION AND CUTTING WORK HAS OCCURRED OR WHERE EXISTING SURFACES, MATERIALS OR OTHER ITEMS HAVE BEEN DAMAGED OR DISTURBED AS A RESULT OF THIS CONTRACT, THE SAID SURFACES AND AREAS SHALL BE CAREFULLY CLOSED UP, PATCHED AND FINISHED, AND OR RESTORED AS REQUIRED TO BE CONTIGOUS TO EXISTING SURROUNDING SURFACES. 07, DO NOT REMOVE ANY STRUCTURAL COLUMNS, WALLS OR SUPPORTS. CAREFULLY REMOVE INTERIOR PARTITIONS ONLY. IF THERE IS ANY CONCERN WHETHER AN INTERIOR WALL IS BEARING OR NOT, CONTACT ARCHITECT IMMEDIATELY TO SCHEDULE A VERIFICATION TIME. 08. WHERE PLUMBING NEEDS TO BE ABANDONED, REMOVE ALL VENT STACK PIPE CAP & WALL PENETRATION, REMOVE ALL OVERHEAD WATER LINES CAP BACK AT SOURCE. ABANDONED UNDERGROUND SANITARY, GREASE OR WATER LINES SHALL BE HARD CAPPED -OFF BELOW SLAB. MAKE SURE ALL WATER HAS BEEN TURNED OFF PRIOR TO ANY WORK. ALL WORK SHALL BE DONE BY A LICENSED PLUMBER. 09. WHERE ELECTRICAL NEEDS TO BE ABANDONED, REMOVE WIRE FROM OUTLET ALL THE WAY BACK TO THE ELECTRICAL PANEL SOURCE. ALL WORK SHALL BE DONE BY A LICENSED ELECTRICIAN. WHETHER SHOWN ON PLAN OR NOT, ABANDON ALL WALL ELECTRICAL OUTLETS THROUGH -OUT ENTIRE SPACE. ALL WIRE SHALL BE REMOVED BACK TO SOURCE. ANY BOXES LEFT IN EXISTING BLOCK WALLS MUST BE COVERED WITH PLATE. 10. ALL H.V.A.C. UNITS AND DUCT WORK SHALL BE REMOVED AS SHOWN PER MECHANICAL PLANS 11. ANY AND ALL MEP NOT SHOWN ON PLAN, HOWEVER, LOCATED IN A WALL TO BE DEMOLISHED SHALL BE REMOVED BACK TO THE SOURCE. 12. ANY UNDERGROUND PLUMBING NOT SHOWN / INDICATED SHALL BE ABANDONED AND HARD CAPPED -OFF. 13WREWUNWOMM 0 EXISTING ` CONCRETE EXTERIOR AND . - y A DOWN TO EXISTING FOUNDATIONS REQUIRED, * REMOVE ENTIRE INTERIOR VINYL FLOOR TILE AND VINYL BASE. �. EXISTING EXTERIOR EGRESS DOOR AND FRAME TO BE REMOVED REMOVE EXISTING FABRIC AWNINGS AND SUPPORT STRUCTURES FROM ABOVE ALL WINDOWS AND DOOR AFFECTED BY NEW EXISTING ASPHALT PARKING LOT AND PARKING LOT STRIPING TO REMAIN - • NOT DISTURB. PROTECT THROUGHOUT WORK, CONSTRUCTION AND PATCH/REPAIR ALL AREAS AFFECTED BY NEW SCOPE OF WORK IS LIMITED TO THE REMOVAL OF THE ENTIRE STRUCTURE AT THE NORTHWEST CORNER, PORTIONS OF EXISTING EXTERIOR WALLS FOR NEW STOREFRONT AND DOORS, CONSTRUCTION OF NEW FRAMED TOWER FEATURE, CONSTRUCTION OF INTERIOR PARTITIONS, AND THE INSTALLATION OF ELECTRICAL AND NETWORK CONNECTION FOR NEW TENANT. EXISTING PEARL TENANT TO REMAIN OPEN AND OPERATIONAL THROUGHOUT CONSTRUCTION. GC SHALL MAKE ALL EFFORTS TO ENSURE ACCESSIBLE MEANS OF INGRESS AND EGRESS ARE MAINTAINED AT ALL TIMES. NO WORK TO THE EXISTING SITE, ASPHALT PAVING, SIDEWALKS, DUMPSTERS OR ANY OTHER AMENITIES AS A PART OF THIS PERMIT. NO WORK TO THE EXISTING ROOF STRUCTURE, ROOF SURFACE, ROOF DRAINAGE, CONNECTION TO STORM DRAINAGE OR ANY OTHER ROOF -TOP EQUIPMENT OR AMENITIES EXCEPT AT THOSE AREAS NOTED AS SUCH. SPACE EXISTING RETAIL O REMAIN DO NOT DISTP 13 AS A PART OF THIS PERMIT FIN. FLOOR ELEV. (EXISTING) I I .0 D ,+� �►. it i. - i DEMOLITION PLAN SCALE: 3/16" = V-0" aesi. n .w Inc. p.o. box 14.2116 coral gables, florida 33114.2116 v. 305.443.3100 f. 305.259.3986 e. info @whadesign.com architect of record: William Arthur License Number: 0012074 fVf tv5 Be seal design associate: bFORD These plans and specifications are the exclusive property of WHA Design. Any reproduction, modification, disclosure, and /or use of these materials (or any portion thereof] without WHA Design's prior written consent is strictly prohibited. project information: date: 04/04/14 project number. 13 -20 sheet title: Demolition Plan and Notes sheet number: dl ■ file: d1.0 -demo plan.dwg M 'd. `• J J •E = 0 C/) (U) O W Q ' Q CIO ..E� W 0 X C!) U p N v+ W o ca E O E n 0 C 1..1� .0 U N Q � � CL o project information: date: 04/04/14 project number. 13 -20 sheet title: Demolition Plan and Notes sheet number: dl ■ file: d1.0 -demo plan.dwg