Loading...
10-528-010HEAT PUMP EQUIPMENT SCHEDULE DESIGNATION HVAC #1 SUPPLY CFM/ 0/A CFM 1200/0 TOTAL COOLING CAPACITY, BTU /HR. 33,400 SENSIBLE COOLING CAPACITY, BTU/HR. 24,350 HEATING CAPACITY BTU /H 34,400 HSPF 8.5 AIR TEMP. CONDENSER 95' AIR TEMP. ENT. EVAP., DB /WB 80/67 COND. M.C.A. 30130 COND. MAX. FUSE 35/35 EVAP. MOTOR FLA. 1,7 VOLTAGE, PHASE, CY 208/230/ -1 /60 CONDENSING UNIT MODEL 13PJL036 A.H.U. MODEL RHLL- HM3617 MANUFACTURER RHEEM UNIT TYPE SPLIT, DX SEER OR EER 14.0 REFRIGERANT TYPE R -410A REFRIGERANT LINES (LIQUID, SUCT) 3" 3" AHU WEIGHT (LBS.) 105 AHU DIMENSIONS (HxWxD) inches 43/17/21 COND. UNIT WEIGHT (LBS.) 215 COND. UNIT DIMENSIONS (HxWxD) inches 27 -8 "X 31- $X31 -e' PROVIDE (4) 4" ANCHOR BOLTS OF 500 LBS MIN. PULL OUT CAPACITY ON THE BASE OF THE PAN TO PENETRATE CONCRETE 142" MIN AS PER MANUFACTURER RECOMMENDATION TO WITHSTAND 150 MPH WINDS. 4" CONCRETE SLAB .a. a .a n �4 NEOPRENE PAD (TYPICAL) CONCRETE PAD CONDENSER UNIT MOUNTING DETAIL. nts a d HVAC GENERAL NOTES 1. THE WORK TO BE DONE UNDER THIS HEADING INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS, EQUIPMENT, PERMITS, FEES, INSPECTIONS, TESTS, INSURANCE, ETC. REQUIRED FOR THE COMPLETION OF THE HVAC SYSTEM SHOWN ON DRAWINGS AND /OR LISTED BELOW. 2. THE CONTRACTOR SHALL, BEFORE SUBMITTING ANY PROPOSAL, EXAMINE THE PROPOSED SITE AND SHALL DETERMINE FOR HIMSELF THE CONDITIONS THAT MAY AFFECT THE WORK. NO ALLOWANCE SHALL BE MADE IF THE CONTRACTOR FAILS TO MAKE SUCH EXAMINATION. 3. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE FLORIDA BUILDING CODE AND ALL LOCAL CODES. 4. CONTRACTOR SHALL VERIFY SPACE CONDITIONS AND DIMENSIONS AND SHALL COORDINATE WORK WITH ALL OTHER TRADES AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF DUCTWORK AND EQUIPMENT. 5. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH PROGRESS OF CONSTRUCTION AND IN STRICT COMPLIANCE WITH ALL APPLICABLE CODES AND STANDARDS. 6. NEW DUCTWORK TO BE R -6. ALL DUCT SIZES SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. 7. VERIFY ALL VOLTAGES WITH ELECTRICAL CONTRACTOR BEFORE ORDERING ANY EQUIPMENT. 8. ALL EQUIPMENT AND MATERIALS SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR. COMPRESSOR SHALL CARRY 10 YEAR FACTORY GUARANTEE. 9. VIBRATION ISOLATION: ALL EQUIPMENT AS PER MANUFACTURER'S RECOMMENDATIONS OR AS SCHEDULED ON DRAWINGS. 10. ALL OUTSIDE EQUIPMENT SHALL BE SECURED TO WITHSTAND 150 M.P.H. WINDS. 11. DO NOT SCALE THIS DRAWING FOR EXACT DIMENSIONS AT THE JOB SITE. THE MECHANICAL PLANS ARE INTENDED TO BE DIAGRAMMATIC AND ARE BASED ON ONE MANUFACTURER EQUIPMENT. THEY ARE NOT INTENDED TO SHOW EVERY ITEM IN ITS EXACT LOCATION, THE EXACT DIMENSIONS, OR ALL THE DETAILS OF THE EQUIPMENT. THE CONTRACTOR SHALL VERIFY THE ACTUAL DIMENSION OF THE EQUIPMENT PROPOSED TO ENSURE THAT THE EQUIPMENT WILL BE FIT IN THE AVAILABLE SPACE. 12. THERMOSTAT SHALL BE LOW VOLTAGE COOL WITH FAN AND SELECTOR SWITCHES ON SUB BASE. MOUNT ON WALL WHERE SHOWN ON PLANS 5' -0" ABOVE FINISHED FLOOR OR PER HANDICAP CODE REQUIREMENT. 