10-528-008200 AMP PANEL 'A" SCHEDULE SINGLE PHASE 240 -120V
CIRC.
BKR
WIRE
VOLT
DESCRIP.
LOAD
CIRC.
BKR
WIRE
VOLT
DESCRIP.
LOAD
1
3
60
6
240
RANGE
12000
2
4
60
6
240
A/C
10000
5
7
60
6
240
A/C COMP.
6
40
8
240
TANCKLESS W/H
9000
9
20
12
115
BATH (GFI)
1500
10
20
12
115
REFRI.
850
11
20
12
115
S. APP
1500
12
20
12
115
OUTLET & LIGHT
13
20
12
115
S. APP
1500
14
20
12
115
OUTLET & LIGHT
-SQ /F OF COND. SPACE E
15
20
12
115
OUTLET & LIGHT
*
16
20
12
115
OUTLET & LIGHT
17
20
12
115
S. APP
1500
18
20
12
115
DISHWASHER
1500
19
20
12
115
OUTLET & LIGHT
*
20
20
12
115
OUTLET & LIGHT
21
20
12
115
OUTLET & LIGHT
*
22
24
80
4
240
MAIN BRAKE FOR
PANEL "B"
SEE
PANEL "B"
LOAD
23
-2 TANKLESS W/H ( ELECT.) ........... ..........................18000 V
VA 1
10' -0" FROM METER U
25
A THROUGH #10
-1 REFRIGERATOR .......................... ............................850 V
26
L_4THHN
P
PANEL B IN UTILITY ROOM. 1
19A
27
VA r
28
=III �' I
29
NEW LOCATION
-1 DISHWASHER =
1500 V
VA -
30
I. I I -11= I
III= III = III =11 III -III= III = III -III �
F
FOR ELECTRICAL
31
III .I -111 =III I
- -
32
33
SPACE
SPACE
PANEL "B" SCHEDULE
CIRC.
BKR
WIRE
VOLT
DESCRIP.
LOAD
1
2
30
10
240
STACKABLE
WASHER /DRYER
5000
3
15
14
115
OUTLET & LIGHT
4
5
40
8
240
TANCKLESS W/H
9000
6
-TOTAL SQ /F OF LIGHT SPACE /
1722 S
/ S
SERVICE. 8
7
80 AMP BKR IN NEW MAI
-AT 3 WATTS /SF ..................... ............................... 5
5166 S
SQ /F H
8
SPACE
SMOKE AND CARBON MONOXIDE DETECTORS NOTE.
PROVIDE SMOKE DETECTOR INSIDE & OUTSIDE OF ALL
SLEEPING AREAS AS SHOWN IN THE ELECTRICAL PLAN. A
CARBON MONOXIDE SHALL BE INSTALLED. ALL DEVICES WILL
BE INTER CONNECTED
SMOKE DETECTOR SHALL NOT BE PLACED WITHIN 3 FT. OF
ANY A/C GRILL, BATHROOM, KITCHEN DOORS
SMOKE DETECTOR SHALL BE HARDWIRED ( 110 VOLT TYPE)
TO A NON- SIITCHABLE BEDROOM CIRCUIT NTH
BATTERY BACK -UP AND SHALL NOT BE CONNECTED ONTO
THE LOAD SIZE OF GROUND FAULT CIRCUIT INTERRUPTER
ALL SMOKE DETECTORS WITHIN EACH UNIT SHALL BE
INTERCONNECTED.
ELECTRICAL LOAD CALCULATION
ELECTRICAL SPECIFICATIONS.
1. THE ELECTRICAL INSTALLATION SHALL CONFORM TO THE REQUIREMENTS OF NEC.
&CLEARANCE NEC 110 -16 (2)
&DEDICATED SPACES FOR SWITCHBOARDS AND PANEL BOARDS INCLUDING.
2. THE ELECTRICAL CONTRACTOR SHALL PROVIDE GROUNDING WHICH COMPLIES
WITH THE CODE AND INSPECTION AUTHORITY.
3. THE E.C. SHALL INSTALL ELECTRICAL DEVICES AND EQUIPMENT TO WITHSTAND THE
SHORT CIRCUIT CURRENT AVAILABLE THE CURRENT PROTECTIVE DEVICE RATING FOR
EQUIPMENT SHALL BE VERIFIED PRIOR TO BID.
