Loading...
14-1268-019NUMBERS 1NDICATE CIRCUIT. NOTE: HASH MARKS INDICATES THE NUMBER OF WIRES EXCLUDING THE REQUIRED EQUIPMENT GROUND. ELECTRICAL SYME30L LEGEND SYMBOL DESCRIPTI ❑N M ❑UNTING i A - 1 X 4 FLUORESCENT FIXTURE SEE FIXTURE Pei LETTER INDICATES TYPE SCHEDULE 2 X 4 FLUORESCENT FIXTURE SEE FIXTURE Q FAN • — AIR HANDLER SHUTDOWN RELAY LETTER INDICATES TYPE SCHEDULE ®SHADING DENOTES FIXTURE WITH EM BATTERY PACK. SEE FIXTURE 48" AFF AS NOTED .. NL' DENOTES FIXTURE UNSWITCHED FOR NIGHT LIGHT SCHEDULE FLUORESCENT STRIP FIXTURE SEE FIXTURE LETTER INDICATES TYPE SCHEDULE FLUORESCENT WALL BRACKET FIXTURE SEE FIXTURE LETTER INDICATES TYPE SCHEDULE PL FLUORESCENT DOWNLiGHT SEE FIXTURE LETTER INDICATES TYPE SCHEDULE EXIT -OR EM EXIT. LETTER SEE FIXTURE INDICATES TYPE. PROVIDE ARROWS AS REQUIRED. SCHEDULE SINGLE POLE SWITCH (20A- 120/211) 48" AFF OR AS S S3 So '3' DENOTES 3 -WAY 'O' DENOTES OCCUPANCY SENSOR NOTED A)__ DUPLEX RECEPTACLE, 125V, 20A 18" AFF OR AS `IG' DENOTES ISOLATED GROUND NOTED +� DUPLEX RECEPTACLE, 125V, 20A 18" AFF OR AS NOTED & DUPLEX RECEPTACLE, 125V, 20A 48" AFF OR AS NOTED QUADRAPLEX RECEPTACLE, 125V, 20A 18" AFF OR AS NOTED V COMBINATION VOICE/DATA OUTLET 18" AFF OR AS NOTED ® T.Y. OUTLET 18" AFF OR AS NOTED ® PANEL50ARD 120/240Y SEE PANEL SCHEDULE /i RACEWAY CONCEALED IN WALL OR ABOVE CEILING SEE SPECIFICATIONS HOMERUN TO PANEL. LETTERS INDICATE PANEL, SEE SPECIFICATIONS NUMBERS 1NDICATE CIRCUIT. NOTE: HASH MARKS INDICATES THE NUMBER OF WIRES EXCLUDING THE REQUIRED EQUIPMENT GROUND. NOTE: ALL MOUNTING HEIGHTS SHOWN ARE TO THE TOP OF THE DEVICE UNLESS NOTED OTHERWISE. NOT ALL SYMBOLS APPEAR ON PLANS, ABBREVIATIONS: AFF - ABOVE FINISHED FLOOR AHU - AIR HANDLING UNIT EFG - BELOW FINISHED GRADE C CONDUIT CW - COOL WHITE DACP - DOOR ALARM CONTROL PANEL DN - DOWN EF - EXHAUST FAN EG - EQUIPMENT GROUND ENCL - ENCLOSURE EWC - ELECTRIC WATER COOLER EWH - ELECTRIC WATER HEATER EX - EXISTING FCU - FAN COiL UNIT FHP - FRACTIONAL HORSE POWER FLA - FULL LOAD AMPERES G - GROUND GFI - GROUND FAULT INTERRUPTER HiD - HiGH INTENS15TY DISCHARGE HORIZ - HORIZONTAL IG - ISOLATED GROUND LW - LIGHT WHITE HP - HORSEPOWER, HEAT PUMP HVAC - HEATING, BENTiLATING, AIR CONDITIONING JB - JUNCTION BOX LRA - LOCKED ROTOR AMPERES MCE - MAiN CiRCUiT BREAKER MLO - MAIN LUGS ONLY N - NEW NL - NIGHT LIGHT OB - OUTLET BOX PB - PULL SOX, PUSH - SUTTON R - RELOCATED RECEPT - RECEPTACLE SF - SUPPLY FAN SPEC - SPECIFICATIONS SWEGS - SMOKE WARNING EMERGENCY CALL SYSTEM TL - TWiSTLOCK TTB - TELEPHONE TERMINAL BOARD TVTB - TELEVISION TERMINAL BOARD UNO - UNLESS NOTED OTHERWISE VERT - VERTICAL WI- 1 - WATT MISER WP - WEATHERPROOF WW - WARM WHITE XFMR - TRANSFORMER System No. C -AJ -1259 F Rating - 3 Hr T Rating - 0 Hr L--.W,— A Section A -A 1. Floor or Wall Assembly - Min 4 -1/2 in, thick reinforced lightweight or normal weight (100 -150 pco concrete. Floor may also be constructed of any min 6 in. thick UL Classified hollow -core Precast Concrete Units *. Wall may also be constructed of any UL Classified Concrete Blocks *. Max diam of opening is 7 in. See Concrete Blocks (CAZT) and Precast Concrete Units (CFTV) categories in the Fire Resistance Directory for names of manufacturers. 2. Through Penetrants - One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the firestop system. The annular space between the pipe, conduit or tubing and the periphery of the opening shall be a min of 0 in. (point contact) to a max of 3 in. Pipe, conduit or tubing to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of metallic pipes, conduit or tubing may be used: A. Steel Pipe - Nom 6 in. diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe - Nom 6 in. diam (or smaller) cast or ductile iron pipe. C. Conduit - Nom 4 in. diam (or smaller) steel electrical metallic tubing or steel conduit. D. Copper Tube - Nom 4 in. diam (or smaller) Type L (or heavier) copper tube. 3. Forming Material - (Optional, Not Shown) - Mineral wool batt packing material or polyurethane backer rod friction fitted into opening and recessed from floor or wall surfaces as required to accommodate required thickness of fill material. 