10-528-009TYP. PLUMBING FIXTURES PIPING CONNECTIONS
QUANT
FIXTURE
C.W.
H.W.
WASTE
F.UNITS
F.UNITS
TOTAL
1
TUB
1/2
1/2
2"
2
2
0
SHOWER
1/2"
1/2"
2"
2
0
1
TOILET
1/2 "
3"
4
4
1
LAVATORY
1/2"
1/2"
2"
1
1
1
KITCHEN SINK
1/2"
1/2"
2"
2
2
1
C. WASHER
1/2"
1/2"
2"
4
4
TOTAL
13
O1
3/4"
COLD WATER
2O1/2"
COLD WATER
30
1/2"
COLD & HOT WATER
4O1/2"
HOT WATER
O1/2"
No. /DATE:
HOT WATER & 3/4" COLD WATER
O1"
COLD WATER
NOT
ALL SANITARY PIPE 2"0 OR SMALLER
SHALL RUN @ 1/4" SLOPE PER L.FT.
3" AND LARGER @ 1/8" SLOPE PER L.FT.
PLUMBING NOTES
1. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST
EDITION OF THE "SOUTH FLORIDA BUILDING CODE," CHAPTER 46, LOCAL
ORDINANCES AND IN COMPLIANCE WITH THE "FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION."
2. CONTRACTOR TO VERIFY AT SITE LOCATION, ELEVATION AND SIZE OF ALL
EXISTING MAINS, WATER AND SEWER FOR CONNECTION OF NEW SERVICES BEFORE
INSTALLATION OF ANY PIPING.
3. UNDERGROUND METAL PIPING SHALL BE PROTECTED WITH A COAT OF BITUMINOUS
COMPOUND BEFORE COVERING, "BITUMASTIC" OR EQUAL.
4. PROVIDE SHUT ?OFF AND VACUUM BREAKER TO ALL HOSE BIBS AND FAUCETS WITH
HOSE ?END CONNECTIONS.
5. ALL FIXTURES SHALL BE PROTECTED AGAINST WATER HAMMER WITH AIR CHAMBERS
OR SHOCK ABSORBERS AS INDICATED ON PLANS.
6. ALL FLOOR DRAINS TO HAVE TRAP PRIMERS TO PROTECT THE SEAL OF THE TRAP.
7. PROVIDE CONTROL VALVES TO: ALL MAINS ENTERING THE BUILDING, RISERS,
BRANCHES, GROUP OF FIXTURES, AND TO EACH PIECE OF EQUIPMENT.
8. PLUMBING FIXTURES SHALL BE "AMERICAN STANDARD" OR APPROVED EQUAL.
ALL FIXTURE TRIM SHALL BE CHROME PLATED. FIXTURES SHALL BE PROVIDED
WITH SUPPORTS, HANGERS, ETC.
9. WASTE LINES TO SLOPE 1 /8 " /FT. UNLESS OTHERWISE NOTED.
10. PROVIDE FULLY ACCESSIBLE CLEAN OUTS ON SANITARY AND ANY WASTE PIPING,
AT EVERY CHANGE OF DIRECTION, AND AT BOTTOM OF STACKS. CLEAN OUT
LOCATION AND SIZES ON HORIZONTAL LINES SHALL BE ACCORDING TO CODE.
11. VENT LINES TO EXTEND 6" MIN. ABOVE ROOF AND FLASH W /LEAD OR CONNECT
TO EXISTING VENT SYSTEM.
ROUGH IN TO 6" ABOVE
PROPOSED FINISH GRADE
& CAP
FINISHED GRADE
/
\�\
/i A
CUT BACK TO FINISHED
GRADE & PROVIDE 3"
THREADED BRASS CAP
��\
EXTERIOR 2 -WAY CLEAN -OUT DETAIL
N.T.S.
Ths oBw Man - =4
Water Beater
t,.
r
TI TAN —SCR4
TRIPLE ELEMENT
ELECTRONIC TANKLESS WATER HEF
AUTOMATIC TEMPERATURE CONTRO
NOTE: THESE MODELS NEED TWO I
DOUBLE POLE 40 AMPS BREAKER.
DIMENSIONS: 12 X 11 X 3
WEIGHT: 10 POUNDS
WATER CASING: BRASS
PIPE FITTING: 1/2" STANDARE
PRESSURE REOUIEREMENTS: 5
ELEMENTS: INCOLOY / NICHROME
ACTIVATION: 0.4 GPM —ON /
WARRANTY: 10 YEARS ON WATER
CAPACITY: ONE GALLON
EFFICIENCY: 0.95
3"0 PVC DRAIN LII
AT 1/8" SLOPED M
UNDERGROUND
CONNECTED
EXISTING MAIN SE'
LII
3 "0 PVC DRAIN LII
AT 1/8" SLOPED M
UNDERGROUND
CONNECTED
EXISTING MAIN SEI
LII
c
EX
EXIST. WATER
METER
REPLACE EXISTING 3/4"
MAIN WATER LINE FOR 1'O
FROM WATER METER TO
HOUSE TIE —IN
3/4" UNDERGROUN
COLD WATER LINE TO
UTILITY ROOM FROM 1"
MAIN LINE
WATER LINE UTILITY /LAUNDRY
ROOM TIE —IN W/ 3/4" MAIN
VALVE
■ VAA I vlmmv
.—
3"
/-VTR
3"0 PVC DRAIN
LINE AT 1 /8"
SLOPED MIN.
UNDERGROUND
�JIII�
f
R :E V I S=1=�N J --e
No./pATE: -,
No. /DATE:
THESE DRAWING & SPECIFICATIONS
ARE INSTRUMENTS OF SERVICE AND
SHALL REMAIN THE PROPERTY OF
TERRACOTA BUILDING SERVICES,
WHETHER THE PROJECT FOR WHICH
THEY WERE PREPARED IS EXECUTED
OR NOT, THEY ARE NOT TO BE
USED IN ANY MANNER ON OTHER
PROJECTS OR EXTENSIONS TO THIS
PROJECT EXCEPT BY AGREEMENT IN
WRITING AND WITH THE APPROPRIATE
COMPENSATION TO TERRACOTA
BUILDING SERVICES IS PROHIBITED.
CONTRACTOR IS RESPONSIBLE FOR
VERIFYING ALL SITE CONDITION PRIOR
TO PROCEEDING WITH WORK.
• t����t
11'J°
W
N �
O
�
O
vl
0
0
.-.
C7 °
A
c
�N
d w
Q
0 �
N 00
0
00
M
O
V
U ONk
O
cn
C) cn
�7 O �
O
�
A � � Pte-,
W
00
O
Q0
I
CD
th
z
W
� �
Q W _0
>
VQ
W
�
QQ Q
00
Lry�I
z (Y Cfl
o m Ln Q 00
v J
< Q 3: r
_
o� o — z
z
CD
w
o Q
� c_6
W
JOB No.: 515
DRAWN BY: T.B.S.
SCALE: AS SHOW
DATE: 06 -07 -2010
SHEET NAME:
PLUMBING
P =1
SHEET
9 OF
10
t�
1