4. ALL CIRCUITS TO BE NUMBERED AND IDENTIFIED ON ELECTRICAL PANEL
5. RECEPTACLES AND SWITCH PLATES TYPE & COLOR SHALL BE SELECTED BY OWNER
6. ALL BREAKERS TO BE SIZED ACCORDING TO MAN UFACTURER'SSPECIFICATIONS.
7. ELECTRICAL CONTRACTOR PRIOR TO INSTALLATION OF ROUGH ELECTRICAL WIRING
CHECK NAMEPLATE DATA OF ALL EQUIPMENT . APPLIANCES TO OBTAIN CORRECT
SIZES AND OVER CURRENT PROTECTION.
8. VERIFY MANUFACTURER'S SPECIFICATIONS AS TO THE EXACT LOCATION OF
RECEPTACLES /JUNCTION BOX FOR APPLIANCES AND OTHER EQUIPMENT.
9 -THE CONTRACTOR SHALL FURNISH LABOR, MATERIAL AND EQUIPMENT FOR A
COMPLETE ELECTRICAL :INSTALLATION IN ACCORDANCE WITH THESE DRAWING AND SPECIFICATIONS.
10 -THE CONTRACTOR SHALL FURNISH ALL MATERIAL & WORKMANSHIP FREE OF DEFECTS FOR A PERIOD
OF NOT LESS THAN ONE YEAR FROM THE DATE OF ACCEPTANCE. THE GUARANTEE SHALL BE WRITING
11-THE CONTRACTOR SHALL OBTAIN ALL NECESSARY BUILDING PERMIT, LICENSES AND INSURANCE FOR
WORK UNDER THIS CONTRACT.
12 -THE CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITION.
13- COMPLY WITH THE NATIONAL ELECTRICAL CODE (N.E.C.) AND THE FLORIDA BUILDING CODE
(F.B.C.)OR ANY OTHER LOCAL CODE OR REGULATION IN ITS CURRENT EDITION.
14- PROVIDE TEMPORARY POWER AND LIGHT OUTLETS FOR USE BY OTHER TRADES.
15- PROVIDE EMPTY CONDUITS AS REQUIRED FOR TELEPHONE LINES INCLUDING WIRING'
16 -ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE
PROGRESS OF CONSTRUCTION.
17- COORDINATE ALL OUTLETS LOCATION WITH BUILDING ARCHITECTURAL FEATURES.
18 -ALL MOUNTING HARDWARE SHALL BE BY CONTRACTOR.
a
4'- 10"
rj3d 4,5B
UTILITY /LAUNDRY
36 ROOM TO BE ° o
LEGALI ZE 1 2
' '3B
°
-6" 3'-1" ' -3"
L— — — — — — — —
14' -10"
3 #4 IN & 1# 10 GROUND IN
PVC SCHED. 80 COD. �1
1/4" P.V.C. GO OUT FROM
80 AMP BKR IN NEW MAIN
HOUSE PANEL A THROUGH
UNDERGROUND TO NEW
PANEL B IN UTILITY ROOM.
N
_1 1
W/P EXTERIOR 80
AMP. ELECTRICAL
PANEL W/ 80 AMP
DISC.
(PANEL "A" & PANEL "B" )
GEN. LIGHTING ( *) T
PROVIDE 3# 2/0 3
3 #4 IN & 1# 10 GROUND IN
W/ OVERHEAD 1
1/4" P.V.C. GO OUT FROM
-TOTAL SQ /F OF LIGHT SPACE /
1722 S
/ S
SERVICE. 8
80 AMP BKR IN NEW MAI
-AT 3 WATTS /SF ..................... ............................... 5
5166 S
SQ /F H
HOUSE PANEL A THROUGH
3# 2/0 U
UNDERGROUND TO NEW
IN 2" COD. N
NEW 200 AMP P
PANEL B IN UTILITY ROOM.
NEW W/P B
BKR PANEL.
-SQ /F OF COND. SPACE E
ELECTRICAL E
EXTERIOR. W/P NEW 80
-AT 3 WATTS /SF ........................... ...........................5166 V
VA M
METER W/ 200 A
AMP PANEL
NEW L
IN PVC SCHED. 80 COD. W/ 8
LOCATION FOR
-AT 1500 WATTS /CKT ................... ...........................4500 V
VA I
�1 1/4" P.V.C. GO OUT DISC.WATER E
ELECTRICAL METER
- RANGER ........ ............................... ..........................12000 V
VA F
FROM 80 AMP BKR IN PROOF.