4. Fill, Void or Cavity Material* - Sealant - Min 1/2 in. thickness of fill material applied within the annulus, flush with both surfaces of floor or wall. At the point contact location between penetrating item and concrete, a min 1/4 in. thick bead of fill material shall be applied at the concrete /penetrating item interface on both sides of floor or wall. SPECIFIED TECHNOLOGIES INC - SpecSeal Series SSS Sealant or SpecSeal LCI Sealant *Bearing the UL Classification Mark —® �ecified Technologies Inc. 210 Evans Way Somerville, NJ 08876 ® Reproduced courtesy of Underwriters Laboratories, Inc. @C-AJ-1259 [T� Created or Revised: January 2, 2009 11 800 992 -1180. 908 526-8000 • FAX 908 231 -8415 + E- Mail:techsery stifiresto com • Website :www.sbfiresto com AGE ( ) ( } ( } @ P• P� PAGE 1 OF 1 System No. W -L -1079 F Ratings -1 and 2 Hr (See Item 1B) T Rating - 0 Hr L Rating At Ambient - Less Than 1 CFM /sq ft L Rating At 400 F - Less Than 1 CFM/sq ft A 0 ,'1. VIGIIon IA -,H 1. Wall Assembly - The 1 or 2 hr fire -rated gypsum board /stud wall assembly shall be constructed of the materials and in the manner described in the individual U300 or U400 Series Wall or Partition Design in the UL Fire Resistance Directory and shall include the following construction features: A. Studs - Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC with nom 2 by 4 in. lumber end plates and cross braces. Steel studs to be min 3 -5/8 in. wide and spaced max 24 in. OC. B. Gypsum Board* - 5/8 in. thick, 4 ft wide with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max diam of opening is in wood stud walls is 13 in. Max diam of opening in steel stud walls is 16 in. The hourly F rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. 2. Through Penetrant - One metallic pipe or conduit to be installed either concentrically or eccentrically within the firestop system. The annular space between pipes or conduits and periphery of opening shall be min 0 in. (point contact) to max 3 in. Pipe or conduit to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes or conduits may be used:. A. Steel Pipe - Nam 12 in. diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe - Nom 12 in. diam (or smaller) cast or ductile iron pipe. C. Conduit - Nom 4 in. diam (or smaller) electrical metallic tubing, nom 6 in. diam (or smaller) steel conduit or nom 1 in. diam (or smaller) flexible steel tubing. D. Copper Pipe - Nom 6 in. diam (or smaller) Regular (or heavier) copper pipe. E. Copper Tube - Nam 6 in. diam (or smaller) Type L (or heavier) copper tube. Specified Technologies Inc. 210 Evans Way Somerville, NJ 08876 �. Reproduced courtesy of Underwriters Laboratories, inc. (9) 1 1. Created or Revised: January 2,2009 1 800 992 -1180. 908 526 -8000 • FAX 908 231 -8415 • E- Mail:techsery stifiresto com • Website:www.stifiresto com W -L-10 F t ) ( ) t } @ P• P• PAGE 1 OF 2 Walt Opening Protective Materials (CLIV) SPECIFIED TECHNOLOGIES INC R14288 SUITE 2 200 EVANS WAY, SOMERVILLE, NJ 08876 USA SpecSeal Putty Pads, for use with max 4 -11/16 by 4 -11/16 in. flush device UL Listed metallic outlet boxes installed with steel cover plates in 1 and 2 h fire rated gypsum wallboard wall assemblies framed with mint 3 -1/2 in. deep wood or steel studs and constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the Fire Resistance Directory. Min 3/16 in. thick moldable putty pads are to be installed to completely cover the exterior surfaces of the outlet box (except for the side of the outlet box against the stud) and completely seal against the stud within the stud