13. PROVIDE TURNING VANES AT ALL ELBOWS = OR > 45'. GALV. ROOF CAP FLASHING 2 "X4" blk'g -4" FLEXIBLE METAL TO EXHAUST FAN BATH EXHAUST ROOF CAP DETAIL n. t. s. CORROSION RESISTANT SCREEN WITH OPENINGS >1/4" AN5 1/2" AND BACK DRAFT DAMPER. EXHAUST FAN SCHEDULE E.F. 50 BRAND NUTONE MOD: 696 N RPM: 1600 AMPS : 0.76 ELEC. CHARACT. 115//60 CFM: 50 OOF WOOD BEAM #12 GE. HANGER WIRE SHEET METAL SCREW 142' GE. 26 STRAP HANGER AT 5' MAX. SEE PROJECT FOR SIZE FLEXIBLE DUCT HANGERS (TYPICAL) LIQUID LINE SECURE W /PLASTIC STRAP TO INSULATION . STRAP HANGER BUILDING STRUCTURE SUCTION LINE Y" ARMAFLEX REFRIGERANT PIPE HANGER DETAIL PROVIDE A FLOW SWITCH T=INSTALLED ON THE SAFETY OVERFLOW EQUIPMENT SUPPLIED DRAI ATTIC THREAD - CUTTING SCREW (TYPE F) #10 -32NF @4" OC. . FACTORY INSTALLED CIRCUIT BREAKER. -$" OD LIQUID PIPE THROUGH ATTIC TO SOUTH WALL AND TO C /U. -4" OD SUCTION PIPE THROUGF ATTIC TO SOUTH WALL AND TO C /U. INSULATED. -4" PVC DRAIN PIPE 23 "W x 22 "H x 23 "1 -g' OD DRAIN PIPE ALUMINUM STAND THROUGH ATTIC TO SOIL SECURE TO FLOOR AREA AT 12" AWAY SLAB THRU ANCHOR FROM STRUCTURE. INSULATED. BOLTS. '. DRAIN PUMP LITTLE GIANT MODEL VCMA- 15ULS, 115 V, 65 GALS X H @ 1 ", so HP OR EQUAL. AIR HANDLER INSTALLATION DETAIL n.t.s. PLENUM SEALED CEILING PENETRATION REMOVABLE PERFORATED CAP ^'4 OD DRAIN VENT. I /-NEOPRENE PADS HVAC DESIGN REQUIREMENTS YES NO DUCT SMOKE DETECTOR ,i FIRE DAMPER(S) SMOKE DAMPERS FIRE RATED ENCLOSURE i% F.RATED R CEILING ASSEMBLY vl- FIRE STOPPING v" SMOKE CONTROL vl*l -4" SHEET METAL DUCT GE. 26. WALL CAP WITH BACKDRAFT DAMPER. (WITHOUT DRYER SCREEN). DRYER EXHAUST DETAIL SIDEWALL DISCHARGE n.t.s. 1 -2" WIDTH SEE PRO FOR SIZE CONDENSER UN ANCHORED TO SLAB. SEE DETAIL. 11111111111111111111 TANKLESS W/H UTILITY /LAUNDRY u ROOM TO BE o LEGALIZE DRYER AND WASHE COMBO /-6 "X6" WALL CAP Pte_ "-4" SHEET METAL DUCT GA. 26. ------------- I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I EXISTING I I CARPORT I I STRUCTURE I I TO REMAIN I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I _____ - - - -- --- __===== a=--- =__ - - - - -- PROPOSED MECHANICAL PLAN SCALE: 1/4"=I'-O" R V'S'11D J I—)e No. /DATE: No. /DATE: THESE DRAWING & SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF TERRACOTA BUILDING SERVICES, WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED OR NOT, THEY ARE NOT TO BE USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH THE APPROPRIATE COMPENSATION TO TERRACOTA BUILDING SERVICES IS PROHIBITED. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITE CONDITION PRIOR TO PROCEEDING WITH WORK. • ,�- „•.sae,, F 4D� ;� �►31 t;Nn � aL l 0 fi n U N 0000 N N ” 0 ��� V OU W M O 5 � A @) �N� w a z Q p4 aA N N Z w O O °° C7 r`.~J1 �! �_ 0/ O� O � O � 0 Ob O Cfl z Ln d- N L'j �> w QQ Q CJ W� z O 00 CD Cl) Ln ° m O CD w O � Q Q o Cfl W JOB No.: 515 DRAWN BY: T.B.S. SCALE: AS SHOW DATE: 06 -07 -2010 SHEET NAME: MECHANICAL M -1 SHEET 10 OF 10 J im ,p b on Sim .sue ' ;.*