-DRYER / WASHER ............................ ...........................5000 V
VA N
3/4" METAL C.W. PIPE A
NEW MAIN HOUSE PANEL IN UTILITY
-2 TANKLESS W/H ( ELECT.) ........... ..........................18000 V
VA 1
10' -0" FROM METER U
A THROUGH #10
-1 REFRIGERATOR .......................... ............................850 V
VA L
L_4THHN
P
PANEL B IN UTILITY ROOM. 1
19A
-1 BATH GFI AT 1500 .................. ...........................1500 V
VA r
-
=III �' I
��III���II ���III���II N
NEW LOCATION
-1 DISHWASHER =
1500 V
VA -
= ��� =ui =ul =III= III =
I. I I -11= I
III= III = III =11 III -III= III = III -III �
F
FOR ELECTRICAL
III .I -111 =III I
- -
ELECTRICAL LEGEND I
SINGLE POLE SWITCH
DWELLING UNIT BEDROOM NOTE: (UP18X RF.F.) CLE
ALL BRANCH CIRCUITS THAT SUPPLY 125 —VOLT, SINGLE C�= GFI OUTLET
PHASE, 15 AND 20— AMPERE OUTLET INSTALLED IN DWELLING GFI
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC —FAULT
CIRCUIT INTERRUPTER LISTED TO PROVIDE PROTECTION TOF I-O INCANDESCENT LIGHT.
THE ENTIRE BRANCH CIRCUIT. WALL BRACKET TYPE
INDICATED ON PLANS
TAMPER - RESISTANT RECEPTACLES NOTE:
IN ALL AREAS SPECIFIED IN 210.52, ALL 125 VOLT, 15 AND
20 AMPERE RECEPTACLES SHALL BE LISTED
TAMPER — RESISTANT RECEPTACLES.
LV'EX -LC101 6" APERTURE
CEILING FAN W/ LIGHT
D
�C SMOKE AND CARBON MONOXIDE DETECTOR
SD SMOKE DETECTOR
F r MOTOR
?� (EXHAUST FAN)
ELECTRICAL PANEL
The nnw'itnn -SM
water Neater
� I•- j
TITAN -SCR4
TRIPLE ELEMENT
ELECTRONIC TANKLESS WATER HEATER
AUTOMATIC TEMPERATURE CONTROL
NOTE: THESE MODELS NEED TWO RUNS OF 8 GAUGE WIRE, AND A
DOUBLE POLE 40 AMPS BREAKER.
DIMENSIONS: 12 X 11 X 3
WEIGHT: 10 POUNDS
WATER CASING: BRASS
PIPE FITTING: 1/2" STANDARD PIPE
PRESSURE REQUIEREMENTS: 5 PSI -MIN / 150 PSI -MAX
ELEMENTS: INCOLOY / NICHROME
ACTIVATION: 0.4 GPM -ON / 0.3 GPM -OFF
WARRANTY: 10 YEARS ON WATER CASING, 1 YEAR ON C
CAPACITY: ONE GALLON
EFFICIENCY: 0.95
II I? �1IIl
qp
P14A 3A_GFI - - - - 17A GFI
Z 15A
BEDROOM 20A QJ1 A GFI / GFI
19A A ' - -- 7 W/P f�
i
i
BATH 6 r / 16A
16A
14A O_
O -- - 2 \` � �� DINING 17A GFI /
i
GFI
OA I13A KITCHEN /' ROOM 7 I
I
SD CL 11L6 GFI O ° O 13A GF �;
O
14A 7Z
CLOSET N 2,4A
A/C ;
7Z f A
�� 14 �� W, 12
5,7A / TANKLESS W/H SD
n ,
14A OO O 20A
O n
BEDROOM
12A
PROPOSED ELECTRICAL PLAN
SCALE: 1/4"=V-0"
12A
6A
16A
15A lz
EXISTING
I
CARPORT
STRUCTURE ;
(�=12A i LIVING TO REMAIN
I ► ROOM
,
CLO�ET
i 16A r�
I '
I
12A J/ 15A 7z 15A 16A
GFI �)
1 16A Z W/P
i
I 15A
15A
GFI 20 \\� 16A f�
W/P _ - Y
- - - - -- %I
REv'IS,[OII
No./DATE: -----
No. /DATE:
THESE DRAWING & SPECIFICATIONS
ARE INSTRUMENTS OF SERVICE AND
SHALL REMAIN THE PROPERTY OF
TERRACOTA BUILDING SERVICES,
WHETHER THE PROJECT FOR WHICH
THEY WERE PREPARED IS EXECUTED
OR NOT, THEY ARE NOT TO BE
USED IN ANY MANNER ON OTHER
PROJECTS OR EXTENSIONS TO THIS
PROJECT EXCEPT BY AGREEMENT IN
WRITING AND WITH THE APPROPRIATE
COMPENSATION TO TERRACOTA
BUILDING SERVICES IS PROHIBITED.