cavity. An additional 3/16 in. thickness of putty to be formed around the connector securing the end of each electrical metallic tube or conduit to the box. When used with metallic outlet boxes larger than 4 by 4 in., a ball of putty is to be installed to plug the open end of each electrical metallic tube or conduit within the outlet box. When max 4 by 4 in, metallic outlet boxes are used, the ball of putty in the open end of each electrical metallic tube or conduit within the outlet box is optional. When moldable putty pad outlet box protective material is used on boxes on both sides of wall as directed, the horizontal separation between outlet boxes on the opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back -to -back. SpecSeal Putty Pads for use with max 4 by 3 -3/4 by 3 in. deep UL Listed Nonmetallic Outlet Boxes manufactured by Carlon Electrical Products and made from polyvinyl chloride, max 4 by 3 -3/4 by 3 in. deep UL Listed Nonmetallic Outlet Boxes manufactured by Allied Moulded Products Inc. and made from fiber - reinforced thermosetting plastic or max 4 -1/16 by 3 -5/8 by 3 -1/8 in. deep UL Listed Nonmetallic Outlet Boxes manufactured by Thomas & Betts Corp. and made from fiber- reinforced thermosetting plastic. Boxes shall also bear a 2 It rating under the "Outlet Boxes and Fittings Classified for Fire Resistance" category in the Fire Resistance Directory. Boxes installed with steel or plastic cover plates. Putty pads and boxes for use in I and 2 h fire rated gypsum wallboard/wood stud wafl . assemblies constructed of the materials and in the manner specified in the individual U300 Series Wall and Partition Designs in the Fire Resistance Directory. Outlet box secured to wood stud by means of two nailing tabs in conjunction with nails supplied with the outlet box. Min 3/16 in. thick moldable putty pads are to be installed to completely cover the exterior surfaces of the outlet box (except for the side of the outlet box against the stud) including nailing tabs and completely seal against the stud within the stud cavity. An additional 3/16 in. thickness of putty to be formed around the end of each nonmetallic sheathed cable at its connection to the box and to extend a minimum of 1 in. from the box onto the nonmetallic sheathed cable within the stud cavity. When moldable putty pad outlet box protective material is used on boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back -to -back. _1� 1C (-R .. Cn to to LO .. 11 Lo • co O MOTOR RATED SWITCH WITH OVERLOAD RELAYS i - • i A - NON-FUS15LE SAFETY SWITCH-6 ZE AS NOTED Pei FIRE • • i- -• • •, ALARM - • i SUPPLY - �• MOUNTED DUCTWORK Q FAN • — AIR HANDLER SHUTDOWN RELAY i i 4 • • •� s FIRE ALARM MANUAL FULLSTATION 48" AFF AS NOTED .. FIRE ALARM AUDIBLE/VISUAL SIGNAL. ADA COMPAT15LE • i • _ i • •— ON OR AS NOTED FIRE ALARM PANEL . - • i - • A, "Em r w r NOTE: ALL MOUNTING HEIGHTS SHOWN ARE TO THE TOP OF THE DEVICE UNLESS NOTED OTHERWISE. NOT ALL SYMBOLS APPEAR ON PLANS, ABBREVIATIONS: AFF - ABOVE FINISHED FLOOR AHU - AIR HANDLING UNIT EFG - BELOW FINISHED GRADE C CONDUIT CW - COOL WHITE DACP - DOOR ALARM CONTROL PANEL DN - DOWN EF - EXHAUST FAN EG - EQUIPMENT GROUND ENCL - ENCLOSURE EWC - ELECTRIC WATER COOLER EWH - ELECTRIC WATER HEATER EX - EXISTING FCU - FAN COiL UNIT FHP - FRACTIONAL HORSE POWER FLA - FULL LOAD AMPERES G - GROUND GFI - GROUND FAULT INTERRUPTER HiD - HiGH INTENS15TY DISCHARGE HORIZ - HORIZONTAL IG - ISOLATED GROUND LW - LIGHT WHITE HP - HORSEPOWER, HEAT PUMP HVAC - HEATING, BENTiLATING, AIR CONDITIONING JB - JUNCTION BOX LRA - LOCKED ROTOR AMPERES MCE - MAiN CiRCUiT BREAKER MLO - MAIN LUGS ONLY N - NEW NL - NIGHT LIGHT OB - OUTLET BOX PB - PULL SOX, PUSH - SUTTON R - RELOCATED RECEPT - RECEPTACLE SF - SUPPLY FAN SPEC - SPECIFICATIONS SWEGS - SMOKE WARNING EMERGENCY CALL SYSTEM TL - TWiSTLOCK TTB - TELEPHONE