Loading...
10-528-009TYP. PLUMBING FIXTURES PIPING CONNECTIONS QUANT FIXTURE C.W. H.W. WASTE F.UNITS F.UNITS TOTAL 1 TUB 1/2 1/2 2" 2 2 0 SHOWER 1/2" 1/2" 2" 2 0 1 TOILET 1/2 " 3" 4 4 1 LAVATORY 1/2" 1/2" 2" 1 1 1 KITCHEN SINK 1/2" 1/2" 2" 2 2 1 C. WASHER 1/2" 1/2" 2" 4 4 TOTAL 13 O1 3/4" COLD WATER 2O1/2" COLD WATER 30 1/2" COLD & HOT WATER 4O1/2" HOT WATER O1/2" No. /DATE: HOT WATER & 3/4" COLD WATER O1" COLD WATER NOT ALL SANITARY PIPE 2"0 OR SMALLER SHALL RUN @ 1/4" SLOPE PER L.FT. 3" AND LARGER @ 1/8" SLOPE PER L.FT. PLUMBING NOTES 1. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE "SOUTH FLORIDA BUILDING CODE," CHAPTER 46, LOCAL ORDINANCES AND IN COMPLIANCE WITH THE "FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION." 2. CONTRACTOR TO VERIFY AT SITE LOCATION, ELEVATION AND SIZE OF ALL EXISTING MAINS, WATER AND SEWER FOR CONNECTION OF NEW SERVICES BEFORE INSTALLATION OF ANY PIPING. 3. UNDERGROUND METAL PIPING SHALL BE PROTECTED WITH A COAT OF BITUMINOUS COMPOUND BEFORE COVERING, "BITUMASTIC" OR EQUAL. 4. PROVIDE SHUT ?OFF AND VACUUM BREAKER TO ALL HOSE BIBS AND FAUCETS WITH HOSE ?END CONNECTIONS. 5. ALL FIXTURES SHALL BE PROTECTED AGAINST WATER HAMMER WITH AIR CHAMBERS OR SHOCK ABSORBERS AS INDICATED ON PLANS. 6. ALL FLOOR DRAINS TO HAVE TRAP PRIMERS TO PROTECT THE SEAL OF THE TRAP. 7. PROVIDE CONTROL VALVES TO: ALL MAINS ENTERING THE BUILDING, RISERS, BRANCHES, GROUP OF FIXTURES, AND TO EACH PIECE OF EQUIPMENT. 8. PLUMBING FIXTURES SHALL BE "AMERICAN STANDARD" OR APPROVED EQUAL. ALL FIXTURE TRIM SHALL BE CHROME PLATED. FIXTURES SHALL BE PROVIDED WITH SUPPORTS, HANGERS, ETC. 9. WASTE LINES TO SLOPE 1 /8 " /FT. UNLESS OTHERWISE NOTED. 10. PROVIDE FULLY ACCESSIBLE CLEAN OUTS ON SANITARY AND ANY WASTE PIPING, AT EVERY CHANGE OF DIRECTION, AND AT BOTTOM OF STACKS. CLEAN OUT LOCATION AND SIZES ON HORIZONTAL LINES SHALL BE ACCORDING TO CODE. 11. VENT LINES TO EXTEND 6" MIN. ABOVE ROOF AND FLASH W /LEAD OR CONNECT TO EXISTING VENT SYSTEM. ROUGH IN TO 6" ABOVE PROPOSED FINISH GRADE & CAP FINISHED GRADE / \�\ /i A CUT BACK TO FINISHED GRADE & PROVIDE 3" THREADED BRASS CAP ��\ EXTERIOR 2 -WAY CLEAN -OUT DETAIL N.T.S. Ths oBw Man - =4 Water Beater t,. r TI TAN —SCR4 TRIPLE ELEMENT ELECTRONIC TANKLESS WATER HEF AUTOMATIC TEMPERATURE CONTRO NOTE: THESE MODELS NEED TWO I DOUBLE POLE 40 AMPS BREAKER. DIMENSIONS: 12 X 11 X 3 WEIGHT: 10 POUNDS WATER CASING: BRASS PIPE FITTING: 1/2" STANDARE PRESSURE REOUIEREMENTS: 5 ELEMENTS: INCOLOY / NICHROME ACTIVATION: 0.4 GPM —ON / WARRANTY: 10 YEARS ON WATER CAPACITY: ONE GALLON EFFICIENCY: 0.95 3"0 PVC DRAIN LII AT 1/8" SLOPED M UNDERGROUND CONNECTED EXISTING MAIN SE' LII 3 "0 PVC DRAIN LII AT 1/8" SLOPED M UNDERGROUND CONNECTED EXISTING MAIN SEI LII c EX EXIST. WATER METER REPLACE EXISTING 3/4" MAIN WATER LINE FOR 1'O FROM WATER METER TO HOUSE TIE —IN 3/4" UNDERGROUN COLD WATER LINE TO UTILITY ROOM FROM 1" MAIN LINE WATER LINE UTILITY /LAUNDRY ROOM TIE —IN W/ 3/4" MAIN VALVE ■ VAA I vlmmv .— 3" /-VTR 3"0 PVC DRAIN LINE AT 1 /8" SLOPED MIN. UNDERGROUND �JIII� f R :E V I S=1=�N J --e No./pATE: -, No. /DATE: THESE DRAWING & SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF TERRACOTA BUILDING SERVICES, WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED OR NOT, THEY ARE NOT TO BE USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH THE APPROPRIATE COMPENSATION TO TERRACOTA BUILDING SERVICES IS PROHIBITED. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITE CONDITION PRIOR TO PROCEEDING WITH WORK. • t����t 11'J° W N � O � O vl 0 0 .-. C7 ° A c �N d w Q 0 � N 00 0 00 M O V U ONk O cn C) cn �7 O � O � A � � Pte-, W 00 O Q0 I CD th z W � � Q W _0 > VQ W � QQ Q 00 Lry�I z (Y Cfl o m Ln Q 00 v J < Q 3: r _ o� o — z z CD w o Q � c_6 W JOB No.: 515 DRAWN BY: T.B.S. SCALE: AS SHOW DATE: 06 -07 -2010 SHEET NAME: PLUMBING P =1 SHEET 9 OF 10 t� 1