CONTRACTOR IS RESPONSIBLE FOR
VERIFYING ALL SITE CONDITION PRIOR
TO PROCEEDING WITH WORK.
U
•w
i .
c
H � '
W k M C CA
0 r- V- o
M
OV W M O
A �N
d o��ww
��u� 0
0
O 00
m
U SON
l- O
O
O
00
CD
Q0
I`r7
z
r� Ln
N
LLJ
� I g
L.J ff-)
z 0 00 0—:f � oo
< _
o J Cn — W Q
CD w
r") CD �
Q _Q
o W
(_0 C)-
JOB No.: 515
DRAWN BY: T.B.S.
SCALE: AS SHOW
DATE: 06 -07 -2010
SHEET NAME
ELECTRICAL
Eml
SHEET 8 OF 10
The nnw'itnn -SM
water Neater
� I•- j
TITAN -SCR4
TRIPLE ELEMENT
ELECTRONIC TANKLESS WATER HEATER
AUTOMATIC TEMPERATURE CONTROL
NOTE: THESE MODELS NEED TWO RUNS OF 8 GAUGE WIRE, AND A
DOUBLE POLE 40 AMPS BREAKER.
DIMENSIONS: 12 X 11 X 3
WEIGHT: 10 POUNDS
WATER CASING: BRASS
PIPE FITTING: 1/2" STANDARD PIPE
PRESSURE REQUIEREMENTS: 5 PSI -MIN / 150 PSI -MAX
ELEMENTS: INCOLOY / NICHROME
ACTIVATION: 0.4 GPM -ON / 0.3 GPM -OFF
WARRANTY: 10 YEARS ON WATER CASING, 1 YEAR ON C
CAPACITY: ONE GALLON
EFFICIENCY: 0.95
II I? �1IIl
qp
P14A 3A_GFI - - - - 17A GFI
Z 15A
BEDROOM 20A QJ1 A GFI / GFI
19A A ' - -- 7 W/P f�
i
i
BATH 6 r / 16A
16A
14A O_
O -- - 2 \` � �� DINING 17A GFI /
i
GFI
OA I13A KITCHEN /' ROOM 7 I
I
SD CL 11L6 GFI O ° O 13A GF �;
O
14A 7Z
CLOSET N 2,4A
A/C ;
7Z f A
�� 14 �� W, 12
5,7A / TANKLESS W/H SD
n ,
14A OO O 20A
O n
BEDROOM
12A
PROPOSED ELECTRICAL PLAN
SCALE: 1/4"=V-0"
12A
6A
16A
15A lz
EXISTING
I
CARPORT
STRUCTURE ;
(�=12A i LIVING TO REMAIN
I ► ROOM
,
CLO�ET
i 16A r�
I '
I
12A J/ 15A 7z 15A 16A
GFI �)
1 16A Z W/P
i
I 15A
15A
GFI 20 \\� 16A f�
W/P _ - Y
- - - - -- %I
REv'IS,[OII
No./DATE: -----
No. /DATE:
THESE DRAWING & SPECIFICATIONS
ARE INSTRUMENTS OF SERVICE AND
SHALL REMAIN THE PROPERTY OF
TERRACOTA BUILDING SERVICES,
WHETHER THE PROJECT FOR WHICH
THEY WERE PREPARED IS EXECUTED
OR NOT, THEY ARE NOT TO BE
USED IN ANY MANNER ON OTHER
PROJECTS OR EXTENSIONS TO THIS
PROJECT EXCEPT BY AGREEMENT IN
WRITING AND WITH THE APPROPRIATE
COMPENSATION TO TERRACOTA
BUILDING SERVICES IS PROHIBITED.
CONTRACTOR IS RESPONSIBLE FOR
VERIFYING ALL SITE CONDITION PRIOR
TO PROCEEDING WITH WORK.
U
•w
i .
c
H � '
W k M C CA
0 r- V- o
M
OV W M O
A �N
d o��ww
��u� 0
0
O 00
m
U SON
l- O
O
O
00
CD
Q0
I`r7
z
r� Ln
N
LLJ
� I g
L.J ff-)
z 0 00 0—:f � oo
< _
o J Cn — W Q
CD w
r") CD �
Q _Q
o W
(_0 C)-
JOB No.: 515
DRAWN BY: T.B.S.
SCALE: AS SHOW
DATE: 06 -07 -2010
SHEET NAME
ELECTRICAL
Eml
SHEET 8 OF 10