TERMINAL BOARD TVTB - TELEVISION TERMINAL BOARD UNO - UNLESS NOTED OTHERWISE VERT - VERTICAL WI- 1 - WATT MISER WP - WEATHERPROOF WW - WARM WHITE XFMR - TRANSFORMER System No. C -AJ -1259 F Rating - 3 Hr T Rating - 0 Hr L--.W,— A Section A -A 1. Floor or Wall Assembly - Min 4 -1/2 in, thick reinforced lightweight or normal weight (100 -150 pco concrete. Floor may also be constructed of any min 6 in. thick UL Classified hollow -core Precast Concrete Units *. Wall may also be constructed of any UL Classified Concrete Blocks *. Max diam of opening is 7 in. See Concrete Blocks (CAZT) and Precast Concrete Units (CFTV) categories in the Fire Resistance Directory for names of manufacturers. 2. Through Penetrants - One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the firestop system. The annular space between the pipe, conduit or tubing and the periphery of the opening shall be a min of 0 in. (point contact) to a max of 3 in. Pipe, conduit or tubing to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of metallic pipes, conduit or tubing may be used: A. Steel Pipe - Nom 6 in. diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe - Nom 6 in. diam (or smaller) cast or ductile iron pipe. C. Conduit - Nom 4 in. diam (or smaller) steel electrical metallic tubing or steel conduit. D. Copper Tube - Nom 4 in. diam (or smaller) Type L (or heavier) copper tube. 3. Forming Material - (Optional, Not Shown) - Mineral wool batt packing material or polyurethane backer rod friction fitted into opening and recessed from floor or wall surfaces as required to accommodate required thickness of fill material. 4. Fill, Void or Cavity Material* - Sealant - Min 1/2 in. thickness of fill material applied within the annulus, flush with both surfaces of floor or wall. At the point contact location between penetrating item and concrete, a min 1/4 in. thick bead of fill material shall be applied at the concrete /penetrating item interface on both sides of floor or wall. SPECIFIED TECHNOLOGIES INC - SpecSeal Series SSS Sealant or SpecSeal LCI Sealant *Bearing the UL Classification Mark —® �ecified Technologies Inc. 210 Evans Way Somerville, NJ 08876 ® Reproduced courtesy of Underwriters Laboratories, Inc. @C-AJ-1259 [T� Created or Revised: January 2, 2009 11 800 992 -1180. 908 526-8000 • FAX 908 231 -8415 + E- Mail:techsery stifiresto com • Website :www.sbfiresto com AGE ( ) ( } ( } @ P• P� PAGE 1 OF 1 System No. W -L -1079 F Ratings -1 and 2 Hr (See Item 1B) T Rating - 0 Hr L Rating At Ambient - Less Than 1 CFM /sq ft L Rating At 400 F - Less Than 1 CFM/sq ft A 0 ,'1. VIGIIon IA -,H 1. Wall Assembly - The 1 or 2 hr fire -rated gypsum board /stud wall assembly shall be constructed of the materials and in the manner described in the individual U300 or U400 Series Wall or Partition Design in the UL Fire Resistance Directory and shall include the following construction features: A. Studs - Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC with nom 2 by 4 in. lumber end plates and cross braces. Steel studs to be min 3 -5/8 in. wide and spaced max 24 in. OC. B. Gypsum Board* - 5/8 in. thick, 4 ft wide with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max diam of opening is in wood stud walls is 13 in. Max diam of opening in steel stud walls is 16 in. The hourly F rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. 2. Through Penetrant - One metallic pipe or conduit to be installed either concentrically or eccentrically within the firestop system. The annular space between pipes or conduits and periphery of opening shall be min 0 in. (point contact) to max 3 in. Pipe or conduit to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes or conduits may be used:. A. Steel Pipe - Nam 12 in. diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe - Nom 12 in. diam (or smaller) cast or ductile iron pipe. C. Conduit - Nom 4 in. diam (or smaller) electrical metallic tubing, nom 6 in. diam (or smaller) steel conduit or nom 1 in. diam (or smaller) flexible steel tubing. D. Copper Pipe - Nom 6 in. diam (or smaller) Regular (or heavier) copper pipe. E. Copper Tube - Nam 6 in. diam (or smaller) Type L (or heavier) copper tube. Specified Technologies Inc. 210 Evans Way Somerville, NJ 08876 �. Reproduced courtesy of Underwriters Laboratories, inc. (9) 1 1. Created or Revised: January 2,2009 1 800 992 -1180. 908 526 -8000 • FAX 908 231 -8415 • E- Mail:techsery stifiresto com • Website:www.stifiresto com W -L-10 F t ) ( ) t } @ P• P• PAGE 1 OF 2 Walt Opening Protective Materials (CLIV) SPECIFIED TECHNOLOGIES INC R14288 SUITE 2 200 EVANS WAY, SOMERVILLE, NJ 08876 USA SpecSeal Putty Pads, for use with max 4 -11/16 by 4 -11/16 in. flush device UL Listed metallic outlet boxes installed with steel cover plates in 1 and 2 h fire rated gypsum wallboard wall assemblies framed with mint 3 -1/2 in. deep wood or steel studs and constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the Fire Resistance Directory. Min 3/16 in. thick moldable putty pads are to be installed to completely cover the exterior surfaces of the outlet box (except for the side of the outlet box against the stud) and completely seal against the stud within the stud cavity. An additional 3/16 in. thickness of putty to be formed around the connector securing the end of each electrical metallic tube or conduit to the box. When used with metallic outlet boxes larger than 4 by 4 in., a ball of putty is to be installed to plug the open end of each electrical metallic tube or conduit within the outlet box. When max 4 by 4 in, metallic outlet boxes are used, the ball of putty in the open end of each electrical metallic tube or conduit within the outlet box is optional. When moldable putty pad outlet box protective material is used on boxes on both sides of wall as directed, the horizontal separation between outlet boxes on the opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back -to -back. SpecSeal Putty Pads for use with max 4 by 3 -3/4 by 3 in. deep UL Listed Nonmetallic Outlet Boxes manufactured by Carlon Electrical Products and made from polyvinyl chloride, max 4 by 3 -3/4 by 3 in. deep UL Listed Nonmetallic Outlet Boxes manufactured by Allied Moulded Products Inc. and made from fiber - reinforced thermosetting plastic or max 4 -1/16 by 3 -5/8 by 3 -1/8 in. deep UL Listed Nonmetallic Outlet Boxes manufactured by Thomas & Betts Corp. and made from fiber- reinforced thermosetting plastic. Boxes shall also bear a 2 It rating under the "Outlet Boxes and Fittings Classified for Fire Resistance" category in the Fire Resistance Directory. Boxes installed with steel or plastic cover plates. Putty pads and boxes for use in I and 2 h fire rated gypsum wallboard/wood stud wafl . assemblies constructed of the materials and in the manner specified in the individual U300 Series Wall and Partition Designs in the Fire Resistance Directory. Outlet box secured to wood stud by means of two nailing tabs in conjunction with nails supplied with the outlet box. Min 3/16 in. thick moldable putty pads are to be installed to completely cover the exterior surfaces of the outlet box (except for the side of the outlet box against the stud) including nailing tabs and completely seal against the stud within the stud cavity. An additional 3/16 in. thickness of putty to be formed around the end of each nonmetallic sheathed cable at its connection to the box and to extend a minimum of 1 in. from the box onto the nonmetallic sheathed cable within the stud cavity. When moldable putty pad outlet box protective material is used on boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back -to -back. _1� 1C (-R .. Cn to to LO .. 11 Lo • co O Sheet E 1 i • Pei • s .. i CO • Sheet E 1